Inductive sensors IWRM 12Z (Teach-in) Inductive linear sensors sample drawing 60 SW 17 45 M12 x 1 M12 x 1 general data sample picture mounting type quasi shielded special type 2 adjust. switching points measuring distance Sd 0 ... 4 mm resolution repeat accuracy < 0,005 mm (stat.) < 0,005 mm (dynam.) < 0,01 mm linearity error 16 m temperature drift 5 % (Full Scale) electrical data response time (factory characteristic) < 2,5 ms response time (teach in characteristic) < 3,1 ms output circuit voltage output / PNP output signal 0 ... 10 VDC load resistance > 1000 Ohm short circuit protection yes reverse polarity protection yes mechanical data type cylindrical threaded housing material brass nickel plated dimension 12 mm housing length 60 mm connection types connector M12 ambient conditions operating temperature -10 ... +70 C protection class IP 67 order reference adjustment voltage supply range +Vs output current voltage drop Vd current consumption max. baud rate IWRM 12Z8704/S14C external Teach-in 15 ... 30 VDC < 10 mA (PNP) < 5 VDC (PNP) 20 mA - IWRM 12Z8704/S14C/IO external Teach-in and IO-Link 18 ... 30 VDC < 200 mA (PNP) < 2 VDC (PNP) 24 mA 38400 1 www.baumer.com 14/10/2011