10 April 2015 Rev.1.0
MOUNTING METHOD
NOTE
Mounting was evaluated with the following profiles in our company, so there was no problem.
However, confirm mounting by the condition of your company beforehand.
The exposure of device under higher temperature many affect to the reliability of the products, it is
recommended to complete soldering in the shortest time possible.
Mounting: Twice soldering is allowed.
INFRARED REFLOW SOLDERING METHOD
Recommended reflow soldering procedure
(NOTE1) Using reflow furnace with short wave infrared radiation heater such as halogen lamp
Regarding temperature profile, please refer to those fo reflow furnace.
In this case the resin surface temperature may become higher than lead terminals due to endothermic ally of black
colored mold resin. Therefore, please avoid from direct exposure to mold resin.
(NOTE2) Other method
Such other methods of soldering as dipping the device into melted solder and vapor phase method (VPS) are not
appropriate because the body of device will be heated rapidly. Therefore, these are not recommended to apply.
(NOTE3) The resin gets softened right after soldering, so, the following care has to be taken
Not to contact the lens surface to anything.
Not to dip the device into water or any solvents.
FLOE SOLDERING METHOD
Flow soldering is not possible.
IRON SOLDERING METHOD
Iron soldering is not possible.
a b c g
e
Room
Temp.
f
d
a : Temperature ramping rate : 1 to 4C/s
b : Pre-heating temperature
time
: 150 to 180C
: 60 to 120s
c : Temperature ramping rate : 1 to 4
C /s
d : 220C or higher time : Shorter than 60s
e : 230C or higher time : Shorter than 40s
f : Peak temperature : Lower than 260C
g : Temperature ramping rate : 1 to 6C /s
The temperature indicates at the surface of mold
package