KMF Power Entry Modules with Line Filter https://www.schurter.com /PG06 IEC Appliance Inlet with Filter, Fuseholder 1- or 2-pole, Line Switch 2-pole Order required accessories separately Protection class II without shield Protection class I with shield C14 C18 70 C 70 C Approvals and Compliances Description - Panel Mount : Snap-in version from front side - 4 Functions : Appliance Inlet protection class I or II , Line Switch 2-pole , Fuseholder for fuse-links 5 x 20 mm 1 or 2pole , Line filter in standard and medical version - Quick connect terminals 4.8 x 0.8 mm Unique Selling Proposition - Most compact solution on the market Innovative EMC-shielding Easy and flexible snap-in mounting Protection class I or II versions Characteristics - Ultra-compact design. Small dimensions in front of and behind the panel - All single elements are already wired - For added safety "Extra-Safe" fuse drawers are available - Innovative EMC-shielding with flexible steel segments for an excellent contact - Suitable for use in equipment according to IEC/UL 60950 Suitable for use in medical equipment according to IEC/UL 60601-1 Other versions on request - Fuse drawer 1-pole, plus spare fuse case - Fuse drawer 2-pole, with shorting bar - Other rocker marking References Alternative: version without line filter KM Alternative: version for screw mounting DD12;DD14 Weblinks pdf datasheet, html-datasheet, General Product Information, DistributorStock-Check, Accessories, Detailed request for product Technical Data Ratings IEC Ratings UL/CSA Leakage Current Dielectric Strength Allowable Operation Temperature Climatic Category IP-Protection Protection Class Terminal Panel Thickness S Material: Housing 1 - 10 A @ Ta 40 C / 250 VAC; 50 Hz 1 - 10 A @ Ta 40 C / 125/250 VAC; 60 Hz standard < 0.5 mA (250 V / 60 Hz) medical < 5 A (250 V / 60 Hz) > 1.7 kVDC between L-N > 2.7 kVDC between L/N-PE Test voltage (2 sec) -25 C to 85 C 25/085/21 acc. to IEC 60068-1 from front side IP 40 acc. to IEC 60529 Suitable for appliances with protection class I or II acc. to IEC 61140 Quick connect terminals 4.8 x 0.8 mm Snap-in: 1/1.5/2/2.5 mm (all steps with one variant) Thermoplastic, black, UL 94V-0 appliance inlet/-outlet Fuseholder Rated Power Acceptance @ Ta 23 C Power Acceptance @ Ta > 23C Line Switch Line Filter MTBF C14 C18 acc. to IEC 60320-1, UL 498, CSA C22.2 no. 42 (for cold conditions) pin-temperature 70 C, 10 A, Protection Class I or II 1 or 2 pole, Shocksafe category PC2 acc. to IEC 60127-6, for fuse-links 5 x 20 mm 5 x 20: 2 W (1 pole)/ 1.4 W (2-pole) per pole Admissible power acceptance at higher ambient temperature see derating curves 2-pole, non-illuminated, acc. to IEC 61058-1 Technical Details Standard and Medical Version, IEC 60939, UL 1283, CSA C22.2 no. 8 Technical Details > 1'800'000 h acc. to MIL-HB-217 F Approvals and Compliances Detailed information on product approvals, code requirements, usage instructions and detailed test conditions can be looked up in Details about Approvals EMC Products 1 KMF Power Entry Modules with Line Filter https://www.schurter.com /PG06 Approvals The approval mark is used by the testing authorities to certify compliance with the safety requirements placed on electronic products. Approval Reference Type: KMF Approval Logo Certificates Certification Body Description VDE Approvals VDE Certificate Number: 40035743 UL Approvals UL UL File Number: E72928 CQC Approvals CQC CCC File Number: 2009010204326571 Design Standard Description Designed according to IEC 60320-1 Appliance couplers for household and similar general purposes Designed according to IEC 60939 Passive filters for suppressing electromagnetic interference Designed according to IEC 60127-6 Miniature fuses. Part 6. Fuse-holders for miniature fuse-links Designed according to IEC 61058-1 Switches for appliances. Part 1. General requirements Designed according to UL 498 Standard for Attachment Plugs and Receptacles Designed according to UL 1283 Electromagnetic interference filters Designed according to CSA C22.2 no. 42 General Use Receptacles, Attachment Plugs, and Similar Wiring Devices Designed according to CSA C22.2 no. 8 Electromagnetic interference (EMI) filters Design Standard Description Designed for applications acc. IEC/UL 60950 IEC 60950-1 includes the basic requirements for the safety of information technologyequipment. Designed for applications acc. IEC 60601-1 Medical electrical equipment - Part 1: General requirements for basic safety and essential performance Designed for applications acc. IEC 60335-1 Safety of electrical appliances for household and similar purposes. Meets the requirements for appliances in unattended use. This includes the enhanced requirements of glow wire tests acc. to IEC 60695-2-12 and -13. Details Initiator Description CE declaration of conformity SCHURTER AG The CE marking declares that the product complies with the applicable requirements laid down in the harmonisation of Community legislation on its affixing in accordance with EU Regulation 765/2008. RoHS SCHURTER AG EU Directive RoHS 2011/65/EU China RoHS SCHURTER AG The law SJ / T 11363-2006 (China RoHS) has been in force since 1 March 2007. It is similar to the EU directive RoHS. REACH SCHURTER AG On 1 June 2007, Regulation (EC) No 1907/2006 on the Registration, Evaluation, Authorization and Restriction of Chemicals 1 (abbreviated as "REACH") entered into force. Medical Equipment SCHURTER AG Suitable for use in medical equipment according to IEC/UL 60601-1 Product standards Product standards that are referenced Organization Application standards Application standards where the product can be used Organization Compliances The product complies with following Guide Lines Identification 2 EMC Products KMF Power Entry Modules with Line Filter https://www.schurter.com /PG06 Dimension [mm] 30.4 .5 R1 25.7 0. 3 +0.10 30.5 m 10.7 ax .R 32 50 47.5 N 47.8 -0.05 L 0 S 0.05 40.4 28.5 2.5 +0.10 28.8 -0.05 Technical Data of Filter-Components Rated Current [A] Filter-Type Inductances L [mH] Capacitance CX [nF] Capacitance CY [nF] R [M] 1 Standard Version 2 x 11 47 2.2 - 2 Standard Version 2x4 47 2.2 - 4 Standard Version 2 x 1.6 47 2.2 - 6 Standard Version 2 x 0.7 47 2.2 - 10 Standard Version 2 x 0.4 47 2.2 - 1 Medical Version (M5) 2 x 11 47 - 1 2 Medical Version (M5) 2x4 47 - 1 4 Medical Version (M5) 2 x 1.6 47 - 1 6 Medical Version (M5) 2 x 0.7 47 - 1 10 Medical Version (M5) 2 x 0.4 47 - 1 EMC Products 3 KMF Power Entry Modules with Line Filter https://www.schurter.com /PG06 Diagrams Standard version Medical version (M5) L L L' F1 L1 1) 2) Cy PE Cx L2 F2 Cy N PE PE' N' N 1) Line 2) Load 1) Line 2) Load Medical version (M5) protection class II L L' L1 1) F1 2) R Cx L2 F2 N' N 1) Line 2) Load Derating Curves 2-pole Admissible power acceptance in Watt 2.0 1.5 I = 1.0 In I = 0.7 In 1.0 I = << In 0.5 0.0 0 20 40 60 80 100 Ambient air temperature Ta C 4 Admissible power acceptance in Watt 1-pole 1.4 1.2 1.0 I = 1.0 In 0.8 I = 0.7 In 0.6 I = << In 0.4 0.2 0.0 0 20 40 60 80 100 Ambient air temperature Ta C EMC Products L' L1 1) F1 2) R Cx L2 PE' F2 N' KMF Power Entry Modules with Line Filter https://www.schurter.com /PG06 Attenuation Loss - - - - 50 differential mode _____ 50 common mode Standard version 1A 2A 4A 6A 2A 4A 6A 10 A Medical version (M5) 1A 10 A All Variants Rated Current [A] Filter-Type Fuseholder Line Switch Protection Class Order Number 1 Standard Version 1-pole 2-pole I KMF1.1211.11 2 Standard Version 1-pole 2-pole I KMF1.1221.11 4 Standard Version 1-pole 2-pole I KMF1.1241.11 6 Standard Version 1-pole 2-pole I KMF1.1261.11 10 Standard Version 1-pole 2-pole I KMF1.1291.11 1 Standard Version 2-pole 2-pole I KMF1.1111.11 2 Standard Version 2-pole 2-pole I KMF1.1121.11 4 Standard Version 2-pole 2-pole I KMF1.1141.11 6 Standard Version 2-pole 2-pole I KMF1.1161.11 10 Standard Version 2-pole 2-pole I KMF1.1191.11 1 Medical Version (M5) 1-pole 2-pole I KMF1.1213.11 2 Medical Version (M5) 1-pole 2-pole I KMF1.1223.11 4 Medical Version (M5) 1-pole 2-pole I KMF1.1243.11 6 Medical Version (M5) 1-pole 2-pole I KMF1.1263.11 10 Medical Version (M5) 1-pole 2-pole II KMF0.2293.11 EMC Products 5 KMF Rated Current [A] Power Entry Modules with Line Filter https://www.schurter.com /PG06 Filter-Type Fuseholder Line Switch Protection Class Order Number 10 Medical Version (M5) 1-pole 2-pole I KMF1.1293.11 1 Medical Version (M5) 2-pole 2-pole II KMF0.2113.11 1 Medical Version (M5) 2-pole 2-pole I KMF1.1113.11 2 Medical Version (M5) 2-pole 2-pole II KMF0.2123.11 2 Medical Version (M5) 2-pole 2-pole I KMF1.1123.11 4 Medical Version (M5) 2-pole 2-pole II KMF0.2143.11 4 Medical Version (M5) 2-pole 2-pole I KMF1.1143.11 6 Medical Version (M5) 2-pole 2-pole II KMF0.2163.11 6 Medical Version (M5) 2-pole 2-pole I KMF1.1163.11 10 Medical Version (M5) 2-pole 2-pole II KMF0.2193.11 10 Medical Version (M5) 2-pole 2-pole I KMF1.1193.11 Most Popular. Availability for all products can be searched real-time:https://www.schurter.com/en/Stock-Check/Stock-Check-SCHURTER Packaging unit 20 Pcs Required Accessory Description Fusedrawer 2 Fusedrawer fur Fuse Links 5x20 mm, with or without Voltage Selector Insert Fingergrip, 2-pole 4301.1401 Extra-Safe, 2-pole 4301.1403 Fingergrip, 1-pole 4301.1405 Extra-Safe, 1-pole 4301.1407 ... Accessories Wire Harness Wire harness for SCHURTER products Assorted Covers Rear Cover 0859.0076 Cord retaining kits Cord retaining strain relief Flat head, A 6 EMC Products 4700.0001 KMF Power Entry Modules with Line Filter https://www.schurter.com /PG06 Mating Outlets/Connectors Category / Description Appliance Outlet Overview complete IEC Appliance Outlet F, Screw-on Mounting, Front Side, Solder Terminal 4787 IEC Appliance Outlet F, Snap-in Mounting, Front Side, Solder or Quick-connect Terminal 4788 IEC Appliance Outlet F or H, Screw-on Mounting, Front Side, Solder, PCB or Quick-connect Terminal 5091 Appliance Outlet further types to KMF Connector Overview complete 4782 Mounting: Power Cord, 3 x 1 mm / 3 x 18 AWG, Cable, Connector: IEC C13 4782 4022 Mounting: Power Supply Cord, 3 x 1.5 mm, Screw clamps, Connector: IEC C13 4022 4785 Mounting: Power Cord, 3 x 1 mm / 3 x 18 AWG, Cable, Connector: IEC C13 4785 4300-06 Mounting: Power Cord, 3 x 1 mm / 3 x 18 AWG, Cable, Connector: IEC C13 4300-06 4012 Mounting: Power Supply Cord, 3 x 1.5 mm, Screw clamps, Connector: IEC C13 4012 Connector further types to KMF ... Mating Outlets/Connectors shuttered Power Cord Overview complete Power cord with IEC connector C17, V-Lock, straight VAC17KS 02.12.2017 Power Cord further types to KMF The specifications, descriptions and illustrations indicated in this document are based on current information. All content is subject to modifications and amendments. Information furnished is believed to be accurate and reliable. However, users should independently evaluate the suitability and test each product selected for their own applications. EMC Products 7 Mouser Electronics Authorized Distributor Click to View Pricing, Inventory, Delivery & Lifecycle Information: Schurter: KMF1.1121.1101 KMF1.1123.1101 KMF8.0001 KMF1.1161.1101 KMF1.1123.1102 KMF1.1191.1102 KMF0.2143.11 KMF0.2193.11 KMF0.2163.11 KMF0.2123.11 KMF0.2113.11 KMF0.2293.11