Data Sheet
June 15, 2009
QR W010/025/035/040 Series Power Modules; dc-dc Converters
36 Vdc - 75 Vdc Input, 1.0 to 12 Vdc Output; 10 A to 40 A
Document Name: DS03-113 ver. 4.3
PDF Name: qrw-series_ds.pdf
Applications
n
Enterprise Networks
n
Wireless Networks
n
Access and Optical Network Equipment
n
Enterprise Networks
n
Latest generation IC’s (DSP, FPGA, ASIC) and Micropro-
cessor-powered applications.
Options
n
Positive Remote On/Off logic
n
Case ground pin (-H Base plate version)
n
Auto restart after fault shutdown
Features
n
Compatible with RoHS EU Directive 2002/95/EC (-Z V e r-
sions)
n
Compatible in RoHS EU Directive 2002/95/EC with lead
solder exemption (non -Z versions)
n
Delivers up to 40A output current
n
Ultra High efficiency: 91% at 3.3V full load
n
Industry standard Quarter Brick:
57.9 mm x 36.8 mm x 9.5 mm
(2.28 in x 1.45 in x 0.375 in)
n
Improved Thermal performance
23A at 70°C at 1ms-1 (200LFM) for 3.3Vo
n
High power density: 100W/in3
n
Low output ripple and noise
n
Low output voltages down to 1V:
Supports migration to future IC and microprocessor supply
voltages
n
2:1 input voltage
n
Remote Sense
n
Remote On/Of f
n
Constant switching frequency
n
Output overvoltage and Overcurrent protection
n
Overtemperature protection
n
Adjustable output voltage (+10% / -20%)
n
Meets the voltage and current requirements for
ETSI 300-132-2 and complies with and is approved for
Basic Insulation rating per EN60950-1
n
UL* 60950 Recognized, CSA C22.2 No. 60950-0 0 Certi-
fied, and VDE 0805 (IEC60950, 3rd edition) Licensed
n
CE mark meets 73/23/EEC and 93/68/EEC directives§
n
ISO** 9001 certified manufacturing facilities
RoHS Compliant
Description
The QRW-series dc-dc converters are a new generation of DC/DC power modules designed for optimum
efficiency and power density. The QRW series provide up to 40A output current in an industry standard quarter brick, which makes
it an ideal choice for small space, high current and low voltage applications. The converter uses synchronous rectification technol-
ogy and innovative packaging techniques to achieve ultra high efficiency reaching 91% at 3.3V full load. Thanks to the ultra high
efficiency of this converter, the power dissipation is such that for most applications a heat sink is not required. In addition, the
QRW-series supports future migration of semiconductor and microprocessor supply voltages down to 1.0V.
* UL is a registered trademark of Underwriters Laboratories, Inc.
CSA is a registered trademark of Canadian Standards Association.
VDE is a trademark of Verband Deutscher Elektrotechniker e.V.
§ This product is intended for integration into end-use equipment. All the required procedures for CE marking of end-use equipment should be followed.
(The CE mark is placed on selected products.)
** ISO is a registered trademark of the Internation Organization of Standards
Lineage Power 2
Data Sheet
June 15, 200936 Vdc - 75 Vdc Input, 1.0 to 12 Vdc Output; 10 A to 40 A
QRW010/025/035/040 Series Power Modules; dc-dc Converters
Absolute Maximum Ratings
Stresses in excess of the absolute maximum ratings can cause permanent damage to th e device. These are absolute stress
ratings only, functional operation of the device is not implied at these or any other con ditions in excess of those given in th e
operations sections of the data sheet. Exposure to absolute maximum ratings for extended periods can adversely affect the
device reliabiltiy.
Electrical Specifications
Unless otherwise indicated, specifications apply over all operating input voltage, resistive load, and temperature conditions.
CAUTION: This power module is not internally fused. An input line fuse must always be used.
This power module can be used in a wide variety of application s , ranging from simple stand-alone operation to an integrated
part of a sophisticated power architecture. To preserve maximum flexibility , internal fusing is not included; however , to achieve
maximum safety and system protection, always use an input line fuse. The safety agencies require a normal-blow fuse with a
maximum rating of 10 A (see Safety Considerations section). Based on the information provid ed in this data sheet on in rush
energy and maximum dc input current, the same type of fuse with a lower rating can be used. Refer to the fuse manufacturer’s
data for further information.
Parameter Device Symbol Min Max Unit
Input Voltage:Continuous
Transient (100ms) All VI
VI, trans
80
100 Vdc
Vdc
Operating Ambient Temperature
(See Thermal Considerations section) All TA –40 85 °C
Storage Temperature All Tstg –55 125 °C
I/O Isolation Voltage (100% factory Hi-Pot tested)
When using optional case ground pin
(option 7)
1500
700 Vdc
Vdc
Parameter Device Symbol Min Typ Max Unit
Operating Input Voltage All VIN 36 48 75 Vdc
Maximum Input Current
(VI = 0 V to 75 V; IO = IO, max) All 4.5 Adc
Inrush Transient All I2t1A
2s
Input Reflected Ripple Current, peak-peak
(5 Hz to 20 MHz, 12 µH source impedance
See Test configuration section)
All 16 mAp-p
Input Ripple Rejection (120 Hz) All 60 dB
Lineage Power 3
Data Sheet
June 15, 200936 Vdc - 75 Vdc Input, 1.0 to 12 Vdc Output; 10 A to 40 A
QRW010/025/035/040 Series Power Modules; dc-dc Converters
Electrical Specifications (continued)
Output Specifications for the QRW040A0S1R0 (Vo = 1.0Vdc)
Isolation Specifications
General Specifications
Parameter Device Symbol Min Typ Max Unit
Output Voltage Set Point
(VI = 48 Vdc; IO = IO, min to IO, max, TA = 25 °C) P Vo 0.99 1.0 1.01 Vdc
Output Voltage
(Over all operating input voltage, resistive load, and
temperature conditions at steady state until end of life.)
P Vo 0.98 1.02 Vdc
Output Regulation:
Line (VI = VI, min to VI, max)
Load (IO = IO, min to IO, max)
Temperature (TA = TA, min to TA, max)
P—
0.1
0.1
15
0.3
0.3
50
%, VO, set
%, VO, set
mV
Output Ripple and Noise
RMS (5 Hz to 20 MHz bandwidth)
Peak-to-peak (5 Hz to 20 MHz bandwidth) P—
30
80 mVrms
mVp-p
External Load Capacitance 25,000 µF
Output Current
(Vo =90% of VO, nom.) PIO0.040Adc
Output Current-limit Inception
(VO = 90% of VO, set) P IO, lim 49 Adc
Output Short-circuit Current (Average)VO = 0.25 V Latched off
Efficiency
(VI = VIN, nom; IO = IO, max), TA = 25 °C η—83— %
Switching Frequency All fSW 300 kHz
Dynamic Response
(DIO/Dt = 1 A/10 µs, VI = 48 V, TA = 25 ° C); tested
with a 220 µF aluminium and a 1.0 µf ceramic
capacitor across the load.):
Load Change from
IO = 50% to 75% of IO, max:
Peak Deviation
Settling Time
(VO < 10% of peak deviation)
Load Change from IO = 50% to 25%
of IO, max :
Peak Deviation
Settling Time
(VO < 10% of peak deviation)
160
200
180
200
mV
µs
mV
µs
Parameter Symbol Min Typ Max Unit
Isolation Capacitance Ciso 5600 PF
Isolation Resistance Riso 10 MΩ
Parameter Min Typ Max Unit
Calculated MTBF (Io = 80% of Io, max Ta = 40 °C TBD Hours
Weight 37(1.31) g (oz.)
Lineage Power 4
Data Sheet
June 15, 200936 Vdc - 75 Vdc Input, 1.0 to 12 Vdc Output; 10 A to 40 A
QRW010/025/035/040 Series Power Modules; dc-dc Converters
Feature Specifications
Unless otherwise indicated, specifications apply over all operating input voltage, resistive load, and temperature conditions.
See Feature Descriptions for additional information .
Parameter Symbol Min Typ Max Unit
Remote On/Off Signal Interface*
(VI = 0 V to 75 V; open collector or equivalent compatible; signal
referenced to VI(–) terminal; see Figure 52
and Feature Descriptions.):
Preferred Logic:
Logic Low—Module On
Logic High—Module Off
Optional Logic:
Logic Low—Module Off
Logic High—Module On
Logic Low:
At Ion/off = 1.0 mA
At Von/off = 0.0 V
Logic High:
At Ion/off = 0.0 µA
Leakage Current
Turn-on Time; see Typical Start-up Curve(IO = IO max;
Vo within ±1% of steady state)
Von/off
Ion/off
Von/off
Ion/off
0
2
1.2
1.0
15
50
4
V
mA
V
µA
ms
Output Voltage Adjustment
(See Feature Descriptions):
Output Voltage Remote-sense Range
Output Voltage Set-point Adjustment Range (trim)
80
10
110 %VO,rated
%V0,nom
Output Overvoltage Protection VO, ovsd 1.25 1.5 V
Overtemperaute Protection (IO = IO, max) Tref1 127 °C
Lineage Power 5
Data Sheet
June 15, 200936 Vdc - 75 Vdc Input, 1.0 to 12 Vdc Output; 10 A to 40 A
QRW010/025/035/040 Series Power Modules; dc-dc Converters
Characteristic Curves
The following figures provi de typical characteri stics curves for the QRW040A0S1R0 (VO = 1.0 V) module at room temperature
(TA = 25 °C).The figures are identical for both on/off configurations.
Figure 1. Input Voltage and Current Characteristics.
Figure 2. Converter Efficiency vs. Output Current.
Figure 3. Output Ripple Voltage (IO = IO, max).
Tested with a 220µF aluminium and a 1.0µF ceramic
capacitor across the load.
Figure 4. Transient Response to Step decrease in
Load from 50% to 25% of Full Load (VI = 48
Vdc).
Figure 5. T ran sient Re sponse to St ep Incr ease in Load
from 50% to 75% of Full Load (VI = 48 Vdc).
Figure 6. Start-up from Remote On/Off (IO = IO, max).
70
72
74
76
78
80
82
84
86
88
0 5 10 15 20 25 30 35 40
OUTPUT VOLT AGE, V o ( V)
(50 mV/d iv)
TIME, t (1.00 µs/div)
TIME, t (0.1ms/div)
OUTPUT VOLTAGE, Io (A)
(10A/div) OUTPUT CURRENT ,
(10 0 m v/div) Vo (V
TIME, t (0.1ms/div)
OUTP UT VOLT AGE, Io (A)
(10A/div) OUTPUT CURRENT,
(10 0 m v /d iv) Vo (V)
TIME, t (2ms/div)
REMOTE ON/OFF
V on/of f ( V ) OUTPU T VOLTAGE
(0.5 V /d i v) (V)
Lineage Power 6
Data Sheet
June 15, 200936 Vdc - 75 Vdc Input, 1.0 to 12 Vdc Output; 10 A to 40 A
QRW010/025/035/040 Series Power Modules; dc-dc Converters
Electrical Specifications (continued)
Output Specifications for the QRW040AP (Vo = 1.2Vdc)
Isolation Specifications
General Specifications
Parameter Device Symbol Min Typ Max Unit
Output Voltage Set Point
(VI = 48 Vdc; IO = IO, min to IO, max, TA = 25 °C) P Vo 1.18 1.2 1.22 Vdc
Output Voltage
(Over all operating input voltage, resistive load, and
temperature conditions at steady state until end of life.)
P Vo 1.16 1.24 Vdc
Output Regulation:
Line (VI = VI, min to VI, max)
Load (IO = IO, min to IO, max)
Temperature (TA = TA, min to TA, max)
P—
0.05
0.05
15
0.3
0.3
50
%, VO, set
%, VO, set
mV
Output Ripple and Noise
RMS (5 Hz to 20 MHz bandwidth)
Peak-to-peak (5 Hz to 20 MHz bandwidth) P—
30
80 mVrms
mVp-p
External Load Capacitance 25,000 µF
Output Current
(Vo =90% of VO, nom.) PIO0.040Adc
Output Current-limit Inception
(VO = 90% of VO, set) P IO, lim 45 Adc
Output Short-circuit Current (Average)VO = 0.25 V Latched off
Efficiency
(VI = VIN, nom; IO = IO, max), TA = 25 °C η—85— %
Switching Frequency All fSW 300 kHz
Dynamic Response
(DIO/Dt = 1 A/10 µs, VI = 48 V, TA = 25 ° C); tested
with a 220 µF aluminium and a 1.0 µf ceramic
capacitor across the load.):
Load Change from
IO = 50% to 75% of IO, max:
Peak Deviation
Settling Time
(VO < 10% of peak deviation)
Load Change from IO = 50% to 25%
of IO, max :
Peak Deviation
Settling Time
(VO < 10% of peak deviation)
120
200
120
200
mV
µs
mV
µs
Parameter Symbol Min Typ Max Unit
Isolation Capacitance Ciso 5600 PF
Isolation Resistance Riso 10 MΩ
Parameter Min Typ Max Unit
Calculated MTBF (Io = 80% of Io, max Ta = 40 °C), Issue 1, M1, C1 1,271,000 Hours
Weight 37(1.31) g (oz.)
Lineage Power 7
Data Sheet
June 15, 200936 Vdc - 75 Vdc Input, 1.0 to 12 Vdc Output; 10 A to 40 A
QRW010/025/035/040 Series Power Modules; dc-dc Converters
Feature Specifications
Unless otherwise indicate d, specifications apply over all operating input voltage, resistive load, and temperature conditions.
See Feature Descriptions for additional information.
* A Minimum OFF Period of 1 sec is recommended.
Parameter Symbol Min Typ Max Unit
Remote On/Off Signal Interface*
(VI = 0 V to 75 V; open collector or equivalent compatible; signal
referenced to VI(–) terminal; see Figure 52
and Feature Descriptions.):
Preferred Logic:
Logic Low—Module On
Logic High—Module Off
Optional Logic:
Logic Low—Module Off
Logic High—Module On
Logic Low:
At Ion/off = 1.0 mA
At Von/off = 0.0 V
Logic High:
At Ion/off = 0.0 µA
Leakage Current
Turn-on Time; see Typical Start-up Curve(IO = IO max;
Vo within ±1% of steady state)
Von/off
Ion/off
Von/off
Ion/off
0
2
1.2
1.0
15
50
4
V
mA
V
µA
ms
Output Voltage Adjustmen t
(See Feature Descriptions):
Output Voltage Remote-sense Range
Output Voltage Set-point Adjustment Range (tr im)
80
10
110 %VO,rated
%V0,nom
Output Overvoltage Protection VO, ovsd 1.42 1.58 V
Overtemperaute Protection (IO = IO, max) Tref1 127 °C
Lineage Power 8
Data Sheet
June 15, 200936 Vdc - 75 Vdc Input, 1.0 to 12 Vdc Output; 10 A to 40 A
QRW010/025/035/040 Series Power Modules; dc-dc Converters
Characteristic Curves
The following figures provide typical characteristics curves for the QRW040A0P (VO = 1.2 V) module at room temperature (T A
= 25 °C)
Figure 7. Input Voltage and Current Characteristics.
Figure 8. Converter Efficiency vs. Output Current.
Figure 9. Output Ripple Voltage (IO = IO, max).
Tested with a 220µF aluminium and a 1.0µF ceramic
capacitor across the load.
Figure 10. Transient Response to Step Decrease in
Load from 50% to 25% of Full Load
(VI = 48 Vdc).
Figure 11. Transient Response to Step Increase in
Load from 50% to 75% of Full Load
(VI = 48 Vdc).
Tested with a 10µF aluminium and a 1.0µF tantalum capacitor
across the load.
Figure 12. Start-up from Remote On/Off (IO = IO, max).
0
0.2
0.4
0.6
0.8
1
1.2
1.4
1.6
1.8
2
0 1020304050607080
INPUT CURRENT, I
I
(A)
I
O
= 40 A
I
O
= 20 A
I
O
= 4 A
70
72
74
76
78
80
82
84
86
88
0 4 8 1216202428323640
OUTPUT CURRENT, I
O
(A)
EFFICIENCY,
η
(%)
V
I
= 36 V
V
I
= 48 V
V
I
= 75 V
TIME t, (1µs/div)
36V, 40A
48V, 40A
75V, 40A
OUTPUT VOLTAGE, VO (V)
(50 mV/div)
T IME , t ( .1 ms/div )
OUTPUT CURRENT, I (A)
O
(1 0 A/div ) O U T P U T V OL TA G E , V (V )
O
(1 00 mV/d iv)
Lineage Power 9
Data Sheet
June 15, 200936 Vdc - 75 Vdc Input, 1.0 to 12 Vdc Output; 10 A to 40 A
QRW010/025/035/040 Series Power Modules; dc-dc Converters
Electrical Specifications (continued)
Output Specifications for the QRW040AOM (Vo = 1.5Vdc)
Isolation Specifications
General Specifications
Parameter Device Symbol Min Typ Max Unit
Output Voltage Set Point
(VI = 48 Vdc; IO = IO, min to IO, max, TA = 25 °C) MVo1.471.51.52Vdc
Output Voltage
(Over all operating input voltage, resistive load, and
temperature conditions at steady state until end of life.)
MVo1.451.55Vdc
Output Regulation:
Line (VI = VI, min to VI, max)
Load (IO = IO, min to IO, max)
Temperature (TA = TA, min to TA, max)
M—
0.05
0.05
15
0.2
0.2
50
%, VO, set
%, VO, set
mV
Output Ripple and Noise
RMS (5 Hz to 20 MHz bandwidth)
Peak-to-peak (5 Hz to 20 MHz bandwidth) M—
20
100 mVrms
mVp-p
External Load Capacitance 25,000 µF
Output Current
(Vo =90% of VO, nom.) MIO0.040Adc
Output Current-limit Inception
(VO = 90% of VO, set) M IO, lim 47 Adc
Output Short-circuit Current (Average)VO = 0.25 V Latched off
Efficiency
(VI = VIN, nom; IO = IO, max), TA = 25 °C η—86.5— %
Switching Frequency All fSW 300 kHz
Dynamic Response
(DIO/Dt = 1 A/10 µs, VI = 48 V, TA = 25 °C); tested
with a 220 µF aluminium and a 1.0 µf ceramic
capacitor across the load.):
Load Change from
IO = 50% to 75% of IO, max:
Peak Deviation
Settling Time
(VO < 10% of peak deviation)
Load Change from IO = 50% to 25%
of IO, max :
Peak Deviation
Settling Time
(VO < 10% of peak deviation)
120
200
120
200
mV
µs
mV
µs
Parameter Symbol Min Typ Max Unit
Isolation Capacitance Ciso 5600 PF
Isolation Resistance Riso 10 MΩ
Parameter Min Typ Max Unit
Calculated MTBF (Io = 80% of Io, max Ta = 40 °C), Issue 1, M1, C1 1,548,000 Hours
Weight 38(1.54) g (oz.)
Lineage Power 10
Data Sheet
June 15, 200936 Vdc - 75 Vdc Input, 1.0 to 12 Vdc Output; 10 A to 40 A
QRW010/025/035/040 Series Power Modules; dc-dc Converters
Feature Specifications
Unless otherwise indicated, specifications apply over all operating input voltage, resistive load, and temperature conditions.
See Feature Descriptions for additional information .
* A Minimum OFF Period of 1 sec is recommended.
Parameter Symbol Min Typ Max Unit
Remote On/Off Signal Interface*
(VI = 0 V to 75 V; open collector or equivalent compatible; signal
referenced to VI(–) terminal; see Figure 52
and Feature Descriptions.):
Preferred Logic:
Logic Low—Module On
Logic High—Module Off
Optional Logic:
Logic Low—Module Off
Logic High—Module On
Logic Low:
At Ion/off = 1.0 mA
At Von/off = 0.0 V
Logic High:
At Ion/off = 0.0 µA
Leakage Current
Turn-on Time; see Typical Start-up Curve(IO = IO max;
Vo within ±1% of steady state)
Von/off
Ion/off
Von/off
Ion/off
0
2
1.2
1.0
15
50
4
V
mA
V
µA
ms
Output Voltage Adjustment
(See Feature Descriptions):
Output Voltage Remote-sense Range
Output Voltage Set-point Adjustment Range (trim)
80
10
110 %VO,rated
%V0,nom
Output Overvoltage Protection VO, ovsd 1.69 2.07 V
Overtemperaute Protection (IO = IO, max) Tref1 127 °C
Lineage Power 11
Data Sheet
June 15, 200936Vdc - 75 Vdc Input, 1.0 to 12Vdc Output; 10A to 40A
QRW010/025/035/040 Series Power Modules; dc-dc Converters
Characteristic Curves
The following figures provide typical characteristics curves for the QRW040A0M (VO = 1.5 V) module at room temperature (TA
= 25 °C)
Figure 13. Input Voltage and Current Characteristics.
Figure 14. Converter Efficiency vs. Output Current.
Figure 15. Output Ripple Voltage (IO = IO, max).
Tested with a 220µF aluminium and a 1.0µF ceramic capacitor
across the load.
Figure 16. T ransient Response to Step Decrease in
Load from 50% to 25% of Full Load (VI = 48
Vdc).
Figure 17. Transient Re sponse to St ep Incr ease in Load
from 50% to 75% of Full Load (VI = 48 Vdc).
Tested with a 10µF aluminium and a 1.0µF tantalum cap acitor across
the load.
Figure 18. Start-up from Remote On/Off (IO = IO, max).
0
0.5
1
1.5
2
2.5
01020304050607080
IN PUT V OLTAG E, VI (V)
INPUT CURRENT, II (A)
EFFICIENCY, (%)
η
OUTPUT CURRENT, Io (A)
TIME,t (1 µs/div)
36V, 40A
48V, 40A
75V, 40A
OUTPUT VOLTAGE,
V
O
(V)
(50 mV/div)
TIME, t (.1 ms/div)
OUTPUT CURRENT, I
O
(A)
(10 A/div) OUTPUT VOLTAGE, V
O
(V)
(100 mV/div)
TIME, t (.1 ms/div)
OUTPUT CURRENT, I
O
(A)
(10 A/div) OUTPUT VOLTAGE, V
O
(V)
(100 mV/div)
TIME, t (2 ms/div)
OUTPUT VOLTAGE, V
O
(V)
(.5 V/div)
REMOTE ON/OFF PIN,
V
ON/OFF
(V)
Lineage Power 12
Data Sheet
June 15, 200936 Vdc - 75 Vdc Input, 1.0 to 12 Vdc Output; 10 A to 40 A
QRW010/025/035/040 Series Power Modules; dc-dc Converters
Electrical Specifications (continued)
Output Specifications for the QRW040A0Y (Vo = 1.8Vdc)
Isolation Specifications
General Specifications
Parameter Device Symbol Min Typ Max Unit
Output Voltage Set Point
(VI = 48 Vdc; IO = IO, min to IO, max, TA = 25 °C) Y Vo 1.77 1.8 1.83 Vdc
Output Voltage
(Over all operating input voltage, resistive load, and
temperature conditions at steady state until end of life.)
Y Vo 1.75 1.85 Vdc
Output Regulation:
Line (VI = VI, min to VI, max)
Load (IO = IO, min to IO, max)
Temperature (TA = TA, min to TA, max)
Y—
0.05
0.05
15
0.2
0.2
50
%, VO, set
%, VO, set
mV
Output Ripple and Noise
RMS (5 Hz to 20 MHz bandwidth)
Peak-to-peak (5 Hz to 20 MHz bandwidth) Y—
35
100 mVrms
mVp-p
External Load Capacitance 25,000 µF
Output Current
(Vo =90% of VO, nom.) YIO0.040Adc
Output Current-limit Inception
(VO = 90% of VO, set) Y IO, lim 45 Adc
Output Short-circuit Current (Average)VO = 0.25 V Latched off
Efficiency
(VI = VIN, nom; IO = IO, max), TA = 25 °C η—88— %
Switching Frequency All fSW 300 kHz
Dynamic Response
(DIO/Dt = 1 A/10 µs, VI = 48 V, TA = 25 ° C); tested
with a 220 µF aluminium and a 1.0 µf ceramic
capacitor across the load.):
Load Change from
IO = 50% to 75% of IO, max:
Peak Deviation
Settling Time
(VO < 10% of peak deviation)
Load Change from IO = 50% to 25%
of IO, max :
Peak Deviation
Settling Time
(VO < 10% of peak deviation)
200
200
200
200
mV
µs
mV
µs
Parameter Symbol Min Typ Max Unit
Isolation Capacitance Ciso 5600 PF
Isolation Resistance Riso 10 MΩ
Parameter Min Typ Max Unit
Calculated MTBF (IO = 80% of IO, max TA = 40 °C) TBD Hours
Weight 38(1.34) g (oz.)
Lineage Power 13
Data Sheet
June 15, 200936 Vdc - 75 Vdc Input, 1.0 to 12 Vdc Output; 10 A to 40 A
QRW010/025/035/040 Series Power Modules; dc-dc Converters
Feature Specifications
Unless otherwise indicate d, specifications apply over all operating input voltage, resistive load, and temperature conditions.
See Feature Descriptions for additional information.
* A Minimum OFF Period of 1 sec is recommended.
Parameter Symbol Min Typ Max Unit
Remote On/Off Signal Interface*
(VI = 0 V to 75 V; open collector or equivalent compatible; signal
referenced to VI(–) terminal; see Figure 52
and Feature Descriptions.):
Preferred Logic:
Logic Low—Module On
Logic High—Module Off
Optional Logic:
Logic Low—Module Off
Logic High—Module On
Logic Low:
At Ion/off = 1.0 mA
At Von/off = 0.0 V
Logic High:
At Ion/off = 0.0 µA
Leakage Current
Turn-on Time; see Typical Start-up Curve(IO = IO max;
Vo within ±1% of steady state)
Von/off
Ion/off
Von/off
Ion/off
0
2
1.2
1.0
15
50
4
V
mA
V
µA
ms
Output Voltage Adjustmen t
(See Feature Descriptions):
Output Voltage Remote-sense Range
Output Voltage Set-point Adjustment Range (tr im)
80
10
110 %VO,rated
%V0,nom
Output Overvoltage Protection VO, ovsd 2.0 2.5 V
Overtemperaute Protection (IO = IO, max) Tref1 127 °C
Lineage Power 14
Data Sheet
June 15, 200936 Vdc - 75 Vdc Input, 1.0 to 12 Vdc Output; 10 A to 40 A
QRW010/025/035/040 Series Power Modules; dc-dc Converters
Characteristic Curves
The following figures provide typical characteristics curves for the QRW040A0Y (VO = 1.8 V) module at room temperature (T A
= 25 °C)
Figure 19. Input Voltage and Current Characteristics.
Figure 20. Converter Efficiency vs. Output Current.
Figure 21. Output Ripple Voltage (IO = IO, max).
Tested with a 220µF aluminium and a 1.0µF ceramic capacitor
across the load.
Figure 22. Transient Response to Step Decrease in
Load from 50% to 25% of Full Load
(VI = 48 Vdc).
Figure 23. Transient Response to Step Increase in
Load from 50% to 75% of Full Load
(VI = 48 Vdc).
Tested with a 10µF aluminium and a 1.0µF tantalum capacitor
across the load.
Figure 24. Start-up from Remote On/Off (IO = IO, max).
3.0
2.5
2.0
1.5
1.0
0.5
0
INPUT CURRENT, II (A)
INPUT V OLTAGE, VI (V)
IO = 50%
0 2040608
0
IO = 100%
IO = 10%
EFFICIENCY, (%)
η
OUTPUT CURRENT, Io (A)
TIME, t (1 µs/div)
OUTPUT V OLTAGE, V
O
(V)
(50 mV/div)
V
I
= 36 V
V
I
= 48 V
V
I
= 75 V
TIME, t (0.1 ms/div)
OUTPUT V OLTAGE,
VO (V) (100 mV/div)
OUTPUT CURRENT,
IO (A) (10 A/div)
TIME, t (0.1 ms/div)
OUTPUT V OLTAGE,
VO (V) (100 mV/div)
OUTPUT CURRENT,
IO (A) (10 A/div)
TIME, t (2 ms/div)
OUTPUT V OLTAGE,
V
O
(V) (0.5 V/div)
REMOTE ON/OFF,
V
ON/OFF
(5 V/div)
Lineage Power 15
Data Sheet
June 15, 200936 Vdc - 75 Vdc Input, 1.0 to 12 Vdc Output; 10 A to 40 A
QRW010/025/035/040 Series Power Modules; dc-dc Converters
Electrical Specifications (continued)
Output Specifications for the QRW035A0G (Vo = 2.5Vdc)
Isolation Specifications
General Specifications
Parameter Device Symbol Min Typ Max Unit
Output Voltage Set Point
(VI = 48 Vdc; IO = IO, min to IO, max, TA = 25 °C) G Vo 2.47 2.5 2.53 Vdc
Output Voltage
(Over all operating input voltage, resistive load, and
temperature conditions at steady state until end of life.)
G Vo 2.42 2.58 Vdc
Output Regulation:
Line (VI = VI, min to VI, max)
Load (IO = IO, min to IO, max)
Temperature (TA = TA, min to TA, max)
G—
0.05
0.05
15
0.2
0.2
50
%, VO, set
%, VO, set
mV
Output Ripple and Noise
RMS (5 Hz to 20 MHz bandwidth)
Peak-to-peak (5 Hz to 20 MHz bandwidth) G—
35
100 mVrms
mVp-p
External Load Capacitance 25,000 µF
Output Current
(Vo =90% of VO, nom.) GIO0.035Adc
Output Current-limit Inception
(VO = 90% of VO, set) G IO, lim 39 Adc
Output Short-circuit Current (Average)VO = 0.25 V Latched off
Efficiency
(VI = VIN, nom; IO = IO, max), TA = 25 °C η—90— %
Switching Frequency All fSW 300 kHz
Dynamic Response
(DIO/Dt = 1 A/10 µs, VI = 48 V, TA = 25 ° C); tested
with a 220 µF aluminium and a 1.0 µf ceramic
capacitor across the load.):
Load Change from
IO = 50% to 75% of IO, max:
Peak Deviation
Settling Time
(VO < 10% of peak deviation)
Load Change from IO = 50% to 25%
of IO, max :
Peak Deviation
Settling Time
(VO < 10% of peak deviation)
150
200
150
200
mV
µs
mV
µs
Parameter Symbol Min Typ Max Unit
Isolation Capacitance Ciso 5600 PF
Isolation Resistance Riso 10 MΩ
Parameter Min Typ Max Unit
Calculated MTBF (IO = 80% of IO, max TA = 40 °C) TBD Hours
Weight 38(1.34) g (oz.)
Lineage Power 16
Data Sheet
June 15, 200936 Vdc - 75 Vdc Input, 1.0 to 12 Vdc Output; 10 A to 40 A
QRW010/025/035/040 Series Power Modules; dc-dc Converters
Feature Specifications
Unless otherwise indicate d, specifications apply over all operating input voltage, resistive load, and temperature conditions.
See Feature Descriptions for additional information.
* A Minimum OFF Period of 1 sec is recommended.
Parameter Symbol Min Typ Max Unit
Remote On/Off Signal Interface*
(VI = 0 V to 75 V; open collector or equivalent compatible; signal
referenced to VI(–) terminal; see Figure 52
and Feature Descriptions.):
Preferred Logic:
Logic Low—Module On
Logic High—Module Off
Optional Logic:
Logic Low—Module Off
Logic High—Module On
Logic Low:
At Ion/off = 1.0 mA
At Von/off = 0.0 V
Logic High:
At Ion/off = 0.0 µA
Leakage Current
Turn-on Time; see Typical Start-up Curve(IO = IO max;
Vo within ±1% of steady state)
Von/off
Ion/off
Von/off
Ion/off
0
2
1.2
1.0
15
50
4
V
mA
V
µA
ms
Output Voltage Adjustmen t
(See Feature Descriptions):
Output Voltage Remote-sense Range
Output Voltage Set-point Adjustment Range (tr im)
80
10
110 %VO,rated
%V0,nom
Output Overvoltage Protection VO, ovsd 2.9 3.2 V
Overtemperaute Protection (IO = IO, max) Tref1 127 °C
Lineage Power 17
Data Sheet
June 15, 200936 Vdc - 75 Vdc Input, 1.0 to 12 Vdc Output; 10 A to 40 A
QRW010/025/035/040 Series Power Modules; dc-dc Converters
Characteristic Curves
The following figures provide typical characteristics curves for the QRW035A0G (VO = 2.5 V) module at room temperature (T A
= 25 °C)
Figure 25. Input Voltage and Current Characteristics.
Figure 26. Converter Efficiency vs. Output Current.
Figure 27. Output Ripple Voltage (IO = IO, max).
Tested with a 220µF aluminium and a 1.0µF ceramic capacitor
across the load.
Figure 28. Transient Response to Step Decrease in
Load from 50% to 25% of Full Load
(VI = 48 Vdc).
Figure 29. Transient Response to Step Increase in
Load from 50% to 75% of Full Load
(VI = 48 Vdc).
Tested with a 10µF aluminium and a 1.0µF tantalum capacitor
across the load.
Figure 30. Start-up from Remote On/Off (IO = IO, max).
0
0.5
1
1.5
2
2.5
3
3.5
0 5 10 15 20 25 30 35 40 45 50 55 60 65 70 75
INPUT VOLTAGE, V
I
(V)
INPUT CURRENT, I
I
(A)
I
O
= 35 A
I
O
= 17.5 A
I
O
= 3.5 A
70
75
80
85
90
95
0 4 7 1114182125283235
OUTPUT CURRENT, I
O
(A)
EFFICIENCY, η (% )
V
I
= 36 V
V
I
= 48 V
V
I
= 75 V
TIME t, (1µs/div)
OUTPUT VOLTAGE, V
O
(V)
(50 mV/div)
36V, 35A
48V, 35A
75V, 35A
TIME, t (.10 ms/div)
OUTPUT CURRENT, I
O
(A)
(5 A/div) OUTPUT VOLTAGE, V
O
(V
)
(50 mV/div)
TIME, t (.10 ms/div)
OUTPUT CURRENT, I
O
(A)
(5 A/div) OUTPUT VOLTAGE, V
O
(V)
(50 m V/div)
TIME, t (1 ms/div)
REMOTE ON/OFF PIN,
V
ON/OFF
(V) OUTPUT V OLTAGE, V
O
(V)
(1 V/div)
Lineage Power 18
Data Sheet
June 15, 200936 Vdc - 75 Vdc Input, 1.0 to 12 Vdc Output; 10 A to 40 A
QRW010/025/035/040 Series Power Modules; dc-dc Converters
Electrical Specifications (continued)
Output Specifications for the QRW035A0F (Vo = 3.3Vdc)
Isolation Specifications
General Specifications
Parameter Device Symbol Min Typ Max Unit
Output Voltage Set Point
(VI = 48 Vdc; IO = IO, min to IO, max, TA = 25 °C) F Vo 3.24 3.3 3.36 Vdc
Output Voltage
(Over all operating input voltage, resistive load, and
temperature conditions at steady state until end of life.)
F Vo 3.2 3.4 Vdc
Output Regulation:
Line (VI = VI, min to VI, max)
Load (IO = IO, min to IO, max)
Temperature (TA = TA, min to TA, max)
F—
0.05
0.05
15
0.2
0.2
50
%, VO, set
%, VO, set
mV
Output Ripple and Noise
RMS (5 Hz to 20 MHz bandwidth)
Peak-to-peak (5 Hz to 20 MHz bandwidth) F—
30
100 mVrms
mVp-p
External Load Capacitance 30,000 µF
Output Current
(Vo =90% of VO, nom.) FIO0.035Adc
Output Current-limit Inception
(VO = 90% of VO, set) F IO, lim 39 Adc
Output Short-circuit Current (Average)VO = 0.25 V Latched off
Efficiency
(VI = VIN, nom; IO = IO, max), TA = 25 °C η—91— %
Switching Frequency All fSW 300 kHz
Dynamic Response
(DIO/Dt = 1 A/10 µs, VI = 48 V, TA = 25 ° C); tested
with a 220 µF aluminium and a 1.0 µf ceramic
capacitor across the load.):
Load Change from
IO = 50% to 75% of IO, max:
Peak Deviation
Settling Time
(VO < 10% of peak deviation)
Load Change from IO = 50% to 25%
of IO, max :
Peak Deviation
Settling Time
(VO < 10% of peak deviation)
160
300
160
300
mV
µs
mV
µs
Parameter Symbol Min Typ Max Unit
Isolation Capacitance Ciso 5600 PF
Isolation Resistance Riso 10 MΩ
Parameter Min Typ Max Unit
Calculated MTBF (Io = 80% of Io, max Ta = 40 °C), Issue 1, M1, C1 1,700,000 Hours
Weight 37(1.31) g (oz.)
Lineage Power 19
Data Sheet
June 15, 200936 Vdc - 75 Vdc Input, 1.0 to 12 Vdc Output; 10 A to 40 A
QRW010/025/035/040 Series Power Modules; dc-dc Converters
Feature Specifications
Unless otherwise indicated, specifications apply over all operating input voltage, resistive load, and temperature conditions. See
Feature Descriptions for additional information.
* A Minimum OFF Period of 1 sec is recommended.
Parameter Symbol Min Typ Max Unit
Remote On/Off Signal Interface*
(VI = 0 V to 75 V; open collector or equivalent compatible; signal
referenced to VI(–) terminal; see Figure 52
and Feature Descriptions.):
Preferred Logic:
Logic Low—Module On
Logic High—Module Off
Optional Logic:
Logic Low—Module Off
Logic High—Module On
Logic Low:
At Ion/off = 1.0 mA
At Von/off = 0.0 V
Logic High:
At Ion/off = 0.0 µA
Leakage Current
Turn-on Time; see Typical Start-up Curve(IO = IO max;
Vo within ±1% of steady state)
Von/off
Ion/off
Von/off
Ion/off
0
2
1.2
1.0
15
50
4
V
mA
V
µA
ms
Output Voltage Adjustment
(See Feature Descriptions):
Output Voltage Remote-sense Range
Output Voltage Set-point Adjustment Range (trim)
80
0.5
110 V
%V0,nom
Output Overvoltage Protection VO, ovsd 3.8 4.6 V
Overtemperaute Protection (IO = IO, max) Tref1 127 °C
Lineage Power 20
Data Sheet
June 15, 200936 Vdc - 75 Vdc Input, 1.0 to 12 Vdc Output; 10 A to 40 A
QRW010/025/035/040 Series Power Modules; dc-dc Converters
Characteristic Curves
The following figures provide typical characteristics curves for the QRW035A0F (VO = 3.3 V) module at room temperature (TA
= 25 °C)
Figure 31. Input Voltage and Current Characteristics.
Figure 32. Converter Efficiency vs. Output Current.
Figure 33. Output Ripple Voltage (IO = IO, max).
Tested with a 220µF aluminium and a 1.0µF ceramic capacitor
across the load.
Figure 34. Transient Response to Step Decrease in
Load from 50% to 25% of Full Load
(VI = 48 Vdc).
Figure 35. Transient Response to Step Increase in
Load from 50% to 75% of Full Load
(VI = 48 Vdc).
Tested with a 10µF aluminium and a 1.0µF tantalum capacitor
across the load.
Figure 36. Start-up from Remote On/Off (IO = IO, max).
INPUT V OLTAGE, V
I
(V)
INPUT CURRENT, I
I
(A)
30 35 40 45 50 55 60 65 70 75 8
0
3.5
3.0
2.5
2.0
1.5
1.0
0.5
0.0
IO = 35 A
IO = 25 A
IO = 0 A
EFFICIENCY, η (%)
5 101520253035
92
90
88
86
84
82
80
VI = 36 V
VI = 48 V
VI = 75 V
TIME, t (2 µs/div)
OUTPUT V OLTAGE,
VO (V) (20 mV/div)
36 V, 35 A
48 V 35 A
75 V 35 A
OUTPUT CURRENT, I
O
(A)
(10 A/div) OUTPUT VOLTAGE, VO
(V
(100 mV/div)
TIME, t (.1ms/div)
OUTPUT CURRENT, I
O
(A)
(10 A/div) OUTPUT V OLTAGE, V
O
(V
)
(100 mV/div)
TIME, t (2 ms/div)
REMOTE ON/OFF (V)
(V on/off) OUT PUT V OL T AG E, Vo (V)
(1 V / d iv )
Lineage Power 21
Data Sheet
June 15, 200936 Vdc - 75 Vdc Input, 1.0 to 12 Vdc Output; 10 A to 40 A
QRW010/025/035/040 Series Power Modules; dc-dc Converters
Electrical Specifications (continued)
Output Specifications for the QRW025A0A (Vo = 5.0 Vdc)
Isolation Specifications
General Specifications
Parameter Device Symbol Min Typ Max Unit
Output Voltage Set Point
(VI = 48 Vdc; IO = IO, min to IO, max, TA = 25 °C) A Vo 4.95 5.0 5.05 Vdc
Output Voltage
(Over all operating input voltage, resistive load, and
temperature conditions at steady state until end of life.)
A Vo 4.85 5.15 Vdc
Output Regulation:
Line (VI = VI, min to VI, max)
Load (IO = IO, min to IO, max)
Temperature (TA = TA, min to TA, max)
A—
0.05
0.05
15
0.2
0.2
50
%, VO, set
%, VO, set
mV
Output Ripple and Noise
RMS (5 Hz to 20 MHz bandwidth)
Peak-to-peak (5 Hz to 20 MHz bandwidth) A—
30
100 mVrms
mVp-p
External Load Capacitance 10,000 µF
Output Current
(Vo =90% of VO, nom.) AIO0.025Adc
Output Current-limit Inception
(VO = 90% of VO, set) A IO, lim 30 Adc
Output Short-circuit Current (Average)VO = 0.25 V Latched off
Efficiency
(VI = VIN, nom; IO = IO, max), TA = 25 °C η 91.5 %
Switching Frequency All fSW 300 kHz
Dynamic Response
(DIO/Dt = 1 A/10 µs, VI = 48 V, TA = 25 ° C); tested
with a 220 µF aluminium and a 1.0 µf ceramic
capacitor across the load.):
Load Change from
IO = 50% to 75% of IO, max:
Peak Deviation
Settling Time
(VO < 10% of peak deviation)
Load Change from IO = 50% to 25%
of IO, max :
Peak Deviation
Settling Time
(VO < 10% of peak deviation)
250
200
250
200
mV
µs
mV
µs
Parameter Symbol Min Typ Max Unit
Isolation Capacitance Ciso 5600 PF
Isolation Resistance Riso 10 MΩ
Parameter Min Typ Max Unit
Calculated MTBF (Io = 80% of Io, max Ta = 40 °C), Issue 1, M1,C1 1,219,777 Hours
Weight 37(1.31) g (oz.)
Lineage Power 22
Data Sheet
June 15, 200936 Vdc - 75 Vdc Input, 1.0 to 12 Vdc Output; 10 A to 40 A
QRW010/025/035/040 Series Power Modules; dc-dc Converters
Feature Specifications
Unless otherwise indicated, specifications apply over all operating input voltage, resistive load, and temperature conditions.
See Feature Descriptions for additional information .
* A Minimum OFF Period of 1 sec is recommended.
Parameter Symbol Min Typ Max Unit
Remote On/Off Signal Interface*
(VI = 0 V to 75 V; open collector or equivalent compatible; signal
referenced to VI(–) terminal; see Figure 52
and Feature Descriptions.):
Preferred Logic:
Logic Low—Module On
Logic High—Module Off
Optional Logic:
Logic Low—Module Off
Logic High—Module On
Logic Low:
At Ion/off = 1.0 mA
At Von/off = 0.0 V
Logic High:
At Ion/off = 0.0 µA
Leakage Current
Turn-on Time; see Typical Start-up Curve(IO = IO max;
Vo within ±1% of steady state)
Von/off
Ion/off
Von/off
Ion/off
0
1
1.2
1.0
15
50
4
V
mA
V
µA
ms
Output Voltage Adjustment
(See Feature Descriptions):
Output Voltage Remote-sense Range
Output Voltage Set-point Adjustment Range (trim)
80
0.5
110 V
%V0,nom
Output Overvoltage Protection VO, ovsd 5.6 6.8 V
Overtemperaute Protection (IO = IO, max) Tref1 127 °C
Lineage Power 23
Data Sheet
June 15, 200936 Vdc - 75 Vdc Input, 1.0 to 12 Vdc Output; 10 A to 40 A
QRW010/025/035/040 Series Power Modules; dc-dc Converters
Characteristic Curves
The following figures provide typical characteristics curves for the QRW025A0A (VO = 5.0V) module at room temperature (TA =
25 °C)
Figure 37. Input Voltage and Current Characteristics.
Figure 38. Converte r Efficiency vs. Output Current.
Figure 39. Output Ripple Voltage (IO = IO, max).
Tested with a 220µF aluminium and a 1.0µF ceramic capacitor
across the load.
Figure 40. Transient Response to Step Decrease in
Load from 50% to 25% of Full Load
(VI = 48 Vdc).
Figure 41. Transient Response to Step Increase in Load
from 50% to 75% of Full Load
(VI = 48 Vdc).
Tested with a 10µF aluminium and a 1.0µF tant alum capacitor across
the load.
Figure 42. Start-up from Remote On/Off (IO = IO, max).
25 30 35 40 45 50 55 60 65 70 7
4
3.5
3
2.5
2
1.5
1
0.5
0
I
I
IO = 25 A
IO = 12.5 A
IO = 0.5 A
0 5 10 15 20 2
5
95
90
85
80
75
70
OUTPUT CURRENT, I
O
(A)
EFFICENCY, η (%)
VI = 36 V
VI = 48 V
VI = 75 V
TIME, t (1 µs/div)
OUTPUT V OLTAGE, V
O
(V)
(50 mV/div)
VI = 36 V
VI = 48 V
VI = 75 V
TIME, t (100 µs/div)
OUTPUT CURRENT, I
O
(A)
( 5 A/div)
OUTPUT V OLTAGE, V
O
(V)
(200 mV/div)
TIME, t (100 µs/div)
OUTPUT CURRENT, I
O
(A)
( 5 A/div)
OUTPUT V OLTAGE, V
O
(V)
(200 mV/div)
TIME, t (1 ms/div)
REMOTE ON/OFF,
V
ON/OFF
(V) OUTPUT V OLTAGE
, (
(2 V/div)
Lineage Power 24
Data Sheet
June 15, 200936 Vdc - 75 Vdc Input, 1.0 to 12 Vdc Output; 10 A to 40 A
QRW010/025/035/040 Series Power Modules; dc-dc Converters
Electrical Specifications (continued)
Output Specifications for the QRW010A0B (Vo = 12.0 Vdc)
Isolation Specifications
General Specifications
Parameter Device Symbol Min Typ Max Unit
Output Voltage Set Point
(VI = 48 Vdc; IO = IO, min to IO, max, TA = 25 °C) B Vo 11.76 12 12.24 Vdc
Output Voltage
(Over all operating input voltage, resistive load, and
temperature conditions at steady state until end of life.)
B Vo 11.64 12.36 Vdc
Output Regulation:
Line (VI = VI, min to VI, max)
Load (IO = IO, min to IO, max)
Temperature (TA = TA, min to TA, max)
B—
0.05
0.05
15
0.2
0.2
50
%, VO, set
%, VO, set
mV
Output Ripple and Noise
RMS (5 Hz to 20 MHz bandwidth)
Peak-to-peak (5 Hz to 20 MHz bandwidth) B—
30
100 mVrms
mVp-p
External Load Capacitance 2200 µF
Output Current
(Vo =90% of VO, nom.) BIO0.010Adc
Output Current-limit Inception
(VO = 90% of VO, set) B IO, lim 12 Adc
Output Short-circuit Current (Average)VO = 0.25 V Latched off
Efficiency
(VI = VIN, nom; IO = IO, max), TA = 25 °C η 92.5 %
Switching Frequency All fSW 300 kHz
Dynamic Response
(DIO/Dt = 1 A/10 µs, VI = 48 V, TA = 25 ° C); tested
with a 220 µF aluminium and a 1.0 µf ceramic
capacitor across the load.):
Load Change from
IO = 50% to 75% of IO, max:
Peak Deviation
Settling Time
(VO < 10% of peak deviation)
Load Change from IO = 50% to 25%
of IO, max :
Peak Deviation
Settling Time
(VO < 10% of peak deviation)
360
300
360
300
mV
µs
mV
µs
Parameter Symbol Min Typ Max Unit
Isolation Capacitance Ciso 5600 PF
Isolation Resistance Riso 10 MΩ
Parameter Min Typ Max Unit
Calculated MTBF (Io = 80% of Io, max, Ta = 40 °C), Issue 1, M1,C1 1,227,000 Hours
Weight 37(1.31) g (oz.)
Lineage Power 25
Data Sheet
June 15, 200936 Vdc - 75 Vdc Input, 1.0 to 12 Vdc Output; 10 A to 40 A
QRW010/025/035/040 Series Power Modules; dc-dc Converters
Feature Specifications
Unless otherwise indicate d, specifications apply over all operating input voltage, resistive load, and temperature conditions.
See Feature Descriptions for additional information.
* A Minimum OFF Period of 1 sec is recommended.
Parameter Symbol Min Typ Max Unit
Remote On/Off Signal Interface*
(VI = 0 V to 75 V; open collector or equivalent compatible; signal
referenced to VI(–) terminal; see Figure 52
and Feature Descriptions.):
Preferred Logic:
Logic Low—Module On
Logic High—Module Off
Optional Logic:
Logic Low—Module Off
Logic High—Module On
Logic Low:
At Ion/off = 1.0 mA
At Von/off = 0.0 V
Logic High:
At Ion/off = 0.0 µA
Leakage Current
Turn-on Time; see Typical Start-up Curve(IO = IO max;
Vo within ±1% of steady state)
Von/off
Ion/off
Von/off
Ion/off
0
2
1.2
1.0
15
50
4
V
mA
V
µA
ms
Output Voltage Adjustmen t
(See Feature Descriptions):
Output Voltage Remote-sense Range
Output Voltage Set-point Adjustment Range (tr im)
80
0.5
110 V
%V0,nom
Output Overvoltage Protection VO, ovsd 13.5 15 16.5 V
Overtemperaute Protection (IO = IO, max) Tref1 127 °C
Lineage Power 26
Data Sheet
June 15, 200936 Vdc - 75 Vdc Input, 1.0 to 12 Vdc Output; 10 A to 40 A
QRW010/025/035/040 Series Power Modules; dc-dc Converters
Characteristic Curves
The following figures provide typical characteristics curves for the QRW010A0B (VO = 12.0V) module at room temperature (TA
= 25 °C)
Figure 43. Input Voltage and Current Characteristics.
Figure 44. Converte r Efficiency vs. Output Current.
Figure 45. Output Ripple Voltage (IO = IO, max).
Tested with a 220µF aluminium and a 1.0µF ceramic capacitor
across the load.
Figure 46. Transient Response to Step Decrease in
Load from 50% to 25% of Full Load
(VI = 48 Vdc).
Figure 47. Transient Response to Step Increase in Load
from 50% to 75% of Full Load
(VI = 48 Vdc).
Tested with a 10µF aluminium and a 1.0µF tant alum capacitor across
the load.
Figure 48. Start-up from Remote On/Off (IO = IO, max).
0
0.5
1
1.5
2
2.5
3
3.5
4
25 35 45 55 65 7
5
INPUT VOLTAGE, V
I
(V)
INPUT CURRENT, I
I
(A)
IO = 10 A
IO = 5 A
IO = 0 A
EFFICIENCY, (%)
η
OUTPUT CURRENT, Io (A)
TIME, t (1 µs/div)
OUTPUT V OLTAGE, V
O
(V)
(50 mV/div)
V
I
= 36 V
V
I
= 48 V
V
I
= 75 V
TIME, t (100 µs/div)
OUTPUT V OLTAGE, V
O
(
V)
(200 mV/div)
O
UTPUT CURRENT, I
O
(A)
(2 A/div)
TIME, t (100 µs/div)
OUTPUT V OLTAGE, V
O
(V)
(200 mV/div)
O
UTPUT CURRENT, I
O
(A)
(2 A/div)
2
Lineage Power 27
Data Sheet
June 15, 200936 Vdc - 75 Vdc Input, 1.0 to 12 Vdc Output; 10 A to 40 A
QRW010/025/035/040 Series Power Modules; dc-dc Converters
Test Configurations
Note:Measure input reflected-ripple current with a simulated
source inductance (LTEST) of 12 µH. Capacitor CS off-
sets possible battery impedance. Measure current as
shown above.
Figure 49. Input Reflected-Ripple Test Setup.
Note:Use a 1.0 µF ceramic capacitor and a 10 µF aluminum
or
tantalum cap acitor. Scope measurement should be
made using a BNC socket. Position the load between
51 mm and 76 mm (2 in. and 3 in .) fro m the module.
Figure 50. Peak-to-Peak Output Noise Measurement Test
Setup.
Note:All measurements are taken at the module terminals.
When socketing, place Kelvin connections at modul e
terminals to avoi d measuremen t errors due to socket
contact resistance.
Figure 51. Outpu t Voltage and Efficiency Measurement.
Design Considerations
Input Source Impedance
The power module should be connected to a low
ac-impedance input source. Highly inductive source imped-
ances can affect the stability of the power
module. For the test configuration in 49,
a 33 µF electrolytic capacitor (ESR < 0.7 W at 100 kHz)
mounted close to the power module helps ensure
stability of the unit. For other highly inductive source imped-
ances, consult the factory for further application guideli nes.
Output Capacitance
High output current transient rate of change (high di/dt) loads
may require high values of output capacitance to supply the
instantaneous energy requirement to the load. Tp minimize
the output voltage transient drop
during this transient, low E.S.R. (equivalent series resistance)
capacitors may be required, since a high E.S.R. will produce
a correspondingly higher voltage drop during the current tran-
sient.
Output capacitance and load impedance interact with the
power module’s output volt age regulation control system and
may produce an ’unstable’ output condition for the required
values of capacitance and E.S.R.. Minimum and maximum
values of output capacitance and of the capacitor’s associ-
ated E.S.R. may be dictated, depending on the module’s con-
trol system.
The process of determining the acceptable values
of capacitance and E.S.R. is complex and is
load-dependant. Lineage provides Web-based tools to assist
the power module end-user in appraising and adjusting the
effect of various load conditions and output capacitances
on specific power modules for various load conditions.
Safety Considerations
For safety-agency approval of the system in which the power
module is used, the power module must be installed in com-
pliance with the spacing and separation requirements of the
end-use safety agency standard, i.e., UL60950, CSA C22.2
No. 60950-00, and VDE 0805:2001-12 (IEC60950, 3rd Ed).
These converters have been evaluated to the spacing
requirements for Basic Insulation, per the above safety stan-
dards and 1500 Vdc is applied from VI to VO to 100% of out-
going production.
For end products connected to –48 Vdc, or –60 Vdc nomianl
DC MAINS (i.e. central offic e dc battery plant), no further fault
testing is required.
Note:–60 V dc nominal bettery plants are not available in the
U.S. or Canada.
For all input voltages, other than DC MAINS, where the input
voltage is less than 60 Vdc, if the input meets all of the
requirements for SELV, then:
V
I
(+)
V
I
(–)
CURRENT
PROBE
TO
OSCILLOSCOPE
L
TEST
12
μ
H
BATTERY C
S
220
μ
F
ESR < 0.1
Ω
@ 20 ºC 100 kHz
COPPER STRIPS
1.0
μ
F10
μ
FSCOPE
V
O
(+)
RESISTIVE
V
O
(-)
LOAD
CONTACT AND
SUPPLY I
I
CONTACT
V
I
(+)
V
I
(–)
V
O
(+) DISTRIBUTION LOSSES
RESISTANCE
I
O
LOAD
V
O
(–)
SENSE(–)
SENSE(+)
ηVO(+) VO(-)[]IO
VI(+) VI(-)[]II
----------------------------------------------
⎝⎠
⎛⎞
100 %×=
Lineage Power 28
Data Sheet
June 15, 200936 Vdc - 75 Vdc Input, 1.0 to 12 Vdc Output; 10 A to 40 A
QRW010/025/035/040 Series Power Modules; dc-dc Converters
n
The output may be considered SELV. Output voltages will
remain withing SELV limits even with internally-generated
non-SELV voltages. Single component failure and fault
tests were performed in the power converters.
n
One pole of the input and one pole of the output are to be
grounded, or both circuits are to be kept floating, to main-
tain the output voltage to ground voltage within ELV or
SELV limits.
For all in put sources , other than DC MAINS, where the input
voltage is between 60 and 75 Vdc (Classified as TNV-2 in
Europe), the following must be adhered to, if the converter’s
output is to be evaluated for SELV:
n
The input source is to be provided with reinforced insula-
tion from any hazardous voltage, including the AC mains.
n
One VI pin and one VO pin are to be reliably earthed, or
both the input and output pins are to be kept floating.
n
Another SELV reliability test is conducted on the whole
system, as required by the safety agencies, on the combi-
nation of supply source and the subject module to verify
that under a single fault, hazardous voltages do not
appear at the module’s output.
The power module has ELV (extra-low voltage) outputs
when all inputs are ELV.
All flammable materials used in the manufacturing of these
modules are rated 94V-0, and UL60950A.2 for reduced
thicknesses. The input to these units is to be provided with a
maximum 10A normal-blow fuse in the ungrounded lead.
Lineage Power 29
Data Sheet
June 15, 200936 Vdc - 75 Vdc Input, 1.0 to 12 Vdc Output; 10 A to 40 A
QRW010/025/035/040 Series Power Modules; dc-dc Converters
Feature Descriptions
Overcurrent Protection
To provide pr otection in a fault output overload condition, th e
module is equipped with internal current-limiting circuitry and
can endure current limit for few seconds. If overcurrent per-
sists for few seconds, the module will shut down and remain
latch-off.
The overcurrent latch is reset by either cycling the input
power or by toggling the on/off pin for one second. If the out-
put overload condition still exists when the module restarts, it
will shut down again. This operation will continue indefinitely
until the overcurrent condition is corrected.
An auto-restart option is also available.
Remote On/Off
T wo remote on/off options are available. Positive logic remote
on/off turns the module on during a logic-high voltage on the
ON/OFF pin, and off during a logic low. Negative logic remote
on/off turns the module off during a logic high and on during a
logic low. Negative logic, device code suffix "1," is the factory-
preferred configuration.
To turn the power module on and off, the user must supply a
switch to control the voltage between the on/off terminal and
the VI(-) terminal (Von/off). The switch can be an open collec-
tor or equivalent (see Figure 10). A logic low is Von/off = 0 V
to I.2 V. The maximum Ion/off during a logic low is 1 mA. The
switch should maintain a logic-low voltage while sinking 1
mA.
During a logic high, the maximum Von/off generated by the
power module is 15 V. The maximum allowable leakage cur-
rent of the switch at Von/off = 15V is 50 µA.
If not using the remote on/off feature, do one of the following
to turn the unit on
For negative logic, short ON/OFF pin to VI(-).
For positive logic: leave ON/OFF pin open.
Figure 52. Remote On/Off Implementation.
Remote Sense
Remote sense minimizes the effects of distribution losses by
regulating the voltage at the remote-sense connections. The
voltage between the remote-sense pins and the output termi-
nals must not exceed the output voltage sense range given in
the Feature Specifications table i.e.:
[Vo(+) – Vo(-)] – [SENSE(+) – SENSE(-)] £ 10% of Vo, rated
The voltage between the Vo(+) and Vo(-) terminals must not
exceed the minimum output overvoltage shutdown value indi-
cated in the Feature Specifications table. This limit incl udes
any increase in voltage due to remote-sense compensation
and output voltage set-point adjustment (trim). See Figure 53.
If not using the remote-sense feature to regulate the output at
the point of load, then connect SENSE(+) to Vo(+) and
SENSE(-) to Vo(-) at the module.
Although the output voltage can be increased by both the
remote sense and by tine trim, the maximum increase for the
output voltage is not the sum of both. The maximum increase
is the larger of either the remote sense or the trim.
The amount of power delivered by the module is define d as
the voltage at the output terminals multiplied by the output
current. When using remote sense and trim: the output volt-
age of the module can be increased, which at the same out-
put current would increase the power output of the module.
Care should be taken to ensure that the maximum output
power of the module remains at or below the maximum rated
power.
Figure 53. Effective Circuit Configuration for
Single-Mod ule Remote-Sen se Operation
Output Voltage.
Output Overvoltage Protection
The output overvoltage protection consists of circuitry that
monitors the voltage on the output terminals. If the voltage on
the output terminals exceeds the over
voltage protection threshold, then the module will
shutdown and latch off. The overvoltage latch is reset by
either cycling the input power for one second or by toggling
the on/off signal for one second.
The protection mechanism is such that the unit can continue
in this condition until the fault is cleared.
Overtempera tur e Prot ec ti o n
These modu l e s fe at ure an overtemperature pr otection circui t
to safeguard against thermal damage. The circuit shuts down
and latches off the module when the maximum device refer-
ence temperature is exceeded. The module can be restarted
by cycling the dc input power for at least one second or by
toggling the remote on/off signal for at least one second.
SENSE(+)
V
O
(+)
SENSE(–)
V
O
(–)
V
I
(–)
+
I
on/off
ON/OFF
V
I
(+)
LOAD
V
on/off
SENSE(+)
SENSE(–)
VI(+)
VI(–)
IOLOAD
CONTACT AND
SUPPLY II
CONTACT
VO(+)
VO(–)
DISTRIBUTION LOSSESRESISTANCE
Lineage Power 30
Data Sheet
June 15, 200936 Vdc - 75 Vdc Input, 1.0 to 12 Vdc Output; 10 A to 40 A
QRW010/025/035/040 Series Power Modules; dc-dc Converters
Feature Descriptions (Continued)
Output Voltage Set-Point Adjustment (Trim)
T rimming allows the user to increase or decrease the output
voltage set point of a module. This is accomplished by con-
necting an external resistor between the TRIM pin and either
the SENSE(+) or SENSE(-) pins. The trim resistor should be
positioned close to the module
.
If not using the trim feature, leave the TRIM pin open.
With an external resistor between the TRIM and SENSE(-)
pins (Radj-down), the output voltage set point (Vo,adj)
decreases (see Figure 54). The following equation deter-
mines the required external-resistor value to obtain a per-
centage output voltage change of D%.
For Output Voltage: 1.0V - 12V
With an external resistor connected between the TRIM and
SENSE(+) pins (Radj-up), the output voltage set point
(Vo,adj) increases (see Figure 55).
The following equ ation determines the required external-
resistor value to obtain a percentage output voltage change
of D%
For Output Voltage: 1.5V - 12V
For Output Voltage: 1.2V, 1.0V
The voltage between the Vo(+) and Vo(-) terminals must not
exceed the minimum output overvoltage shut-down value
indicated in the Feature Specifications table. This limit
includes any increase in voltage due to remote-sense com-
pensation and output voltage set-point adjustment (trim).
See Figure 53.
Although the output voltage can be increased by both the
remote sense and by the trim, the maximum increase for the
output voltage is not the sum of both. The maximum
increase is the larger of either the remote sense or the trim.
The amount of power delivered by the module is defined as
the voltage at the output terminals multipl ied by the output
current. When using remote sense and trim, the output volt-
age of the module can be increa sed, which at the same out-
put current would increase the power output of the module.
Care should be taken to ensure that the maximum output
power of the module remains at or below the maximum rated
power.
Figure 54. Circuit Configuration to Decrease Output
Voltage.
Figure 55. Circuit Configuration to Increase Output
Voltage.
VI
(+)
VI(–)
ON/OFF
CASE
VO(+)
VO(–)
SENSE(+)
TRIM
SENSE(–) Radj-down RLOAD
VI
(+)
VI(–)
ON/OFF
CASE
VO(+)
VO(–)
SENSE(+)
TRIM
SENSE(–)
Radj-up RLOAD
Lineage Power 31
Data Sheet
June 15, 200936 Vdc - 75 Vdc Input, 1.0 to 12 Vdc Output; 10 A to 40 A
QRW010/025/035/040 Series Power Modules; dc-dc Converters
Thermal Considerations
The power modules operate in a variety of thermal environ-
ments; however, sufficient cooling should be provided to help
ensure reliable operation of the unit. Heat-dissipating compo-
nents are mounted on the top side of the module. Heat is
removed by conduction, convection and radiation to the sur-
rounding environment. Proper cooling can be verified by
measuring the temperature of selected components on the
topside of the power module (See 56). Peak temperature
(Tref) can occur at any of these positions indicated in Figure
50.
Note:Top view, pin locations are for reference onl y.
Figure 56. Temperature Measurement Location.
The temperature at any one of these locations should not
exceed per 1 to ensure reliable operation of the power mod-
ule. The output power of the mo dule should not exceed the
rated power for the module as listed in the Ordering Informa-
tion table.
Although the maximum Tref temperature of the power mod-
ules is per 1, you can limit these temp eratures to a lower
value for extremely high reliability.
Table 1. Device Temperature
Heat Transfer Without Heat Sinks
Increasing airflow over the module enhances the heat trans-
fer via convection. Figures 57 through 64 shows the maxi-
mum current that can be delivered by the corresponding
module without exceeding the maximum case temperature
versus local ambient temperature (TA) for natural convection
through 2 m/s (400 ft./min.).
Note that the natural convection condition was measured at
0.05 m/s to 0.1 m/s (10ft./min. to 20 ft./min.); however, sys-
tems in which these power modules may be used typically
generate natural convection airflow rates of 0.3 m/s (60 ft./
min.) due to other heat dissipating component s in the system.
The use of output power derating curve is shown in the fol-
lowing example.
What is the minimum airflow necessary for a QRW035A0F
operating at VI = 48 V, an output current of 23A, and a maxi-
mum ambient temperature of 70 °C.
Solution
Given: VI = 48V
Io = 23A
TA = 70 °C
Determine airflow (v) (Use Figure 62):
v = 1m/sec. (200ft./min.)
Figure 57. Output Power Derating for QRW040A0S1R0
(Vo = 1.0V) in Transve rse Orientation with No
Baseplate; Airflow direction from VIN (+) to
VIN (–); VIN = 48V.
Figure 58. Output Power Dera ting for QRW040A0P (V o =
1.2V) in Transve rse Orientation with No
Baseplate; Airflow direction from VIN (+) to
VIN (–); VIN = 48V.
Output Voltage Device Temperature (°C)
1.0V Tref1 116
1.2V Tref1 119
1.5V Tref1 118
1.8V Tref1 117
2.5V Tref1 118
3.3V Tref1
Tref2
Tref3
114
112
130
5V Tref1 113
12V Tref1 118
OUTPUT
INPUT
Airflow
Thermocouple
Location Tref 3Thermocouple
Location Tref 2
Thermocouple
Location Tref 1
LOCAL AMBIENT TEMPERATURE, T (°C)
A
OUTPUT CURRENT , I (A)
O
40
35
30
25
20
15
10
5
020 30 40 50 60 70 80 90
LOCAL AMBIENT TEMPERATURE, T (°C)
A
OUTPUT CURRENT , I (A)
O
Lineage Power 32
Data Sheet
June 15, 200936 Vdc - 75 Vdc Input, 1.0 to 12 Vdc Output; 10 A to 40 A
QRW010/025/035/040 Series Power Modules; dc-dc Converters
Thermal Considerations (continued)
Figure 59. Output Power Derating for QRW040A0M (Vo
= 1.5V) in Transve rse Orientation with No
Baseplate; Airflow direction from VIN (+) to
VIN (–); VIN = 48V.
Figure 60. Output Power Derating for QRW040A0Y (Vo
= 1.8V) in Transve rse Orientation with No
Baseplate; Airflow direction from VIN (+) to
VIN (–); VIN = 48V.
Figure 61. Output Power Derating for QRW0350G (Vo =
2.5) in Transve rse Orientation with No
Baseplate; Airflow direction from VIN (+) to
VIN (–); VIN = 48V.
Figure 62. Output Power Derating for QRW035A0F (Vo
= 3.3V) in Transverse Orientation with No
Baseplate; Airflow direction from VIN (+) to
VIN (–); VIN = 48V.
Figure 63. Output Power Derating for QRW025A0A (Vo
= 5V) in Transverse Orientation with No
Baseplate; Airflow direction from VIN (+) to
VIN (–); VIN = 48V.
Figure 64. Output Power Derating for QRW010A0B (Vo
= 12V) in Tra nsv erse Orientation with No
Baseplate; Airflow direction from VIN (+) to
VIN (–); VIN = 48V.
40
35
30
25
20
15
10
5
020 30 40 50 60 70 80 90
LOCAL AMBIENT TEMPERA TURE, T
(
°C
)
A
OUTPUT CURRENT, I (A)
O
40
35
30
25
20
15
10
5
020 30 40 50 60 70 80 90
LOCAL AMBIENT TEMPERA TURE
,
T
(
°C
)
A
O
U
T
P
U
T
C
U
R
R
EN
T
, I (A)
O
40
35
30
25
20
15
10
5
020 30 40 50 60 70 80 90
LOCAL AMBIENT TEMPERA TURE, T (°C)
A
OUTPUT CURRENT, I (A)
O
Data Sheet
June 15, 2009 QRW010/025/035/ 040 Series Power Modules; dc-dc Converter s
36 Vdc – 75 Vdc Input; 1.0 to 12 Vdc Output; 10 A to 40
A
Lineage Power 33
Outline Diagram
Dimen sion s are in millimeters and [inc he s].
Tolerances: x.x mm ± 0.5 mm [x.xx in. ± 0.02 in.] (Unless otherwise indicated)
x.xx mm ± 0.25 mm [x.xx x i n ± 0.010 in.]
*Top side labe l i nclud e s Lineag e Pow er name , prod u ct des ign at ion, and data cod e.
** Standard pin tail length. Optional pin tail lengths shown in Table 2 Device Options.
Top View*
Side V i ew
Bottom View
†Option Feature, pin is not present unless one these options specified.
Data Sheet
June 15, 2009 QRW010/025/035/ 040 Series Power Modules; dc-dc Converter s
36 Vdc – 75 Vdc Input; 1.0 to 12 Vdc Output; 10 A to 40
A
LINEAGE POWER 34
Recommended Hole Pattern
Dimen sion s are in millim et e r s and (in che s).
Lineage Power 35
Data Sheet
June 15, 200936 Vdc - 75 Vdc Input, 1.0 to 12 Vdc Output; 10 A to 40 A
QRW010/025/035/040 Series Power Modules; dc-dc Converters
Through-Hole Lead-Free Soldering Infor-
mation
The RoHS-compliant through-hole products use the SAC
(Sn/Ag/Cu) Pb-free solder and RoHS-compliant components.
They are designed to be processed through single or dual
wave soldering machines. The pins have an RoHS-compli-
ant finish that is compatible with both Pb and Pb-free wave
soldering processes. A maximum preheat rate of 3°C/s is
suggested. The wave preheat process sh ould be such that
the temperature of the power module boa rd is kept below
210°C. For Pb solder, the recommended pot temperature is
260°C, while the Pb-free solder pot is 270°C max. Not all
RoHS-compliant through-hole pr oducts can be processed
with paste-through-hole Pb or Pb-free reflow process. If addi-
tional information is needed, ple ase consult with your
Lineage Power System representative for more details.
Post Solder Cleaning and Drying Considerations
Post solder cleaning is usually the final circuit-bo ard
assembly process prior to electrical board testing. The result
of inadequate cleaning and drying can affect both the
reliability of a power module and the testability of the finished
circuit-board assembly. For guidance on appropriate
soldering, cleaning and drying procedures, refer to Lineage
Power Board Mounted Power Modules: Soldering and
Cleaning Application Note (AP01-056EPS).
Document No:DS03-113 ver. 4.3
PDF Name:qrw-series_ds.pdf
Data Sheet
June 15, 200936 Vdc - 75 Vdc Input, 1.0 to 12 Vdc Output; 10 A to 40 A
QRW010/025/035/040 Series Power Modules; dc-dc Converters
Note: Legacy device codes may contain a -B option suffix
to indicate 100% factory Hi-Pot tested to the isolation volt-
age specified in the Absolute Maximum Ratings table. The
100% Hi-Pot test is now applied to all device codes, with or
without the -B option suffix. Existing comcodes for devices
with the -B suffix are still valid; however, no new comcodes
for devices containing the -B suffix will be created.
World Wide He a dquarters
Lin eage Po w er Co rp oratio n
3000 Skyline Drive, Mesquite, TX 75149, USA
+1-800-526-7819
(Outs ide U .S.A.: +1-97 2-2 84 -2626)
www.line ag epower.com
e-mail: t ec hsu pport1@lineagepower.com
A sia-Pacific Headquart ers
Tel: +65 6416 4283
Europe, Middle-East and Africa He adquarters
Tel: +49 8 9 6089 286
India Head qu arters
Tel: +91 80 28411633
Lineage Power reserves the right to m ake changes to the produc t(s) or inform ation contained herein without notice. No liability is ass um ed as a res ult of their use or
applic ation. No rights under any patent acc om pany the sale of any s uc h pr oduct(s ) or information.
© 2008 Lineage Power Corpor ation, (M esquite, Texas ) All International Rights Res er ved.
Ordering Information
For assistance in ordering, please contact your Lineage Power Account Manager or Field Application Engi-
neer for pricing and availability.
Optional features can be ordered using the suffixes shown in table belo w. The suffixes follow the last letter of the device code
and are placed in descending order. For example, the device codes for a QW010/015/0201 module with the following options
are shown below:
Auto-restart after over current shutdown QRW035A0F41
Input Voltage Output
Voltage Output
Current Efficiency Connector Type Device Code Comcodes
48V (36-75Vdc) 1.0V 40A 83% Through hole QRW040A0S1R01 108967712
48V (36-75Vdc) 1.2V 40A 85% Through hole QRW040A0P1 108965542
48V (36-75Vdc) 1.5V 40A 86% Through hole QRW040A0M1 1089655 34
48V (36-75Vdc) 1.8V 40A 87% Through hole QRW040A0Y1 108965559
48V (36-75Vdc) 2.5V 35A 90% Through hole QRW035A0G1 108965526
48V (36-75Vdc) 3.3V 35A 91% Through hole QRW035A0F 108965989
48V (36-75Vdc) 3.3V 35A 91% Through hole QRW035A0F1 108965518
48V (36-75Vdc) 3.3V 35A 91% Through hole QRW035A0F1-H 108967720
48V (36-75Vdc) 3.3V 35A 91% Through hole QRW035A0F71-H 108967829
48V (36-75Vdc) 5V 25A 92% Through hole QRW025A0A1 108965500
48V (36-75Vdc) 5V 25A 92% Through hole QRW025A0A641 108985672
48V (36-75Vdc) 12V 10A 91% Through ho le QRW010A0B1 108 967167
48V (36-75Vdc) 1.5V 40A 86% Through hole QRW040A0M1Z CC109107521
48V (36-75Vdc) 2.5V 35A 90% Through hole QRW035A0G1Z CC109107505
48V (36-75Vdc) 3.3V 35A 91% Through hole QRW035A0F1Z 108995230
48V (36-75Vdc) 5V 25A 92% Through hole QRW025A0A1Z CC109101474
48V (36-75Vdc) 12V 10A 91% Through hole QRW010A0B1Z CC109102992
Option Suffix
Negative Logic remote on/off 1
Auto-restart after fault shutdown 4
Base plate version for Heat Sink attachment –H
Pin Length: 3.68 mm ± 0.25 mm
(0.145 in. ± 0.010 in) 6
Case Pin (Only available with –H option) 7
Pin Length: 2.79 mm ± 0.25 mm
(0.110 in. ± 0.010 in) 8
RoHS compliant –Z
Mouser Electronics
Authorized Distributor
Click to View Pricing, Inventory, Delivery & Lifecycle Information:
GE (General Electric):
QRW010A0B1Z QRW025A0A1Z QRW035A0F1Z QRW025A0A1-HZ QRW025A0A41Z QRW025A0A741-HZ
QRW035A0F41Z QRW035A0F741-HZ QRW035A0G1-HZ QRW010A0B41-HZ QRW010A0B641Z QRW010A0B841Z
QRW025A0A641Z QRW025A0A6Z QRW035A0F641Z QRW040A0Y641-BHZ QRW025A0A641-BZ QRW035A0F1-