▣ Main products
http://www.autonics.com
Satisfiable Partner For Factory Automation
■HEAD QUARTERS :
41-5. Yongdang-dong, Yangsan-si, Gyeongnam, 626-847,
Korea
■OVERSEAS SALES :
Bldg. 402 3rd FL., Bucheon Techno Park, 193, Yakdae-dong,
Wonmi-gu,
Bucheon-si, Gyeonggi-do, 420-734, Korea
TEL : 82-32-610-2730 / FAX : 82-32-329-0728
■E-mail : sales@autonics.com
The proposal of a product improvement
and development :product@autonics.com
■ Proximity sensors
■ Area sensors
■ Photoelectric sensors
■ Fiber optic sensors
■ Door/Door side sensors
■ Rotary encoders
■ Sensor controllers
■ Tachometer/Pulse(Rate) meters
■ Temperature/Humidity transducers
■ Switching power supplies
■ Stepping motors/drivers/motion controllers
■ Field network devices
■ Laser marking system(CO₂, Nd:YAG)
■ Laser welding/soldering system
■ Counters
■ Timers
■ Display units
■ Panel meters
■ Pressure sensors
■ Power controllers
■ Graphic/Logic panels
■ Temperature controllers
PANEL METER
MT4N SERIES
Thank you very much for selecting Autonics products.
For your safety, please read the following before using.
※Please keep these instructions and review them before using this unit.
1.
In case of using this unit with machinery(Nuclear power control, medical equipment, vehicle, train, airplane,
combustion apparatus, entertainment or safety device etc), it is required to install fail-safe device.
It may cause a fire, human injury or property loss.
2.It must be mounted on panel.
It may give an electric shock.
3.Do not connect, inspect or repair terminals when it is power on.
It may give an electric shock.
4.Do not disassemble or modify this unit. If needs, please contact us.
It may cause a fire and give an electric shock.
5.Please check the number of terminal when connecting power or measured input.
It may cause a fire.
※Please observe the cautions that follow;
▣ Caution for your safety
▣ Specifications ▣ Parameter
Warning
Serious injury may result if instructions are not followed.
Caution
Product may be damaged, or injury may result if instructions are not followed.
※The following is an explanation of the symbols used in the operation manual.
Caution: Injury or danger may occur under special conditions.
1.This unit shall not be used outdoors.
It might shorten the life cycle of the product or give an electric shock.
Use this product indoors only. Do not use the product outdoors or at locations subject to the
temperatures or humidity outside.(Example: rain, dirty, frost, sunlight, condensation, etc.)
2.
When connecting wire, use AWG 20(0.50㎟) be used and tighten screw bolt on terminal block
with 0.74 to 0.90N.m strength.
It may cause a malfunction or fire due to contact failure.
3.Please observe the rated specification.
It might shorten the life cycle of the product and cause a fire.
4.Do not use beyond of the rated switching capacity of relay contact.
It may cause insulation failure, contact melt, contact failure, relay broken and fire etc.
5.
In cleaning the unit, do not use water or an oil-based detergent.
It may cause a fire and give an electric shock.
6.Do not use this unit in place where flammable or explosive gas, humidity, direct ray of the
light, radiant heat, vibration or impact, etc. exists.
It may cause a fire or explosion.
7.Do not inflow dust or wire dregs into the unit.
It may cause a fire or mechanical malfunction.
8.Please wire properly after checking the polarity of measuring terminals.
It may cause a fire or explosion.
Warning
Caution
▣ Ordering information
▣ Caution for using
▣ Specification of measured input and range
▣ Parameter setting
▣
Monitoring peak display value function
[PA 0: H.PEK/ L.PEKmode, PA 2: PEK.Tmode ]
▣
Current output(DC4-20mA)
Scale adjustment function
[ PA 2: FS-H/ FS-Lmode ]
▣
Error correction function
[ PA 1: INB.H/ INB.
Lmode ]
▣
Gradient correction function
[ PA 1: INB.H mode ]
▣ Preset output mode
[ PA 2: OU1.T / OU2.T mode ]
▣
Measuring AC frequency
function
[ PA 1: DISP mode ]
▣
Zero adjustment function
▣
Display cycle delay function [PA 2: DIS.T mode]
▣
Startup compensation timer function
[ PA 2: STA.T
mode
]
▣
Initialization function
EP-KE-77-0012G
▣ Front panel identification
▣ Terminal connection
▣ Panel cut-out
▣
Error display function
▣ Parameter 2
: Upgrade feature
M A N U A L
1. Allowable installation environment
①If shall be used indoor ②Altitude Max. 2,000m ③Pollution Degree 3 ④Installation Category II
2. Use compression terminal(M3, Max. 6.0mm) to connect AC power.
3. Separate from high-tension line, power line to avoid inductive noise.
4. Install power switch or circuit breaker to on / off the power at once.
5. The switch or circuit breaker should be installed nearby users for safety.
6.
Avoid to use the unit nearby machinery with high frequency noise, such as high frequency welder / sewing machine and high capacity SCR
controller etc.
7. "
HHHH
" or "
LLLL
" is displayed, off the power and check
lines.
8. Noise inflowing from power line can cause serious problem
for D.P.M.(Digital Panel Meter) of AC power. It is hard
to install protection circuit
in the small unit even there is
condenser to avoid noise between lines at primary of power
transformer. Use noise absorber circuit such as line filter,
varistor at external lines when abnormal voltage is occurred
by power relay, magnet switch, high frequency equipment are
operated in same lines.
9. Input line : Use shield wire when measured input line is
extended or in a place with noise and open the non-used
terminals.
Model
MT4N
Power supply 12-24 VDC/AC 100-240 VAC
Power consumption
DC: 3W, AC: 5VA 5VA
Display method
7 Segment LCD Display, Character height: 9mm
Display accuracy
23℃ ± 5℃ ☞ DC Type: F.S.±0.1% rdg±2digit / AC Type: F.S.±0.3% rdg±3digit
DC/AC Type: Within F.S.±0.3% rdg±3digit only for Current 5A terminal
-
10℃ to 50℃ ☞ DC/AC Type: F.S.±0.5% rdg±3digit
Input
DC Voltage/Current, AC Voltage/Current, AC Frequency
Max. allowable input
110% F.S. for input spec.
A/D conversion method
Practical oversampling using successive approximation ADC
Sampling cycle
50ms(DC), 16.6ms(AC)(1/12,000)
Max. display range
-1999 to 9999(4 Digit)
Preset output
● Relay output ☞ Contact capacity: 125VAC 0.3A, 30VDC 1A/Contact composition: N.O(1a)
● NPN/PNP Open Collector output ☞ 12-24VDC ±2V 50mA Max.(Load resistance)
Sub output
(Transmission output)
● RS485 communication output
☞ Baud rate: 1200/2400/4800/9600, Transmission method: 2 wires half duplex, Tuning
method: Sub-synchronization, Protocol: Modbus type
●
DC4-20mA output
☞ Resolution: 12,000 division(Load resistance max. 600Ω)
AC measuring function
Selectable RMS or AVG
Frequency measuring
function
Measurement range: 0.100 to 9999Hz(Differ according to decimal point position)
Hold function
※1
Includes(Outer hold function)
Insulation resistance
Min. 20㏁(at 500VDC megger)
Dielectric strength
1000VAC for 1 minute
(Between external terminal and case)
2000VAC for 1 minute
(Between external terminal and case)
Noise strength
±2kV the square wave noise(pulse width: 1㎲) by the noise simulator
Vibration Mechanical
0.75mm amplitude at frequency of 10 to 55Hz in each of X, Y, Z direction for 2 hours
Malfunction
0.5mm amplitude at frequency of 10 to 55Hz in each of X, Y, Z direction for 10 minutes
Shock Mechanical
100m/s2(Approx. 10G) in X, Y, Z directions for 3 times
Malfunction
300m/s2(Approx. 30G) in X, Y, Z directions for 3 times
Environ-
ment
Ambient
temperature
-10 to 50℃, Storage: -20 to 60℃
Storage
humidity
35 to 85%RH, Storage: 35 to 85%RH
Insulation type
※2
Approval
-
Unit weight
Approx. 64g
Parameter Display
Function Note
PA1
(Parameter 1)
IN-T Input type
Selectable RMS/AVG in AC type
Available AC type only.
IN-R
Input range Input range selection -
DISP
Display Display type selection
Selectable:
STND
/
SCAL
/
FREQ
STND
Standard Standard scale range Display max. display value of
STND
FREQ
Frequency Frequency display Available AC type only.
SCAL
Scale Scale range
These are displayed in SCAL only and set
max/min. display value(-1999 to 9999).
H-SC
High scale
Set max. value of display range
L-SC
Low scale
Set min. value of display range
DOT
Dot
Set decimal point position
It is displayed in SCAL/FREQ only and set the position.
D-UNT
Display unit lamp
Set display unit
Set range
: mV / V / mA / A / Hz / off
INB.H
Input bias high
Correct High-limit gradient of display value
STND
/
SCAL
Correction range: 0.100 to 5.000
FREQ
Correction range: 0.100 to 9.999
INB.L
Input bias low
Correct Low-limit gradient of display value
Correction range:
-
99 to 99
INB.E
Input bias exponent
Set display index of frequency mode
Set range
: 10-2/10-1/100/101
PA2
(Parameter 2)
OU1.T
Out1 type Select output mode of OUT1
OFF
/
HI
/
LO
/
HL
/
HL-G
OU2.T
Out2 type Select output mode of OUT2
OFF
/
HI
/
LO
/
HL
/
HL-G
HYS.1
Out1 hysteresis Select hysteresis of OUT1
Within 1 to F.S. 10%(Variable depending
on set of input range and prescale.)
HYS.2
Out2 hysteresis Select hysteresis of OUT2
STA.T
Startup ompensation
time
Set startup compensation time
Set range: 0.0 to 99.9 sec.
PEK.T
Peak time
Set monitoring delay time for peak value(sec)
Set range: 00 to 30 sec.
DIS.T
Display time Set sampling time(sec)
0.1 to 5.0 sec.(Variable by 0.1 sec.)
COLR
Color
Select color
RED
/
GRN
/
YEL
/
R-G
/
G-R
ZERO
Zero key
Enable zero adjustment key
No: Enable/disable zero adjustment key
Yes: Enable zero adjustment key
EVIN
Event input
Set external terminal(11, 12) function
Hold: Use external terminal as Hold terminal
Zero:
Use external terminal as zero adjustment terminal
※
It is enable to use in option mode.
FS-H
Full scale high
Set High-limit value output position of PV output
Min. set range: Min. 10% F.S.
FS-L
Full scale low
Set Low-limit value output position of PV output
Max. set range: Max. FS-H 10%
ADRS
Address
Set communication address
Set range: 01 to 99
BPS
Bit per second
Set baud rate(bps)
Selectable:1200/2400/4800/9600
PRTY
Parity bit
Set parity bit
Selectable: None/ Even / Odd
STP
Stop bit
Set stop bit
Set range: 1/2
RSY.T
Response wating time
Set response wating time
Set range: 5 to 99
LOC
Lock Enable lock status Selectable: OFF/LOC1/LOC2/LOC3
PA0
(Parameter 0)
OU1.H
OUT1 high preset
Set value of OUT1 High-limit output
Set the range within display range of
STND/SCAL.
For MT4N-DV/DA Type, set range of
OU1.H/OU2.H and OU1.L/OU2.L is within -5
to 110%.
OU1.L
OUT1 low preset
Set value of OUT1 Low-limit output
OU2.H
OUT2 high preset
Set value of OUT2 High-limit output
OU2.L
OUT2 low preset
Set value of OUT2 Low-limit output
H.PEK
High peak
Max. value by data monitoring
key is pressed, it will be returned
to initial status.
L.PEK
Low peak
Min. value by data monitoring
※It may cause malfunction if above instructions are not followed.
※ 1: " " Mark indicated that equipment protected throughout by double insulation or reinforced insulation.
※ 2: The indicator has no Hold function.
※ Environment resistance is rated at no freezing or condensation.
1.Advance to the parameter to be changed when
press
MODE
key continuously in RUN mode and
release
MODE
key at the parameter.(Refer to "▣
Parameter setting")
2.When press
MODE
key in each parameter, the
initial mode of the parameter is displayed.(Refer
to the description of each parameter.)
3.
When press one of , , keys in display mode.
5. When press
MODE
key to complete the change and
it is advanced to the next mode after flashes 2 times.
6. When press
MODE
key for 3 sec. after change, it
returns to RUN mode.
Set High-limit preset value of OU1.T.
(It is not displayed when OU1.T mode
value of PA2 is OFF.)
※Change the value by keys.
Set Low-limit preset value of OU1.T.
(It is not displayed when OU1.T mode
value of PA2 is OFF.)
※Change the value by keys.
Set High-limit preset value of OU2.T.
(It is not displayed when OU2.T mode
value of PA2 is OFF.)
※Change the value by keys.
Set Low-limit preset value of OU2.T
(It is not displayed when OU2.T mode
value of PA2 is OFF.)
※Change the value by keys.
It displays High peak value in RUN mode
and keys are pressed, it is
reset.
It displays Low peak value in RUN mode
and keys are pressed, it is
reset.
If PEK.T monitoring delay time in PA2 is '00', H.PEK and
L.PEK are not displayed.
Select measured input specification.
(Refer to "▣Specification of
measured input and range".)
Set display type for measured input as
STND ↔ SCAL↔ FREQ and FREQ.
It is only available for AC type.
Select measuring type for AC input type.
Select RM5 ↔ AU6
Set decimal point position.
0↔ 0.0↔ 0.00↔ 0.000
Set display value for min.
input of measured input.
Set display unit.
Set range:
mV/V/mA/A/Hz/off
Adjust High-limit display value
gradient for max. input.
Set range:
0.100 to 5.000
Set display value for max.
input of measured input.
Set frequency measuring range.
(Refer to "▣ Measuring AC
frequency function" .)
Adjust High-limit display value
gradient for max. input.
Set range: 0.100 to 9.999
Set index for frequency display.
Set range:10-2↔10-1
↔10 0↔10 1
It shows max. display
value of standard
specification.
Display value is fixed.
※ After return to RUN mode, press
MODE
key within 2 sec., it will return to
previous parameter.(Refer to the below descriptions for set parameter.)
※ Press
MODE
key for 2 sec. in RUN mode, [ PA1](Parameter 1) is displayed.
※ Press
MODE
key for 4 sec. in RUN mode, [ PA2] is displayed after [ PA1].
When press
MODE
key is pressed continually, it stops displaying at [ PA2].
※ It is advanced to current display parameter releasing
MODE
key at [ PA1] or [ PA2].
※ Press
MODE
key for 3 sec., it is returned to RUN at any position.
※ If any key is not touched for 60 sec. in each parameter, it will return to RUN mode
.
Size
Input
Power supply
Control output
Item
Digit
4
MT
NNDV E N
Without output function
0
Relay output(2 Contacts)
1
NPN Open collector
output
(OUT1,GO,OUT2)
2
PNP Open collector
output
(OUT1,GO,OUT2)
3
Relay(OUT1)+PV transmission(DC4-20mA)output
4
Relay(OUT2)+RS485 communication output
E
12-24VDC/AC
4
100-240VAC
DV DC Volt
DA DC Ampere
AV AC Volt
AA AC Ampere
NDIN W48×H24㎜
49999(4 Digit)
MT Multi Meter
OUT1: Preset output of OUT1
GO: Preset Go output of OUT1/OUT2
OUT2: Preset output of OUT2
MODE :
MODE key
:
Shift key
:
Down key
:
Up key
mV, V Unit
mA, A Unit
Hz Unit
This function is to display setting(-1999 to 9999) of particular High/Low-limit value in order to display
High/Low-limit value of measured input. If measured inputs are 'a' and 'b' and particular values are 'A'
and 'B', it will display a=A, b=B as below graphs.
Display Display Display
Display
B
A
B
A
B
A
B
A
A
B
A
B
Display Display
Input value Input value Input value Input value Input value Input value
a b a b ba b
a b b
It monitors Max./Min. value of display value based on current display value and then display the data in H.PEK
mode and L.PEK mode of parameter 0. Set delay time(0 to 30 sec.) in PEK.T mode of parameter 2 in order to avoid
caused by initial overcurrent or overvoltage, when monitoring the peak value. Delay time is 0 to 30 sec. and it starts
to monitor the peak value after set time.
When keys are pressed at H.PEK and L.PEK mode of parameter 0, it will be initialized.
※ Monitoring function is not indicated when setting the PEK.T of parameter 2 as "0".
It corrects a gradient of prescale value and display value.
(Figure 1)Display value Y can be adjusted as α, β times against X input value by
correction function [ INB.H ] and used as correction function of max. display value
[ H-SC ]. Adjustment range is 0.100 to 5.000 and multiply current gradient by the
value.
③
In this case, please check below chart. Please set as
INB.H× H-SC = 15.000
※ Set output mode separately for each OUT1/OUT2.
※ OUT1/OUT2 are operated individually depending on output operation mode.
※ Setting value mode of parameter group 0 is displayed depending on output operation mode.
※ GO outputs when the period both OUT1/OUT2 are off.(NPN/PNP Open collector output type)
It adjusts the display value of the optional configured
input value as zero by force, zero point error can be
adjusted with 3 ways as below.
When zero point adjustment with front key and
Hold terminal is finished normally, zero point
of measuring terminal is displayed and the
adjusted value is saved in INB.L automatically.
※
Refer to description [▣ Error correction function],
[▣ Error indication function] and [▣ Parameter 2]
for function and error.
Output
Display value
FS-L FS-H
20mA
Min. setting range
10% F.S.
4mA
In some applications the measured input may fluctuate which in turn causes the display to fluctuate. By
adjusting the display cycle delay function time in the DIS.T mode in parameter 2, the operator can adjust
the display time within a range of 0.1 sec to 5 sec. For example, if the operator sets the display cycle time
to 4.0 sec., the display value displayed will be the average input value over 4 sec. and also will show any
changes if any every 4 sec.
※ The above specifications are subject to change without notice.
This time function limits the operation of an output until the measured input(overvoltage or inrush
current) is stable at moment of power on. All outputs are off during startup compensation time
setting after power is applied.
Setting range: 00.0 to 99.9 (Unit: sec.) Factory default: 00.0
※
Zero adjusting error is returning to measuring mode after
[ OVER] flashes twice.
※ Refer to "▣ Measuring AC frequency function" for frequency
measuring range.
(Unit: mm)
Min. 55
Min. 37
22.2+0.3
-0
45+0.6
-0
● MT4N-DV-□□
250mV
/50mV
SOURCE
12-24VDC/AC
100-240VAC
5V/1V
50V/10V
1 2 3 4 5 6
● MT4N-AV-□□
5V/
2.5mV
SOURCE
12-24VDC/AC
100-240VAC
50V/25V
250V/125V
1 2 3 4 5 6
● MT4N-DA-□□
5mA
/2mA
SOURCE
12-24VDC/AC
100-240VAC
50mA/4-20mA
500mA/200mA
1 2 3 4 5 6
● MT4N-AA-□□
100mA
/50mA
SOURCE
12-24VDC/AC
100-240VAC
500mA/250mA
5A/2.5A
1 2 3 4 5 6
<Option>
● Relay output [MT4N-□□-□0]
OUT1 OUT2 HOLD/ZERO
7 8 9 10 11 12
●
NPN Open Collector
output
[MT4N-□□-□1]
OUT1 OUT2GO HOLD/ZERO
7 8 9 10 11 12
● PNP Open Collector output [MT4N-□□-□2]
OUT1 OUT2GO HOLD/ZERO
7 8 9 10 11 12
● Relay+Current(DC4-20mA) output [MT4N-□□-□3]
OUT1DC4-20mA HOLD/ZERO
7 8 9 10 11 12
● Relay+RS485 communication output [MT4N-□□-□4]
OUT1
B(-) A(+)
HOLD/ZERO
7 8 9 10 11 12
▣ Prescale function[PA1:
H-SC
/ L-SC mode]
It initializes parameter setting state. Press
+ + keys simultaneously for over 5 sec. in
RUN status, it returns to factory default value.
Display Description
HHHH
Flashes when measured input is exceeded
the max.allowable input(110%)
LLLL
Flashes when measured input is exceeded
the min.allowable input(-10%)
D-HH
Flashes
when display input is exceeded H-SC setting value
D-LL
Flashes
when display input is exceeded L-SC setting value
F-HH
Flashes
when input frequency is exceeded the max. display
value of measuring range
OVER
Flashes
when it exceeds zero range(±99)
Oper-
ation
Input
correction
value
Front key Input external
signal
Des-
cription
PA1: Direct
input
correction
value
method
at
INB.
L
mode
Press both
,
keys for 3
sec. at the
measuring
mode
.
Short-circuit
external Hold
terminal no.11,
12 over min.50m.
※It is enable to
use in option
mode.
Setting
method H-SC L-SC INB.H Remark
①
Unavailable
0.000
1.000 -
②
7.500
0.000
2.000
In this case, any setting
methods display same
display value.
③
5.000
0.000
3.000
④
3.750
0.000
4.000
⑤
3.000
0.000
5.000
Mode Output operation Operation
OFF
OUT1 output No output
No output
HI
OUT1 output
OUT1.H
Hysterisis Period ON: Display value≥OUT1.H
Period OFF: Display value≤OUT1.H-Hys
LO
OUT1 output
OUT1.L Period ON: Display value≤OUT1.L
Period OFF: Display value≥OUT1.L+HYS
HL
OUT1 output
OUT1.H
OUT1.L
Period ON: Display value≤OUT1.L
or Display value≥OUT1.H
Period OFF: Display value≥OUT.L+Hys or
Display value≤OUT.H+Hys
HL-G
OUT1 output
OUT1.H
OUT1.L
Period ON: OUT1.L≤Display value≤OUT1.H+Hys
Period OFF: Display value≤OUT.L+Hys or
Display value≥OUT.H+Hys
(Figure1)
Display value
α
β
α Time
β Time
Input value
X
0
Y
Y
Y
Ex)
RUN
++
Press
for over 5 sec.
IN1 T
YES
NO
MODE
▣ Change the parameter
setting value
▣ Parameter 0
▣ Parameter 1
MODE
key
2 sec.
MODE
key
2 sec.
RUN
PA1
PA2
RUN
OU1.H
OU1.L
OU2.H
H.PEk
OU2.L
L.PEk
MODE
MODE
MODE
MODE
MODE
MODE
MODE
PA1
IN-R
DISP
D.UNT
IN-T
STND DOT DOT
H-SC
L-SC
INB.H
INB.L
MODE
MODE
MODE
MODE MODE
MODE
MODE
MODE
MODE
MODE MODE
MODE MODE
<Measured input specification for each model>
Model Measured input range
MT4N-DV 50V 10V 5V 1V 250mV 50mV 50V
MT4N-DA 500mA 200mA 50mA 4-20mA 5mA
2mA 500mA
MT4N-AV 250V 125V 50V 25V 5V 2.5V 250V
MT4N-AA SA 25A 500mA 250mA 100mA 50mA
5A
<When DISP is STND> <When DISP is SCAL> <When DISP is FREQ>
INB.H
INB.E
Select Preset output mode of OUT1 as
OFF↔ HI↔ LO↔ HL↔ HL-G
But, it is only displayed in OUT1 output
included model.
Enable zero adjustment by front key operation
to select YES. Press both + keys simul-
taneously in 3 sec. The deviation value is saved in
INB.L
automatically.
Select Preset output mode of OUT2 as
OFF↔ HI↔ LO↔ HL↔ HL-G
But, it is only displayed in OUT2 output
included model.
Select between hold input by terminal 11, 12
and zero set by external signal.
●
HOLD
:
Hold display value
●
ZERO
:
Zero adjustment by external signal
Select Preset hysteresis of OUT1 within 10%
of F.S.
But, it is not displayed when OU1.T
mode is OFF.
Set High-limit value, 20mADC output position of PV output.
※
When input range and prescale mode are
changed, the set value of FS-H and FS-L is
change automatically as max/min. value of input
range.
Execute variable set display period by 0.1
sec. within 0.1 to 5.0 sec.
Set baud rate of RS485 communication
output within
9600↔4800↔2400↔1200.
Select color with 5 modes.
RED
↔
GRN
↔
YEL
↔
R-G
↔
G-R
● RED, GRN, YEL: Display with 1 color.
● R-G, G-R :
Color is changed when error is occurred.
Ex) R-G :
Red is standard and green when error is
occurred.
※ Color is changed only when error in"▣ Error
display function" is occurred excluding 'over'.
Set parity bit.
Set range: None / Even / Odd
Set stop bit.
Set range: 1/2
Set response waiting time.
Set range: 5 to 99
Enable Lock function with 4 mode,
OFF↔ LOC1↔ LOC2↔ LOC3↔ OFF .
OFF
Disable Lock function
LOC2
Lock parameter 1,2
LOC1
Lock parameter 1
LOC3
Lock parameter 0,1,2
Select Preset hysteresis of OUT2 within
10% of F.S. But, it is not displayed when
OU2.Tmode is OFF.
Set Low-limit value, 4mADC output position
of PV output.
Set monitoring delay time within 00 to 30 sec.
Set startup compensation time.
Set range is 0.0 to 99.9 sec.
Set address of RS485 communication output
within 01 to 99.
OU1.T
ZERO
OU2.T
EVIN
HYS.1
FS-H
PEK.T
STA.T
ADRS
HYS.2
FS-L
DIS.T
BPS
COLR
PRTY
STP
RSM.T
LOC
MODE
MODE
MODE
MODE
MODE
MODE
MODE
MODE
MODE
MODE
MODE
MODE
MODE
MODE
MODE
MODE
MODE
MODE
Max.
0.6mm
● Using line filter ● Using varistor
● Using Single shield wire
● Using double shield wire
Install it closely from DPM
Earth ground
110/
220VAC
110/
220VAC
HI
HIHI
LOW
LOWLOW
INPUT
D.P.M.
D.P.M.
D.P.M. D.P.M.
VinVin
It corrects display value error of measured input.
INB.L:±99 (Adjust deviation of low value)
INB.H:
5.000 to 0.100(Correct gradient(%) of high value)
Display value=(Measured value × INB.H)+ INB.L
Ex)
Low value correction
When there is an application where there is a residual
voltage of 1.2V, but a 0V display is desired, then it
is possible by adjusting the INB.L parameter setting
to 12(offset correcting value or equal to 1.2V without
decimal) that the desired display value of 0 can be
achieved.
Ex) High value correction
When there is an application where the high actual value
of display is 501 and exceeds the 500V display range,
then it is possible by adjusting the INB.H parameter
setting to 0.998(calculated by desired value of 500/actual
value of 501), that the desired value can be achieved.
※ The offset correction range of INB.L is within
-
99 to
99 for D
-0
, D
-1
digit regardless of decimal point.
4.Change the set value by
or key when setting
value is flashed.
Ex)
Change AC type measured input from 250V to 125V.
Press
one
IN-R
DISP
250V 125V
MODE
Mode Setting
value Setting
value
PA2
Display value
15.000
12.000
9.000
6.000
3.000
1.000
Input value
0.2
0.4
0.6
0.8
1V
Display value for
measured input
Type Measured input
and range
Input
impedance
Standard [STND] Praescale [SCAL]
Display rang [Fixed] Display range [Variable]
DC
Volt
0-50V [
50
V] 434.35
㏀
0.00 to 50.00(Fixed)
-1999 to 9999(Variable)
-199.9 to 999.9(Variable)
-19.99 to 99.99(Variable)
-1.999 to 9.999(Variable)
(Display position will be
different depending on
decimal point position
.)
※Please wire proper terminal
to its max. input voltage
within 30 to 100% of input
terminal.
When it is higher than
input voltage, it may cause
breakdown of terminal and
over display range and
the accuracy is decreased
when it is connected to
the terminal under 30%.
0-10V [
10
V] 434.35
㏀
0.00 to 10.00(Fixed)
0-5V [
5
V] 43.35
㏀
0.000 to 5.000(Fixed)
0-1V [
1
V] 43.35
㏀
0.000 to 1.000(Fixed)
0-250mV [
250
mV] 2.15
㏀
0.0 to 250.0(Fixed)
0-50mV [
50
mV] 2.15
㏀
0.00 to 50.00(Fixed)
DC
Ampere
0-500mA [
500
mA] 0.1Ω 0.0 to 500.0(Fixed)
0-200mA [
200
mA] 0.1Ω 0.0 to 200.0(Fixed)
0-50mA [
50
mA] 1.1Ω 0.00 to 50.00(Fixed)
4-20mA [
4-20
mA] 1.1Ω 4.00 to 20.00(Fixed)
0-5mA [
5
mA] 11.1Ω 0.000 to 5.000(Fixed)
0-2mA [
2
mA] 11.1Ω 0.000 to 2.000(Fixed)
AC
Volt
0-250V [
250
V] 1.109
㏁
0.0 to 250.0(Fixed)
0-125V [
125
V] 1.109
㏁
0.0 to 125.0(Fixed)
0-50V [
50
V] 222
㏀
0.00 to 50.00(Fixed)
0-25V [
25
V] 222
㏀
0.00 to 25.00(Fixed)
0-5V [
5
V] 22
㏀
0.000 to 5.000(Fixed)
0-2.5V [
2.5
V] 22
㏀
0.000 to 2.500(Fixed)
AC
Ampere
0-5A [
5
A] 0.01Ω 0.000 to 5.000(Fixed)
0-2.5A [
2.5
A] 0.01Ω 0.000 to 2.500(Fixed)
0-500mA [
500
mA] 0.1Ω 0.0 to 500.0(Fixed)
0-250mA [
250
mA] 0.1Ω 0.0 to 250.0(Fixed)
0-100mA [
100
mA] 0.5Ω 0.0 to 100.0(Fixed)
0-50mA [
50
mA] 0.5Ω 0.00 to 50.00(Fixed)
It measures input signal frequency when it is an AC input
using fixed decimal point[PA1: DOT mode]. Measuring
range can be changed by setting and measuring range
of decimal point position is as below chart.
It is available
to adjust upper gradient in [PA 1: INB.H mode] and [PA
1: INB.E mode]. In order to measure frequency normally,
input signal, over 10% F.S. of measuring range, should be
supplied. Please wire the proper measuring terminal.
①
Measuring range
● 0.100 to 5000Hz: Display accuracy error within
±0.3%F.S.±2Digit
● 5000 to 9999Hz: Display accuracy error within
±1%F.S.±3Digit
② INB.H: 0.100 to 9.999 (Gradient adjustment of high value)
③ INB.E:10-2, 10-1, 10 0, 10 1 (Index adjustment of INB.H
)
Ex)
To display "3.000" in DC 200mV input for measured input specification as 0 to 1V
,
①
Select 0-1VDC for measured input in Parameter 1
②
Standard specification in input: 0-1VDC and 1.000 therefore it has to be 15.000( H-SC)
for 1VDC(Input) in order to display 3.000 for 200mVDC(input).
But it is unable due to setting range is 9.999.
It sets current output for preset display value at the output
current 4-20mA DC.
It sets display value for 4mA in FS.L and 20mA in FS.H
and set range between FS-H and FS-L should be 10%
F.S.(When it set as under 10% F.S., it changed as over
10% F.S. automatically.)Preset display value is fixed to
output as 4mA at under FS-Land 20mA at over FS-H.
Saved setting value
flashes every 0.5 sec.
Press one
IN-R 250V
Mode Setting
value
Ex)
Adjust Low-limit display value
deviation for min. input.
Set range
: -99 to 99
++
--
Decimal point
position
0.000 0.00 0.0 0
Measurement
range
0.100 to
9.999Hz
0.10 to
99.99Hz
0.1 to
999.9Hz
1 to
9999Hz