TDS LOCTITE®246™, January-2011
GENERAL INFORMATION
This product is not recommended for use in pure oxygen
and/or oxygen rich systems and should not be selected as
a sealant for chlorine or other strong oxidizing materials.
For safe handling information on this product, consult the
Safety Data Sheet (SDS).
Where aqueous washing systems are used to clean the
surfaces before bonding, it is important to check for
compatibility of the washing solution with the adhesive. In
some cases these aqueous washes can affect the cure and
performance of the adhesive.
This product is not normally recommended for use on plastics
(particularly thermoplastic materials where stress cracking of
the plastic could result). Users are recommended to confirm
compatibility of the product with such substrates.
Directions for use:
For Assembly
1. For best results, clean all surfaces (external and internal)
with a LOCTITE® cleaning solvent and allow to dry.
2. If the material is an inactive metal or the cure speed is
too slow, spray all threads with Activator 7471™ or
7649™ and allow to dry.
3. Shake the product thoroughly before use.
4. To prevent the product from clogging in the nozzle, do
not allow the tip to touch metal surfaces during
application.
5. For Thru Holes, apply several drops of the product onto
the bolt at the nut engagement area.
6. For Blind Holes, apply several drops of the product
down the internal threads to the bottom of the hole.
7. For Sealing Applications, apply a 360° bead of product
to the leading threads of the male fitting, leaving the first
thread free. Force the material into the threads to
thouroughly fill the voids. For bigger threads and voids,
adjust product amount accordingly and apply a 360°
bead of product on the female threads also.
8. Assemble and tighten as required.
For Disassembly
1. Remove with standard hand tools.
2. In rare instances where hand tools do not work because
of excessive engagement length, apply localized heat to
nut or bolt to approximately 250 °C. Disassemble while
hot.
For Cleanup
1. Cured product can be removed with a combination of
soaking in a Loctite solvent and mechanical abrasion
such as a wire brush.
Loctite Material SpecificationLMS
LMS dated January-16, 1999. Test reports for each batch are
available for the indicated properties. LMS test reports include
selected QC test parameters considered appropriate to
specifications for customer use. Additionally, comprehensive
controls are in place to assure product quality and
consistency. Special customer specification requirements may
be coordinated through Henkel Quality.
Storage
Store product in the unopened container in a dry location.
Storage information may be indicated on the product container
labeling.
Optimal Storage: 8 °C to 21 °C. Storage below 8 °C or
greater than 28 °C can adversely affect product properties.
Material removed from containers may be contaminated during
use. Do not return product to the original container. Henkel
Corporation cannot assume responsibility for product which
has been contaminated or stored under conditions other than
those previously indicated. If additional information is required,
please contact your local Technical Service Center or
Customer Service Representative.
Conversions
(°C x 1.8) + 32 = °F
kV/mm x 25.4 = V/mil
mm / 25.4 = inches
µm / 25.4 = mil
N x 0.225 = lb
N/mm x 5.71 = lb/in
N/mm² x 145 = psi
MPa x 145 = psi
N·m x 8.851 = lb·in
N·m x 0.738 = lb·ft
N·mm x 0.142 = oz·in
mPa·s = cP
Note:
The information provided in this Technical Data Sheet (TDS) including
the recommendations for use and application of the product are based
on our knowledge and experience of the product as at the date of this
TDS. The product can have a variety of different applications as well as
differing application and working conditions in your environment that
are beyond our control. Henkel is, therefore, not liable for the suitability
of our product for the production processes and conditions in respect
of which you use them, as well as the intended applications and
results. We strongly recommend that you carry out your own prior trials
to confirm such suitability of our product.
Any liability in respect of the information in the Technical Data Sheet or
any other written or oral recommendation(s) regarding the concerned
product is excluded, except if otherwise explicitly agreed and except in
relation to death or personal injury caused by our negligence and any
liability under any applicable mandatory product liability law.
In case products are delivered by Henkel Belgium NV, Henkel
Electronic Materials NV, Henkel Nederland BV, Henkel
Technologies France SAS and Henkel France SA please
additionally note the following:
In case Henkel would be nevertheless held liable, on whatever legal
ground, Henkel’s liability will in no event exceed the amount of the
concerned delivery.
In case products are delivered by Henkel Colombiana, S.A.S. the
following disclaimer is applicable:
The information provided in this Technical Data Sheet (TDS) including
the recommendations for use and application of the product are based
on our knowledge and experience of the product as at the date of this
TDS. Henkel is, therefore, not liable for the suitability of our product for
the production processes and conditions in respect of which you use
them, as well as the intended applications and results. We strongly
Henkel Americas
+860.571.5100
Henkel Europe
+49.89.320800.1800
Henkel Asia Pacific
+86.21.2891.8859
For the most direct access to local sales and technical support visit: www.henkel.com/industrial