Input Voltage: 85-264 VAC, 47-63 Hz
Input Current: <6.5A RMS @ 115 VAC @ full load
<3.5A RMS @ 230 VAC @ full load
9.0A RMS @ 85 VAC @ full load
Inrush Current: <20A, pk @ 110 VAC, active soft start
<40A, pk @ 220 VAC, active soft start
(Active independant of cold or warm start)
Power Factor: >0.99 @ full load @ 230VAC input
Harmonic Distortion: Meets IEC1000-3-2
EMI Filtering: Meets CISPR 11 and 22 and FCC Part 15
Class B (conducted)
Input Protection: Internal AC line fuse; 250 VAC, 10A
Output Power: Up to 600W continuous
Line Regulation: ± 0.1%
Load Regulation: ±0.25%
PARD: <1% or 250mV
20MHz bandwidth
Hold-up Time: >16 ms @ full load
Output Polarity: Output is floating
Minimum Load: None
Transient Response: 2% for 25% load change @ 1A/µs
Output Rise Time: <100 ms (10% to 90%)
Remote Sense: Standard
Current Share: Within 5%
Remote On/Off: Ground or TTLLOW = OFF
Open or TTLHIGH = ON
AC Power Fail: TTLLOW logic “0” at least 2 ms before DC
output drops 5% (without signal jitter).
Open collector.
DC OK: Open collector when output voltage is above
95% of rated
Overcurrent/Short Circuit: Square current limit; 105-130% of rated
Overvoltage Protection: Factory set, 125% ±5%
cycle AC to reset
Reverse Voltage: Reverse current up to rated outputs
Thermal Protection: Auto off; auto reset upon cool down
Efficiency: Up to 92%
MTBF: MIL-STD-HDBK 217E
200,000 hours @ 25°C, ground benign,
Highly Accelerated Life Testing
Electrical Specifications
Continuous
Voltage Voltages Current
Codes (Volts) (Amps)
-4 12 42
-5 15 36
-6 24 23
-7 28 20
-8 36 16
-9 48 12.5
* Consult factory for other voltages and OEM quantities.
Note: Standard models are shown bold
Available Voltage Outputs*
AAD600S
Model
600 Wattsmax output power
Power Factor Correction
Single Output
Switch Mode Power Supply
H.A.L.T.
TESTED
Highly
Accelerated
Life
Testing
PART # STRUCTURE:
MODEL - VOLTAGE CODE - OPTION CODES (See back)
- V1 -
AAD600S - X - ABC....
Example: Part Number AAD600S-8-CF = 600W Power Factor Corrected, 36V @ 16A with sealed pots and overcurrent foldback
mode.
SEE 3rd PAGE FOR THE AAD600S CODE TABLE AND AVAILABLE OPTIONS.
Physical Specifications
Dimensions: (HxWxL) 1.59" x 4" x 9"
Operating Temp: 0 to 70°C; rated power to 50°C
derate linearly to 50% at 70°C.
Relative Humidity: 5% to 90%, non-condensing
Storage: -50 to 85°C/20-90% RH
Altitude: 6,561' operating;
40,000' storage
Options (code)
DC OK Invert (U) PF Invert (B)
Metric Mounting (M) Remote On/Off Invert (S)
OR-ing Diodes (O) Overcurrent Hiccup Mode (D)
Droop Current Share (A) Overcurrent Latch-off Mode (E)
Gold Plated Signal Connector (G) Overcurrent Foldback Mode (F)
Sealed Pots (C) Standby Power (5VDC @ 1A) (P)**
**Voltage available as long as AC input is present
Model
6DIHW\&RPSOLDQFH
IEC / EN / UL / CSA 60950-1
CE Declaration to Low Voltage Directive 2006/95/EC and
RoHS Directive 2011/65/EU
Surge & ESD Test Levels
EN61000-4-5 Level 3 EN61000-4-2 Level 2
EN61000-3-2 EN61000-4-2 Level 3 (Air Only)
EN61000-4-4 Level 3 EN61000-4-11
Meets Class B conducted limits per CISPR 11/22 and CFR 15 subpt B
FM 32227
© Copyright 2011 TAMURA CORPORATION OF AMERICA. Specifications subject to change without notice.
TAMURA CORPORATION OF AMERICA
1040 South Andreasen Drive, STE. 100 Escondido, CA 92029-1951
(951) 699-1270 / Fax: (951) 676-9482
(800) 472-6624
www.tamuracorp.com
AAD600S
NL
1
Item 40619 Rev A
PRODUCT CODE TABLE
Page 1 of 1 39296 Rev A2
AAD600S Series Part Number Code Table
Standard Models Tailored Models Custom Models
AAD600S-X-YYYYYY AAD600S-X-60ZZZ AAD600S-61ZZZ
P/N Codes Output Voltage and Current
Codes Standard Options
“X” Channel DC Output
Voltage
Code (V1)
Volts Amps
“Y” Code Description
A Droop Current Share
B PF Invert
C Sealed pot
D OCP Hicc-up Mode
E OCP latch off mode
F OCP fold back mode
G Gold plated signal connector
M Metric Mounting
O OR-ing Diode
P 5Vdc, 1A Standby Output
S Remote On/Off Invert (Open is off)
U DCOK Invert
Tailored Units (no safety changes: omit “X”
code
for non-standard output)
-------------------------
“60ZZZ” : “Z” – Factory
Assigned P/N
Harnesses Added,
Special test data …
ETC….
4
5
6
7
8
9
12.0 42.0
15.0 36.0
24.0 23.0
28.0 20.0
36.0 16.0
48.0 12.5
Custom Units
(safety critical changes)
-------------------------
“61ZZZ” : “Z” – Factory
Assigned P/N
ETC…..
Mouser Electronics
Authorized Distributor
Click to View Pricing, Inventory, Delivery & Lifecycle Information:
Tamura:
AAD600S-5-P AAD600S-7-P AAD600S-6-P AAD600S-9-P AAD600S-4-P AAD600S-8-P