safety light curtains
D
For the Latest Information
On the Internet: www.sti.com or www.omron.ca
OMRON SCIENTIFIC TECHNOLOGIES, INC.
USA Tel. 1/888/510-4357 Canada Tel. 1/866/986-6766
D6
AGo to the Engineering Guide
For in-depth information on
safety standards and use.
F3SJ-A
F3SJ-A
Safety Light Curtain
n Resolution: 14 mm (0.55 in.),
20 mm (0.79 in.), 30 mm
(1.18 in.), or 55 mm (2.17 in.)
n Range: 7 m (23 ft.) or 9 m
(29.5 ft.) dependent on
minimum object resolution and
protected height
n Protected heights: 14 mm pro-
tected heights from 245 to 1631
mm (9.6 to 64 in.), 20 mm and
30 mm protected heights from
245 to 2495 mm (9.6 to 98 in.),
55 mm from 270 to 2470 mm
(10.6 to 97 in.)
n Very compact size – 30 x 24 mm
(1.18 x 0.94 in.)
n Cascaded designs possible –
4 segments, up to 400 beams
n Warning zone function
n Partial muting
n Position detection muting
n Fixed blanking
n Floating blanking – up to four
beams
n External Device Monitoring
n Two PNP safety outputs
n One NPN auxiliary output
n Cross-talk prevention
n Range selection
Options
n Handheld setting console
n SD manager programming
software
n F3SP/F3SX Safety Controller
n Weld shields
n IP67 enclosures
n Multiple mounting options
n Description
The F3SJ-A system is a full-
featured safety light curtain that
meets demanding and complex
guarding requirements.
Inside its compact housing the
F3SJ-A combines several features
which allow it to be used in a
variety of ways. These features in-
clude a warning zone function, as
well as fixed and floating blank-
ing. Also included is a valuable
feature known as “partial muting”.
For complete safety, External
Device Monitoring (EDM) is
included and cross-talk preven-
tion features are standard.
For ease of use, the F3SJ-A can
be configured by using either a
handheld setting console or by
connecting to a computer running
the convenient and comprehen-
sive SD Manager programming
software.
R
C US
safety light curtains
D
For the Latest Information
On the Internet: www.sti.com or www.omron.ca
OMRON SCIENTIFIC TECHNOLOGIES, INC.
USA Tel. 1/888/510-4357 Canada Tel. 1/866/986-6766
D7
F3SJ-A
Muting Functions
Muting temporarily disables the
F3SJ-A when an object must pass
through the detection zone, such
as when supplying a workpiece to
your equipment.
Partial muting increases the
level of safety by only muting the
beams of the safety light curtain
where the workpiece passes
through, while preventing muting
in all other areas.
Warning Zone Function
With the F3SJ-A part of the
detection zone can be used as
warning zone to generate an
alarm when someone approaches
the danger zone. If the person
then enters the danger zone the
F3SJ-A will send a stop signal to
the guarded machine. In addition,
the auxiliary output can be used
to activate a flashing lamp to alert
the person in the warning zone.
The detection zone for a single
F3SJ-A can be divided into two
zones or set a single warning zone
for multiple, cascaded F3SJ-A
units.
Convenient Serial Connection
Sensors with protected heights
of almost 2.5 m are available. If
you want to make changes in the
future, you can always extend
the protective height with series
connections. Up to four sets (400
beams) can be series connected
and with series-connection cables
up to 15 m in length, applications
can cover a wide area.
Position detection muting
is used in applications where
the workpiece is set in position
each time by an operator, and
a turntable or positioning robot
then moves the workpiece to the
area where the work is performed.
A limit switch or other means is
used to detect when the robot is in
a safe position and muting is then
applied.
The safety light curtain beams
in all areas other than where the
workpiece passes through are
constantly ON.
Only the beams of the safety
light curtain interrupted by the
workpiece are muted.
Detection zone
Warning zone
Detection zone
Warning zone
Dividing the zone between series-connected sensors
A single sensor can also be divided
20 mm gap between end beams when
connected side by side
25 mm
Series connection cable
up to 15 m long
Total length:
Approx. 10 m
(400 beams)
Approx. 2.5 m
(100 beams)
20 mm gap between end beams when
connected side by side
25 mm
Series connection cable
up to 15 m long
Total length:
Approx. 10 m
(400 beams)
Approx. 2.5 m
(100 beams)
safety light curtains
D
For the Latest Information
On the Internet: www.sti.com or www.omron.ca
OMRON SCIENTIFIC TECHNOLOGIES, INC.
USA Tel. 1/888/510-4357 Canada Tel. 1/866/986-6766
D8
AGo to the Engineering Guide
For in-depth information on
safety standards and use.
Programming Options
Using the SD Manager software,
all features of the F3SJ-A can be
set and checked. Features include:
n Display of system specifications:
Model
Number of beams
Minimum object resolution
Response time
n Settings for:
Fixed blanking
Floating blanking
Warning zone configuration
Muting – Both partial and
position detection
External indicator function
Auxiliary outputs
EDM parameters
Operating range
n Monitoring of received and
ambient light intensity
n Maintenance information:
Power on time
OSSD switching frequency
n Recovery of settings
n Safety distance calculations
based on parameters for con-
nected system
When you don’t want to take a
computer into the field with you
the F39-MC21 setting
console is a convenient
way to set parameters
and check the system
status.
n Description (continued)
“SD Manager” PC Setting Software
F3SJ-A
Branch
Connector
Connection Cable
To a USB terminal
All parameters can be set and the system status can be checked with a
personal computer. In addition to making it easy to monitor the beam
alignment, the ambient incident light intensity can be displayed in bar
graph form for an easy check of the system status.
F39-GWUM
“SD Manager”
PC Setting Software
Setting Console
F39-MC21
Setting Console
for the F3SJ-A
F3SJ-A
safety light curtains
D
For the Latest Information
On the Internet: www.sti.com or www.omron.ca
OMRON SCIENTIFIC TECHNOLOGIES, INC.
USA Tel. 1/888/510-4357 Canada Tel. 1/866/986-6766
D9
With built-in muting and blank-
ing functions, the F3SJ-A is can be
employed in a wide variety of ap-
plications from robotic work cells
to small machines. The potential
for cascaded design and a broad
selection of minimum object
resolutions adds to this versatility.
n Applications
F3SJ-A
Space Efficient and Low Cost
The built-in external device monitoring function
eliminates the need for a safety relay unit.
No Safety Relay Unit
F39-JC®A
G7SA
A welded contact
detection circuit can
be created using two
force-guided relays.
Contactor Motor
Connector Type
Reduced Wiring and Easy Maintenance
Cables with connectors on both ends simplify
connections and prevent wiring errors.
F39-JC®B
F3SP-B1P
Dedicated controller
Contactor Motor
Selecting the Best Configuration
Multi-input Safety Circuit Configuration
When an emergency stop or door switch is used in conjunction with
the F3SJ-A, the safety circuit becomes more complex. The F3SX
safety controller is one possible solution. Four models are available
to match your desired inputs and outputs. Use an F39-CN5 branch
connector to significantly reduce the time required to make the
proper connections.
F39-JC®T
Connector cable
for F3SX use
Emergency
stop switch
Relays with force-guided contacts
Branch connector
F39-ON5
F39-JC®B
Connector cable for F3SX use
F3SX
safety light curtains
D
For the Latest Information
On the Internet: www.sti.com or www.omron.ca
OMRON SCIENTIFIC TECHNOLOGIES, INC.
USA Tel. 1/888/510-4357 Canada Tel. 1/866/986-6766
D10
AGo to the Engineering Guide
For in-depth information on
safety standards and use.
F3SJ-A
n Wiring
Emitter
F39-JC@A-L F39-JC@A-D
Receiver
OUT
PLC
IN
Communication
line (+) (Gray)
Communication
line () (Pink)
Shield
0 V (Blue)
Auxiliary output 2 (Red)
S1
S2
Test input (Green)
Reset input (Yellow)
Interlock selection input (White)
+24 V (Brown)
+24 V (Brown)
External device monitoring input (Red)
KM1
KM2
Auxiliary output 1 (Yellow)
Control output 1 (Green)
Control output 2 (White)
0 V (Blue)
Shield
E1
+24 VDC
0 V
M
KM2
KM1
KM4
Light incident
Light interrupted
External test switch (S1)
Reset switch (S2)
Control output
KM1,KM2 N.O. contact
KM1,KM2 N.C. contact
PLC input (See note.)
PLC output
KM2KM1
KM3
Wiring for Single F3SJ-A Application
Detection of a welded relay contact is possible without a controller relay unit.
Manual reset mode
Using external device monitoring function
safety light curtains
D
For the Latest Information
On the Internet: www.sti.com or www.omron.ca
OMRON SCIENTIFIC TECHNOLOGIES, INC.
USA Tel. 1/888/510-4357 Canada Tel. 1/866/986-6766
D11
F3SJ-A
Wiring when safety light curtain
F3SJ is not used
L2 Module
Emitter Receiver
F3SJ (1st unit)
Model F39-JC@A-L
cable for emitter
Model F39-JC@A-D
cable for receiver
Communication
line (+) (Gray)
Communication
line () (Pink)
Shield 0 V (Blue)
2 754318 6
15 10121314169 11
Auxiliary output 2 (Red)
Open
Test input (Green)
Reset input (Yellow)
Interlock selection input (White)
24 VDC (Brown)
24 VDC (Brown)
External device
monitoring input (Red)
Auxiliary output 1 (Yellow)
Control output 1 (Green)
Control output 1 (White)
0 V (Blue)
Shield
Main Module
S1
S2
11
12 22
21
24 VDC
E1
A1 T11 T12 T21 T22 Y1 Y2 Y3
Control Circuit
24 VDC
E1
A2
24 VDC
24 VDC
COM
0 V
SSC AS3 AS2 AS1 SS1 SS2 FB
E1
24 VDC RY1 RY2
24 VDC
E1
KM1
KM2
M
Motor controller
(operation command)
RY1
RY2
15 10121314169 11
27
54318 6
Relay Output Module
(R Module)
Fuse
12 3424
3311 23
AC
K1
K2
KM1 KM2
Emitter Receiver
Shield
0 V (Blue)
Open
Auxiliary output 2 (Red)
Test input (Green)
Reset input (Yellow)
Interlock selection input
(White)
24 VDC (Brown)
Communication
line () (Pink)
Communication
line (+) (Gray)
24 VDC (Brown)
External device monitoring
input (Red)
Auxiliary output 1 (Yellow)
Control output 1 (Green)
Control output 2 (White)
0 V (Blue)
Shield
Model F39-JC@A-L
cable for emitter
Model F39-JC@A-D
cable for receiver
F3SJ (2nd unit)
Wiring when F3SJ's
testing function is used
Shield
Test SW
0 V (Blue)
Open (Red)
Test input (Green)
Reset input (Yellow)
Interlock selection input (White)
24 VDC (Brown)
(See note 2.)
(See note 2.)
(See note 2.)
Wiring for auto reset mode
S 2
Y 1 Y 2 Y 3
24 VDC
E 1
Wiring Connection with an F3SX-E-L2R Controller (Category 4)
An emergency stop switch, door switch, two-hand control, single beam or relay unit can be used in con-
junction with the F3SX. Various settings can be changed and input/output terminals can be monitored using
the setting support software for F3SX.
F3SJ-A settings
Auto reset mode
External device monitoring function
disabled
F3SX-E-L2R settings
Manual reset mode
Using feedback time monitoring function
S1: Emergency stop switch
(direct opening contacts)
(A165E, A22E)
S2: Reset switch
KM1, KM2: Magnetic contactor (LC1D)
RY1, RY2: Relay
M: 3-phase motor
E1: 24 VDC power supply (S82K)
Note: 1. This wiring example is for
category 4.
2. This example shows the
connection when auxiliary
output 1 is in the standard
setting (ON when light is
interrupted).
3. When the F3SJ-A is series-
connected, or 5 or more sets
are connected to the total
system of the F3SX, power
must be supplied to the
F3SJ-A from external source.
For details, see the F3SX
installation manual.
safety light curtains
D
For the Latest Information
On the Internet: www.sti.com or www.omron.ca
OMRON SCIENTIFIC TECHNOLOGIES, INC.
USA Tel. 1/888/510-4357 Canada Tel. 1/866/986-6766
D12
AGo to the Engineering Guide
For in-depth information on
safety standards and use.
F3SJ-A
n Wiring (continued)
Wiring Connection with a G9SX-AD322-T15 Controller (Category 4)
F3SJ-A settings
Auto reset mode
External device monitoring function
disabled
G9XS-AD322-T15 settings
Auto reset mode
Using feedback loop
S1: External test switch (connect to 0 V if the
switch is not necessary)
S2: Lockout reset switch (connect 24 V if the
switch is not necessary)
KM1 to KM4: Magnetic contactor
M1, M2: 3-phase motor
E1: 24 VDC power supply (S82K)
PLC: Programmable controller (used for
monitoring, not related to safety system)
A1
A2
S14 S24
KM1 KM2
S34 S44 S54
KM3 KM4
L1 X1 X2
T11
KM1
KM2
KM3
KM4
+24 V +24 V
T12 T21 T22 T31 T32 T33 Y1 T41 T42 M1 M2
PLC, etc.
Motor controller
Motor controller
(operation command)
Feedback loop
Open
G9SX-AD322-T15
Open Open Open OFF
AND
KM1
KM2
KM3
S3
KM4
Control circuit
Control output
KM1,KM2 N.C. contact
KM3,KM4 N.C. contact
KM1,KM2 N.O. contact
KM3,KM4 N.O. contact
Motor operation command
Motor rotation
OFF-delay time
+24 V (Brown)
0 V (Blue)
Control output 1 (Green)
Control output 2 (White)
Auxiliary output 1 (Yellow)
S1
S2
Emitter Receiver
Shield
0 V (Blue)
Open
Test input (Green)
Reset input (Yellow)
Interlock selection input (White)
+24 V (Brown)
Communication
line (+) (Gray)
Communication
line () (Pink)
External device monitoring
input (Red)
Shield
F39-JC@A-DF39-JC@A-L
+24 VDC
0 V
E1
Auxiliary output 2 (Red)
+24 V
T32 T33 Y1
KM3
KM4
T31
KM1
KM2
S3
Wiring for manual reset mode
Feedback loop
S3: Reset switch
safety light curtains
D
For the Latest Information
On the Internet: www.sti.com or www.omron.ca
OMRON SCIENTIFIC TECHNOLOGIES, INC.
USA Tel. 1/888/510-4357 Canada Tel. 1/866/986-6766
D13
F3SJ-A
n Specifications
Peformance
Resolution: 14 mm, 20 mm, 30 mm, 55 mm
Protected Height: 14 mm – 245 to 1631 mm (9.6 to 64.2 in.)
20 mm and 30 mm – 245 to 2495 mm (9.6 to 98.2 in.)
55 mm – 270 to 2470 mm (10.6 to 97.2 in.)
Operating Range: 0.2 to 9 m for: 14 mm (all protected heights)
20 mm resolution up to 1505 mm (59.3 in.) protected height
30 mm and 55 mm resolution up to 1620 mm (63.8 in.) protected height
0.2 to 7 m for: 20 mm resolution 1655 to 2495 mm (65.2 to 98.2 in.) protected height
30 mm resolution 1745 to 2495 mm (68.7 to 98.2 in.) protected height
55 mm resolution 1670 to 2470 mm (65.7 to 97.2 in.) protected height
Effective Aperture Angle: ±2.5° maximum, transmitter and receiver at operating range greater than 3 m (9.8 ft.)
Response Time: For 14 mm resolution systems up to 983 mm (38.7 in.) protected height 17.5 ms
For 14 mm resolution systems above 983 mm (38.7 in.) protected height 25 ms
For 20 mm resolution systems up to 1205 mm (47.4 in.) protected height 15 ms
For 20 mm resolution systems above 1205 mm (47.4 in.) protected height 22.5ms
For 30 mm resolution systems, all protected heights 17.5 ms
For 55 mm resolution systems, all protected heights 13 ms
Safety Output Rating: Two PNP outputs sourcing 300 mA max.
Auxiliary (Non-Safety) Output Ratings: One PNP output sourcing 300 mA max.
Light Source: Infrared LED, 870 nm
Light Source Life: NA
Indicators: Transmitter: 5 LED Light Level Indicators, 3 LED Error Indicators, Power, Interlock, EDM, Blanking/Test
Receiver: 5 LED Light Level Indicators, 3 LED Error Indicators, Machine Run, Machine Stop
Mechanical
Enclosure: Anodized aluminum housing
Cable Length: Optional cables are available up to 20 m(65.6 ft.) in length
Transmitter and Receiver Cable Connections: M12, 8-pin
Electrical
Power Supply: 24 VDC
Environmental
Protection Rating: IP65
Operating Temperature: -10 to 55°C (14 to 131°F)
Storage Temperature: -30 to 70°C (-22 to 158°F)
Relative Humidity: 35 to 85% non-condensing
Vibration: 10 to 55 Hz, double amplitude of 0.7 mm, 20 sweeps in X, Y, and Z directions
Shock: 100 m/s2, 1000 times each in X, Y and Z directions
Conformity/Approvals
Approvals: All F3SJ-A systems have been EC type examined to the requirements of IEC 61496-1, -2 for a Type 4 ESPE
Conforming to Standards: ANSI/RIA R15.06-1999; ANSI B11.19-2003; OSHA 1910.217(c); OSHA 1910.212.A
Specifications are subject to change without notice.
safety light curtains
D
For the Latest Information
On the Internet: www.sti.com or www.omron.ca
OMRON SCIENTIFIC TECHNOLOGIES, INC.
USA Tel. 1/888/510-4357 Canada Tel. 1/866/986-6766
D14
AGo to the Engineering Guide
For in-depth information on
safety standards and use.
F3SJ-A
n Specifications (continued)
Power Supply Voltage: 24 VDC ±10%
Power Consumption: DC1.7 W max (not including sensor’s current consumption)
Operation Time: 100 ms max. (not including the sensor’s response time)
Response Time: 10 ms max. (not including the sensor’s response time)
Relay Output
Number of Contacts: 3 N/O + 1 N/C
Rated Load: 25 VAC 5 A (cos = 1); 30 VDC 5 A L/R = 0 ms
Rated Current: 5 A
Connection Type
Between Sensors: M12 connector (8-pin)
Others: Terminal block
Weight: Approx. 280 g (9.9 oz.)
Specifications are subject to change without notice.
Control Unit
safety light curtains
D
For the Latest Information
On the Internet: www.sti.com or www.omron.ca
OMRON SCIENTIFIC TECHNOLOGIES, INC.
USA Tel. 1/888/510-4357 Canada Tel. 1/866/986-6766
D15
F3SJ-A
1
24
Intermediate mounting
bracket
300
43
6 dia.
15 dia. M12 Waterproof connector
9 dia.
13.75
2-Mounting holes
6.5 dia.
4-Mounting holes
37
10
Beam E
2-Mounting holes
C (Protective
height)
D53 42
5.5
7
22
31
30
16.5
2-Mounting holes
2-Top/bottom mounting brackets
5.5 20
20
30
3.75
6.25
(13.75)
B A
4-M5
22
2-M5
42
E
B
46
26
n Dimensions — mm
Protective Number of
Height Intermediate Brackets E*
245 to 596 mm (9.6 to 23.5 in.) 0
600 to 1130 mm (23.6 to 44.5 in.) 1 E = B/2
1136 to 1658 mm (44.7 to 65.3 in.) 2 E = B/3
1660 to 2180 mm (65.4 to 85.8 in.) 3 E = B/4
2195 to 2500 mm (86.4 to 98.4 in.) 4 E = B/5
*Use E = 530 or less when none of the E values shown above are used.
C (protective height) = 4-digit number in the table
A = C + 74
B = C + 46.5
D = C - 20
E = see chart below
Mounting Screw Holes
safety light curtains
D
For the Latest Information
On the Internet: www.sti.com or www.omron.ca
OMRON SCIENTIFIC TECHNOLOGIES, INC.
USA Tel. 1/888/510-4357 Canada Tel. 1/866/986-6766
D16
AGo to the Engineering Guide
For in-depth information on
safety standards and use.
F3SJ-A
n Ordering
The minimum components required for an F3SJ-A system are a emitter receiver set and a set of single or
double-ended connector cables. See the table below for an overview of the versions available. The pages
which follow provide specific part numbers and accessory descriptions.
Safety Light Curtain F3SJ-A
Designator Protection Detection Beam Gap Operating Range No. of Beams Protective Height
F3SJ-A££££P141 Finger 14 mm 9 mm 0.2 to 9 m (0.7 to 29.5 ft.) 26 to 180 245 to 1631 mm (9.6 to 64.2 in.)
F3SJ-A££££P201 Hand 20 mm 15 mm 0.2 to 9 m (0.7 to 29.5 ft.) 16 to 100 245 to 1505 mm (9.6 to 59.3 in.)
F3SJ-A££££P201 Hand 20 mm 15 mm 0.2 to 7 m (0.7 to 23.0 ft.) 110 to 166 1655 to 2495 mm (65.2 to 98.2 in.)
F3SJ-A££££P20-TS2 Hand 20 mm 15 mm 0.2 to 9 m (0.7 to 29.5 ft.) 16 to 100 245 to 1505 mm (9.6 to 59.3 in.)
F3SJ-A££££P20-TS2 Hand 20 mm 15 mm 0.2 to 7 m (0.7 to 23.0 ft.) 110 to 166 1655 to 2495 mm (65.2 to 98.2 in.)
F3SJ-A££££P301 Hand/arm 30 mm 25 mm 0.2 to 9 m (0.7 to 29.5 ft.) 10 to 65 245 to 1620 mm (9.6 to 63.8 in.)
F3SJ-A££££P301 Hand/arm 30 mm 25 mm 0.2 to 7 m (0.7 to 23.0 ft.) 70 to 100 1745 to 2495 mm (68.7 to 98.2 in.)
F3SJ-A££££P551 Leg/body 50 mm 50 mm 0.2 to 9 m (0.7 to 29.5 ft.) 6 to 33 270 to 1620 mm (10.6 to 63.8 in.)
F3SJ-A££££P551 Leg/body 50 mm 50 mm 0. 2 to 7 m (0.7 to 23.0 ft.) 34 to 50 1670 to 2470 mm (65.7 to 97.2 in.)
Notes:
Connection cables are not included with the products and must be purchased separately as needed.
1 Models with S-mark certification have an “-S” at the end of the model number. S-mark certification is for equipment sold in South Korea. Example: F3SJ-A0245P14-S.
2 Models with fixed auto reset (-TS). Parameters cannot be set using the F39-MC21 Setting Console or F39-GWUM “SD Manager” Support Software for F3SJ-A.
Specific Model Numbers
F3SJ-A14 Series
F3SJ-A0245P14 26 245
F3SJ-A0263P14 28 263
F3SJ-A0281P14 30 281
F3SJ-A0299P14 32 299
F3SJ-A0317P14 34 317
F3SJ-A0335P14 36 335
F3SJ-A0353P14 38 353
F3SJ-A0371P14 40 371
F3SJ-A0389P14 42 389
F3SJ-A0407P14 44 407
F3SJ-A0425P14 46 425
F3SJ-A0443P14 48 443
F3SJ-A0461P14 50 461
F3SJ-A0479P14 52 479
F3SJ-A0497P14 54 497
F3SJ-A0515P14 56 515
F3SJ-A0533P14 58 533
F3SJ-A0551P14 60 551
F3SJ-A0569P14 62 569
F3SJ-A0587P14 64 587
F3SJ-A0605P14 66 605
F3SJ-A0623P14 68 623
F3SJ-A0659P14 72 659
F3SJ-A0695P14 76 695
F3SJ-A0731P14 80 731
F3SJ-A0767P14 84 767
F3SJ-A0803P14 88 803
F3SJ-A0839P14 92 839
F3SJ-A0875P14 96 875
F3SJ-A0911P14 100 911
F3SJ-A0983P14 108 983
F3SJ-A1055P14 116 1055
F3SJ-A1127P14 124 1127
F3SJ-A1199P14 132 1199
F3SJ-A1271P14 140 1271
F3SJ-A1343P14 148 1343
F3SJ-A1415P14 156 1415
F3SJ-A1487P14 164 1487
F3SJ-A1559P14 172 1559
F3SJ-A1631P14 180 1631
F3SJ-A20, F3SJ-A20-TS* Series
F3SJ-A0245P20 16 245
F3SJ-A0275P20 18 275
F3SJ-A0305P20 20 305
F3SJ-A0335P20 22 355
F3SJ-A0365P20 24 365
F3SJ-A0395P20 26 395
F3SJ-A0425P20 28 425
F3SJ-A0455P20 30 455
F3SJ-A0485P20 32 485
F3SJ-A0515P20 34 515
F3SJ-A0545P20 36 545
F3SJ-A0575P20 39 575
F3SJ-A0605P20 40 605
F3SJ-A0635P20 42 635
F3SJ-A0665P20 44 665
F3SJ-A0695P20 46 695
F3SJ-A0725P20 48 725
F3SJ-A0755P20 50 755
F3SJ-A0785P20 52 785
F3SJ-A0815P20 54 815
F3SJ-A0845P20 56 845
F3SJ-A0875P20 58 875
F3SJ-A0905P20 60 905
F3SJ-A0935P20 62 935
F3SJ-A0965P20 64 965
F3SJ-A0995P20 66 995
F3SJ-A1025P20 68 1025
F3SJ-A1055P20 70 1055
F3SJ-A1085P20 72 1085
F3SJ-A1115P20 74 1115
F3SJ-A1145P20 76 1145
F3SJ-A1175P20 78 1175
F3SJ-A1205P20 80 1205
F3SJ-A1235P20 82 1235
F3SJ-A1265P20 84 1265
F3SJ-A1325P20 88 1325
F3SJ-A1385P20 92 1385
F3SJ-A1445P20 96 1445
F3SJ-A1505P20 100 1505
F3SJ-A1655P20 110 1655
F3SJ-A1805P20 120 1805
F3SJ-A1955P20 130 1955
F3SJ-A2105P20 140 2105
F3SJ-A2255P20 150 2255
F3SJ-A2405P20 160 2405
F3SJ-A2495P20 166 2495
F3SJ-A30 Series
F3SJ-A0245P30 10 245
F3SJ-A0270P30 11 270
F3SJ-A0295P30 12 295
F3SJ-A0320P30 13 320
F3SJ-A0345P30 14 345
F3SJ-A0370P30 15 370
F3SJ-A0395P30 16 395
F3SJ-A0420P30 17 420
F3SJ-A0445P30 18 445
F3SJ-A0470P30 19 470
F3SJ-A0495P30 20 495
F3SJ-A0520P30 21 520
F3SJ-A0545P30 22 545
F3SJ-A0570P30 23 570
F3SJ-A0595P30 24 595
F3SJ-A0620P30 25 620
F3SJ-A0645P30 26 645
F3SJ-A0670P30 27 670
F3SJ-A0695P30 28 695
F3SJ-A0720P30 29 720
No. of Protective
Model Beams Height (mm)
safety light curtains
D
For the Latest Information
On the Internet: www.sti.com or www.omron.ca
OMRON SCIENTIFIC TECHNOLOGIES, INC.
USA Tel. 1/888/510-4357 Canada Tel. 1/866/986-6766
D17
F3SJ-A
F3SJ-A0745P30 30 745
F3SJ-A0770P30 31 770
F3SJ-A0795P30 32 795
F3SJ-A0820P30 33 820
F3SJ-A0845P30 34 845
F3SJ-A0870P30 35 870
F3SJ-A0895P30 36 895
F3SJ-A0920P30 37 920
F3SJ-A0945P30 38 945
F3SJ-A0970P30 39 970
F3SJ-A0995P30 40 995
F3SJ-A1020P30 41 1020
F3SJ-A1045P30 42 1045
F3SJ-A1070P30 43 1070
F3SJ-A1095P30 44 1095
F3SJ-A1120P30 45 1120
F3SJ-A1145P30 46 1145
F3SJ-A1170P30 47 1170
F3SJ-A1195P30 48 1195
F3SJ-A1220P30 49 1220
F3SJ-A1245P30 50 1245
F3SJ-A1270P30 51 1270
F3SJ-A1295P30 52 1295
F3SJ-A1395P30 56 1395
F3SJ-A1495P30 60 1495
F3SJ-A1620P30 65 1620
F3SJ-A1745P30 70 1745
F3SJ-A1870P30 75 1870
F3SJ-A1995P30 80 1995
F3SJ-A2120P30 85 2120
F3SJ-A2245P30 90 2245
F3SJ-A2370P30 95 2370
F3SJ-A2495P30 200 2495
F3SJ-A55 Series
F3SJ-A0270P55 6 270
F3SJ-A0320P55 7 320
F3SJ-A0370P55 8 370
F3SJ-A0420P55 9 420
F3SJ-A0470P55 10 470
F3SJ-A0520P55 11 520
F3SJ-A0570P55 12 570
F3SJ-A0620P55 13 620
F3SJ-A0670P55 14 670
F3SJ-A0720P55 15 720
F3SJ-A0770P55 16 770
F3SJ-A0820P55 17 820
F3SJ-A0870P55 18 870
F3SJ-A0920P55 19 920
F3SJ-A0970P55 20 970
F3SJ-A1020P55 21 1020
F3SJ-A1070P55 22 1070
F3SJ-A1120P55 23 1120
F3SJ-A1170P55 24 1170
F3SJ-A1220P55 25 1220
F3SJ-A1270P55 26 1270
F3SJ-A1320P55 27 1320
F3SJ-A1370P55 28 1370
F3SJ-A1420P55 29 1420
F3SJ-A1470P55 30 1470
F3SJ-A1520P55 31 1520
F3SJ-A1570P55 32 1570
F3SJ-A1620P55 33 1620
F3SJ-A1670P55 34 1670
F3SJ-A1720P55 35 1720
F3SJ-A1770P55 36 1770
F3SJ-A1820P55 37 1820
F3SJ-A1870P55 38 1870
F3SJ-A1920P55 39 1920
F3SJ-A1970P55 40 1970
F3SJ-A2020P55 41 2020
F3SJ-A2070P55 42 2070
F3SJ-A2120P55 43 2120
F3SJ-A2170P55 44 2170
F3SJ-A2220P55 45 2220
F3SJ-A2270P55 46 2270
F3SJ-A2320P55 47 2320
F3SJ-A2370P55 48 2370
F3SJ-A2420P55 49 2420
F3SJ-A2470P55 50 2470
*The suffix “-TS” is attached to the model
number of models with fixed auto reset.
Accessories
Model Description
Single-End Connector Cable (2 cables per set, for emitter and receiver)
For wiring with safety circuit such as single safety relay, safety relay unit, and safety controller
F39-JC3A M12 connector (8-pin), 3 m (9.8 ft.)
F39-JC7A M12 connector (8-pin), 7 m (23.0 ft.)
F39-JC10A M12 connector (8-pin), 10 m (32.8 ft.)
F39-JC15A M12 connector (8-pin), 15 m (49.2 ft.)
F39-JC20A M12 connector (8-pin), 20 m (65.6 ft.)
Double-End Connector Cable (2 cables per set, for emitter and receiver)
For connection with F3SP-B1P control unit, and for extension when series-connected. Note: To extend the cable length under series
connection, use F39-JJR3W and F39-JC£B in combination.
F39-JCR5B M12 connector (8-pin), 0.5 m (1.6 ft.)
F39-JC1B M12 connector (8-pin), 1 m (3.3 ft.)
F39-JC3B M12 connector (8-pin), 3 m (9.8 ft.)
F39-JC5B M12 connector (8-pin), 5 m (16.4 ft.)
F39-JC7B M12 connector (8-pin), 7 m (23.0 ft.)
F39-JC10B M12 connector (8-pin), 10 m (32.8 ft.)
F39-JC15B M12 connector (8-pin), 15 m (49.2 ft.)
F39-JC20B M12 connector (8-pin), 20 m (65.6 ft.)
Series Connection Cable (2 cables per set, for emitter and receiver)
F39-JJR3W Series connection cable3 or when using water-resistant case4, 0.3 m (1.0 ft.)
F39-JC£B Extension cable, 0.5 to 15 m (1.6 to 49.2 ft.)
To change series connection length in combination with F39-JJR3W
F39-JJR06L Side-by-side series connection cable, 0.06 m (2.4 in.)
Dedicated series connection cable with minimum length, used in place of the sensor’s cable with connector
F39-JJR15L Side-by-side series connection cable, 0.15 m (5.9 in.)
Dedicated series connection cable with minimum length, used in place of the sensor’s cable with connector
3 Total cable length of series connection is 0.6 m to connect to connector cable of the main sensor unit. For series connection with
minimum length, use the F39-JJR06L or F39-JJR15L.
4 When using the F39-EJ££££-L/D water-resistant case in series connection configurations, use the special series connection
cables for the water-resistant case.
F39-JC7A
F39-JC15B
F39-JC£B
F39-JJR06L
F39-JJR15L
F39-JJR3W
safety light curtains
D
For the Latest Information
On the Internet: www.sti.com or www.omron.ca
OMRON SCIENTIFIC TECHNOLOGIES, INC.
USA Tel. 1/888/510-4357 Canada Tel. 1/866/986-6766
D18
AGo to the Engineering Guide
For in-depth information on
safety standards and use.
F3SJ-A
n Ordering (continued)
Model Description
Safety Controller
F3SX-EL2 Can connect 2 sets of F3SJ-As and emergency stop switch
DC semiconductor safety output
F3SX-E-L2L2 Can connect 4 sets of F3SJ-As and emergency stop switch
DC semiconductor safety output
F3SX-N-L2R Can connect 2 sets of F3SJ-As and emergency stop switch
Relay output (2 N/O + 2 N/C)
F3SX-N-L2L2R Can connect 4 sets of F3SJ-As and emergency stop switch
Relay output (2 N/O + 2 N/C)
Connection Cable for F3SX (F3SX to F39-CN5)
F39-JC1T F3SX connection cable, 1 m (3.3 ft.)
F39-JC3T F3SX connection cable, 3 m (9.8 ft.)
F39-JC5T F3SX connection cable, 5 m (16.4 ft.)
F39-JC7T F3SX connection cable, 7 m (23.0 ft.)
F39-JC10T F3SX connection cable, 10 m (32.8 ft.)
F39-JC15T F3SX connection cable, 15 m (49.2 ft.)
Branch Connector for F3SX (F39-JC£T to F39-JC£B)
F39-CN5 Branch connector for F3SX
Accessories (continued)
F3SX
F39-JC-10T
F39-CN5
Accessory connection example
F3SJ
Emitter
Branch connector for
safety light curtains
F39-CN5
Double-end connector cable:
F39-JC@B-L (gray)
Wire color:
Gray
Wire color:
Black
Double-end connector cabl
e
F39-JC@B-D (black)
Connection cable for F3SX
F39-JC@T
F3SX
F3SJ
Receiver
Gray Black
safety light curtains
D
For the Latest Information
On the Internet: www.sti.com or www.omron.ca
OMRON SCIENTIFIC TECHNOLOGIES, INC.
USA Tel. 1/888/510-4357 Canada Tel. 1/866/986-6766
D19
F3SJ-A
Model Description
Control Unit
F3SP-B1P Relay, 3 N/O + 1 N/C output, for connection with F3SJ-A, use an F39-JC£B double-end
connector cable
Force-Guided Relays
G7SA-2A2B 4 contacts, 2 N/O + 2 N/C, Rated switch load: 250 VAC 6 A, 30 VDC 6 A
G7SA-3A1B 4 contacts, 3 N/O + 1 N/C, Rated switch load: 250 VAC 6 A, 30 VDC 6 A
G7S-4A2B-E 6 contacts, 4 N/O + 2 N/C, Rated switch load: 250 VAC 10 A, 30 VDC 10 A
G7S-3A3B-E 6 contacts, 3 N/O + 3 N/O, Rated switch load: 250 VAC 10 A, 30 VDC 10 A
Dedicated External Indicator Set (Can be connected to either an emitter or a receiver)
F39-A01PR-PAC Indicator (red), mounting bracket (1 set), and dedicated connection cable (0.1 m)
F39-A01PG-PAC Indicator (green), mounting bracket (1 set), and dedicated connection cable (0.1 m)
F39-A01PY-PAC Indicator (yellow), mounting bracket (1 set), and dedicated connection cable (0.1 m)
General External Indicator Cable
F39-JJ3N Cable to connect top of the main unit and an off-the-shelf external indicator (2-wire), 3 m (9.8 ft.)
Splatter Protection Cover
F39-HJ££££ For F3SJ-A series sensor, reduces operating range by 10%, includes two pieces for emitter and
receiver
Sensor Mounting Brackets (sold separately)
F39-LJ1 Standard mounting bracket (for top/bottom), included with main unit, 2 for emitter and 2 for
receiver (total of 4 per set)
F39-LJ2 Flat side mounting bracket, Use these small-sized brackets when performing side mounting
with standard mounting brackets so that they do not protrude from the detection surface, 2 for
emitter and 2 for receiver (total of 4 per set)
F39-LJ3 Free-location mounting bracket (also used as standard intermediate bracket), Use these brackets
for mounting any place without using standard bracket, 1 set with 2 pieces
Key Cap for Muting
F39-CN6 Cap attaches to the main unit to enable muting function, attach to either an emitter or a receiver,
orange case
Setting Tools5
F39-GWUM “SD Manager” Setting Support Software for the F3SJ-A
Accessories: SD Manager CD-ROM, F39-CN1 Branch Connector, Connector Cap, 2 m Dedicated
Cable, 0.3 m Dedicated Cable with Plug, Instruction Manual
F39-MC21 Setting Console
Accessories: F39-CN1 Branch Connector, Connector Cap, 2 m Dedicated Cable, 0.3 m Dedicated
Cable with Plug, Instruction Manual
Water-Reistant Case (Set of 1 tube, packing, and dedicated connector cable)
When using for both emitter and receiver, order two sets.
F39-EJ££££-L Water-resistant case for emitter, includes gray cable for emitter
F39-EJ££££-D Water-resistant case for receiver, includes black cable for receiver
F39-EJ-R6 Rear mounting brackets, top/bottom 1 each, total of 2
F39-EJ-S6 Side mounting brackets, top/bottom 1 each, total of 2
F39-JJR3WE-L Series connection cable for emitter, purchase additionally for series connection when using the
water-resistant case
F39-JJR3WE-D Series connection cable for receiver, purchase additionally for series connection when using the
water-resistant case
5 The setting tools described above can be connected only to F3SJ-A models with built-in software of Ver. 2 or later.
Note that the setting tools cannot be used with products shipped prior to December 2005. The setting tools cannot
be used for setting parameters on the F3SJ-A£-TS series, but the monitoring function can be used.
6 Be sure to purchase brackets with the case to match the mounting direction (rear or side).
Accessories (continued)
F3SP-B1P
F39-A01-PR-PAC
F39-HJ££££
F39-JJ3N
F39-CN6
F39-GWUM
F39-MC21
F39-LJ1 F39-LJ2
F39-LJ3
F39-EJ££££-L/D
F39-EJ-R
F39-EJ-S
G7SA
G7S