LC2H Panel mounting type One-touch installation type Panel mounting type Installation frame type PC board mounting type PRODUCT CHART Type DIN HALF SIZE LCD COUNTER Features 8.7mm .343inch 1. 8.7 mm .343 inch Character Height (previously 7 mm) Easy-to-read character height increased from 7 mm to 8.7 mm .276 inch to .343 inch. 2. Plenty of Digits 8 digits 3. Counting Speed Switchable between 2 kHz and 30 Hz 4. Panel Mounting Type Features 2 Installation Methods Comes with very easy one-touch installation type and also installation frame type that uses the bracket on the timer/counter. Choose a method that suits the application. Non-voltage input type LC2H 5. Battery Replacement Easy on Environment To replace battery simply remove body for the one-touch installation type, and remove battery lid for the installation frame type. 6. Screw Terminals Designed for Safety Built in finger protection. 7. Panel Covers Replacable (Standard color is ash gray.) Change the panel design by replacing with a black panel cover. 8. Conforms to IP66 Protective Construction (Only installation frame type.) (Front panel surface) 9. Input Methods 1) Non-voltage input method 2) Voltage input method 3) Free voltage input method 10. Backlight Type Added to Series and Now 2-color Switchable (green/red) Easy viewing even in dark places and switchable between green and red (Voltage input type). 11. Conforms to Safety Regulations Backlight type Voltage input type (4.5 to 30 V DC) Free voltage input type (24 to 240 V AC/DC) One-touch installation type Standard type Voltage input type (4.5 to 30 V DC) Installation frame type Installation type Panel mounting type -- Part No. LC2H-FE-2KK LC2H-FE-DL-2KK LC2H-FE-FV-30 -- Input method Non-voltage input type Voltage input type (4.5 to 30 V DC) Free voltage input type (24 to 240 V AC/DC) -- Front reset Yes Part No. LC2H-FE-DL-2KK-B Counting speed 2 kHz/30 Hz switchable 30 Hz Front reset Yes Input method Voltage input type (4.5 to 30 V DC) PC board mounting type PRODUCT TYPES No. digits 1. Panel mounting type 1) One-touch installation type 1 Standard type 8 digits Counting speed 2 kHz/30 Hz switchable Note) Please ask us about types without front resetting. No. digits 8 digits 2 Backlight type 72 07/2004 No. digits 30 Hz 2 kHz/30 Hz switchable Counting speed 2) Installation frame type 1 Standard type 8 digits Counting speed 2 kHz/30 Hz switchable Note) Please ask us about types without front resetting. 2 Backlight type No. digits 8 digits No. digits Front reset Yes Front reset Yes Front reset Part No. LC2H-F-2KK LC2H-F-DL-2KK LC2H-F-FV-30 LC2H Input method Non-voltage input type Voltage input type (4.5 to 30 V DC) Free voltage input type (24 to 240 V AC/DC) Part No. LC2H-F-DL-2KK-B Part No. LC2H-C-2K-N LC2H-C-30-N Input method Voltage input type (4.5 to 30 V DC) Input method Non-voltage input type 30 Hz (Note 2) No Standard type Backlight type Non-voltage input Voltage input 8 digits Not required (built-in battery) 2 kHz/30 Hz (Switchable by switch) 16.7 ms Standard type Free voltage type 0.25 ms/16.7 ms (Switchable by switch) -- High level: 24 to 240 V AC/DC Low level: 0 to 2.4 V AC/DC Approx. 4.7 k -- High level: 4.5 to 30 V DC Low level: 0 to 2 V DC -- 200 ms 73 Non-voltage input using Non-voltage input using High level: 4.5 to 30 V DC contacts or open collector contacts or open collector Low level: 0 to 2 V DC connection connection When shorted: When shorted: Max. 10 k Max. 10 k Appox. 4.7 k When open: When open: Max. 750 k Max. 750 k Max 0.5 V -- Max. 0.5 V 7-segment LCD 7-segment LCD 7-segment LCD With green/red backlight Between charged and Between charged and uncharged parts: 1,000 V AC for 1 minute. uncharged parts: 2,000 V AC for 1 minute. Min. 100 M (measured at 500 V DC) Measurement location same as for break down voltage. -- 24 V DC (10%) -- IEC Standard IP66 (only panel front: when using rubber gasket) Rubber gasket, mounting bracket 7 years (at 25C 77F) Note 1 6 years (at 25C 77F) When shorted: Max. 10 k When open: Max. 750 k Max. 0.5 V Non-voltage input using contacts or open collector connection Counting speed 2 kHz 30 Hz 2. PC board mounting type 8 digits SPECIFICATIONS 1. Panel mounting type Input impedance Input method (signal) Residual voltage Min. input signal width Input impedance Input method (signal) Type Item No. digits External power supply Max. counting speed Min. input signal width (ON: OFF = 1:1) Count input Reset input Residual voltage Display method Breakdown voltage (initial) Insulation resistance (initial) Backlight power Protective construction (Note 3) Accessories (Note 3) Battery life Notes) 1. The value given for battery life is calculated based on continuous operation (count input signal ON/OFF = 1:1), therefore, this value is not guaranteed. Also, battery life is decreased 30% when operation is continuous with 2 kHz count inputting in 2 kHz mode. 2. Operation is at 25 Hz when using 24 V AC. 3. Only for installation frame type. 07/2004 LC2H 2. PC board mounting type Input impedance Type Residual voltage Min. input signal width Input method Input impedance Type Item Input method No. digits Rated operation voltage Allowable operation voltage range Current consumption Max. counting speed Min. input signal width (ON: OFF = 1:1) Input method Count input Reset input Residual power Break down voltage (initial) Insulation resistance (initial) 3. Common Item Functional Vibration resistance Destructive Functional Shock resistance Destructive Operation temperature Storage temperature Ambient humidity PART NAMES 2 kHz 0.25 ms PC board mounting type Non DC voltage input 8 digits 3 V DC 2.7 to 3.3 V DC Max. 30 A (max. 250 A during reset input) Panel mounting/PC board mounting types LC2H Count speed switch 30 Hz 16.7 ms OFF Non-voltage input/voltage input (Terminal block side) ON -- (Fixed at 30 Hz) (LCD side) 2k Hz 30Hz Lock switch Non-voltage input using contacts or open collector connection When shorted: Max. 10 k When open: Max. 750 k Max. 0.5 V 10 ms Non-voltage input using contacts or open collector connection When shorted: Max. 10 k When open: Max. 750 k Max. 0.5 V Between charged and uncharged parts: 1,000 V AC for 1 minute. Min. 100 M (measured at 500 V DC) Measurement location same as for break down voltage. COUNTER RESET Front reset button Lock switch (Unit display 1) (Terminal block side) (LCD side) Notes) 1. Default setting when shipped. 2. Make the switch setting before installing to panel. Count speed switch (Unit display 2) Free voltage input 10 to 55 Hz (1 cycle/min.), single amplitude: 0.15 mm .006 inch (10 min. on 3 axes) 10 to 55 Hz (1 cycle/min.), single amplitude: 0.375 mm .015 inch (1 hr. on 3 axes) Min. 98 m/s2 (4 times on 3 axes) Min. 294 m/s2 (5 times on 3 axes) -10 to +55C +14 to +131F (without frost or dew) -25 to +65C -13 to +149F (without frost or dew) 35 to 85% RH 1. Front reset button This button resets the count value. It does not work when the lock switch is ON. Be aware that battery life will decrease if this switch is used frequently. 2. Lock switch (Refer to chart on right.) Disable the front reset button. Note) Turn ON at the LCD side (reset disabled) and OFF at the terminal block side (reset enabled). 3. Count speed switch (Refer to chart on right.) Use this switch to switch the count speed between 30 Hz and 2 kHz. (On the nonvoltage and voltage input types, 30 Hz is on the LCD side and 2 kHz is on the terminal block side. Fixed at 30 Hz for free voltage input type.) Note) You must press the front reset button when you change the count speed switch setting. 74 07/2004 Dimensions 10.4 .409 (44) (1.732) 1. Panel mounting type * External dimensions 1) One-touch installation type 22 .866 * Panel installation diagram Panel (1 to 4.5mm .039 to .177inch thickness) 4 54.4 2.142 5 .197 24 .945 7 .276 Rubber spacer 45+0.5 0 1.772+.020 0 Reset input COUNTER RESET 22.2+0.5 0 .874+.020 0 44.8 1.764 48 1.890 LC2H Reset button 1 2 10.4 .409 44 1.732 2) Installation frame type 22 .866 * Panel installation diagram Installation screws (found on mounting bracket) 37 1.457 44.8 1.764 48 1.890 LC2H LC2H mm inch General tolerance: 1.0 .039 54.4 2.142 5 .197 COUNTER RESET Reset button Rubber gasket ATH3804 (included) Mounting bracket ATH3803 (included) 24 .945 7 .276 Panel (1 to 4.5mm .039 to .177inch thickness) 22.2+0.5 0 .874+.020 0 A A=(48xn-2.5)+1.0 0 A=(1.890xn-.098)+.039 0 * When installing repeatedly (sealed installation) (Only mounting bracket installation type.) Reset input +V 4 0V 1 2 3 4 Reset input Free voltage input type Count input or 75 Notes) 1. Suitable installation panel thickness is 1 to 4.5 mm .039 to .177 inch. 2. Waterproofing will be lost when installing repeatedly (sealed installation). 3 Voltage input type Note) When installing to a 4.5 mm .177 inch thick panel, remove the rubber spacer first. * Panel cut-out dimensions 3 0V Count input +V The standard panel cut-out is shown below. Use the mounting bracket (ATH3803) and the rubber packing (ATH3804). (Only mounting bracket installation type.) 60 min. 2.362 min. 2 Non voltage input type * Terminal layout and wiring diagrams 1) Standard type Count input 1 Q-R are connected internally. 07/2004 LC2H 2) Backlight type 1 Count input +V 0V 2 5 6 3 33.020.3 1.300.012 19 .748 4 Reset input Count input 1 2 5 6 0.30.1 .012.004 Reset input 2 3 4 3 4 1 2 6 5 Count input 4 2.54 .100 5.08 .200 5.08 .200 33.02 1.300 17 3 26 1 28 Count input 14 15 12 17 3 26 1 28 3V DC Reset input General tolerance: 1.0 .039 mm inch 1.9 .075 15.24 Connection sockets .600 28 pin DIP terminal 1.9 5.19 .075 .204 Mounting area PC board pattern (BOTTOM VIEW) 2.54 .100 12 Reset input PC board mounting type Transistor input NPN transistor 14 3V DC 15 Contact input 5.19 .204 8-0.8 dia. 8-.031 dia. +V 3 0V Backlight 0V Reset input Non-voltage input type 15.240.3 .600.012 0.50.3 .020.012 1 0V +V Voltage input type 3 26 28 17.3 .681 DIP switch x 8 5.080.3 .200.012 0V Reset input +V 4 2. PC board mounting type * External dimensions 5.080.3 .200.012 0.60.1 .024.004 3.30.3 .130.012 43.4 1.709 LC2H COUNTER 15 17 1 14 12 * Terminal layout and wiring diagrams Count input 3 Transistor input NPN transistor Q-E, }-w, e-t and S-F are connected internally. 2 0V (W and R are connected internally.) Panel mounting type INPUT METHOD 1 Contact input 1. Standard type Count input (W and R are connected internally.) 3 4 Contact input 2 Reset input +V 2 3 4 NPN transistor 1 +V Transistor input +V Reset input Voltage input type Count input 1 2 3 4 PNP transistor Count input +V Reset input or 1 2 3 4 Free voltage input type or or Notes) 1. When using contact input, since current flow is small from terminals 1 and 3 on the panel mounting type and terminals e to t and S to F on the PC board mounting type, please use relays and switches with high contact reliability. 2. When using transistor input, use the following as a guide for which transistors (Tr) to use for inputting. (Collector withstand voltage Q 50 V, leakage current < 1 A) Count input 1 Reset input 76 07/2004 Notes) 1. 2 and 4. (The input and reset circuits are functionally insulated.) 2. When using transistor (Tr) input, use the right as a guide. (Collector withstand voltage Q 50 V, leakage current < 1 A) 3. Be aware that the application of voltage that exceeds the voltage range of the H level to the count input terminal, and the application of voltage to the reset input terminal, can cause damage to the internal elements. Count input 2 6 5 3 4 Contact input 2. Backlight type Count input 1 Reset input 0V Count input 2 5 3 4 +V NPN transistor Voltage input type +V 1 6 +V Transistor input Reset input 0V Count input Reset input Count value 1 2 6 5 3 4 PNP transistor Count input 1 mm2). When using 2 kHz mode, use with a wiring floating capacitance of 120 pF (3 m 9.843 ft. for parallel wires of 2 mm2). In particular, when using shielded wiring, be careful of the capacitance between wires. PC board mounting type 1) For external power supply use manganese dioxide or lithium batteries (CR type: 3V). 2) Always reset after external power is applied and confirm that the display reads "0". 3) Make the wiring from the battery to the counter unit as short as absolutely possible. Also, be careful of polarity. 4) Calculate battery life with the following formula. t = A/I t: battery life [h] I: LC2H current consumption [mA] A: battery capacity until minimum operation voltage is reached [mAh] 5) Hand solder to the lead terminal. Do not dip solder. With the tip of the soldering iron at 300C 572F perform soldering within 3 seconds (for 30 to 60 W soldering iron). 2. Voltage input type 1) Be aware that applying more than 30 V +V Reset input 99999999 1 0 4 24V DC 3 1 2 3 4 LC2H Red 5 6 24V DC Backlight connection 5 Green 2 6 1 0 1 77 DC to count input terminals 1 and 2, and reset input terminals 3 and 4 will cause damage to the internal elements. 2) For external resetting use H level (application of 4.5 to 30 V DC) between reset terminals 3 and 4 of the rear terminals. In this case, connect + to terminal 3 and - to terminal 4. This is the valid polarity; therefore, the counter will not work if reversed. 3) When wiring, try to keep all the input lines to the count and reset inputs as short as possible and avoid running them together with high voltage and power transmission lines or in a power conduit. Also, malfunctions might occur if the floating capacitance of these wires exceeds 500 pF (10 m 32.808 ft. for parallel wires of 2 mm2). 3. Free voltage input type 1) Use count input terminals 1 and 2 for free voltage input and reset terminals 3 and 4 for non-voltage input. 2) Be aware that the application of voltage that exceeds the voltage range of the H level to the count input terminal, and the application of voltage to the reset input terminal, can cause damage to the internal elements. Note) Count becomes "1" when the reset input is turned OFF while the count signal is being input. 0 Notes) 1. Do not reverse the polarities when connecting the DC voltage for the backlight. 2. 2 and 4. (The input and reset circuits are functionally insulated.) 3. When using transistor (Tr) input, use the right as a guide. (Collector withstand voltage Q 50 V, leakage current < 1 A) 4. Be aware that the application of voltage that exceeds the voltage range of the H level to the count input terminal, and the application of voltage to the reset input terminal, can cause damage to the internal elements. Explanation of operation 1. Counting takes place when the count input signal is ON. 2. Counting resumes again when the count value reaches 99999999 (full scale value) and then returns to "0" with a new count input. 3. No measurement takes place when a reset is input. 1) When reset is ON, resetting takes place and the count becomes "0". 2) Press the front reset button when you want to reset manually (only panel installation type). Note) Be aware that battery life will decrease if the count input or reset input are left ON. Cautions for use 1. Non-voltage input type For both panel mounting and PC board mounting types 1) Never apply voltage to the non-voltage input type. This will damage the internal elements. Also, since there is a possibility of erroneous operation, do not connect in parallel the inputs of a non-voltage input type and another counter from a single input signal. 2) Since the current flow is very small from the count input and reset input terminals (1 and 3 on the panel mounting type and terminals e to t and S to F on the PC board mounting type) please use relays and switches with high contact reliability. 3) When inputting with an open collector of a transistor, use a transistor for small signals in which ICBO is 1 A or less and always input with no voltage. 4) When wiring, try to keep all the input lines to the count and reset inputs as short as possible and avoid running them together with high voltage and power transmission lines or in a power conduit. Also, malfunctions might occur if the floating capacitance of these wires exceeds 500 pF (10 m 32.808 ft. for parallel wires of 2 07/2004 LC2H 3 4 D 3 4 D 3 4 Tr or 3) Since the current flow is very small from reset input terminal 3, please use relays and switches with high contact reliability. 4) When inputting a reset with an open collector of a transistor, use a transistor for small signals in which ICBO is 1 A or less and always input with no voltage. 5) To reset externally, short reset input terminals 3 and 4 on the rear. 6) Input uses a high impedance circuit; therefore, erroneous operation may occur if the influence of induction voltage is present. If you plan to use wiring for the input signal that is 10 m or longer (wire capacitance 120 pF/m at normal temperature), we recommend the use of a CR filter or the connection of a bleeder resistor. 4. How to reset multiple panel mounting type counters all at once (input is the same for count) Non-voltage input type D 3 4 R Tr +V or 3 4 +V Notes) 1. Use the following as a guide for choosing transistors used for input (Tr). Leakage current < 1 A 2. Use as small a diode (D) as possible in the forward voltage so that the voltage between terminals 3 and 4 during reset input meets the standard value (0.5 V). ( At IF = 20 A, forward voltage 0.1 and higher.) 3 4 Voltage input type 3 4 Note) Make sure that H (reset ON) level is at least 4.5 V. 2 5 2 5 2 6 Red 2 6 24V DC 5. Backlight luminance To prevent varying luminance among backlights when using multiple Backlight types, please use the same backlight power supply. 24V DC Green 6. Insulation sheet Before using a panel mounting type, please pull and remove the insulation sheet from the side of the product in the direction of the arrow. In consideration that the product might be stored for long periods without being used, an insulation sheet is inserted before shipping. Remove the insulation sheet and press the front reset button. 78 07/2004