DC/DC CONVERTERS 10.8-15W High Efficiency DC/DC Converters 1
2 YEAR WARRANTY
CXE15 Series
Single output
High efficiency topology, 87% typical at 5V
Industry standard footprint
Wide operating temperature, up to and exceeding 70˚C
(natural convection)
90% to 110% output trim
No minimum load
Overvoltage protection
Remote on/off control
The CXE15 is a new high efficiency open frame isolated 15 Watt converter series in an
industry standard footprint. The first four models in the series feature an input voltage
range of 33 to 75VDC and are available in output voltages of 5V, 3.3V, 2.5V and 1.8V.
The output voltage on each model is adjustable from 90% to 110% of the nominal
value. Typical efficiencies for the models are 87% for the 5V, 86% for the 3.3V, 85% for
the 2.5V and 83% for the 1.8V version. The CXE15 series also has a remote on/off
capability with active high or active low logic. Overcurrent and overvoltage protection
features are included as standard. With full international safety approval including
EN60950 and cUL1950, the CXE15 reduces compliance costs and time to market.
All specifications are typical at nominal input, full load at 25°C unless otherwise stated
EMC CHARACTERISTICS
Conducted emissions
EN55022 (See Note 3)
Level A
EN55022 (See Note 3)
Level B
Radiated emissions
EN55022 (See Longform data sheet)
Level B
Immunity:
ESD air EN61000-4-2 8kV, 15kV
ESD contact EN61000-4-2 6kV, 8kV
Radiated field enclosure EN61000-4-3 10V/m
Conducted (DC power) EN61000-4-6 10V
Conducted (signal) EN61000-4-6 10V (See Note 8)
Input transients ETS 300 132-2, ETR 283
GENERAL SPECIFICATIONS
Efficiency See table
Operational insulation Input/output 1500VDC
Switching frequency Fixed 265kHz typ.
Approvals and UL/cUL1950, EN60950
standards TÜV Rheinland
(See Note 5)
Material flammability UL94V-0
Weight 12g (0.42oz)
MTBF MIL-HDBK-217F >600,000 hours
Representative model: 48S05 @ 48Vin, 40°C,
100% load ground benign
BELLCORE 332 >1,500,000 hours
ENVIRONMENTAL SPECIFICATIONS
Thermal performance Operating ambient -40°C to +65°C
(See Note 9) temp. (3.3V and 5V)
Operating ambient -40°C to +70°C
temp. (1.8V and 2.5V)
Non-operating -40°C to +120°C
(All models)
OUTPUT SPECIFICATIONS
Voltage adjustability 90% to 110%
Total error band (See Note 11) ±3.5% max.
Line regulation 1V8 and 2V5 models 0.5% max.
Low line to high line 3V3 and S05 models 0.1% max.
Load regulation 1V8 model 2.0% max.
Full load to min. load 2V5 model 1.5% max.
3V3 and S05 models 0.5% max.
Minimum load 0%
Overshoot 1V8 and 2V5 models 3.5% max.
3V3 and S05 models None
Undershoot None
Ripple and noise 1V8 and 2V5 models 40mV pk-pk
(See Note 1) 14mV rms
5Hz to 20MHz 3V3 and S05 models 70mV pk-p
20mV rms
Transient response 1V8 and 2V5 models 150mV
(See Note 2) 3V3 and S05 models 100mV
typ. deviation 400µs recovery to
within total error band
INPUT SPECIFICATIONS
Input voltage range 48Vin nominal 33 to 75VDC
Input current No load 35mA max.
Remote OFF 25mA max.
Input current (max.) (See Note 4) 0.55A max. @ Io max.
and Vin = 33 to 75V
Input reflected ripple (See Note 6) 5mA (pk-pk) typ.
Active high remote ON/OFF (See Note 10)
Logic compatibility Open collector ref to -input
ON Open circuit or >2VDC
OFF <1.2VDC
Undervoltage lockout Power up 33V (typ.)
Power down 30V (typ.)
Start-up time Power up 1.5ms (typ.)
(See Note 7) Remote ON/OFF 2.5ms (typ.)
SPECIFICATIONS
File Name: CXE15S.PDF Rev: 01 Oct 2002
TÜV
For the most current data and application support visit www.artesyn.com/powergroup/products.htm
Notes
1Measured as per recommended set-up. See Application Note 116 for
details.
2di/dt = 0.1A/µs, Vin = 48VDC, Tc = 25°C, load change = 0.5 lo max. to 0.75
lo max. and 0.75 lo max. to 0.5 lo max.
3The CXE15 meets level A and level B conducted emissions only with
external components connected before the input pins to the converter.
See Application Note 116 for details.
4Recommended input fusing is a 2A HRC 200V rated fuse.
5This product is only for inclusion by professional installers within other
equipment and must not be operated as a stand alone product.
6Measured with external filter. See Application Note 116 for details.
7Start-up into resistive load.
8Signal line assumed < 3m in length.
9Operating ambient temperatures are specified at natural convection.
Higher operating temperatures are possible with increased airflow. See
Application Note 116 for details.
10 Remote ON/OFF (pin 3) and Trim (pin 5) are currently available individually
or together by special order only. Manufacturing lead times may apply. The
base model includes pins 1, 2, 4, and 6. Use the suffix ‘–R’ for pin 3 with
negative logic, ‘-S’ for pin 3 with positive logic, and ‘-T’ for the Trim pin.
For example, a CXE 5V output with all six pins and positive remote
ON/OFF logic should be ordered as ‘CXE15-48S05-ST’.
11 This parameter is calculated at worst case line, load, temperature and initial
settings.
CAUTION: Hazardous internal voltages and high temperatures.
Ensure that unit is not user accessible.
PROTECTION
Short circuit protection Continuous
Overvoltage protection Non-latching clamp
TELECOM SPECIFICATION
Central office interface A ETS300-132-2, input voltage
and current requirements
PIN CONNECTIONS
PIN NUMBER FEATURE
1 Vin -
2 Vin +
3 On/Off (See Note 10)
4 Vout +
5 Trim (See Note 10)
6 Vout -
CXE15 Series
Single output
DC/DC CONVERTERS 10.8-15W High Efficiency DC/DC Converters 2
Please consult our website for the following items: Application Note Longform Data Sheet www.artesyn.com
File Name: CXE15S.PDF Rev: 01 Oct 2002
OUTPUT INPUT OVP OUTPUT OUTPUT OUTPUT EFFICIENCY REGULATION MODEL
POWER VOLTAGE VOLTAGE CURRENT CURRENT (TYP.) LINE LOAD NUMBER (10)
(MAX.) (MIN.) (MAX.)
10.8W 33-75VDC 2.3VDC 1.8V 0A 6A 83% 0.3% 2.0% CXE15-48S1V8
15W 33-75VDC 3.2VDC 2.5V 0A 6A 85% 0.3% 1.5% CXE15-48S2V5
15W 33-75VDC 4.0VDC 3.3V 0A 4.5A 86% 0.1% 0.5% CXE15-48S3V3
15W 33-75VDC 6.0VDC 5.0V 0A 3A 87% 0.1% 0.5% CXE15-48S05
Data Sheet © Artesyn Technologies
®
2002
The information and specifications contained in this data sheet are believed to be correct at time of publication. However, Artesyn Technologies accepts no responsibility for consequences arising
from printing errors or inaccuracies. Specifications are subject to change without notice. No rights under any patent accompany the sale of any such product(s) or information contained herein.
For the most current data and application support visit www.artesyn.com/powergroup/products.htm
CXE15 Series
Single output
DC/DC CONVERTERS 10.8-15W High Efficiency DC/DC Converters 3
Please consult our website for the following items: Application Note Longform Data Sheet www.artesyn.com
File Name: CXE15S.PDF Rev: 01 Oct 2002
International Safety Standard Approvals
UL/cUL 1950 3rd edition. File No. E135734
TÜV TÜV Rheinland. Certificate No. R2074133
1.000 (25.40)
TOP VIEW
SIDE VIEW
BOTTOM VIEW
2.000 (50.80)
0.600 (15.24) 0.600 (15.24)
0.800 (20.32)
0.200 (5.08)
0.300 (7.62)
0.10
(2.54)
0.400 (10.16)
0.800 (20.32)
0.120 (3.05)
0.100
(2.54) 0.800 (20.32) Case Outline
0.400 (10.16)
0.400 (10.16)
0.040 (1.016)
0.200
(5.08)
0.200 (5.08) .200(5.08) .560 (14.22)
.060 (1.52)
Standoff (4 places) Plated Through Hole
0.052-0.06 (1.321-1.40) typical
Recommended Hole Pattern
0.015 (0.38)
0.350 (8.89)
0.400 (10.16)
0.600 (15.24)
1
2
4
5
63
0.040 (1.02)
4
5
63
1
2
Dimensions in Inches [mm]