T3 PWR_OK DELAY TIME 500 mS 100 mS
T4 DC SAVE TIME 1 mS
T5 HOLD-ON TIME (AT NOMINAL AC INPUT) 12 mS
4. OUTPUT PROTECTION
4.1 TOTAL POWER PROTECTION: ( OPP )
Total power 135% max with shut-down and latch off protection.
4.2 OVER VOLTAGE PROTECTION: ( OVP )
OVER ACTIVE RANGE
VOLTAGEAT Min. Max. RESULT
+3.3V 3.76V 4.8V
+5V 5.7V 7.0V
+12V 15.6V
Shutdown&Latch OFF The
Group 1 DC Output
4.3 SHORT CIRCUIT PROTECTION: ( SCP )
The short between any output of group 1 will shut down all group1.
The short at group 2 will Shut down both group 1 and group 2.
4.4 RESET AFTER SHUTDOWN
Whenever the power supply latches into shutdown state due to fault condition on its output,
The power supply will return to normal operation only after the fault has been removed and
the power switch has been cycled off/on with A MINIMU M OFF TIME OF 20mS. (PS- ON)
5. POWER GOOD SIGNAL:
Signal Type: open collector +5DC, TTL compatible.
Logic Level: <0.4V while sinking 4 mA.
Logic Level High: between 2.4VDC and +5V output while sourcing 200 uA.
6. EFFICIENCY:
6.1 AT FULL LOAD:
Over 72% at normal input voltage.
74% at AC 100v 60Hz ; 76% at AC 230v 50Hz (typical)
6.2 ENERGY STAR MODE
Over 50% at 30W max power consumption with 15W load or more delivered to
DC power output.
6.3 STANDBY MODE
During measurement of the ”STANDBY MODE” condition, the main converter is off
(PS_ON=High). +5Vsb converter is working and standby input power is measured.
true RMS input power (standby)
+5Vsb/ 0.5A; input voltage: 230VAC 50HZ < 5W
true RMS input power (standby)
+5Vsb/ 0A ; input voltage: 230VAC 50HZ < 1.5W