1) Typical test pulse: rise time 10 ns, time to half value 1500 ns, charge voltage min. 50 kV, source impedance 90 Ω
General technical data
Rated voltage VR,AC 100 V
Rated voltage VR,DC 100 V
Rated frequency fRPass bandwidth at ZL
Rated current IRSee characteristics TA=40°C
Line impedance ZLSee characteristics
Test voltage Vtest 250 VDC, 2 s Line/line
250 VDC, 2 s Line/case
Maximum DC resistance Rmax See characteristics Per line
Permissible ambient temperature TA25/+40 °C
Climatic category
(EN 60068-1)
25/085/56 25 °C/+85 °C/56 days damp
heat test
Weight 560 g 2-line filters
4.5 kg 20-line filters
Mechanical version C Upright for 2- and 20-line filters
F Flat for 2-line filters
Filters with EMP protection:
Nominal DC spark-over voltage VsdcN <500 V Per line
Surge response voltage <800 V At 1 kV/µs
<800 V At 1 kV/ns
Nominal surge current (8/20 µs) 5/10 kA
Suppression condition I ≤IR
Maximum voltage on filter output for filters with EMP protection
Series B84312 ...0020+1**
...0090+1**
...0030+1**
...0100+1**
...0040+1** ...0050+1** ...0060+1**
Pulse shape in symmetrical circuit
dv/dt = 0.1 kV/µs2 V 360 V 8 V 3 V 12 V
dv/dt = 1 kV/µs1 V 60 V 3 V 2 V 9 V
dv/dt = 1 kV/ns1) 0.5 V 2 V 0.5 V 0.5 V 1.2 V
Nominal surge current (8/20 µs) 5 V 290 V 12 V 10 V 12 V
Pulse shape in unsymmetrical circuit
dv/dt = 0.1 kV/µs50 V 700 V 250 V 120 V 280 V
dv/dt = 1 kV/µs35 V 130 V 60 V 25 V 30 V
dv/dt = 1 kV/ns1) 1 V 5 V 3 V 1 V 1 V
Nominal surge current (8/20 µs) 20 V 200 V 110 V 25 V 50 V
Filters for communication lines B84312
Analog systems and control lines
5