167 FIBER SENSORS Digital Fiber Sensor FX-410 SERIES Related Information General terms and conditions.............. F-7 Glossary of terms / General precautions..... P.1455~ / P.1458~ Sensor selection guide.................. P.3~ Korea's S-mark.............................. P.1506 LASER SENSORS PHOTOELECTRIC SENSORS Recognition (Excluding FX-412) Conforming to EMC Directive MICRO PHOTOELECTRIC SENSORS AREA SENSORS Certified (Excluding FX-412 and PNP output type) LIGHT CURTAINS / SAFETY COMPONENTS PRESSURE / FLOW SENSORS INDUCTIVE PROXIMITY SENSORS PARTICULAR USE SENSORS SENSOR OPTIONS SIMPLE WIRE-SAVING UNITS WIRE-SAVING SYSTEMS MEASUREMENT SENSORS STATIC ELECTRICITY PREVENTION DEVICES LASER MARKERS PLC HUMAN MACHINE INTERFACES ENERGY CONSUMPTION VISUALIZATION COMPONENTS FA COMPONENTS MACHINE VISION SYSTEMS UV CURING SYSTEMS Selection Guide panasonic.net/id/pidsx/global PNP output type available Light intensity Interference monitor prevention Timer Just "Look" and "Turn", Simple, easy-to-use fiber sensor Incident light intensity and threshold value are displayed simultaneously The incident light intensity and threshold value can be checked at the same time with no operations needed. In addition, no complex mode settings are needed when the values are adjusted. Easy-to-understand operating panel layout The threshold value adjuster and operation mode switch are large and easy to see, and they can be operated with the same sensitivity as general-purpose photoelectric sensors. Functions which are not commonly used can be operated using a non-obtrusive setting switch. Adjustment variations according to the individual have been eliminated Incident light intensity Accurate control of the adjuster threshold values by using numerical values is possible due to the digital display. This allows anybody to perform the same settings. Operation mode switch Threshold value Fibers Setting switch Fiber Amplifiers FX-500 FX-100 Threshold value adjuster FX-300 FX-410 FX-311 FX-301-F7/ FX-301-F Threshold values can be changed smoothly This sensor uses the R.S.S.* adjuster with a compact encoder inside. The sensitivity amount changes depending on the rotation speed of the adjuster, so that adjustment can be carried out speedily. Slower [Turn] Amount of change (digit) 100 10 Faster [Turn] 1 Slower Faster Adjuster rotation speed * * 0 ls 3 ua it eq g 1 di * * Rotation Speed Sensitivity Adjustment in units of 1 digit is also easy No need for the fine changes in force required for photoelectric sensors. Digital Fiber Sensor FX-410 SERIES New concept FX-412 can be turned by finger! New concept Standard screwdrivers can be used to turn the adjuster as well as precision screwdrivers. In addition, an "endless" mechanism is used which eliminates the possibility of any damage being caused by turning the adjuster too far. The adjuster can be turned directly by finger, without the need for a screwdriver. Large endless adjuster 168 FIBER SENSORS LASER SENSORS PHOTOELECTRIC SENSORS MICRO PHOTOELECTRIC SENSORS AREA SENSORS LIGHT CURTAINS / SAFETY COMPONENTS PRESSURE / FLOW SENSORS INDUCTIVE PROXIMITY SENSORS Everyday-use screwdriver is OK Beam power greatly increased to give strong performance under adverse environments Red LED type The beam power has been greatly increased. This means a longer sensing distance and less trouble from problems such as dust. These sensors have ample performance for workplace needs. 1,550 mm 61.024 in FX-411 Previous models (for U-LG mode) 1,100 mm 43.307 in * For FT-42 thru-beam type fiber Three types are available, with red, blue and green light Different sensors can be selected to suit the application. WIRE-SAVING SYSTEMS MEASUREMENT SENSORS 1.4 times previous models STATIC ELECTRICITY PREVENTION DEVICES LASER MARKERS PLC The red LED type sensors have a "four-chemical emitting element" which maintains stability of light emissions for long-term operation. Furthermore, all models have an "APC (Auto Power Control) circuit" which improves stability at times such as when the power is turned on. These features improve overall stability compared to previous models. Light emitting amount sensing comparison Short-term stability Deviation SENSOR OPTIONS SIMPLE WIRE-SAVING UNITS Improved stability over both long and short terms Red LED type Stable PARTICULAR USE SENSORS Color combinations that can be discerned during mark sensing Mark color Background color White Yellow Orange Red Green Blue Black HUMAN MACHINE INTERFACES White ENERGY CONSUMPTION VISUALIZATION COMPONENTS Yellow FA COMPONENTS Orange MACHINE VISION SYSTEMS Red FX-411 (Red LED type) UV CURING SYSTEMS Green Three-chemical emitting element, Without APC Blue Black Long-term stability :Red LED type :Blue LED type :Green LED type Selection Guide Time Connector type Excellent workability and ease of maintenance The same quick-connection cable that is used for sensors such as the FX-300 series of digital fiber sensors is used. This means that they can be used together with other types of sensors such as laser sensors, and the number of power supply cables can be reduced. Laser sensor LS-401 Fiber sensor FX-411 Fiber sensor FX-411B Up to a maximum 16 sensors can be connected together Output line 3 Fiber Amplifiers Fiber sensor FX-411G Sub cable CN-71-C Main cable CN-73-C Power Output line 1 Output line 2 supply cable Main cable Fibers Output line 16 Sub cable A single output line is used, so that wiring can be greatly reduced and space savings can be obtained. The sensors can be connected together with other sensors such as the FX-300 series of digital fiber sensors and the GA-311 of inductive proximity sensors. In addition, the SC series of sensor PLC connection units with MIL connector compatibility can also be used to further reduce the amount of wiring. Quick-connection cables can be used for power supply cascade wiring. Both main and sub units utilize the same amplifier body. FX-500 FX-100 FX-300 FX-410 FX-311 FX-301-F7/ FX-301-F 169 FIBER SENSORS LASER SENSORS FX-410 SERIES Digital Fiber Sensor Contributing to device miniaturization This fiber sensor is the smallest among the dual digital display types, contributing to device miniaturization. PHOTOELECTRIC SENSORS MICRO PHOTOELECTRIC SENSORS AREA SENSORS SENSOR OPTIONS SIMPLE WIRE-SAVING UNITS WIRE-SAVING SYSTEMS MEASUREMENT SENSORS STATIC ELECTRICITY PREVENTION DEVICES LASER MARKERS ENERGY CONSUMPTION VISUALIZATION COMPONENTS Light-emitting amount can be changed without changing response time. 30.5 mm 1.201 in FT-A11 Level 2 Wire breakage detection 10 mm 0.394 in Equipped with 3 types timers Equipped with OFF-delay / ON-delay / ONE SHOT timer. (Timer period: 1 ms to 3 sec. approx.) Time chart For L-ON The digital display can be turned upside-down if required to suit the setup location. In addition, a stability indicator is also provided, so that the amount of light-receiving excess can be checked even when the display is turned off. Beam-received Sensing condition Beam-interrupted ON T1 ON-delay OFF T1 OFF-delay ONE SHOT UV CURING SYSTEMS Selection Guide Fibers Fiber Amplifiers Level 1 Digital display upside-down / off function T1 T1 T1 ON When digital display is upside-down (turned ON) Adjuster is used so that operation can be carried out confidently even when upside down. OFF ON OFF When digital display is off (Eco ON) Stability indicator Excess amount can be seen even when display is off FA COMPONENTS MACHINE VISION SYSTEMS Interference prevention for up to 8 sets fiber heads (for U-LG) Hold function The optical communication function allows up to a maximum of eight sets of fiber heads (four sets for FAST and STD settings) to be installed in contact with each other without mutual interference occurring. (Set automatically when power is turned on.) Peak and bottom hold values for the incident light intensity can be displayed. This is useful for checking the incident light intensity during tasks such as drop detection. In addition, the peak and bottom values can be checked while looking at the threshold value, which makes adjustment much easier. FD-61 Displayed sequentially Dog Hold function setting display FX-500 FX-100 FT-A11 FX-300 FX-410 FX-311 FX-301-F7/ FX-301-F Level 4 Level 3 PLC HUMAN MACHINE INTERFACES In cases where the incoming light level can become saturated, such as during close-range sensing or when sensing transparent or minute objects, the sensor's lightemitting amount can be adjusted to provide more stable sensing without changing the response time. 64.5 mm 2.539 in LIGHT CURTAINS / SAFETY COMPONENTS PRESSURE / FLOW SENSORS INDUCTIVE PROXIMITY SENSORS PARTICULAR USE SENSORS Ideal for dealing with saturation / Light-emitting amount Red LED type New concept selection function Key lock function prevents wrong operation This prevents the operator from changing the threshold value by mistake. Press and hold setting switch for 5 seconds Drop detection of minute objects Bottom hold amount display Peak hold amount display Digital Fiber Sensor FX-410 SERIES ORDER GUIDE FIBER SENSORS LASER SENSORS Amplifiers Quick-connection cable is not supplied with the amplifier. Please order it separately. Appearance NPN output PNP output NPN output Type Model No. Emitting element FX-411 Red LED FX-411B Blue LED FX-411G Green LED FX-411P Red LED FX-411BP Blue LED FX-411GP Green LED FX-412 (Note) Red LED FX-412B (Note) Blue LED FX-412G (Note) Green LED PHOTOELECTRIC SENSORS Output MICRO PHOTOELECTRIC SENSORS NPN open-collector transistor AREA SENSORS LIGHT CURTAINS / SAFETY COMPONENTS PRESSURE / FLOW SENSORS PNP open-collector transistor INDUCTIVE PROXIMITY SENSORS PARTICULAR USE SENSORS NPN open-collector transistor SENSOR OPTIONS SIMPLE WIRE-SAVING UNITS Note: The FX-412 has a threshold value adjuster that can be adjusted with your fingers. Quick-connection cables Type Sub cable (1-core) WIRE-SAVING SYSTEMS MEASUREMENT SENSORS Quick-connection cable is not supplied with the amplifier. Please order it separately. Model No. Main cable (3-core) 170 Description CN-73-C1 Length: 1 m 3.281 ft CN-73-C2 Length: 2 m 6.562 ft CN-73-C5 Length: 5 m 16.404 ft CN-71-C1 Length: 1 m 3.281 ft CN-71-C2 Length: 2 m 6.562 ft CN-71-C5 Length: 5 m 16.404 ft Main cable STATIC ELECTRICITY PREVENTION DEVICES * CN-73-C LASER MARKERS 0.2 mm 3-core cabtyre cable, with connector on one end Cable outer diameter: o3.3 mm o0.130 in 2 0.2 mm2 1-core cabtyre cable, with connector on one end Cable outer diameter: o3.3 mm o0.130 in PLC HUMAN MACHINE INTERFACES Sub cable ENERGY CONSUMPTION VISUALIZATION COMPONENTS * CN-71-C FA COMPONENTS MACHINE VISION SYSTEMS End plates End plates are not supplied with the amplifier. Please order them separately when the amplifiers are mounted in cascade. Appearance Model No. MS-DIN-E Description When cascading multiple amplifiers, or when it moves depending on the way it is installed on a DIN rail, these end plates clamp amplifiers into place on both sides. Make sure to use end plates when cascading multiple amplifiers together. Selection Guide Fibers Two pcs. pet set Fiber Amplifiers FX-500 OPTIONS Designation Amplifier mounting bracket Fiber amplifier protection seal UV CURING SYSTEMS FX-100 Model No. Description MS-DIN-2 Mounting bracket for amplifier FX-MB1 10 sets of 2 communication window seals and 1 connector seal Communication window seal: It prevents malfunction due to transmission signal from another amplifier, as well as, prevents effect on another amplifier. Connector seal: It prevents contact of any metal, etc., with the pins of the quick-connection cable. Amplifier mounting bracket * MS-DIN-2 FX-300 FX-410 FX-311 FX-301-F7/ FX-301-F Fiber amplifier protection seal * FX-MB1 Communication window seal Connector seal 171 FIBER SENSORS LASER SENSORS PHOTOELECTRIC SENSORS MICRO PHOTOELECTRIC SENSORS AREA SENSORS LIGHT CURTAINS / SAFETY COMPONENTS PRESSURE / FLOW SENSORS INDUCTIVE PROXIMITY SENSORS PARTICULAR USE SENSORS SENSOR OPTIONS SIMPLE WIRE-SAVING UNITS WIRE-SAVING SYSTEMS MEASUREMENT SENSORS STATIC ELECTRICITY PREVENTION DEVICES LASER MARKERS PLC HUMAN MACHINE INTERFACES ENERGY CONSUMPTION VISUALIZATION COMPONENTS FA COMPONENTS MACHINE VISION SYSTEMS UV CURING SYSTEMS Digital Fiber Sensor LIST OF FIBERS Thru-beam type (one pair set) Fibers Fibers are listed in alphabetic order. Refer to p.5~ "Fiber Selection" for details of each fiber. Sensing range (mm in) (Note 1) Red LED Model No. U-LG FT-140 STD Blue LED FAST U-LG STD STD Dimensions FAST 600 23.622 145 5.709 95 3.740 90 3.543 24 0.945 15 0.591 45 1.772 12 0.472 8 0.315 P.51 FT-31 540 21.260 140 5.512 85 3.346 85 3.346 20 0.787 14 0.551 38 1.496 10 0.394 7 0.276 P.51 FT-31S 540 21.260 140 5.512 85 3.346 85 3.346 20 0.787 14 0.551 38 1.496 10 0.394 7 0.276 P.51 FT-31W 380 14.961 80 3.150 55 2.165 53 2.087 16 0.630 9 0.354 28 1.102 7 0.276 4 0.157 P.51 FT-40 1,600 62.922 345 13.583 245 9.646 250 9.843 65 2.559 45 1.772 140 5.512 40 1.575 25 0.984 P.51 FT-42 1,550 61.024 340 13.386 240 9.449 230 9.055 60 2.362 40 1.575 125 4.921 33 1.299 22 0.866 P.51 FT-42S 1,550 61.024 340 13.386 240 9.449 230 9.055 60 2.362 40 1.575 125 4.921 33 1.299 22 0.866 P.51 FT-42W 1,300 51.181 290 11.417 210 8.268 220 8.661 57 2.244 33 1.299 110 4.331 32 1.260 19 0.748 P.51 FT-43 2,200 86.614 450 17.717 310 12.205 460 18.110 120 4.724 75 2.953 250 9.843 62 2.441 44 1.732 P.51 FT-45X 1,600 62.992 370 14.567 280 11.024 260 10.236 64 2.520 45 1.772 130 5.118 34 1.339 23 0.906 P.52 FT-A11 3,600 141.732 (Note 2) 2,400 94.488 1,800 70.866 1,300 51.181 350 13.780 220 8.661 770 30.315 190 7.480 120 4.724 P.52 FT-A11W 3,600 141.732 (Note 2) 2,500 98.425 2,000 78.740 1,300 51.181 350 13.780 220 8.661 550 21.654 150 5.906 130 5.118 P.52 FT-A32 3,600 141.732 (Note 2) 3,600 141.732 (Note 2) 3,600 141.732 (Note 2) 2,500 98.425 750 29.528 380 14.961 1,500 59.055 220 8.661 130 5.118 P.52 FT-A32W 3,600 141.732 (Note 2) 3,600 141.732 (Note 2) 3,600 141.732 (Note 2) 3,400 133.858 800 31.496 470 18.504 2,100 82.677 330 12.992 140 5.512 P.52 FT-AL05 FT-E13 FT-E23 FT-H13-FM2 FT-H20-J20-S (Note 3) 1,100 43.307 240 9.449 180 7.087 220 8.661 30 1.181 7 0.276 5 0.197 2.5 0.098 55 2.165 - 35 1.378 - 125 4.921 1 0.039 30 1.181 - 20 0.787 P.52 - P.52 - P.52 110 4.331 20 0.787 15 0.591 12 0.472 3 0.118 2 0.079 6 0.236 1 0.039 1,100 43.307 280 11.024 200 7.874 50 1.969 13 0.512 9 0.354 150 5.906 16 0.630 700 27.559 160 6.299 110 4.331 120 4.724 20 0.787 - 60 2.362 - - P.53 60 2.362 - - P.53 60 2.362 - - P.53 10 0.394 P.52 FT-H20-J30-S (Note 3) 700 27.559 160 6.299 110 4.331 120 4.724 20 0.787 - FT-H20-J50-S (Note 3) 700 27.559 160 6.299 110 4.331 120 4.724 20 0.787 - FT-H20-M1 550 21.654 150 5.906 100 3.937 100 3.937 25 0.984 FT-H20-VJ50-S (Note 3) 1,100 43.307 240 9.449 170 6.693 170 6.693 35 1.378 - 170 6.693 35 1.378 - 75 2.953 19 0.748 13 0.512 58 2.283 13 0.512 9 0.354 P.53 20 0.787 65 2.559 17 0.669 12 0.472 P.53 90 3.543 - - P.53 90 3.543 - - P.53 FT-H20-VJ80-S (Note 3) 1,100 43.307 240 9.449 FT-H20W-M1 400 15.748 110 4.331 FT-H30-M1V-S (Note 4) 390 15.354 100 3.937 70 2.756 75 2.953 20 0.787 15 0.591 55 2.165 13 0.512 10 0.394 P.53 FT-H35-M2 600 23.622 150 5.906 110 4.331 115 4.528 28 1.102 20 0.787 90 3.543 20 0.787 14 0.551 P.53 600 23.622 150 5.906 110 4.331 115 4.528 28 1.102 20 0.787 90 3.543 20 0.787 14 0.551 P.53 FT-HL80Y 3,500 137.795 (Note 2) 800 31.496 550 21.654 150 5.906 35 1.378 20 0.787 200 7.874 55 2.165 35 1.378 P.53 FT-KS40 3,600 141.732 (Note 2) 2,000 78.740 1,900 74.803 1,000 39.370 270 10.630 190 7.480 590 23.228 130 5.118 FT-KV26 880 34.646 170 6.693 170 6.693 80 3.15 31 1.220 FT-KV40 3,600 141.732 (Note 2) 1,700 66.929 1,300 51.181 1,200 47.244 310 12.205 FX-500 FT-KV40W 3,600 141.732 (Note 2) 1,600 62.992 1,100 43.307 900 35.433 FX-100 FT-L80Y 3,500 137.795 (Note 2) FX-300 FT-R31 380 14.961 79 3.110 FX-410 FT-R40 1,200 47.244 240 9.449 FX-311 FT-R41W 1,200 47.244 290 11.417 FT-R42W 3,600 141.732 (Note 2) 990 38.976 FT-R43 1,200 47.244 FT-R44Y 1,200 47.244 FT-R60Y FX-301-F7/ FX-301-F U-LG 19,600 771.654 (Note 2) 16,000 629.921 15,000 590.551 14,000 551.181 3,300 129.921 2,200 86.614 9,500 374.016 2,500 98.425 1,800 70.866 P.51 130 5.118 Fiber Amplifiers Green LED FAST FT-30 FT-H35-M2S6 Selection Guide FX-410 SERIES 53 2.087 P.54 - P.54 90 3.543 18 0.709 190 7.480 800 31.496 190 7.480 120 4.724 P.54 270 10.630 140 5.512 420 16.535 100 3.937 65 2.559 P.54 250 9.843 60 2.362 40 1.575 300 11.811 70 2.756 45 1.772 P.54 56 2.205 80 3.150 20 0.787 13 0.512 38 1.496 10 0.394 7 0.276 P.54 170 6.693 200 7.874 50 1.969 32 1.260 100 3.937 28 1.102 19 0.748 P.54 200 7.874 220 8.661 57 2.244 33 1.299 100 3.937 26 1.024 18 0.709 P.54 740 29.134 310 12.205 75 2.953 58 2.283 270 10.630 70 2.756 50 1.969 P.54 230 9.055 160 6.299 200 7.874 50 1.969 32 1.260 100 3.937 26 1.024 18 0.709 P.54 230 9.055 160 6.299 200 7.874 50 1.969 32 1.260 100 3.937 26 1.024 18 0.709 P.55 3,600 141.732 (Note 2) 750 29.528 540 21.260 560 22.047 140 5.512 90 3.543 290 11.417 75 2.953 50 1.969 P.55 FT-S11 150 5.906 30 1.181 20 0.787 21 0.827 5 0.197 3.5 0.138 12 0.472 2 0.079 1.5 0.059 P.55 FT-S20 600 23.622 145 5.709 95 3.740 90 3.543 24 0.945 15 0.591 45 1.772 12 0.472 8 0.315 P.55 FT-S21 540 21.260 140 5.512 85 3.346 85 3.346 20 0.787 14 0.551 38 1.496 10 0.394 7 0.276 P.55 900 35.433 120 4.724 - 600 23.622 Notes: 1) Note that the sensing range of the free-cut type fiber may be reduced by 20 % max. depending upon how the fiber is cut. 2) The fiber cable length practically limits the sensing range. 3) Heat-resistant joint fibers and ordinary-temperature fibers (FT-42) are sold as a set. 4) Sold as a set comprising vacuum type fiber + photo-terminal (FV-BR1) + fiber at atmospheric side (FT-J8). Digital Fiber Sensor 172 FX-410 SERIES LIST OF FIBERS FIBER SENSORS Thru-beam type (one pair set) LASER SENSORS Fibers are listed in alphabetic order. Refer to p.5~ "Fiber Selection" for details of each fiber. PHOTOELECTRIC SENSORS Sensing range (mm in) (Note 1) Model No. Red LED U-LG Blue LED Green LED STD FAST U-LG STD 380 14.961 80 3.150 55 2.165 53 2.087 16 0.630 9 0.354 28 1.102 7 0.276 4 0.157 P.55 FT-S30 1,600 62.992 345 13.583 245 9.646 250 9.843 65 2.559 45 1.772 140 5.512 40 1.575 25 0.984 P.55 FT-S31W 1,300 51.181 290 11.417 210 8.268 220 8.661 57 2.244 33 1.299 110 4.331 32 1.260 19 0.748 P.55 FT-S32 3,600 141.732 (Note 2) 920 36.220 670 26.378 700 27.559 180 7.087 110 4.331 400 15.748 92 3.622 62 2.441 P.55 FT-V23 720 28.346 140 5.512 100 3.937 120 4.724 30 1.181 20 0.787 65 2.559 FT-S21W FT-V24W 140 5.512 25 0.984 20 0.787 18 0.709 2 0.079 FT-V25 360 14.173 70 2.756 50 1.969 57 2.244 10 0.394 FT-V30 770 30.315 160 6.299 120 4.724 210 8.268 FT-V40 3,600 141.732 (Note 2) 950 37.402 730 28.740 810 31.890 1,500 59.055 350 13.780 250 9.843 240 9.449 390 15.354 80 3.150 55 2.165 FT-Z20W 1,300 51.181 270 10.630 FT-Z30 3,100 122.047 FAST - U-LG 5 0.197 STD Dimensions 16 0.630 - FAST 9 0.354 P.55 - P.56 8 0.315 5 0.197 P.56 100 3.937 22 0.866 10 0.394 P.56 500 19.685 115 4.528 81 3.189 P.56 35 1.378 180 7.087 38 1.496 24 0.945 P.56 16 0.630 10 0.394 30 1.181 7 0.276 5 0.197 P.56 170 6.693 39 1.535 23 0.906 92 3.622 19 0.748 11 0.433 P.56 480 18.898 250 9.843 60 2.362 37 1.457 190 7.480 51 2.008 33 1.299 P.56 3,600 141.732 (Note 2) 1,200 47.244 920 36.220 960 37.795 250 9.843 160 6.299 460 18.110 120 4.724 83 3.268 P.56 FT-Z30EW 3,600 141.732 (Note 2) 430 16.929 940 37.008 180 7.087 110 4.331 400 15.748 85 3.346 56 2.205 P.57 FT-Z30H 3,600 141.732 (Note 2) 1,300 51.181 950 37.402 1,100 43.307 290 11.417 170 6.693 580 22.835 150 5.906 100 3.937 P.57 FT-Z30HW 3,600 141.732 (Note 2) 1,300 51.181 950 37.402 940 37.008 180 7.087 110 4.331 400 15.748 85 3.346 56 2.205 P.57 7 0.276 28 1.102 47 1.850 28 1.102 190 7.480 130 5.118 55 2.165 64 2.520 190 7.480 660 25.984 FT-Z30E FT-V80Y FT-Z20HBW 590 23.228 FT-Z30W 2,400 94.488 540 21.260 390 15.354 180 7.087 45 1.772 28 1.102 160 6.299 34 1.339 21 0.827 P.57 FT-Z40HBW 1,300 51.181 290 11.417 210 8.268 220 8.661 57 2.244 33 1.299 110 4.331 32 1.260 19 0.748 P.57 FT-Z40W 2,200 86.614 460 18.110 340 13.386 380 14.961 90 3.543 63 2.480 170 6.693 45 1.772 30 1.181 P.57 FT-Z802Y 3,500 137.795 (Note 2) 750 29.528 540 21.260 450 17.717 110 4.331 80 3.150 300 11.811 80 3.150 60 2.362 P.57 MICRO PHOTOELECTRIC SENSORS AREA SENSORS LIGHT CURTAINS / SAFETY COMPONENTS PRESSURE / FLOW SENSORS INDUCTIVE PROXIMITY SENSORS PARTICULAR USE SENSORS SENSOR OPTIONS SIMPLE WIRE-SAVING UNITS WIRE-SAVING SYSTEMS MEASUREMENT SENSORS STATIC ELECTRICITY PREVENTION DEVICES LASER MARKERS PLC HUMAN MACHINE INTERFACES ENERGY CONSUMPTION VISUALIZATION COMPONENTS FA COMPONENTS Notes: 1) Note that the sensing range of the free-cut type fiber may be reduced by 20 % max. depending upon how the fiber is cut. 2) The fiber cable length practically limits the sensing range. MACHINE VISION SYSTEMS Retroreflective type UV CURING SYSTEMS Fibers are listed in alphabetic order. Refer to p.5~ "Fiber Selection" for details of each fiber. Sensing range (mm in) (Note 1,2) Model No. Red LED U-LG STD Blue LED FAST U-LG Green LED STD FAST U-LG STD - - - - Dimensions FAST - P.58 - P.58 FR-KZ22E 15 to 350 0.591 to 13.780 15 to 140 0.591 to 5.512 15 to 100 0.591 to 3.937 20 to 100 0.787 to 3.937 FR-KZ50E 20 to 400 0.787 to 15.748 20 to 200 0.787 to 7.874 20 to 200 0.787 to 7.874 20 to 200 0.787 to 7.874 20 to 84 0.787 to 3.307 20 to 45 0.787 to 1.771 20 to 180 0.787 to 7.087 20 to 55 0.787 to 1.969 FR-KZ50H 20 to 400 0.787 to 15.748 20 to 200 0.787 to 7.874 20 to 200 0.787 to 7.874 20 to 145 0.787 to 5.709 20 to 47 0.787 to 1.850 20 to 26 0.787 to 1.024 20 to 145 0.787 to 5.709 20 to 47 0.787 to 1.850 20 to 26 0.787 to 1.024 P.58 FR-Z50HW 100 to 1,000 3.937 to 39.370 100 to 540 3.937 to 21.260 100 to 460 3.937 to 18.110 100 to 490 3.937 to 19.291 - - - - - P.58 Notes: 1) Note that the sensing range of the free-cut type fiber may be reduced by 20 % max. depending upon how the fiber is cut. The sensing range of FR-KZ22E is specified for the attached reflector. The sensing range of FR-KZ50E and FR-KZ50H is specified for the attached reflector RF-003. The sensing range of FR-Z50HW is specified for the RF-13. 2) The sensing range is the possible setting range for the attached reflector. The fiber can detect an object less than setting range for the reflector. However, note that if there are any white or highly-reflective surfaces near the fiber head, reflected incident light may affect the fiber head. If this occurs, adjust the threshold value of the amplifier unit before use. Sensing range when using in combination with FR-Z50HW reflector (Optional) The sensing ranges are the value for red LED types. Reflector Model No. Sensing range (mm in) FX-411 U-LG STD FAST RF-230 100 to 12,000 3.937 to 47.244 100 to 1,700 3.937 to 66.929 100 to 1,300 3.937 to 51.181 RF-220 100 to 2,200 3.937 to 8.661 100 to 950 3.937 to 37.402 100 to 730 3.937 to 28.740 RF-210 100 to 2,100 3.937 to 82.677 100 to 780 3.937 to 30.709 100 to 620 3.937 to 24.409 Note: The sensing range is the possible setting range for the reflector. The fiber can detect an object less than setting range for the reflector. However, note that if there are any white or highly-reflective surfaces near the fiber head, reflected incident light may affect the fiber head. If this occurs, adjust the threshold value of the amplifier unit before use. Selection Guide Fibers Fiber Amplifiers FX-500 FX-100 FX-300 FX-410 FX-311 FX-301-F7/ FX-301-F 173 FIBER SENSORS Digital Fiber Sensor FX-410 SERIES LIST OF FIBERS LASER SENSORS Reflective type PHOTOELECTRIC SENSORS Fibers are listed in alphabetic order. Refer to p.5~ "Fiber Selection" for details of each fiber. MICRO PHOTOELECTRIC SENSORS AREA SENSORS LIGHT CURTAINS / SAFETY COMPONENTS PRESSURE / FLOW SENSORS INDUCTIVE PROXIMITY SENSORS PARTICULAR USE SENSORS SENSOR OPTIONS SIMPLE WIRE-SAVING UNITS WIRE-SAVING SYSTEMS MEASUREMENT SENSORS STATIC ELECTRICITY PREVENTION DEVICES LASER MARKERS PLC HUMAN MACHINE INTERFACES ENERGY CONSUMPTION VISUALIZATION COMPONENTS FA COMPONENTS MACHINE VISION SYSTEMS UV CURING SYSTEMS Sensing range (mm in) (Note 1, 2) / Description Red LED Model No. U-LG Fibers Fiber Amplifiers FX-500 FX-100 FX-311 FX-301-F7/ FX-301-F U-LG STD Green LED FAST U-LG STD Dimensions FAST 200 7.874 48 1.890 35 1.378 40 1.575 9 0.354 6 0.236 18 0.709 5 0.197 3 0.118 P.59 FD-31 175 6.890 45 1.772 34 1.339 35 8 5 0.197 16 4 0.157 2 0.079 P.59 FD-31W 120 4.724 20 0.787 15 0.591 16 0.630 FD-32G 240 9.449 52 2.047 38 1.496 48 1.890 11 0.433 8 0.315 24 0.945 5 0.197 4 0.157 P.59 FD-32GX 320 12.598 50 1.969 38 1.496 50 1.969 12 0.472 9 0.354 24 0.945 7 0.276 4 0.157 P.59 FD-40 200 7.874 48 1.890 35 1.378 40 1.575 9 0.354 6 0.236 18 0.709 5 0.197 3 0.118 P.59 FD-41 175 6.890 45 1.772 34 1.339 35 1.378 8 0.315 5 0.197 16 0.630 4 0.157 2 0.079 P.59 FD-41S 175 6.890 40 1.575 30 1.181 35 1.378 8 0.315 5 0.197 16 0.630 4 0.157 2 0.079 P.59 FD-41SW 120 4.724 20 0.787 15 0.591 18 0.709 1 to 4 0.039 to 0.157 1 to 2.5 0.039 to 0.098 12 0.472 1 to 2.5 0.039 to 0.098 FD-41W 330 12.992 70 2.756 50 1.969 54 2.126 0.5 to 13 0.020 to 0.512 1 to 8 0.039 to 0.315 29 1.142 1.5 to 7 0.059 to 0.276 1.5 to 4.5 0.059 to 0.177 P.59 FD-42G 240 9.449 52 2.047 38 1.496 48 1.890 8 0.315 24 0.945 FD-42GW 240 9.449 40 1.575 30 1.181 30 1.181 7 0.276 5 0.197 15 0.591 4 0.157 2 0.079 P.60 FD-60 600 23.622 150 5.906 100 3.937 130 5.118 30 1.181 20 0.787 70 2.756 20 0.787 13 0.512 P.60 FD-61 510 20.079 140 5.512 90 3.543 105 4.134 27 1.063 18 0.709 65 2.559 16 0.630 11 0.433 P.60 FD-61G 460 18.110 110 4.331 80 3.150 105 4.134 27 1.063 18 0.709 55 2.165 15 0.591 9 0.354 P.60 FD-61S 500 19.685 140 5.512 95 3.740 105 4.134 27 1.063 18 0.709 65 2.559 16 0.630 11 0.433 P.60 FD-61W 330 12.992 70 2.756 50 1.969 54 2.126 0.5 to 13 0.020 to 0.512 1 to 8 0.039 to 0.315 29 1.142 1.5 to 7 0.059 to 0.276 1.5 to 4.5 0.059 to 0.177 P.60 FD-62 820 32.283 180 7.087 130 5.118 160 6.299 1 to 44 0.039 to 1.732 1 to 29 0.039 to 1.142 98 3.858 1 to 26 0.039 to 1.024 1 to 18 0.039 to 0.709 P.60 FD-64X 380 14.961 80 3.150 55 2.165 54 2.126 0.5 to 14 0.020 to 0.551 0.5 to 9 0.020 to 0.354 27 1.063 0.5 to 7 0.020 to 0.276 0.5 to 4.5 0.020 to 0.177 P.61 FD-A16 200 7.874 100 3.937 75 2.953 30 1.181 13 0.512 13 0.512 57 2.244 14 0.551 FD-AL11 460 18.110 100 3.937 70 2.756 70 2.756 17 0.669 10 0.394 45 1.772 9 0.354 FD-E13 20 0.787 4 0.157 3 0.118 2.5 0.098 0.7 0.028 FD-E23 75 2.953 15 0.591 10 0.394 10 0.394 2.5 0.098 1.5 0.059 5 0.197 1.3 0.051 0.9 0.035 P.61 FD-EG30 90 3.543 15 0.591 10 0.394 10 0.394 2.5 0.098 1.5 0.059 5 0.197 1.3 0.051 0.9 0.035 P.61 FD-EG30S 85 3.346 15 0.591 10 0.394 10 0.394 2.5 0.098 1.5 0.059 5 0.197 FD-EG31 25 0.984 5 0.197 4 0.157 4 0.157 1 0.039 0.5 0.020 2 0.079 1.378 0.315 3 0.118 1 to 2.5 0.039 to 0.098 11 0.433 - 0.630 7 0.276 1 to 2.5 0.039 to 0.098 1.5 0.059 5 0.197 - 1.3 0.051 - - - P.59 P.59 4 0.157 P.60 - P.61 6 0.236 P.61 - P.61 0.9 0.035 P.62 - P.62 Applicable pipe diameter: Outer dia. o6 to o26 mm o0.236 to o1.024 in transparent pipe [PFA (fluorine resin) or equivalently transparent pipe, wall thickness 1 mm 0.039 in] Liquid absent: Beam received, Liquid present: Beam interrupted P.62 Applicable pipe diameter: Outer dia. o6 to o26 mm o0.236 to o1.024 in transparent pipe [PVC (vinyl chloride), fluorine resin, polycarbonate, acrylic, glass, wall thickness 1 to 3 mm 0.039 to 0.118 in] Liquid absent: Beam received, Liquid present: Beam interrupted P.62 FD-F41Y (Note 3) o4 mm o0.157 in Protective tube: Fluorine resin, length 500 mm 19.685 in (cuttable) Liquid surface not contacted: Beam received, Liquid surface contacted: Beam interrupted P.62 FD-F8Y o6 mm o0.236 in Protective tube: Fluorine resin, length 1,000 mm 39.370 in (not cuttable) Liquid surface not contacted: Beam received, Liquid surface contacted: Beam interrupted P.62 Applicable pipe diameter: Outer dia. o8 mm o0.315 in or more transparent pipe (When used with the tying bands: o8 to o80 mm o0.315 to o3.150 in) [PFA (fluorine resin), including translucent] Liquid absent: Beam received, Liquid present: Beam interrupted P.62 FD-F41 FX-300 FX-410 FAST FD-30 FD-F4 Selection Guide Blue LED STD FD-FA93 FD-H13-FM2 FD-H18-L31 430 16.929 100 3.937 70 2.756 0 to 25 0 to 0.984 0 to 10 0 to 0.394 0 to 8 0 to 0.315 FD-H20-21 350 13.780 FD-H20-M1 270 10.630 2.5 to 29 FD-H25-L43 (Note 4) 0.098 to 1.142 5 to 42 FD-H25-L45 (Note 4) 0.197 to 1.654 90 3.543 40 1.575 - 10 0.394 - 7 0.276 - 40 1.575 - 10 0.394 - 7 0.276 P.63 - P.63 65 2.559 65 2.559 13 0.512 9 0.354 45 1.772 10 0.394 7 0.276 P.63 85 3.346 60 2.362 60 2.362 14 0.551 10 0.394 58 2.283 10 0.394 7 0.276 P.63 4 to 20 0.157 to 0.787 7 to 38 0.276 to 1.496 4 to 16 0.157 to 0.630 7 to 35 0.276 to 1.437 - - - - - - P.63 - - - - - - P.63 Notes: 1) Note that the sensing range of the free-cut type fiber may be reduced by 20 % max. depending upon how the fiber is cut. 2) The sensing range is specified for white non-glossy paper. 3) Liquid inflow prevention joint, protective tube extension joint, fiber mounting joint are available. Please refer to p.38 for details. 4) The sensing range is specified for transparent glass 100 x 100 x t0.7 mm 3.937 x 3.937 x t0.028 in Digital Fiber Sensor 174 FX-410 SERIES LIST OF FIBERS FIBER SENSORS Reflective type LASER SENSORS Fibers are listed in alphabetic order. Refer to p.5~ "Fiber Selection" for details of each fiber. PHOTOELECTRIC SENSORS Sensing range (mm in) (Note 1, 2) / Description Red LED U-LG STD FAST U-LG STD FAST FD-H30-KZ1V-S (Note 3,4) FD-H30-L32 FD-H30-L32V-S (Note 3,4) FD-H35-20S 20 to 300 25 to 100 25 to 45 0.787 to 11.811 0.984 to 3.937 0.984 to 1.772 - - - - - - P.64 0 to 20 0 to 0.787 1 to 8 0.039 to 0.315 1 to 6 0.039 to 0.236 - - - - - - P.64 LIGHT CURTAINS / SAFETY COMPONENTS 0 to 11 1.5 to 5 2 to 4 0 to 0.433 0.059 to 0.197 0.079 to 0.157 - - - - - - P.64 PRESSURE / FLOW SENSORS INDUCTIVE PROXIMITY SENSORS U-LG STD Blue LED FAST Green LED Dimensions MICRO PHOTOELECTRIC SENSORS Model No. AREA SENSORS 210 8.268 50 1.969 35 1.378 45 1.772 10 0.394 7 0.276 20 0.787 6 0.236 4 0.157 P.64 FD-H35-M2 300 11.811 83 3.268 60 2.362 50 1.969 12 0.472 9 0.354 50 1.969 10 0.394 7 0.276 P.64 FD-H35-M2S6 FD-HF40Y (Note 5) 300 11.811 80 3.150 50 1.969 50 1.969 14 0.551 10 0.394 40 1.575 10 0.394 7 0.276 P.64 PARTICULAR USE SENSORS P.64 SENSOR OPTIONS - P.65 - P.65 SIMPLE WIRE-SAVING UNITS - P.65 - P.65 o4 mm o0.157 in Protective tube: fluorine resin, length:500 mm 19.685 in (allowable cutting) Liquid surface not contacted: Beam received, Liquid surface contacted: Beam interrupted FD-L10 (Note 3) 0 to 4.4 0 to 0.173 0 to 4 0 to 0.157 0 to 3.8 0 to 0.150 3.5 0.138 2.5 0.098 FD-L11 (Note 3) 0 to 10 0 to 0.394 0 to 7 0 to 0.276 0 to 7 0 to 0.276 8.5 0.335 6 0.236 FD-L12W (Note 3) 0.5 to 10 0.020 to 0.394 1 to 4.5 0.039 to 0.177 1 to 3.5 0.039 to 0.137 FD-L20H - - 2 0.079 0 to 3 0 to 0.118 1 to 2 0.039 to 0.079 5.5 0.217 - 8 0.315 - 5 0.197 - 1 to 32 0.039 to 1.260 4 to 10 0.157 to 0.394 4.5 to 10 0.177 to 0.394 4 to 13 0.157 to 0.512 5 to 9 0.197 to 0.354 5.5 to 8.5 0.217 to 0.334 5 to 11 0.197 to 0.433 6 to 8.5 0.236 to 0.335 WIRE-SAVING SYSTEMS MEASUREMENT SENSORS FD-L21 (Note 3) 1 to 18 0.039 to 0.709 3 to 14 0.118 to 0.551 3 to 13 0.118 to 0.512 - - - - - - P.65 FD-L21W (Note 3) 3 to 16 0.118 to 0.630 7 to 12 0.276 to 0.472 7 to 11 0.276 to 0.433 - - - - - - P.65 FD-L22A (Note 3) 0 to 26 0 to 1.024 0 to 23 0 to 0.906 0 to 19 0 to 0.748 - - - - - - P.65 FD-L23 (Note 3) 0 to 30 0 to 1.181 0 to 30 0 to 1.181 0 to 28 0 to 1.102 - - - - - - P.65 FD-L30A (Note 3) 0 to 50 0 to 1.969 0 to 36 0 to 1.417 0 to 30 0 to 1.181 - - - - - - P.65 PLC FD-L31A (Note 3) 4 to 33 0.157 to 1.299 5 to 32 0.197 to 1.260 5 to 30 0.197 to 1.181 4 to 31 0.157 to 1.220 - - - - - P.65 FD-L32H (Note 3) 0 to 65 0 to 2.559 15 to 30 0.591 to 1.181 20 to 25 0.787 to 0.984 15 to 30 0.591 to 1.181 - - - - - P.66 HUMAN MACHINE INTERFACES FD-R31G 240 9.449 42 1.654 30 1.181 41 1.614 9 0.354 6 0.236 21 0.827 5 0.197 FD-R32EG 90 3.543 15 0.591 10 0.394 10 0.394 2.5 0.098 1.5 0.059 5 0.197 1.3 0.051 FD-R33EG 25 0.984 5 0.197 3 0.118 4 0.157 0.8 0.031 FD-R34EG 75 2.953 13 0.512 8 0.315 9 0.354 2 0.079 - 1 0.039 2 0.079 5 0.197 - 0.9 0.035 2 0.079 P.66 - P.66 - P.66 - P.66 FD-R41 330 12.992 65 2.559 47 1.850 51 2.008 10 0.394 1 to 8 0.039 to 0.315 25 0.984 1 to 6 0.039 to 0.236 1 to 5 0.039 to 0.197 P.66 FD-R60 420 16.535 110 4.331 80 3.150 82 3.228 23 0.906 59 2.323 FD-R61Y 340 13.386 65 2.559 47 1.850 60 2.362 0.5 to 15 0.020 to 0.591 0.5 to 10 0.020 to 0.394 30 1.181 0.5 to 7 0.020 to 0.276 1 to 5 0.039 to 0.197 P.66 FD-S21 80 3.150 18 0.709 13 0.512 12 0.472 2.5 0.098 2 0.079 6.5 0.256 1.5 0.059 1 0.039 P.66 FD-S30 200 7.874 48 0.890 35 1.378 40 1.575 9 0.354 6 0.236 18 0.709 5 0.197 3 0.118 P.67 FD-S31 175 6.890 45 1.772 34 1.339 35 1.378 8 0.315 5 0.197 16 0.630 4 0.157 2 0.079 P.67 FD-S32 510 20.079 120 4.724 90 3.543 105 4.134 27 1.063 18 0.709 65 2.559 16 0.630 11 0.433 P.67 FD-S32W 330 12.992 70 2.756 50 1.969 54 2.126 0.5 to 13 0.020 to 0.512 1 to 8 0.039 to 0.315 29 1.142 1.5 to 7 0.059 to 0.276 1.5 to 4.5 0.059 to 0.177 P.67 FD-S33GW 240 9.449 40 1.575 30 1.181 30 1.181 7 0.276 5 0.197 15 0.591 4 0.157 FD-S60Y 410 16.142 130 5.118 100 3.937 120 4.724 25 0.984 17 0.669 65 2.559 10 0.394 FD-V30 110 4.331 19 0.748 14 0.551 18 0.709 30 1.181 5 0.197 3 0.118 160 6.299 35 1.378 25 0.984 FD-V30W FD-V50 - 27 1.063 15 0.591 - - - - 7 0.276 10 0.394 - 15 0.591 10 0.394 P.66 MACHINE VISION SYSTEMS UV CURING SYSTEMS Selection Guide Fibers Fiber Amplifiers FX-500 - - P.67 FX-100 - - P.67 FX-300 - 16 0.630 - - P.68 3 to 8 0.118 to 0.315 - - P.68 FD-Z20W 140 5.512 3 to 26 0.118 to 1.024 3 to 17 0.118 to 0.669 4 to 12 0.157 to 0.472 - - - - - P.68 FD-Z40HBW 420 16.535 1 to 80 0.039 to 3.150 1 to 60 0.039 to 2.362 1 to 89 0.039 to 3.504 3 to 20 1.181 to 0.787 3 to 13 1.181 to 0.512 1 to 42 0.039 to 1.654 3 to 11 0.118 to 0.433 3 to 7 0.118 to 0.276 P.68 FD-Z40W 340 13.386 1 to 67 0.039 to 2.638 1 to 48 0.039 to 1.890 1 to 55 0.039 to 2.165 5 to 10 0.197-0.394 - FA COMPONENTS P.67 - 10 to 890 0.394 to 35.039 15 to 210 0.591 to 8.268 15 to 160 0.591 to 6.299 20 to 100 0.787 to 3.937 ENERGY CONSUMPTION VISUALIZATION COMPONENTS - - FD-Z50HW LASER MARKERS 2 0.079 P.67 1 to 100 0.039 to 3.937 3 to 20 0.118 to 0.787 3 to 15 0.118 to 0.591 3 to 16 0.118 to 0.630 FD-Z20HBW STATIC ELECTRICITY PREVENTION DEVICES - 3 to 25 0.118 to 0.984 - - P.68 - 20 to 55 0.787 to 2.165 - - P.68 Notes: 1) Note that the sensing range of the free-cut type fiber may be reduced by 20 % max. depending upon how the fiber is cut. 2)The sensing range of reflective type is the value for white non-glossy paper (as for FD-H30-L32 and FD-H18-L31 50 x 50 mm 1.969 x 1.969 in glass substrate). 3) The sensing range is specified for transparent glass 100 x 100 x t0.7 mm 3.937 x 3.937 x t0.028 in (FD-L32H: R edge, FD-L21 and FD-L21W: t2 mm t0.079 in) [FD-L10: silicon wafers 100 x 100 mm 3.937 x 3.937 in]. 4) Sold as a set comprising vacuum type fiber + photo-terminal (FV-BR1) + fiber at atmospheric side (FT-J8). 5) Liquid inflow prevention joint, protective tube extension joint, fiber mounting joint are available. Please refer to p.38 for details. FX-410 FX-311 FX-301-F7/ FX-301-F 175 Digital Fiber Sensor FIBER OPTIONS FIBER SENSORS LASER SENSORS PHOTOELECTRIC SENSORS FX-410 SERIES Lens (for thru-beam type fiber) Designation Model No. MICRO PHOTOELECTRIC SENSORS LIGHT CURTAINS / SAFETY COMPONENTS Expansion lens (Note 1) PRESSURE / FLOW SENSORS FX-LE1 INDUCTIVE PROXIMITY SENSORS PARTICULAR USE SENSORS SIMPLE WIRE-SAVING UNITS Superexpansion lens (Note 1) LASER MARKERS PLC HUMAN MACHINE INTERFACES For thru-beam type fiber WIRE-SAVING SYSTEMS Side-view lens MACHINE VISION SYSTEMS UV CURING SYSTEMS Selection Guide Fibers Fiber Amplifiers FX-500 FX-100 FX-300 FX-410 FX-311 FX-301-F7/ FX-301-F Expansion lens for vacuum fiber (Note 1) Vacuum resistant side-view lens (Note 1) FT-43 FT-42 FT-45X FT-R40 FT-H35-M2 FT-H20W-M1 FT-H20-M1 3,600 141.732 (Note 3) 2,300 90.551 1,700 66.929 3,600 141.732 (Note 3) 3,200 125.984 2,300 90.551 1,600 62.992 (Note 3) 1,600 62.992 (Note 3) 1,600 62.992 (Note 3) 3,600 141.732 (Note 3) 2,900 114.173 2,300 90.551 3,500 137.795 (Note 3) 1,100 43.307 800 31.496 1,600 62.992 (Note 3) 1,200 47.244 800 31.496 1,600 62.992 (Note 3) 800 31.496 600 23.622 FX-LE2 FX-SV1 Beam axis is bent by Sensing range for red LED type (mm in) [Lens on both sides] (Note 2) 90. Mode U-LG STD FAST Fiber * Ambient FT-43 2,300 90.551 480 18.898 350 13.780 temperature: FT-42 2,400 94.488 450 17.717 330 12.992 -60 to +300 C -76 to +572 F FT-45X 1,600 62.992 (Note 3) 530 20.866 370 14.567 (Note 5) FT-H35-M2 870 34.252 220 8.661 160 6.299 * Beam dia: FT-H20W-M1 750 29.528 200 7.874 140 5.512 o2.8 mm FT-H20-M1 870 34.252 220 8.661 160 6.299 o0.110 in FV-LE1 Sensing range increases Sensing range for red LED type (mm in) [Lens on both sides] (Note 2, 4) by 4 times or more. Mode * Ambient temperature: U-LG STD FAST Fiber -60 to +350 C -76 to +662 F (Note 5) FT-H30-M1V-S 1,600 62.992 450 17.717 300 11.811 * Beam dia: o3.6 mm o0.142 in FV-SV2 Beam axis is bent by Sensing range for red LED type (mm in) [Lens on both sides] (Note 2, 4) 90. Mode * Ambient temperature: U-LG STD FAST Fiber -60 to +300 C -76 to +572 F (Note 5) FT-H30-M1V-S 1,600 62.992 450 17.717 300 11.811 * Beam dia: o3.7 mm o0.146 in ENERGY CONSUMPTION VISUALIZATION COMPONENTS FA COMPONENTS * Ambient temperature: -60 to +350 C -76 to +662 F (Note 5) * Beam dia: o3.6 mm o0.142 in Sensing range for red LED type (mm in) [Lens on both sides] (Note 2) Tremendously increases the sensing Mode U-LG STD FAST Fiber range with large diameter lenses. FT-43 3,600 141.732 (Note 3) 3,600 141.732 (Note 3) 3,600 141.732 (Note 3) FT-42 3,600 141.732 (Note 3) 3,600 141.732 (Note 3) 3,600 141.732 (Note 3) * Ambient FT-45X 1,600 62.992 (Note 3) 1,600 62.992 (Note 3) 1,600 62.992 (Note 3) temperature: -60 to +350 C FT-R40 3,600 141.732 (Note 3) 3,600 141.732 (Note 3) 3,600 141.732 (Note 3) -76 to +662 F FT-H35-M2 3,500 137.795 (Note 3) 3,500 137.795 (Note 3) 3,500 137.795 (Note 3) (Note 5) FT-H20W-M1 1,600 62.992 (Note 3) 1,600 62.992 (Note 3) 1,600 62.992 (Note 3) * Beam dia: FT-H20-M1 1,600 62.992 (Note 3) 1,600 62.992 (Note 3) 1,600 62.992 (Note 3) o9.8 mm o0.386 in FT-H13-FM2 3,500 137.795 (Note 3) 3,500 137.795 (Note 3) 3,500 137.795 (Note 3) SENSOR OPTIONS STATIC ELECTRICITY PREVENTION DEVICES Description Increases the sensing Sensing range for red LED type (mm in) [Lens on both sides] (Note 2) range by 5 times or Mode U-LG STD FAST more. Fiber AREA SENSORS MEASUREMENT SENSORS Refer to p.69~ for details of lens dimensions. Notes: 1) Be careful sure to use it only after you have adjusted it sufficiently when installing the thru-beam type fiber equipped with the expansion lens, as the beam envelope becomes narrow and alignment is difficult. 2) The sensing ranges are the values for red LED type amplifier. Please contact our office for details on sensing ranges for other types of amplifiers. 3) The fiber cable length practically limits the sensing range. 4) T he fiber cable length for the FT-H30-M1V-S is 1 m 3.281 ft. The sensing ranges in U-LG mode take into account the length of the FT-J8 atmospheric side fiber. 5) Refer to p.15, p.18, p.33 and p.35 for the ambient temperatures of fibers to be used in combination. Digital Fiber Sensor FIBER OPTIONS FX-410 SERIES 176 Refer to p.69~ for details of lens dimensions. LASER SENSORS Lens (for reflective type fiber) Designation Pinpoint spot lens Model No. For reflective type fiber Finest spot lens FX-MR1 Pinpoint spot of o0.5 mm o0.020 in. Enables detection of minute objects or small marks. * Distance to focal point: 6 1 mm 0.236 0.039 in * Applicable fibers: FD-42G, FD-42GW * Ambient temperature: - 40 to +70 C - 40 to +158 F (Note 2) FX-MR2 The spot diameter is adjustable from Sensing range for red LED type (Note 1) o0.7 to o2 mm o0.028 to o0.079 in Screw-in depth Distance to focal point Spot diameter according to how much the fiber is screwed in. 7 mm 0.276 in o18.5 mm o0.728 in approx. o0.7 mm o0.028 in * Applicable fibers: FD-42G, FD-42GW 12 mm 0.472 in o27 mm o1.063 in approx. o1.2 mm o0.047 in * Ambient temperature: Spot -40 to +70 C -40 to +158 F (Note 1) 14 mm 0.551 in o43 mm o1.693 in approx. o2.0 mm o0.079 in diameter * Accessory: MS-EX3 (mounting bracket) Distance to focal point Extremely fine spot of o0.15 mm o0.006 in approx. achieved. * Applicable fibers: FD-EG31, FD-EG30, FD-42G, FD-42GW, FD-32G, FD-32GX * Ambient temperature: - 40 to +70 C - 40 to +158 F (Note 2) FX-MR3 Distance to focal point Finest spot lens Spot diameter FX-MR6 Screw-in depth Zoom lens Side-view type PHOTOELECTRIC SENSORS Description Screw-in depth Zoom lens FX-MR5 FIBER SENSORS Distance to focal point Spot diameter Extremely fine spot of o0.1 mm o0.004 in approx. achieved. * Applicable fibers: FD-EG31, FD-EG30, FD-42G, FD-42GW, FD-32G, FD-32GX * Ambient temperature: - 20 to +60 C - 4 to +140 F (Note 2) FX-MR2 is converted into a side-view type and can be mounted in a very small space. * Applicable fibers: FD-42G, FD-42GW * Ambient temperature: - 40 to +70 C - 40 to +158 F (Note 2) Sensing range for red LED type (Note 1) Fiber Distance to focal point Spot diameter FD-EG31 7.5 0.5 mm 0.295 0.020 in o0.15 mm o0.006 in approx. FD-EG30 FD-42G/42GW FD-32G/32GX 7.5 0.5 mm 0.295 0.020 in o0.3 mm o0.012 in approx. 7.5 0.5 mm 0.295 0.020 in o0.5 mm o0.020 in approx. Sensing range for red LED type (Note 1) Fiber Distance to focal point Spot diameter FD-EG31 7 0.5 mm 0.276 0.020 in o0.1 mm o0.004 in approx. FD-EG30 FD-42G/42GW FD-32G/32GX 7 0.5 mm 0.276 0.020 in o0.2 mm o0.008 in approx. 7 0.5 mm 0.276 0.020 in o0.4 mm o0.016 in approx. Sensing range for red LED type (Note 1) Screw-in depth Distance to focal point Spot diameter 8 mm 0.315 in 13 mm 0.512 in approx. o0.5 mm o0.020 in 10 mm 0.394 in 15 mm 0.591 in approx. o0.8 mm o0.031 in 14 mm 0.551 in 30 mm 1.181 in approx. o3.0 mm o0.118 in Notes: 1) T he sensing ranges are the values when used in combination with red LED type amplifier. Please contact our office for details on sensing ranges for other types of amplifier. 2) Refer to p.16 or p.26 for the ambient temperatures of fibers to be used in combination. MICRO PHOTOELECTRIC SENSORS AREA SENSORS LIGHT CURTAINS / SAFETY COMPONENTS PRESSURE / FLOW SENSORS INDUCTIVE PROXIMITY SENSORS PARTICULAR USE SENSORS SENSOR OPTIONS SIMPLE WIRE-SAVING UNITS WIRE-SAVING SYSTEMS MEASUREMENT SENSORS STATIC ELECTRICITY PREVENTION DEVICES LASER MARKERS PLC HUMAN MACHINE INTERFACES ENERGY CONSUMPTION VISUALIZATION COMPONENTS FA COMPONENTS MACHINE VISION SYSTEMS UV CURING SYSTEMS Selection Guide Fibers Fiber Amplifiers FX-500 FX-100 FX-300 FX-410 FX-311 FX-301-F7/ FX-301-F 177 FIBER SENSORS LASER SENSORS Digital Fiber Sensor FIBER OPTIONS INDUCTIVE PROXIMITY SENSORS PARTICULAR USE SENSORS SENSOR OPTIONS For Square head M3 reflective fiber PRESSURE / FLOW SENSORS Distance to focal point (mm in) (Note) Spot diameter (mm in) (Note) Type MICRO PHOTOELECTRIC SENSORS LIGHT CURTAINS / SAFETY COMPONENTS Refer to p.69~ for details of lens dimensions. Lens (For square head M3 reflective fiber) PHOTOELECTRIC SENSORS AREA SENSORS FX-410 SERIES Lens Shape Model No. (mm in) Shape o0.1 o0.004 approx. o0.15 o0.006 approx. o0.2 o0.008 approx. Finest spot lens 7 0.5 0.276 0.020 o5 o0.197 15.3 0.602 FX-MR7 o0.4 o0.016 approx. SIMPLE WIRE-SAVING UNITS Type LASER MARKERS PLC HUMAN MACHINE INTERFACES ENERGY CONSUMPTION VISUALIZATION COMPONENTS FA COMPONENTS MACHINE VISION SYSTEMS Zoom lens Parallel light lens STATIC ELECTRICITY PREVENTION DEVICES For Square head M3 reflective fiber MEASUREMENT SENSORS Spot diameter (mm in) (Note) o0.4 to o2.0 o0.016 to o0.079 approx. o0.4 to o2.2 o0.016 to o0.087 approx. 10 to 30 o5 o0.197 o0.5 to o2.5 o0.020 to o0.098 approx. 0.394 to1.181 o0.8 to o3.5 o0.031 to o0.138 approx. o4.0 o0.157 approx. Designation Model No. FTP-500 (0.5m 1.641 ft) Selection Guide FX-410 FX-311 FX-301-F7/ FX-301-F FX-MR9 o0.125 o0.005 FD-EG31 o0.175 o0.007 FD-R34EG o0.25 o0.010 FD-R32EG o0.25 o0.010 FD-EG30 o0.5 o0.020 FD-R31G o0.5 o0.020 FD-32G o0.5 o0.020 FD-32GX o0.5 o0.020 FD-42G o0.5 o0.020 FD-42GW Model No. o0.125 o0.005 FD-R33EG, FD-EG31 o0.175 o0.007 FD-R34EG o0.25 o0.010 FD-R32EG, FD-EG30 o0.5 o0.020 FD-R31G, FD-32G, FD-32GX, FD-42G, FD-42GW o0.125 o0.005 FD-R33EG, FD-EG31 o0.175 o0.007 FD-R34EG o0.25 o0.010 FD-R32EG, FD-EG30 o0.5 o0.020 FD-R31G, FD-32G, FD-32GX, FD-42G, FD-42GW Description FT-42 FT-42S FT-42W For M3 FTP-N1500 (1.5m 4.922 ft) thread FT-31 FT-31S FT-31W FDP-500 (0.5m 1.641 ft) Fibers FX-300 o5 o0.197 For M4 thread Protective tube FTP-1500 (1.5m 4.922 ft) (For thru-beam FTP-N500 (0.5m 1.641 ft) type fiber) FTP-N1000 (1m 3.281 ft) FX-100 0 to 30 0 to 1.181 10 0.394 FD-R33EG Others FTP-1000 (1m 3.281 ft) FX-500 FX-MR8 o0.125 o0.005 Note: Spot diameter, distance to focal point and sensing range are specified for a red LED type amplifier. UV CURING SYSTEMS Fiber Amplifiers 15 0.591 Model No. Applicable fibers Lens Shape Emitting fiber Model No. core (mm in) (mm in) Sensing range (mm in) (Note) FDP-1000 (1m 3.281 ft) Protective tube FDP-1500 (1.5m 4.922 ft) (For reflective FDP-N500 (0.5m 1.641 ft) type fiber) FDP-N1000 (1m 3.281 ft) For M6 thread Applicable fibers WIRE-SAVING SYSTEMS Fiber Emitting fiber core (mm in) FD-61 FD-61G FD-61S FT-43 FT-H13-FM2 The protective tube, made of FD-31 noncorroFD-31W sive stainless steel, protects FD-61W the inner FD-62 fiber cable FD-H13-FM2 from any external forces. FD-41S FD-41SW For FD-41 M4 FD-41W thread FDP-N1500 (1.5m 4.922 ft) The fiber bender bends the sleeve part of the Fiber bender FB-1 fiber head at the proper radius. (Note 1) MS-AJ1-F Horizontal mounting type Mounting stand assembly for fiber Universal sensor mounting stand (Note 2) MS-AJ2-F Vertical mounting type (For M3,M4 or M6 threaded head fiber) Single-core holder FX-AT15A Protective tube * FB-1 Universal sensor mounting stand Using the arm which enables adjustment in the horizontal direction, sensing can also be done from above an assembly line. * MS-AJ1-F Swivel: 360 rotation Forward / back adjustment: 130 mm 5.118 in approx. Height adjustment: 150 mm 5.906 in approx. 360 20 20 Angle adjustment: 20 * MS-AJ2-F Mounting hole for M6 screw Swivel: 360 rotation Forward / back adjustment: 130 mm 5.118 in approx. The incident light intensity may vary when using a multi-core fiber or a thin type sharp bending fiber. This holder suppresses the variation in the incident light intensity. Brown. Notes: 1 ) Do not bend the sleeve part of any side-view type fiber or ultra-small diameter head type fiber. 2) Refer to the universal sensor mounting stand MS-AJ series pages for details. Fiber bender * FTP- * FDP- Height adjustment: 150 mm 5.906 in approx. 360 20 20 Angle adjustment: 20 Mounting hole for M6 screw Single-core holder * FX-AT15A Digital Fiber Sensor FX-410 SERIES SPECIFICATIONS Type Model No. Item FIBER SENSORS NPN output Blue LED Green LED FX-411 FX-411B FX-411G FX-412 (Note 2) FX-412B (Note 2) FX-412G (Note 2) NPN open-collector transistor * Maximum sink current: 100 mA 50 mA, if five, or more, amplifiers are connected in cascade * Applied voltage: 30 V DC or less (between output and 0 V) * Residual voltage: 1.5 V or less at 100 mA sink current 50 mA, if five, or more, amplifiers are connected in cascade PHOTOELECTRIC SENSORS FX-411P FX-411BP FX-411GP MICRO PHOTOELECTRIC SENSORS AREA SENSORS PNP open-collector transistor * Maximum source current: 100 mA 50 mA, if five, or more, amplifiers are connected in cascade * Applied voltage: 30 V DC or less (between output and +V) * Residual voltage: 1.5 V or less at 100 mA sink current 50 mA, if five, or more, amplifiers are connected in cascade DC-12 or DC-13 Incorporated Response time 150 s or less (FAST), 500 s or less (STD), 4.5 ms or less (U-LG) selectable with setting switch Operation indicator Orange LED (lights up when the output is ON) Stability indicator Green LED (lights up under stable light received condition or stable dark condition) Incorporated (Up to four sets of fiber heads can be mounted close together. However, U-LG mode is 8 fiber heads.)(Note 4) 3 (Industrial environment) 20 M, or more, with 250 V DC megger between all supply terminals connected together and enclosure (Note 5) Vibration resistance 10 to 150 Hz frequency, 0.75 mm 0.030 in amplitude in X, Y and Z directions for two hours each Shock resistance Cable length Weight WIRE-SAVING SYSTEMS STATIC ELECTRICITY PREVENTION DEVICES LASER MARKERS HUMAN MACHINE INTERFACES ENERGY CONSUMPTION VISUALIZATION COMPONENTS MACHINE VISION SYSTEMS 1,000 V AC for one min. between all supply terminals connected together and enclosure (Note 5) Insulation resistance Material SIMPLE WIRE-SAVING UNITS EN 60947-5-2 Voltage withstandability Peak emission wavelength SENSOR OPTIONS Incandescent light: 3,000 x or less at the light-receiving face EMC Emitting element (modulated) PARTICULAR USE SENSORS UV CURING SYSTEMS 35 to 85 % RH, Storage: 35 to 85 % RH Ambient illuminance INDUCTIVE PROXIMITY SENSORS FA COMPONENTS If 4 to 7 units are connected in cascade: -10 to +50 C +14 to +122 F, -10 to +55 C -14 to +131 F if 8 to 16 units are connected in cascade: -10 to +45 C +14 to +113 F (No dew condensation or icing allowed), Storage: -20 to +70 C -4 to +158 F Ambient humidity PRESSURE / FLOW SENSORS PLC Incorporated with variable ON-delay / OFF-delay / ONE SHOT timer, switchable either effective or ineffective. Timer period (Note 3): 1 ms to 3 sec. approx. (1 to 10 ms: Setting possible in units of 1 ms, 10 to 100 ms: Setting possible in units of 10 ms, 100 to 500 ms: Setting possible in units of 50 ms, 500 ms to 1 sec.: Setting possible in units of 100 ms, 1 to 3 sec.: Setting possible in units of 500 ms) Pollution degree LIGHT CURTAINS / SAFETY COMPONENTS MEASUREMENT SENSORS Switchable either Light-ON or Dark-ON Short-circuit protection Environmental resistance Green LED Normal operation: 720 mW or less (Current consumption 30 mA or less at 24 V supply voltage) ECO mode: 580 mW or less (Current consumption 24 mA or less at 24 V supply voltage) Output operation Ambient temperature Blue LED Normal operation: 960 mW or less (Current consumption 40 mA or less at 24 V supply voltage) ECO mode: 840 mW or less (Current consumption 35 mA or less at 24 V supply voltage) Utilization category Automatic interference prevention function Red LED 12 to 24 V DC 10 % Ripple P-P 10 % or less Power consumption Timer function LASER SENSORS PNP output Red LED Supply voltage Output 178 Selection Guide Fibers 98 m/s2 acceleration (10 G approx.) in X, Y and Z directions for five times each Red LED Blue LED Green LED Red LED Blue LED Green LED 650 nm 0.026 mil 470 nm 0.019 mil 525 nm 0.021 mil 650 nm 0.026 mil 470 nm 0.019 mil 525 nm 0.021 mil Enclosure: Heat-resistant ABS, Case cover: Polycarbonate Total length up to 100 m 328.084 ft (50 m 164.042 ft for 5 to 8 units, 20 m 65.617 ft for 9 to 16 units) is possible with 0.3 mm2, or more, cable. Net weight: 20 g approx., Gross weight: 30 g approx. Notes: 1) Where measurement conditions have not been specified precisely, the conditions used were an ambient temperature of +23 C +73.4 F. 2) The FX-412 has a threshold value adjuster that can be adjusted with your fingers. 3) For models manufactured up until June 2005, the timer period is approx. 1 to 500 ms. 4) When the power supply is switched on, the light emission timing is automatically set for interference prevention. 5) The voltage withstandability and the insulation resistance values given in the above table are for the amplifier only. Fiber Amplifiers FX-500 FX-100 FX-300 FX-410 FX-311 FX-301-F7/ FX-301-F 179 Digital Fiber Sensor I/O CIRCUIT DIAGRAMS FIBER SENSORS FX-41 PHOTOELECTRIC SENSORS AREA SENSORS LIGHT CURTAINS / SAFETY COMPONENTS PRESSURE / FLOW SENSORS INDUCTIVE PROXIMITY SENSORS PARTICULAR USE SENSORS SENSOR OPTIONS SIMPLE WIRE-SAVING UNITS WIRE-SAVING SYSTEMS Tr Color code of quick-connection cable Load (Brown) +V (Note 1) + 100 mA max. (Note 2) ZD 12 to 24 V DC 10 % (Blue) 0 V (Note 1) Internal circuit Users' circuit Notes: 1) The quick-connection sub cable does not have +V (brown) and 0 V (blue). The power is supplied from the connector of the main cable. 2) 50 mA max., if five amplifiers, or more, are connected together. Symbols ... D : Reverse supply polarity protection diode ZD: Surge absorption zener diode Tr : NPN output transistor PLC Part description Operation indicator (Orange) Stability indicator (Green) Operation mode switch FA COMPONENTS UV CURING SYSTEMS Digital display (Green) *Threshold value (RUN mode) Digital display (Red) *Incident light intensity (RUN mode) Setting switch Threshold value adjuster Wiring Selection Guide Fibers Fiber Amplifiers FX-500 FX-100 FX-300 FX-410 FX-311 FX-301-F7/ FX-301-F 100 mA max. (Note 2) + (Black) Output D Load (Blue) 0 V (Note 1) Internal circuit Users' circuit 12 to 24 V DC 10 % Notes: 1) T he quick-connection sub cable does not have +V (brown) and 0 V (blue). The power is supplied from the connector of the main cable. 2) 50 mA max., if five amplifiers, or more, are connected together. Symbols ... D : Reverse supply polarity protection diode ZD: Surge absorption zener diode Tr : PNP output transistor * Never use this product as a sensing device for personnel protection. * In case of using sensing devices for personnel protection, use products which meet laws and standards, such as OSHA, ANSI or IEC etc., for personnel protection applicable in each region or country. LASER MARKERS MACHINE VISION SYSTEMS ZD Tr PRECAUTIONS FOR PROPER USE STATIC ELECTRICITY PREVENTION DEVICES ENERGY CONSUMPTION VISUALIZATION COMPONENTS PNP output type (Brown) +V (Note 1) (Black) Output MEASUREMENT SENSORS HUMAN MACHINE INTERFACES FX-41P Color code of quick-connection cable D Sensor circuit MICRO PHOTOELECTRIC SENSORS NPN output type Sensor circuit LASER SENSORS FX-410 SERIES * Make sure that the power supply is off while wiring. * Verify that the supply voltage variation is within the rating. * Take care that if a voltage exceeding the rated range is applied, or if an AC power supply is directly connected, the product may get burnt or damaged. * In case noise generating equipment (switching regulator, inverter motor, etc.) is used in the vicinity of this product, connect the frame ground (F.G.) terminal of the equipment to an actual ground. * If power is supplied from a commercial switching regulator, ensure that the frame ground (F.G.) terminal of the power supply is connected to an actual ground. * Take care that short circuit of the load wrong wiring may burn or damage the product. * Do not run the wires together with high-voltage lines or power lines or put them in the same raceway. This can cause malfunction due to induction. * Extension up to total 100 m 328.084 ft (if 5 to 8 units are connected in cascade: 50 m 164.042 ft, if 9 to 16 units are connected in cascade: 20 m 65.617 ft) is possible with 0.3 mm2, or more, cable. However, in order to reduce noise, make the wiring as short as possible. * Take care that cable extension increases the residual voltage. Refer to p.1458~ for general precautions. Mounting * Make sure that the power supply is off while connecting / disconnecting the amplifiers and the quick-connection cables. How to mount the amplifier F it the rear part of the mounting section of the amplifier on a width DIN rail. P ress down the rear part of the mounting section of the unit on the width DIN rail and fit the front part of the mounting section to the DIN rail. 35 mm 1.378 in width DIN rail How to remove the amplifier ush the amplifier forward. P Lift up the front part of the amplifier to remove it. Note: T ake care that if the front part is lifted without pushing the amplifier forward, the hook on the rear portion of the mounting section is likely to break. Fiber installation * Insert the fiber into the amplifier after attaching the attachment. Refer to the "Instruction Manual" included with the fiber for details. P ush the fiber lock lever down. S lowly insert the fiber into the insertion slot until it stops. (Note 1) P ush the fiber lock lever back up until it stops. Fiber lock lever Fiber Notes: 1) N ote that if the fiber is not fully inserted, the sensing distance will decrease. Also note that the flexible fiber may bend during insertion. 2) In case of coaxial reflective type fibers, mount the central fiber (single-core) to the emitter part and the peripheral fiber (multi-core) to the receiver. Note that sensing precision will deteriorate when done in reverse. Digital Fiber Sensor PRECAUTIONS FOR PROPER USE Cascading method Sub cable (CN-71-C) (Optional) Main cable (CN-73-C) (Optional) Slide * The operation selection switch can be used to display different output operations (L-ON / D-ON) on the digital display. When set to Dark-ON (D-ON) Disappears automatically after 2 seconds. When set to Light-ON (L-ON) Disappears automatically after 2 seconds. Threshold value (sensitivity) adjustment Sensing heck the incident light C object intensity [in the digital display (Incident light intensity) (red)] when a sensing object is placed in the sensing position. Check the incident light (Incident light intensity) intensity [in the digital display (red)] when the sensing object is removed from the sensing (Threshold value) position. Turn the threshold value adjuster to the threshold value [in the digital display (green)] that is the value in between and . (The threshold value is automatically written to the EEPROM.) Threshold value setting method * When the threshold value adjuster is turned clockwise, the threshold value increases. When the threshold value adjuster is turned counterclockwise, the threshold value decreases. (Threshold value) End plate (MS-DIN-E) (Optional) Dismantling Slide PHOTOELECTRIC SENSORS MICRO PHOTOELECTRIC SENSORS AREA SENSORS LIGHT CURTAINS / SAFETY COMPONENTS PRESSURE / FLOW SENSORS INDUCTIVE PROXIMITY SENSORS PARTICULAR USE SENSORS SENSOR OPTIONS SIMPLE WIRE-SAVING UNITS WIRE-SAVING SYSTEMS MEASUREMENT SENSORS STATIC ELECTRICITY PREVENTION DEVICES LASER MARKERS PLC HUMAN MACHINE INTERFACES ENERGY CONSUMPTION VISUALIZATION COMPONENTS FA COMPONENTS MACHINE VISION SYSTEMS UV CURING SYSTEMS * If there is a sufficient level of margin in the incident light intensity, the stability indicator (green) will light up. Mode selection End plate (MS-DIN-E) (Optional) FIBER SENSORS LASER SENSORS Switching output operation * Make sure that the power supply is off while adding or removing the amplifiers. * Make sure to check the allowable ambient temperature, as it depends on the number of amplifiers connected in cascade. * In case two, or more, amplifiers are connected in cascade, make sure to mount them on a DIN rail. * When the amplifiers move on the DIN rail depending on the attaching condition or the amplifiers are mounted close to each other in cascade, fit them between the optional end plates (MS-DIN-E) mounted at the two ends. * Up to maximum 15 amplifiers can be added (total 16 amplifiers connected in cascade.) * When connecting more than two amplifiers in cascade, use the sub cable (CN-71-C) as the quickconnection cable for the second amplifier onwards. * When connecting amplifiers not close to each other in parallel, be sure to mount the optional end plate (MS-DIN-E) at both sides of each amplifier or affix the communication window seal of the optional fiber amplifier protection seal (FX-MB1) to the communication windows. For details, refer to the instruction manual enclosed with the FX-MB1. * When the different LED (red / blue / green) types are connected in cascade, mount the identical models together. * When this product is used with the other digital fiber amplifiers, be sure to place this product to the left most position (When you look from the connector side). If this product is not placed to the leftmost position, this product may not operate properly. oosen the screws of L the end plates. Remove the end plates. Slide the amplifiers and remove them one by one. 180 Refer to p.1458~ for general precautions. Cascading ount the amplifiers, M one by one, on the DIN rail. Slide the amplifiers next to each other, and connect the quick-connection cables. Mount the optional end plates (MS-DIN-E) at both the ends to hold the amplifiers between their flat sides. Tighten the screws to fix the end plates. FX-410 SERIES * When the setting switch is pressed and held for 2 sec. or more, "SET" mode (mode setting screen) is activated. * If the setting switch is pressed while in "SET" mode, the mode will change. * If the threshold value adjuster is turned while a mode is active, the setting item will change and blink. * When the setting switch is pressed at the item you would like to set, it blinks 3 times and then the setting is confirmed and the mode switches to the next mode. * If the setting switch is pressed and held for 2 sec. or more or do not press any key for 15 sec. while "SET" mode is active, the mode will switch automatically to "RUN" mode. Selection Guide Fibers Fiber Amplifiers FX-500 FX-100 FX-300 FX-410 FX-311 FX-301-F7/ FX-301-F 181 FIBER SENSORS LASER SENSORS PHOTOELECTRIC SENSORS MICRO PHOTOELECTRIC SENSORS AREA SENSORS LIGHT CURTAINS / SAFETY COMPONENTS PRESSURE / FLOW SENSORS Digital Fiber Sensor FX-410 SERIES PRECAUTIONS FOR PROPER USE Key lock function Mode table Mode Factory setting The response time can be set. Light-emitting amount selection mode (Note 1) The light-emitting amount can be switched among four levels. Timer setting mode Timer settings can be selected; Without timer / OFF-delay timer / ON-delay timer / ONE SHOT timer. Also the timer period can be set. Digital display inversion mode The display on the digital display can be inverted. Eco mode (Note 2) If no key is pressed for 20 sec. approx. while in "RUN" mode, the digital display turns off automatically. Press the setting switch or move the operation mode switch to make the display light up again. The digital display will light up when the threshold value adjuster is turned, but note that this will also cause the threshold value to change. SENSOR OPTIONS SIMPLE WIRE-SAVING UNITS WIRE-SAVING SYSTEMS MEASUREMENT SENSORS STATIC ELECTRICITY PREVENTION DEVICES LASER MARKERS PLC Peak / Bottom hold mode FA COMPONENTS MACHINE VISION SYSTEMS High-speed Response time: 150 s or less Response time change mode Standard Response time: 500 s or less Long-range Response time: 4.5 ms or less Emitting power Hi Note: This mode is not incorporated in the blue LED type and green LED type. Emitting power Lo Without timer Timer setting mode OFF-delay ON-delay ONE SHOT FX-100 The timer period can be set within the following ranges: 1 to 10 ms: 1 ms units; 10 to 100 ms: 10 ms units; 100 to 500 ms: 50 ms units 500 to 1000 ms: 100 ms units; 1000 to 3000 ms: 500 ms units FX-300 FX-410 FX-311 Factory setting * When the setting switch is pressed and held for 10 sec., until " " is displayed while in `RUN' mode, the all settings are returned to the factory setting. (For the factory setting, refer to `Mode table' in `Mode selection'.) Error display indicator readings Display (The actual display will be " ".) Digital display inversion mode FX-301-F7/ FX-301-F (Eco mode) Peak / Bottom hold mode Error description Measures The load has short-circuited Turn off the power, then and excess current is flowing. check the load. Press and hold for 2 seconds or more Selection Guide FX-500 Note: A lthough the display changes to the indication of `SET' condition 2 sec. after pressing the setting switch, keep pressing the switch. Furthermore, the sensor does not go into the key lock setting from `SET' condition. Communication error has Check if the mounted amplifiers are occurred at time of connection. in close contact with each other. Emitting intensity selection mode (Note) Fiber Amplifiers * When the setting switch is pressed and hold for 5 sec. while in `RUN' mode, Press and hold the key lock function can for 5 sec. (Note) (Set to ON) be set / canceled. * When the key lock function is set to ON, even if the (Set to OFF) threshold value adjuster or the setting switch is operated, " " is displayed and the key operation cannot be carried out. UV CURING SYSTEMS Fibers If the setting switch is pressed while "RUN" mode is active, the display will alternate between the peak hold value and the bottom hold value. (The display will refresh every 2 sec.) The display will return to normal if any operation other than threshold value setting is carried out. Notes: 1) This mode is not incorporated in the blue LED type and green LED type. 2) While the peak / bottom hold mode is ON, the digital display is not turned off even if the Eco mode is set to ON. HUMAN MACHINE INTERFACES ENERGY CONSUMPTION VISUALIZATION COMPONENTS Description Response time change mode INDUCTIVE PROXIMITY SENSORS PARTICULAR USE SENSORS Refer to p.1458~ for general precautions. (Peak value) (Bottom value) Others * Do not use during the initial transient time (0.5 sec.) after the power supply is switched on. * This sensor is suitable for indoor use only. * Do not use this sensor in places having excessive vapor, dust, etc., or where it may come in contact with corrosive gas. * Take care that the sensor does not come in direct contact with oil, grease, organic solvents, such as, thinner etc., or strong acid, and alkaline. * This sensor cannot be used in an environment containing inflammable or explosive gases. * Never disassemble or modify the sensor. * The changes to the settings are written to the EEPROM, but because the EEPROM has a limited service life, you should avoid changing the settings any more than 1 million times. Digital Fiber Sensor DIMENSIONS (Unit: mm in) 60.3 2.374 57.9 2.280 48.2 1.898 24.8 0.976 1.3 0.051 8.3 2.5 0.327 0.098 PHOTOELECTRIC SENSORS Operation mode switch MICRO PHOTOELECTRIC SENSORS 1.8 0.071 AREA SENSORS 1.3 0.051 Threshold value adjuster LIGHT CURTAINS / SAFETY COMPONENTS Setting switch Digital display (Red, Green) 3 0.118 10 0.394 64.5 Communication 2.539 window PRESSURE / FLOW SENSORS 27.8 1.094 PARTICULAR USE SENSORS 7 0.276 SENSOR OPTIONS 10.5 0.413 7 0.276 36.5 1.437 13.5 0.531 Amplifier Beamreceiving part CN-73-C1 CN-73-C2 CN-73-C5 Communication window 64.5 2.539 Operation mode switch 1.8 0.071 27.8 1.094 Model No. CN-73-C1 CN-73-C2 CN-73-C5 Length L 7 0.276 7 0.276 36.5 1.437 3.95 0.156 Suitable for 35 mm 1.378 in width DIN rail CN-71-C1 CN-71-C2 CN-71-C5 5,000196.850 2.54 0.100 5,000196.850 14 0.551 2.54 0.100 2.9 0.114 10 0.394 6 0.236 2.65 0.104 0.2 0.008 7 0.276 10 0.394 13.6 0.535 7.2 0.283 HUMAN MACHINE INTERFACES 3 0.118 10 0.394 13.6 0.535 FA COMPONENTS 7.2 0.283 MACHINE VISION SYSTEMS UV CURING SYSTEMS M3 (length 18 mm 0.709 in) pan head screws 3 0.118 15 0.591 60 2.362 3 0.118 5.6 M3 square nut 0.220 Selection Guide Fibers Fiber Amplifiers 4 0.157 Suitable for 35 mm 1.378 in width DIN rail 32 1.260 1.6 0.063 FX-500 FX-100 FX-300 Material: Polycarbonate Amplifier mounting bracket (Optional) 5.2 0.205 3 0.118 PLC 2.75 0.108 MS-DIN-2 10.5 0.413 2.54 0.100 7 0.276 24.7 0.972 o3.3 o0.130 cable 2,000 78.740 0.2 0.008 End plate (Optional) Length L 1,000 39.370 STATIC ELECTRICITY PREVENTION DEVICES ENERGY CONSUMPTION VISUALIZATION COMPONENTS MS-DIN-E L Model No. CN-71-C1 CN-71-C2 CN-71-C5 10 0.394 6 0.236 2.9 0.114 14 0.551 10.5 0.413 Sub cable (Optional) * Length L o3.3 o0.130 cable 2,000 78.740 2.65 0.104 MEASUREMENT SENSORS LASER MARKERS 1,000 39.370 2.54 0.100 3 0.118 34 1.339 10.5 0.413 30.5 1.201 3 7 0.276 0.118 13.5 0.531 Main cable (Optional) L 1.3 0.051 Threshold value adjuster Setting switch Digital display (Red, Green) 3 0.118 10 0.394 WIRE-SAVING SYSTEMS * Length L 60.3 2.374 57.9 2.280 48.2 1.898 24.8 0.976 1.3 0.051 8.3 2.5 0.327 0.098 Stability indicator (Green) Beamemitting part SIMPLE WIRE-SAVING UNITS 3.95 0.156 Suitable for 35 mm 1.378 in width DIN rail FX-412 Operation indicator (Orange) INDUCTIVE PROXIMITY SENSORS 3 0.118 30.5 1.201 3 7 0.276 0.118 Beamreceiving part FIBER SENSORS LASER SENSORS Amplifier Stability indicator (Green) Beamemitting part 182 The CAD data in the dimensions can be downloaded from our website. FX-411 FX-411P Operation indicator (Orange) FX-410 SERIES 21.6 0.850 16 0.630 10 0.394 3.2 0.126 0.4 0.016 o1.8 o0.071 7.5 0.295 4.2 0.165 2-o3.2 o0.126 holes 35 1.378 2 0.079 2 0.079 5.2 0.205 5 0.197 t1 t 0.039 27 1.063 Material: Cold rolled carbon steel (SPCC) (Uni-chrome plated) FX-311 FX-301-F7/ FX-301-F 3.2 0.126 8.5 0.335 FX-410