AQ-R
ORDERING INFORMATION
High capacity SSR,
both tab and screw
terminals available
AQ-R RELAYS
(10A, 15A, 20A type) (30A, 40A type)
Compliance with RoHS Directive
FEATURES
1. Two types of terminal shape: Plug-in
terminal and Screw terminal (30 A, 40
A is screw terminal types only)
2. Flat type of SSR possible by
aluminium printed circuit board
3. High dielectric strength of 1,500 V
between input and output. 4,000 V
available for 10A, 15A, 20A devices.
4. Heat sink and DIN mounting rail and
terminal cover are available as
accessories
APPLICATIONS
1. Molding machine (heater control)
2. Temperature controlled bath (heater
control)
3. Printing machine (heater control)
4. Machine tool (motor control)
AQR Solid state Relay
Load current
10 A
15 A
20 A
30 A
40 A
AQR
Load voltage
1: 75 to 125 V AC
2: 75 to 250 V AC
Terminal shape
Nil:
S:
Plug-in terminal
Screw terminal
Type
Z:
ZV:
Input voltage
4/6 V DC
10/18 V DC
18/28 V DC
Zero-cross type (1,500 V)
Zero-cross type (4,000 V)
All Rights Reserved © COPYRIGHT Panasonic Electric Works Co., Ltd.
AQ-R
TYPES
1. Tab terminal type
Standard packing: Carton 10 pcs., Case: 100 pcs.
2. Screw-terminal type
Standard packing: Carton 10 pcs., Case: 100 pcs.
Type Load current Load voltage Input voltage Standard (1,500V AC) Reinforced (4,000V AC)
Part No. Part No.
Zero-cross
10 A
75 to 125V AC
4 to 6V DC AQR10A1-Z4/6VDC
10 to 18V DC AQR10A1-Z10/18VDC
18 to 28V DC AQR10A1-Z18/28VDC
75 to 250V AC
4 to 6V DC AQR10A2-Z4/6VDC AQR10A2-ZV4/6VDC
10 to 18V DC AQR10A2-Z10/18VDC AQR10A2-ZV10/18VDC
18 to 28V DC AQR10A2-Z18/28VDC AQR10A2-ZV18/28VDC
15 A
75 to 125 V AC
4 to 6V DC AQR15A1-Z4/6VDC
10 to 18V DC AQR15A1-Z10/18VDC
18 to 28V DC AQR15A1-Z18/28VDC
75 to 250 V AC
4 to 6V DC AQR15A2-Z4/6VDC AQR15A2-ZV4/6VDC
10 to 18V DC AQR15A2-Z10/18VDC AQR15A2-ZV10/18VDC
18 to 28V DC AQR15A2-Z18/28VDC AQR15A2-ZV18/28VDC
20 A
75 to 125 V AC
4 to 6V DC AQR20A1-Z4/6VDC
10 to 18V DC AQR20A1-Z10/18VDC
18 to 28V DC AQR20A1-Z18/28VDC
75 to 250 V AC
4 to 6V DC AQR20A2-Z4/6VDC AQR20A2-ZV4/6VDC
10 to 18V DC AQR20A2-Z10/18VDC AQR20A2-ZV10/18VDC
18 to 28V DC AQR20A2-Z18/28VDC AQR20A2-ZV18/28VDC
Type Load current Load voltage Input voltage Standard (1,500V AC) Reinforced (4,000V AC)
Part No. Part No.
Zero-cross
10 A
75 to 125 V AC
4 to 6V DC AQR10A1-S-Z4/6VDC
10 to 18V DC AQR10A1-S-Z10/18VDC
18 to 28V DC AQR10A1-S-Z18/28VDC
75 to 250 V AC
4 to 6V DC AQR10A2-S-Z4/6VDC AQR10A2-S-ZV4/6VDC
10 to 18V DC AQR10A2-S-Z10/18VDC AQR10A2-S-ZV10/18VDC
18 to 28V DC AQR10A2-S-Z18/28VDC AQR10A2-S-ZV18/28VDC
15 A
75 to 125 V AC
4 to 6V DC AQR15A1-S-Z4/6VDC
10 to 18V DC AQR15A1-S-Z10/18VDC
18 to 28V DC AQR15A1-S-Z18/28VDC
75 to 250 V AC
4 to 6V DC AQR15A2-S-Z4/6VDC AQR15A2-S-ZV4/6VDC
10 to 18V DC AQR15A2-S-Z10/18VDC AQR15A2-S-ZV10/18VDC
18 to 28V DC AQR15A2-S-Z18/28VDC AQR15A2-S-ZV18/28VDC
20 A
75 to 125 V AC
4 to 6V DC AQR20A1-S-Z4/6VDC
10 to 18V DC AQR20A1-S-Z10/18VDC
18 to 28V DC AQR20A1-S-Z18/28VDC
75 to 250 V AC
4 to 6V DC AQR20A2-S-Z4/6VDC AQR20A2-S-ZV4/6VDC
10 to 18V DC AQR20A2-S-Z10/18VDC AQR20A2-S-ZV10/18VDC
18 to 28V DC AQR20A2-S-Z18/28VDC AQR20A2-S-ZV18/28VDC
30 A 75 to 250 V AC
4 to 6V DC AQR30A2-S-Z4/6VDC
10 to 18V DC AQR30A2-S-Z10/18VDC
18 to 28V DC AQR30A2-S-Z18/28VDC
40 A 75 to 250 V AC
4 to 6V DC AQR40A2-S-Z4/6VDC
10 to 18V DC AQR40A2-S-Z10/18VDC
18 to 28V DC AQR40A2-S-Z18/28VDC
All Rights Reserved © COPYRIGHT Panasonic Electric Works Co., Ltd.
AQ-R
SPECIFICATIONS
1. Ratings (at 20°C 68°F, Input ripple: 1% or less)
1) 10 A type
2) 15 A type
Notes: *1. Refer to REFERENCE DATA “3. Input current vs. input voltage”.
*2. Refer to REFERENCE DATA “1. Load current vs. ambient temperature”.
*3. Refer to REFERENCE DATA “2. Non-repetitive surge current vs. carrying time”.
*4. When the load current is less than the rated minimum load current, please refer to “Cautions for Use of SSR”.
Part No.
Items
AQR10A1-Z4/
6VDC
AQR10A1-S-Z4/
6VDC
AQR10A1-Z10/
18VDC
AQR10A1-S-Z10/
18VDC
AQR10A1-Z18/
28VDC
AQR10A1-S-Z18/
28VDC
AQR10A2-Z4/
6VDC
AQR10A2-ZV4/
6VDC
AQR10A2-S-Z4/
6VDC
AQR10A2-S-ZV4/
6VDC
AQR10A2-Z10/
18VDC
AQR10A2-ZV10/
18VDC
AQR10A2-S-Z10/
18VDC
AQR10A2-S-
ZV10/18VDC
AQR10A2-Z18/
28VDC
AQR10A2-ZV18/
28VDC
AQR10A2-S-Z18/
28VDC
AQR10A2-S-
ZV18/28VDC
Remarks
Input
side
Input voltage 4 to 6V DC 10 to 18V DC 18 to 28V DC 4 to 6V DC 10 to 18V DC 18 to 28V DC
*1
Input impedance Approx. 0.26 kApprox. 0.86 kApprox. 1.36 kApprox. 0.26 kApprox. 0.86 kApprox. 1.36 k
Drop-out voltage,
min. 1 V
Load
side
Max. load current 10 A*2Ta = Max. 40°C
104°F
Load voltage 75 to 125 V AC 75 to 250 V AC
Frequency 45 to 65 Hz
Repetitive peak
voltage 400 V 600 V
Non-repetitive
surge current 100 A*3In one cycle at
60 Hz
Max. “OFF-state”
leakage current 2.5 mA (when 100 V AC applied) 5 mA (when 200 V AC applied) at 60 Hz
Max. “ON-state”
voltage drop 1.6 V at max.
carrying current
Min. load current 100 mA*4
OFF-state dV/dt 100 V/µs
Part No.
Items
AQR15A1-Z4/
6VDC
AQR15A1-S-Z4/
6VDC
AQR15A1-Z10/
18VDC
AQR15A1-S-Z10/
18VDC
AQR15A1-Z18/
28VDC
AQR15A1-S-Z18/
28VDC
AQR15A2-Z4/
6VDC
AQR15A2-ZV4/
6VDC
AQR15A2-S-Z4/
6VDC
AQR15A2-S-ZV4/
6VDC
AQR15A2-Z10/
18VDC
AQR15A2-ZV10/
18VDC
AQR15A2-S-Z10/
18VDC
AQR15A2-S-
ZV10/18VDC
AQR15A2-Z18/
28VDC
AQR15A2-ZV18/
28VDC
AQR15A2-S-Z18/
28VDC
AQR15A2-S-
ZV18/28VDC
Remarks
Input
side
Input voltage 4 to 6V DC 10 to 18V DC 18 to 28V DC 4 to 6V DC 10 to 18V DC 18 to 28V DC
*1
Input impedance Approx. 0.26 kApprox. 0.86 kApprox. 1.36 kApprox. 0.26 kApprox. 0.86 kApprox. 1.36 k
Drop-out voltage,
min. 1 V
Load
side
Max. load current 15 A*2Ta = Max. 40°C
104°F
Load voltage 75 to 125 V AC 75 to 250 V AC
Frequency 45 to 65 Hz
Repetitive peak
voltage 400 V 600 V
Non-repetitive
surge current 150 A*3In one cycle at
60 Hz
Max. “OFF-state”
leakage current 2.5 mA (when 100 V AC applied) 5 mA (when 200 V AC applied) at 60 Hz
Max. “ON-state”
voltage drop 1.6 V at max.
carrying current
Min. load current 100 mA*4
OFF-state dV/dt 100 V/µs
All Rights Reserved © COPYRIGHT Panasonic Electric Works Co., Ltd.
AQ-R
3) 20 A type
4) 30 A type and 40 A type
Notes: *1. Refer to REFERENCE DATA “3. Input current vs. input voltage”.
*2. Refer to REFERENCE DATA “1. Load current vs. ambient temperature”.
*3. Refer to REFERENCE DATA “2. Non-repetitive surge current vs. carrying time”.
*4. When the load current is less than the rated minimum load current, please refer to “Cautions for Use of SSR”.
2. Characteristics (at 20°C 68°F, Input ripple: 1% or less)
Note: *30A and 40A type is 10 to 55 Hz at double amplitude of 1.5 mm .059 inch.
Part No.
Items
AQR20A1-Z4/
6VDC
AQR20A1-S-Z4/
6VDC
AQR20A1-Z10/
18VDC
AQR20A1-S-Z10/
18VDC
AQR20A1-Z18/
28VDC
AQR20A1-S-Z18/
28VDC
AQR20A2-Z4/
6VDC
AQR20A2-ZV4/
6VDC
AQR20A2-S-Z4/
6VDC
AQR20A2-S-ZV4/
6VDC
AQR20A2-Z10/
18VDC
AQR20A2-ZV10/
18VDC
AQR20A2-S-Z10/
18VDC
AQR20A2-S-
ZV10/18VDC
AQR20A2-Z18/
28VDC
AQR20A2-ZV18/
28VDC
AQR20A2-S-Z18/
28VDC
AQR20A2-S-
ZV18/28VDC
Remarks
Input
side
Input voltage 4 to 6V DC 10 to 18V DC 18 to 28V DC 4 to 6V DC 10 to 18V DC 18 to 28V DC
*1
Input impedance Approx. 0.26 kApprox. 0.86 kApprox. 1.36 kApprox. 0.26 kApprox. 0.86 kApprox. 1.36 k
Drop-out voltage,
min. 1 V
Load
side
Max. load current 20 A*2Ta = Max. 40°C
104°F
Load voltage 75 to 125 V AC 75 to 250 V AC
Frequency 45 to 65 Hz
Repetitive peak
voltage 400 V 600 V
Non-repetitive
surge current 200 A*3In one cycle at
60 Hz
Max. “OFF-state”
leakage current 2.5 mA (when 100 V AC applied) 5 mA (when 200 V AC applied) at 60 Hz
Max. “ON-state”
voltage drop 1.6 V at max.
carrying current
Min. load current 100 mA*4
OFF-state dV/dt 100 V/µs
Part No.
Items
AQR30A2-S-Z4/
6VDC
AQR30A2-S-Z10/
18VDC
AQR30A2-S-Z18/
28VDC
AQR40A2-S-Z4/
6VDC
AQR40A2-S-Z10/
18VDC
AQR40A2-S-Z18/
28VDC Remarks
Input
side
Input voltage 4 to 6V DC 10 to 18V DC 18 to 28V DC 4 to 6V DC 10 to 18V DC 18 to 28V DC
*1
Input impedance Approx. 0.26 kApprox. 0.86 kApprox. 1.36 kApprox. 0.26 kApprox. 0.86 kApprox. 1.36 k
Drop-out voltage,
min. 1 V
Load
side
Max. load current 30 A*240 A*2Ta = Max. 40°C
104°F
Load voltage 75 to 250 V AC
Frequency 45 to 65 Hz
Non-repetitive
surge current 300 A*3400 A*3In one cycle at
60 Hz
Max. “OFF-state”
leakage current 5 mA (when 200 V AC applied) at 60 Hz
Max. “ON-state”
voltage drop 1.6 V at max.
carrying current
Min. load current 120 mA*4
Type Zero-cross type Remarks
Item Standard type Reinforced type
Operate time, max. 1/2 cycle of voltage sine wave + 1 ms
Release time, max. 1/2 cycle of voltage sine wave + 1 ms
Insulation resistance, min., Initial 100 M between input, output and case at 500V DC
Breakdown voltage 1,500 V AC between input, output and case 4,000 V AC between input, output and case For 1 min.
Vibration
resistance
Functional 10 to 55 Hz at double amplitude of 2 mm* 1 hour for X, Y, Z axes
Destructive 10 to 55 Hz at double amplitude of 2 mm* 10 minutes for X, Y, Z axes
Shock
resistance
Functional Min. 980 m/s2 {100 G} 5 time each for X, Y, Z axes
Destructive Min. 980 m/s2 {100 G} 4 time each for X, Y, Z axes
Ambient temperature –20°C to +80°C –4°F to +176°F
Storage temperature –25°C to +85°C –13°F to +185°F
Operational method Zero-cross (Turn-ON and Turn-OFF)
All Rights Reserved © COPYRIGHT Panasonic Electric Works Co., Ltd.
AQ-R
REFERENCE DATA
1. Load current vs. ambient temperature
Use load current within range specified in the figure below.
Tested condition:
With external heat sink
1) (1) 10 A, 15A, 20 A type
• A heat sink; optional heat sink (AQP-HS-
J10A) or a 150×150×3.2 mm aluminum
sheet (painted black)
(2) 30 A, 40 A type
Shown with standard heat sink (AQP-HS-30/
40A)
2) If attached to a heat sink, use a heat-
conductive compound or similar coating to
improve cooling.
Without external heat sink
If the mounting surface is not metallic and a
heat sink is not used, expose the bottom
surface and plate surface to improve heat
dissipation.
The graphs show the characteristics when the
relay is mounted as shown in the right figure.
(1) 10 A type
;;
;;
;
;
;;
;
;;
;;;
;;;
;;;
;;;
;;
Washers are added
to lift the relay.
Hole for radiation
(40×35 mm)
3 mm or
greater
0
–30 0 20 40 60 80
10
8
6
4
2
Ambient temperature °C
Load current, A
Without external heat sink
With external
heat sink
(2) 15 A type (3) 20 A type (4) 30 A type
–30 0 20 40 60 80
20
16
12
8
4
0
Ambient temperature, °C
Load current, A
2
7
6
15
With external
heat sink
Without external heat sink
–30 0 20 40 60 80
20
16
12
8
4
2
0
Ambient temperature, °C
Load current, A
With external
heat sink
Without external heat sink
30
40
50
20
10
00–30 20 40 60 80
Without external heat sink
Ambient temperature, °C
Load current, A
With external
heat sink
(5) 40 A type 2-1. Non-repetitive surge current vs. carrying
time (10 A type)
2-2. Non-repetitive surge current vs. carrying
time (15 A type)
30
40
50
20
10
00–30 20 40 60 80
Ambient temperature, °C
Load current, A
Without external heat sink
With external
heat sink
1234571020 304050 70100
No. of cycles at 60 Hz
Non-repetitive surge current, A
20
0
40
60
80
100
120
140
160
180
200
220
1234571020 304050 70100
No. of cycles at 60 Hz
Non-repetitive surge current, A
20
0
40
60
80
100
120
140
160
180
200
220
2-3. Non-repetitive surge current vs. carrying
time (20 A type)
2-4. Non-repetitive surge current vs. carrying
time (30 A, 40 A type)
3. Input current vs. input voltage
(10 A, 15 A, 20 A, 30 A, 40 A common)
1234571020 304050 70100
No. of cycles at 60 Hz
Non-repetitive surge current, A
20
0
40
60
80
100
120
140
160
180
200
220
0
100
200
300
400
500
1234571020 304050 70 100
40A type
30A type
No. of cycles at 60 Hz
Non-repetitive surge current, A
30
25
20
15
10
5
0
Input voltage, V
Input current, mA
015
510 202530
(4 to 6 V) (10 to 18 V)
(18 to 28 V)
All Rights Reserved © COPYRIGHT Panasonic Electric Works Co., Ltd.
AQ-R
DIMENSIONS (mm inch)
ACCESSORIES
The CAD data of the products with a CAD Data mark can be downloaded from: http://panasonic-electric-works.net/ac
1. Tab terminal
Conform to AMP plug-in terminal
#110 series receptacle
Mounting hole
Conform to AMP plug-in terminal
#250 series receptacle
9
Max. 7.5
Max. 12.5
Max. 15
59
47.6
44.8
26
2-4.4 dia.
.354
Max. .295
Max. .492
Max. .591
2.323
1.874
1.764
1.024
2-.173 dia.
Schematic
Mounting dimensions
(Bottom view)
Load power
source
1
2
4
3
Input power
source
+
_Load
2-4.3 dia. or M4
47.6±0.1
2-.169 dia.
1.874±.004
CAD Data
2. Screw terminal
Mounting hole
4-M4
screw terminal
9
Max. 7.5
max. 12.5
Max. 17
59
47.6
45.0
44.8
26
2-4.4 dia.
.354
Max. .295
Max. .492
Max. .669
2.323
1.874
1.772
1.764
1.024
2-.173 dia.
Schematic
Mounting dimensions
(Bottom view)
Load power
source
1
2
4
3
Input power
source
+
_Load
2-4.3 dia. or M4
47.6±0.1
2-.169 dia.
1.874±.004
CAD Data
Heat sink (For 10 A, 15A and 20 A)
AQP-HS-J10A
90
R2.2
3-M4
4.4
3.543
.173
4.4
.173 .087
47.6
100
1.874
30
1.181
3.937
50
1.969
1.5
2
11.1
1.5
9
.059
.079
2
.079
.437
.059
.354
54
2.126
45
1.772
28.5
1.122
24.5
.965
33.3
1.311
80
3.150
100+0.5
1.5
+.020
.059
3.937
Mounting dimensions
(Bottom view)
50±0.2
1.969±.008
4-M4 or 4.4 dia.
90±0.1
3.543±.004
General tolerance: ±0.5 ±.020
CAD Data
All Rights Reserved © COPYRIGHT Panasonic Electric Works Co., Ltd.
AQ-R
Heat sink (For 30 A, 40 A)
AQP-HS-30/40A
90
4.4 4.4
50
54 100+0.5
1.5
3.937+.020
.059
80
33.3
47.6
56
150 24.5
1.5
2
2
11.1
1.5
28.5
45
9
R 2.2 .087
3-M4
3.543
.173 .173
1.969
2.126
3.150
1.311
1.874
2.205
5.906 .965
.059
.079
.079
.437
.059
1.122
1.772
.354
Mounting dimensions
(Bottom view)
50±0.2
1.969±.008
4-M4 or 4.4 dia.
90±0.1
3.543±.004
General tolerance: ±0.5 ±.020
CAD Data
With terminal cover
AQP-PC
59
11.5
47
24.5
1.5
5.5
1.5
2.323
.453
1.850
.965
.059
.217
.059
General tolerance: ±0.5 ±.020
CAD Data
DIN rail mounting plate
AQP-DP
86
44
18.1
M4
70
56
47.6
13.6
M4
M4
3.386
1.732
.713
2.765
2.205
1.874
.535
Mounting rail
AT8-DLA1
15
5 5
10
1,000
5.5
35
1.5
27
24
15
40-5.5×15 slot
15 10 15
7.5
2.75R
.591
.197 .394
39.37
.217
1.378
.059
1.063
.945
.591 .591 .394 .591.108R
.295
.197
40-.217×.591 slot
General tolerance: ±0.5 ±.020
CAD Data CAD Data
All Rights Reserved © COPYRIGHT Panasonic Electric Works Co., Ltd.
AQ-R
Recommended Temperature Controllers
For Cautions for Use.
Fastening plate
ATA4806
12
50
M4
10
10
ATA4806
UP
.472
1.969
.394
.394
CAD Data
48mm
56mm
1.890inch
2.205inch
48mm
1.890inch
<KT4H Temperature Controller>
Our temperature controller is recommended for use with our Solid State Relays.
Features
• Data can be collected using the RS485 communications interface via a PLC.
• Improved visibility using a negative type LCD and backlight.
• Depth-wise length (chassis dimension) is 56 mm 2.205 inch.
Substitute part numbers
*For detailed product information about temperature controllers, please refer to our website:
http://panasonic-denko.co.jp/ac/e/fasys/component/temperature_controller/
Power supply Control output Part No.
100 to 240 V AC Relay contact AKT4H111100