Preventa™ XUSLP Light Curtains
Technical Data
© 2006 Schneider Electric All Rights Reserved
4
07/2006
Preventa XUSLP Light Cur tains: Technical Data
(1) Pre-wired female connectors to be ordered separately, see page 7.
Light curtain type XUSLPpppp
Conformity approvals
Conformity to standards ANSI/RIA R15.06, ANSI B11:19-1990, OSHA 1910.217(C), OSHA 1910.212, IEC 61496-1-2 for type 4
ESPE
Certifications e, TUV, UL, CSA
European directives Machinery directive 98/37/EC, Work equipment directive 89/655/EEC and EMC directive 89/336 EEC
Environment
Ambient air temperature Operating + 32 to + 131 °F (0 to + 55 °C)
For storage -13 to +167 °F (- 25 to+ 75 °C)
Relative humidity 95% maximum, without condensation
Degree of protection IP 65
Shock and vibration resistance Conforming to IEC 61496-1 Shock resistance: 10 gn, impulse 16 ms,
Vibration resistance: 10…55 Hz, amplitude: 0.014 ± 0.0020 in. (0.35 ± 0.05 mm)
Materials Casing: aluminium with electrostatically applied red (RAL 3000) polyester paint finish; end caps: 20%
fiberglass impregnated polycarbonate. Front face: acrylic.
Mounting End brackets (included)
Optical characteristics
Minimum object sensitivity (MOS) 11.8, 15.8, 19.7, and 23.6 in. (300, 400, 500, and 600 m) and single beam (Body protection)
Nominal sensing range (Sn) 2.6 - 65.6 ft (0.8 - 20 m) or 2.6 - 230 ft (0.8 - 70 m) depending on configuration and 2.6 - 25.6 ft
(0.8 - 8 m) for light curtains with passive receiver.
Protected height Depending on number of light beams
Effective aperture angle (EAA) 2.5° at 9.8 ft (3 m)
Light source GaAIAs LED, 850 nm
Resistance to ambient light Conforming to IEC/EN 61496-2
Electrical characteristics
Response time ms < 16 to < 24 depending on light beam coding selected
Power supply
c24 Vdc ± 20% 2 A conforming to IEC 61496 and IEC 60204-1
Transmitter mA 100
Receiver A 1.6 (with maximum load)
Maximum current consumption
(no-load)
Transmitter mA 100
Receiver mA 300
Resistance to interference Conforming to EN 61496-1
Safety outputs OSSD (Output Signal Switching Devices) 2 solid-state PNP (N.O.) outputs ≤ 650 mA, c 24 Vdc (Short-circuit protected)
Auxiliary output 1 solid-state output 100 mA, c 24 Vdc, PNP
Monitoring activation of output switching devices (MPCE/EDM) 50 mA, c 24 Vdc
Signalling Transmitter 1 LED (power supply)
Receiver 3 LEDs (stop, run, interlock) and a 2-digit display for diagnostics
Connections (1) Transmitter M12, 5-pin, male connector or terminal block
Receiver M12, 8-pin, male connector or terminal block
Cable guage Transmitter/receiver pre-wired
connector 22 awg (0.32 mm2)
Cable resistance Transmitter/receiver 0.016 Ω per foot (0.055 Ω per meter) for 22 awg (0.32 mm2) c.s.a. cable
Cable lengths Pre-wired connectors with cable lengths of 16.4, 32.8, 49.2 and 98.4 ft (5, 10, 15 and 30 m) are available
separately. The maximum cable length is 394 ft (120 m), depending on the load current and power supply.
Functions
Functions
Start:
Auto/Manual, manual 1st cycle,
Monitoring of external switching devices (EDM: External Devices Monitoring),
Test (MTS: Monitoring Test Signal) for XUS LPZ only,
Alignment aid by display of each light beam broken,
Display of operating modes and alarm by LEDs and 2-digit display.
Selection of Auto/Manual, relay monitoring, alarm or auxiliary output functions, light beam coding and
selection of sensing distance using configuration switches.
Monitoring of external switching devices
(EDM = External Devices Monitoring)
Monitoring of the function (open or closed) as well as the response time of the power components.
Configurable using configuration switches.
“Test” function (MTS) Instigates the stop instruction of the light curtain by opening the contact (simulated intrusion)
“Muting” function Possible with external module XPSLMS1150.
Ordering Information . . . . . . .5 - 7
Dimensions. . . . . . . . . . . . . . 8 - 9
Wiring Diagrams . . . . . . . .10 - 11