Photoelectric sensor in compact M18 housing E3F1 * M18 size Photoelectric sensor with best value at competitive price * Bright visible red LED enabling easy alignment * Compact and robust housing for easy integration into machines * Reliable operation in all industrial environments Ordering Information Sensors [Refer to Dimensions on page 5.] Sensor type Red light Sensing distance Through-beam 15 m Retro-reflective*2 0.1 to 3 m with E39-R1S Diffuse-reflective 100 mm 300 mm *1 *2 Model Connection method NPN output PNP output *1 E3F1-TP11 2M*1 pre-wired E3F1-TN11 2M M12 connector E3F1-TN21*1 E3F1-TP21*1 pre-wired E3F1-RN11 2M E3F1-RP11 2M M12 connector E3F1-RN21 E3F1-RP21 pre-wired M12 connector pre-wired M12 connector E3F1-DN11 2M E3F1-DN21 E3F1-DN12 2M E3F1-DN22 E3F1-DP11 2M E3F1-DP21 E3F1-DP12 2M E3F1-DP22 Includes the emitter and receiver. The Reflector is sold separately. Reflectors [Refer to Dimensions on page 6.] Reflectors required for Retro-reflective Sensors: A Reflector is not provided with the Sensor. Be sure to order a Reflector separately. Sensor E3F1-R@ Sensing distance Appearance 0.1 to 3 m Model E39-R1S Quantity Remarks 1 for E3F1-R@ Mounting brackets [Refer to Dimensions on page 6.] A Mounting Bracket is not enclosed with the Sensor. Order a Mounting Bracket separately if required. Sensor Appearance Model (Material) Quantity Remarks E39-L183 (SUS304) 1 Mounting bracket E39-L182 (POM) 1 Flush mounting bracket all types 1 E3F1 Sensor I/O connectors Models for Connectors: A Connector is not provided with the Sensor. Be sure to order a Connector separately. Sensor Size Cable Appearance Cable type 2m Straight 5m M12 connector types M12 Standard Model XS2F-M12PVC4S2M-EU XS2F-M12PVC4S5M-EU 4-wire Angle 2m XS2F-M12PVC4A2M-EU 5m XS2F-M12PVC4A5M-EU Specifications Sensing method Model NPN Pre-wired output M12 Connector Pre-wired PNP output Item M12 Connector Through-beam E3F1-TN11 2M E3F1-TN21 E3F1-TP11 2M E3F1-TP21 Retro-reflective E3F1-RN11 2M E3F1-RN21 E3F1-RP11 2M E3F1-RP21 Sensing distance 15 m 0.1 to 3 m (with E39-R1S) Spot diameter (typical) Directional angle Light source (wavelength) Power supply voltage Current consumption Control output Operation mode Indicator Protection circuits Response time Sensitivity adjustment Ambient temperature range Ambient humidity range Degree of protection Weight (packed state/only sensor) Material Pre-wired cable (2M) Connector Case Lens and Display Adjuster Nut Accessories 2 -- -- Diffuse-reflective E3F1-DN11 2M E3F1-DN12 2M E3F1-DN21 E3F1-DN22 E3F1-DP11 2M E3F1-DP12 2M E3F1-DP21 E3F1-DP22 100 mm 300 mm (white paper: (white paper: 300 300 mm) 300 300 mm) 40 45 mm 40 50 mm Sensing distance Sensing distance of 100 mm of 300 mm -- -- 2 min. 2 min. Red LED (624 nm) 10 to 30 VDC (include voltage ripple of 10%(p-p) max.) 40 mA max. (Emitter 25 mA max. 25 mA max. Receiver 15 mA max.) NPN/PNP (open collector) Load current: 100 mA max. (Residual voltage: 3 V max.), Load power supply voltage: 30 VDC max. Light-ON/Dark-ON selectable by wiring Operation indicator (orange) Stability indicator (green) Power indicator (green): only Emitter of Through-beam Reversed power supply polarity protection, Output short-circuit protection and Reversed output polarity protection 0.5 ms One-turn adjuster Operating: -25 to 55C/ Storage: -30 to 70C (with no icing or condensation) Operating: 35 to 85%RH/ Storage: 35 to 95%RH (with no condensation) IEC: IP66 Approx. 110 g/ Approx. 50 g, Approx. 60 g/ Approx. 50 g respectively Approx. 30 g/ Approx. 10 g, Approx. 20 g/ Approx. 10 g respectively ABS PMMA POM ABS Instruction sheet Instruction sheet M18 nuts (4 pcs) M18 nuts (2 pcs) E3F1 Output circuit diagram PNP Output Operation mode Model Light-ON Operation selector Timing charts Light incident Light interrupted Operation indicator ON (orange) OFF ON Output transistor OFF Operate Load (e.g., relay) Reset Connect the pink wire (Pin(2)) to the brown (Pin(1)) Output circuit Through-beam Receivers, Retro-reflective Models, Diffuse-reflective Models (Between blue and black leads) E3F1-TP@ E3F1-RP@ E3F1-DP@ Dark-ON Light incident Light interrupted Operation indicator ON (orange) OFF ON Output transistor OFF Load Operate (e.g., relay) Reset (Between blue and black leads) Stability indicator (Green) Operation indicator (Orange) 1 Light-ON 100 mA max. (Control output) Black Photoelectric Sensor Main Circuit Connect the pink wire (Pin(2)) to the blue (Pin(3)) or open the pink wire (Pin(2)) 10 to 30 VDC Brown 4 Blue Load (Relay) 3 2 0V Pink Dark-ON Through-beam Emitter Brown Power indicator (green) 1 Photoelectric Sensor Main Circuit 10 to 30 VDC Blue 3 NPN Output Operation mode Model Light-ON E3F1-TN@ E3F1-RN@ E3F1-DN@ Dark-ON Operation selector Timing charts Light incident Light interrupted Operation indicator ON (orange) OFF ON Output transistor OFF Operate Load (e.g., relay) Reset (Between brown and black leads) Output circuit Through-beam Receivers, Retro-reflective Models, Connect the Diffuse-reflective Models pink wire (Pin(2)) to the brown (Pin(1)) 10 to 30 VDC Brown Stability Operation 1 or open the indicator indicator Light-ON Load (Green) (Orange) pink wire (Relay) Black (Pin(2)) Photo100 mA max. 4 electric Sensor Main Circuit Light incident Light interrupted Operation indicator ON (orange) OFF ON Output transistor OFF Load Operate (e.g., relay) Reset (Between brown and black leads) (Control output) 3 Connect the pink wire (Pin(2)) to the blue (Pin(3)) 2 Blue 0V Pink Dark-ON Through-beam Emitter Power indicator (green) Brown 1 Photoelectric Sensor Main Circuit 10 to 30 VDC Blue 3 Connector Pin Arrangement Connectors (Sensor I/O connectors) M12 Connector Pin Arrangement M12 4-wire Connectors 1 2 Pin No. 4 2 3 1 3 4 Classification DC Wire color Brown White Blue Black 1 2 3 4 Wire color Connector pin No. Application Brown Power supply (+V) White Blue Black L/on * D/on selectable Power supply (0 V) Output 3 E3F1 Nomenclature Straight with an adjuster: E3F1-T@-D E3F1-R@ E3F1-D@ without an adjuster: E3F1-T@-L * Sensitivity adjuster Stability indicator (Green) Operation indicator (Orange) * The Emitter has two Power indicators (Green) instead of the Stability indicator (Green) and the Operation indicator (Orange). Safety Precautions Refer to Warranty and Limitations of Liability. WARNING This product is not designed or rated for directly or indirectly ensuring safety of persons. Do not use it for such a purpose. CAUTION Never use the product with an AC power supply. Do not use the product with voltage in excess of the rated voltage. Do not use the product with incorrect wiring. Otherwise, explosion, fire, malfunction may result. Precautions for Safe Use Be sure to follow the safety precautions below for added safety. 1. Do not use the sensor under the environment with explosive, flammable or corrosive gas. 2. Do not use the sensor under the oil or chemical environment. 3. Do not use the sensor in the water, rain or outdoors. 4. Do not use the sensor in the environment where humidity is high and condensation may occur. 5. Do not use the sensor under the environment under the other conditions in excess of rated. 6. Do not use the sensor in place that is exposed by direct sunlight. 7. Do not use the sensor in place where the sensor may receive direct vibration or shock. 8. Do not use the thinner, alcohol, or other organic solvents. 9. Never disassemble, repair nor tamper with the sensor. 10.Please process it as industrial waste. Precautions for Correct Use 1. Laying Sensor wiring in the same conduit or duct as high-voltage wires or power lines may result in malfunction or damage due to conduit or use shielded cable. 2. Do not pull on the cable with excessive force. 3. If a commercial switching regulator is used, ground the FG (frame ground) terminal. 4. The sensor will be available 100 ms after the power supply is tuned ON. Start to use the sensor 100 ms or more after turning ON the power supply. If the load and the sensor are connected to separate power supplies, be sure to turn ON the sensor first. 5. Output pulses may be generated even when the power supply is OFF. Therefore, it is recommended to first turn OFF the power supply for the load or the load line. 6. The sensor must be mounted using the provided nuts. The proper tightening torque range is between 0.4 and 0.5 N*m. 4 E3F1 (Unit: mm) Dimensions Tolerance class IT16 applies to dimensions in this data sheet unless otherwise specified. Sensors Pre-wired Models E3F1-T@ E3F1-R@ E3F1-D@ Front view Left side view 15 15 Receiver Emitter Optical axis M12 Connector Models E3F1-T@ E3F1-R@ E3F1-D@ Operation indicator (orenge) 2 7 dia. M18 x 30.5 P=1 Optical axis Suitable models E3F1-R@11 E3F1-D@1@ 23 30.5 * Suitable models E3F1-T@11-D E3F1-R@12 E3F1-D@1@ Right side view Sensitivity adjuster * 45 Left side view Left side view 15 15 Receiver 34.5 2 7 dia. M18 x 30.5 P=1 Operation indicator (orenge) Sensitivity indicator (green) 2 Mounting Holes 18.5+0.5 0 dia. 1 16.6 dia. 7 Emitter Suitable models E3F1-T@21 18.5+0.5 0 dia. Vinyl insurated round cord 4 dia. 4 cores (conductor cross sectional area:0.128 mm2 (AWG26) /insulation outside diameter:0.85 dia.) standard length 2 m Front view Optical axis Mounting Holes Sensitivity indicator (green) 16.6 dia. 7 Suitable models E3F1-T@11 Sensitivity adjuster * 41 34.5 Left side view Optical axis Suitable models E3F1-R@21 E3F1-D@2@ 23 30.5 M12 x 4 P=1 * Suitable models E3F1-T@21-D E3F1-R@22 E3F1-D@2@ 3 4 Terminal No. Specification 1 +V 2 L/on * D/on selectable 3 0V 4 Output Attached nut 24 dia. 8 Three, 22 M18 x 7.5 P=1 5 E3F1 Accessories (Order Separately) Reflectors E39-R1S 40.3 34 Two, 3.5 dia. 7.5 7 59.9 52 8 2.7 1.6 Mounting brackets E39-L183 Mounting brackets E39-L182 42 4.3 Two, R15 16 Two, 30 Two, 4.3 37 14.5 12.5 23 1.5 (R16.5) 27 dia. 90 18.2 dia. 15.1 36.5 20 6 16.7 dia. E3F1 7 Read and Understand This Catalog Please read and understand this catalog before purchasing the products. Please consult your OMRON representative if you have any questions or comments. Warranty and Limitations of Liability WARRANTY OMRON's exclusive warranty is that the products are free from defects in materials and workmanship for a period of one year (or other period if specified) from date of sale by OMRON. OMRON MAKES NO WARRANTY OR REPRESENTATION, EXPRESS OR IMPLIED, REGARDING NON-INFRINGEMENT, MERCHANTABILITY, OR FITNESS FOR PARTICULAR PURPOSE OF THE PRODUCTS. ANY BUYER OR USER ACKNOWLEDGES THAT THE BUYER OR USER ALONE HAS DETERMINED THAT THE PRODUCTS WILL SUITABLY MEET THE REQUIREMENTS OF THEIR INTENDED USE. OMRON DISCLAIMS ALL OTHER WARRANTIES, EXPRESS OR IMPLIED. LIMITATIONS OF LIABILITY OMRON SHALL NOT BE RESPONSIBLE FOR SPECIAL, INDIRECT, OR CONSEQUENTIAL DAMAGES, LOSS OF PROFITS OR COMMERCIAL LOSS IN ANY WAY CONNECTED WITH THE PRODUCTS, WHETHER SUCH CLAIM IS BASED ON CONTRACT, WARRANTY, NEGLIGENCE, OR STRICT LIABILITY. In no event shall the responsibility of OMRON for any act exceed the individual price of the product on which liability is asserted. IN NO EVENT SHALL OMRON BE RESPONSIBLE FOR WARRANTY, REPAIR, OR OTHER CLAIMS REGARDING THE PRODUCTS UNLESS OMRON'S ANALYSIS CONFIRMS THAT THE PRODUCTS WERE PROPERLY HANDLED, STORED, INSTALLED, AND MAINTAINED AND NOT SUBJECT TO CONTAMINATION, ABUSE, MISUSE, OR INAPPROPRIATE MODIFICATION OR REPAIR. Application Considerations SUITABILITY FOR USE OMRON shall not be responsible for conformity with any standards, codes, or regulations that apply to the combination of products in the customer's application or use of the products. At the customer's request, OMRON will provide applicable third party certification documents identifying ratings and limitations of use that apply to the products. This information by itself is not sufficient for a complete determination of the suitability of the products in combination with the end product, machine, system, or other application or use. The following are some examples of applications for which particular attention must be given. This is not intended to be an exhaustive list of all possible uses of the products, nor is it intended to imply that the uses listed may be suitable for the products: * Outdoor use, uses involving potential chemical contamination or electrical interference, or conditions or uses not described in this catalog. * Nuclear energy control systems, combustion systems, railroad systems, aviation systems, medical equipment, amusement machines, vehicles, safety equipment, and installations subject to separate industry or government regulations. * Systems, machines, and equipment that could present a risk to life or property. Please know and observe all prohibitions of use applicable to the products. NEVER USE THE PRODUCTS FOR AN APPLICATION INVOLVING SERIOUS RISK TO LIFE OR PROPERTY WITHOUT ENSURING THAT THE SYSTEM AS A WHOLE HAS BEEN DESIGNED TO ADDRESS THE RISKS, AND THAT THE OMRON PRODUCTS ARE PROPERLY RATED AND INSTALLED FOR THE INTENDED USE WITHIN THE OVERALL EQUIPMENT OR SYSTEM. PROGRAMMABLE PRODUCTS OMRON shall not be responsible for the user's programming of a programmable product, or any consequence thereof. Disclaimers CHANGE IN SPECIFICATIONS Product specifications and accessories may be changed at any time based on improvements and other reasons. It is our practice to change model numbers when published ratings or features are changed, or when significant construction changes are made. However, some specifications of the products may be changed without any notice. When in doubt, special model numbers may be assigned to fix or establish key specifications for your application on your request. Please consult with your OMRON representative at any time to confirm actual specifications of purchased products. DIMENSIONS AND WEIGHTS Dimensions and weights are nominal and are not to be used for manufacturing purposes, even when tolerances are shown. PERFORMANCE DATA Performance data given in this catalog is provided as a guide for the user in determining suitability and does not constitute a warranty. It may represent the result of OMRON's test conditions, and the users must correlate it to actual application requirements. Actual performance is subject to the OMRON Warranty and Limitations of Liability. ERRORS AND OMISSIONS The information in this document has been carefully checked and is believed to be accurate; however, no responsibility is assumed for clerical, typographical, or proofreading errors, or omissions. Cat. No. E94E-EN-01 In the interest of product improvement, specifications are subject to change without notice. OMRON EUROPE B.V. Wegalaan 67-69, NL-2132 JD, Hoofddorp, The Netherlands Phone: +31 23 568 13 00 Fax: +31 23 568 13 88 www.industrial.omron.eu