ESC/ESP-120 ESC/ESP-240
13.5V 27V 54V 13.5V 27V 54V
8A 4A 2A 16A 8A 4A
0~8A 0~4A 0~2A 0~16A 0~8A 0~4A
108W 108W 108W 216W 216W 216W
120mVp-p 150mVp-p 400mVp-p 120mVp-p 150mVp-p 400mVp-p
12~15V 24~30V 48~56V 12~15V 24~30V 48~56V
2.0%
2.0%
1.0% 1.0% 2.0% 1.0% 1.0%
1.0% 2.0%
1.0%
1.0%
0.5% 0.5% 0.5%
0.5%
0.5% 0.5%
0.5%
SPECIFICATION
MODEL
DCVOLTAGE
RATEDCURRENT
CURRENTRANGE
RATEDPOWER
OUTPUT VOLTAGE ADJ.RANGE
LINEREGULATION
LOADREGULATION
SETUP,RISETIME
HOLDTIME (Typ.)
VOLTAGERANGE
FREQUENCY RANGE
EFFICIENCY (Typ.)
INPUT
INRUSHCURRENT (Typ.)
LEAKAGECURRENT
SAFETY STANDARDS
HARMONICCURRENT
EMSIMMUNITY
WORKINGTEMP.
WORKINGHUMIDITY
FANCONTROL
STORAGETEMP.,HUMIDITY
VIBRATION
MTBF
DIMENSIONOTHERS
NOTE
PACKING
OVERLOAD
OVERVOLTAGE
BATTERY
FUNCTION
ACCURRENT (Typ.)
200ms,100msatfullload
36msatfullload
200ms,100msatfullload
30msatfullload
88~132VAC/176~264VACselectedbyswitch249~370VDC
47~63Hz
81% 83% 84% 81% 84% 85%
3A/115VAC1.5A/230VAC 4.5A/115VAC2.5A/230VAC
COLDSTART 40A
<3.5mA /240VAC
105~135% ratedoutputpower
15.5~18.2V 15.5~18.2V31~36.5V 31~36.5V62.1~72.9V 62.1~72.9V
ESCserieswithbat.polarity,bat.Undervoltage,bat.Overvoltageprotection
Protectiontype:Foldbackcurrentlimiting,recoversautomaticallyafterfaultconditionisremoved
Protectiontype:Constantvoltagelimiting,recoversautomaticallyafterfaultconditionisremoved
CSA60950-1(UL3101-1,IEC1010-1,EN61010-1) Approved
CompliancetoEN55022(CISPR22)ClassB
Complianceto EN61000-3-2,-3
Complianceto EN61000-4-2,3,4;ENV50204,Lightindustrylevel,criteria A
-10~+60 (Refertooutputloadderatingcurve)
20~90%RHnon-condensing
NOFAN RTH5 60 FANON, 50 FANOFF
-20~+85 ,10~95%RH
10~500Hz,2G10min./1cycle,60min.eachalongX, Y,Zaxes
215.8Khrsmin.(ESC-120)200.6Khrsmin.(ESC-240)250.9KHrsmin.(ESP-120)226.6KHrsmin.(ESP-240)MIL-HDBK-217F(25 )
150*140*86mm(L*W*H)
1.38Kg;8pcs/12Kg/1.1CUFT(ESC-120) 1.5Kg;8pcs/13Kg/1.1CUFT(ESC-240)
1. All parameters NOT specially mentioned are measured at 230VAC input, rated load and 25 of ambient temperature.
2. Ripple & noise are measured at 20MHz of bandwidth by using a 12" twisted pair-wire terminated with a 0.1uf & 47uf parallel capacitor.
3. Tolerance : includes set up tolerance, line regulation and load regulation.
4. The power supply is considered a component which will be installed into a final equipment. The final equipment must be re-confirmed that it still meets
EMC directives.
FileName:ESC/ESP-120/240-SPEC2005-09-13
OVERTEMPERATURE Protectiontype:Shundowno/pvoltage,recoversautomaticallyaftertemperaturegoesdown
108W/216WDesktopPowerSupplyorCharger
AC input range selected by switch
Protections:Short circuit/Over load/Over voltage/Over temperature
Battery under/Over voltage and polarity protections(ESC only)
Forced air cooling by built-in DC fan(240V only)
Fixed switching frequency at 25KHz
3 color LED loading indicator
2 years warranty
Features :
ESC/ESP-120/240 serie s
RIPPLE&NOISE(max.) Note.2
VOLTAGETOLERANCE Note.3
ENVIRONMENT
PROTECTION
EMICONDUCTION&RADIATION
SAFETY &
EMC
(Note4)
WITHSTANDVOLTAGE
ISOLATIONRESISTANCE
I/P-O/P:3KVACI/P-FG:1.5KVACO/P-FG:0.5KVAC
I/P-O/P,I/P-FG,O/P-FG:100MOhms/500VDC
RTH5 80 DetectonheatsinkofQ1,Q2powertransistor RTH5 85 DetectonheatsinkofQ1,Q2powertransistor