61
©2008 Littelfuse, Inc.
Revised: July 9, 2008
Teccor® brand Thyristors
Specifications are subject to change without notice.
Please refer to http://www.littelfuse.com for current information.
Specifications are subject to change without notice.
Please refer to http://www.littelfuse.com for current information.
Lxx06xx & Qxx06xx & Qxx06xHx Series
6 Amp Sensitive, Standard & Alternistor (High Commutation) Triacs
6.0A TRIACs
Lxx06xx & Qxx06xx & Qxx06xHx Series
Description
6 Amp bi-directional solid state switch series is designed
for AC switching and phase control applications such as
motor speed and temperature modulation controls, lighting
controls, and static switching relays.
Sensitive type devices guarantee gate control in
Quadrants I & IV needed for digital control circuitry.
Standard type devices normally operate in Quadrants I &
III triggered from AC line.
Alternistor type devices only operate in quadrants I, II, &
III and are used in circuits requiring high dv/dt capability.
Features & Benefits
t3P)4DPNQMJBOU
t(MBTToQBTTJWBUFE
junctions
t7PMUBHFDBQBCJMJUZVQ
to 1000 V
t4VSHFDBQBCJMJUZVQ
to 85 A
t&MFDUSJDBMMZJTPMBUFE
“L - Package” is UL
recognized for 2500Vrms
t4PMJETUBUFTXJUDIJOH
eliminates arcing or
contact bounce that
create voltage transients
t/PDPOUBDUTUPXFBSPVU
from reaction of switching
events
t3FTUSJDUFEPSMJNJUFE3'*
generation, depending on
activation point of
sine wave
t3FRVJSFTPOMZBTNBMMHBUF
activation pulse in each
half-cycle
Main Features
Symbol Value Unit
IT(RMS) 6A
VDRM /VRRM 400 to 1000 V
IGT (Q1) 5 to 50 mA
Schematic Symbol
MT2 MT1
G
Agency Approval
Agency Agency File Number
®L Package: E71639
Absolute Maximum Ratings — Sensitive Triac (4 Quadrants)
Symbol Parameter Value Unit
IT(RMS) RMS on-state current (full sine wave) Lxx06Ly TC = 80°C 6A
Lxx06Vy / Lxx06Dy/ Lxx06Ry TC = 85°C
ITSM
Non repetitive surge peak on-state current
(full cycle, T
J initial = 25°C)
f = 50 Hz t = 20 ms 50 A
f = 60 Hz t = 16.7 ms 60
I2tI
2t Value for fusing tp = 8.3 ms 15 A2s
di/dt Critical rate of rise of on-state current
IG = 50mA with 0.1µs rise time f = 120 Hz T
J = 110°C 70 A/s
IGTM Peak gate trigger current tp c 10 s T
J = 110°C 1. 6 A
PG(AV) Average gate power dissipation T
J = 110°C 0.4 W
Tstg Storage temperature range -40 to 150 °C
T
JOperating junction temperature range -40 to 110 °C
Note: xx = voltage, y = sensitivity
Applications
Excellent for AC switching and phase control applications
such as heating, lighting, and motor speed controls.
Typical applications are AC solid-state switches, light
dimmers, power tools, home/brown goods and white
goods appliances.
Alternistor Triacs (no snubber required) are used in
applications with extremely inductive loads requiring
highest commutation performance.
Internally constructed isolated packages are offered for
ease of heat sinking with highest isolation voltage.
®
62
Revised: July 9, 2008
©2008 Littelfuse, Inc.
Teccor® brand Thyristors
Specifications are subject to change without notice.
Please refer to http://www.littelfuse.com for current information.
Specifications are subject to change without notice.
Please refer to http://www.littelfuse.com/series/triac.html for current information.
6 Amp Sensitive, Standard & Alternistor (High Commutation) Triacs
Lxx06xx & Qxx06xx & Qxx06xHx Series
Absolute Maximum Ratings — Standard Triac
Symbol Parameter Value Unit
IT(RMS) RMS on-state current (full sine wave)
Qxx06Ry / Qxx06Ny TC = 95°C
6A
Qxx06Ly TC = 90°C
ITSM
Non repetitive surge peak on-state current
(full cycle, T
J initial = 25°C)
f = 50 Hz t = 20 ms 65
A
f = 60 Hz t = 16.7 ms 80
I2tI
2t Value for fusing tp = 8.3 ms 26.5 A2s
di/dt Critical rate of rise of on-state current
IG = 200mA with 0.1µs rise time f = 120 Hz T
J = 125°C 70 A/s
IGTM Peak gate trigger current tp c 10 s; IGT c IGTM T
J = 125°C 1. 6 A
PG(AV) Average gate power dissipation T
J = 125°C 0.5 W
Tstg Storage temperature range -40 to 150 °C
T
JOperating junction temperature range -40 to 125 °C
Note: xx = voltage, y = sensitivity
Absolute Maximum Ratings — Alternistor Triac (3 Quadrants)
Symbol Parameter Value Unit
IT(RMS) RMS on-state current (full sine wave)
Qxx06LHy TC = 95°C
6A
Qxx06RHy / Qxx06NHy
Qxx06VHy / Qxx06DHy TC = 100°C
ITSM
Non repetitive surge peak on-state current
(full cycle, T
J initial = 25°C)
f = 50 Hz t = 20 ms
Qxx06VHy
Qxx06DHy 55
A
Qxx06LHy
Qxx06RHy
Qxx06NHy
80
f = 60 Hz t = 16.7 ms
Qxx06VHy
Qxx06DHy 65
Qxx06LHy
Qxx06RHy
Qxx06NHy
85
I2tI
2t Value for fusing tp = 8.3 ms
Qxx06VHy
Qxx06DHy 17.5
A2s
Qxx06LHy
Qxx06RHy
Qxx06NHy
30
di/dt Critical rate of rise of on-state current f = 120 Hz T
J = 125°C 70 A/s
IGTM Peak gate trigger current tp c 10 s; IGT c IGTM T
J = 125°C 1. 6 A
PG(AV) Average gate power dissipation T
J = 125°C 0.5 W
Tstg Storage temperature range -40 to 150 °C
T
JOperating junction temperature range -40 to 125 °C
Note: xx = voltage, y = sensitivity
63
©2008 Littelfuse, Inc.
Revised: July 9, 2008
Teccor® brand Thyristors
Specifications are subject to change without notice.
Please refer to http://www.littelfuse.com for current information.
Specifications are subject to change without notice.
Please refer to http://www.littelfuse.com for current information.
Lxx06xx & Qxx06xx & Qxx06xHx Series
6 Amp Sensitive, Standard & Alternistor (High Commutation) Triacs
6.0A TRIACs
Electrical Characteristics (T
J = 25°C, unless otherwise specified) — Sensitive Triac (4 Quadrants)
Symbol Test Conditions Quadrant Value Unit
Lxx06x5 Lxx06x6 Lxx06x8
IGT VD = 12V RL = 60 8
I – II – III
IV MAX. 5
5
5
10
10
20 mA
VGT ALL MAX. 1.3 V
VGD VD = VDRM RL = 3.3 k8 T
J = 110°C ALL MIN. 0.2 V
IHIT = 100mA MAX. 10 10 20 mA
dv/dt VD = VDRM Gate Open T
J = 100°C 400V TYP. 30 30 40 V/s
600V 20 20 30
(dv/dt)c (di/dt)c = 3.2 A/ms T
J = 110°C TYP. 1 2 2 V/s
tgt IG = 2 x IGT PW = 15µs IT = 8.5 A(pk) TYP. 3.0 3.0 3.2 s
Electrical Characteristics (T
J = 25°C, unless otherwise specified) — Standard Triac
Symbol Test Conditions Quadrant Value Unit
Qxx06x4 Qxx06x5
IGT VD = 12V RL = 60 8
I – II – III
IV
MAX.
TYP.
25
50
50
75 mA
VGT I – II – III MAX. 1.3 V
VGD VD = VDRM RL = 3.3 k8 T
J = 125°C ALL MIN. 0.2 V
IHIT = 200mA MAX. 50 50 mA
dv/dt VD = VDRM Gate Open T
J = 125°C
400V
MIN.
120
V/s
600V 100
800V 85
VD = VDRM Gate Open T
J = 100°C 1000V 100
(dv/dt)c (di/dt)c = 3.2 A/ms T
J = 125°C TYP. 4 4 V/s
tgt IG = 2 x IGT PW = 15µs IT = 8.5 A(pk) TYP. 3.0 3.0 s
Electrical Characteristics (T
J = 25°C, unless otherwise specified)Alternistor Triac (3 Quadrants)
Symbol Test Conditions Quadrant Value Unit
Qxx06xH3 Qxx06xH4
IGT VD = 12V RL = 60  I – II – III MAX. 10 35 mA
VGT I – II – III MAX. 1.3 V
VGD VD = VDRM RL = 3.3 k T
J = 125°C I – II – III MIN. 0.2 V
IHIT = 100mA MAX. 15 35 mA
dv/dt VD = VDRM Gate Open T
J = 125°C
Qxx06VHy /
Qxx06DHy
MIN.
400V 75 400
V/s
600V 50 300
800V 200
Qxx06LHy /
Qxx06RHy /
Qxx06NHy
400V 75 450
600V 50 350
800V 250
VD = VDRM Gate Open T
J = 100°C ALL 1000V 150
(dv/dt)c (di/dt)c = 3.2 A/ms T
J = 125°C MIN. 20 25 V/s
tgt IG = 2 x IGT PW = 15µs IT = 8.5 A(pk) TYP. 4.0 4.0 s
Note: xx = voltage, x = package, y = sensitivity
64
Revised: July 9, 2008
©2008 Littelfuse, Inc.
Teccor® brand Thyristors
Specifications are subject to change without notice.
Please refer to http://www.littelfuse.com for current information.
Specifications are subject to change without notice.
Please refer to http://www.littelfuse.com/series/triac.html for current information.
6 Amp Sensitive, Standard & Alternistor (High Commutation) Triacs
Lxx06xx & Qxx06xx & Qxx06xHx Series
Static Characteristics
Symbol Test Conditions Value Unit
VTM ITM = 11.3A tp = 380 µs MAX. 1.60 V
IDRM / IRRM VDRM = VRRM
Lxx06xy
T
J = 25°C 400 - 600V
MAX.
20 A
T
J = 110°C 400 - 600V 0.5 mA
Qxx06xy
T
J = 25°C 400 - 1000V 50 A
T
J = 125°C 400 - 800V 2
mA
T
J = 100°C 1000V 3
Qxx06xHy
T
J = 25°C
400 - 800V 10
A
1000V 20
T
J = 125°C 400 - 800V 3
mA
T
J = 100°C 1000V 2
Thermal Resistances
Symbol Parameter Value Unit
RR(J-C) Junction to case (AC)
L/Qxx06Ryy / L/Qxx06Nyy 1.8
°C/WL/Qxx06Lyy 3.3
L/Qxx06Vyy / L/Qxx06Dyy 3.2
RR(J-A) Junction to ambient
L/Qxx06Ryy 45
°C/WL/Qxx06Lyy 50
L/Qxx06Vyy 70
Note: xx = voltage, x = package, y = sensitivity, yy = type & sensitivity
Figure 1: Definition of Quadrants Figure 2: Normalized DC Gate Trigger Current for
All Quadrants vs. Junction Temperature
Junction Temperature (TJ)- °C
-65-40 -1510 3560 8511 0 1 2 5
4.0
3.0
2.0
1.0
0.0
Ratio of IGT
IGT (TJ = 25°C)
Note: Alternistors will not operate in QIV
MT2 POSITIVE
(Positive Half Cycle)
MT2 NEGATIVE
(Negative Half Cycle)
NOTE: Alternistors will not operate in QIV
MT1
MT2
+ IGT
REF QII
MT1
IGT
GATE
MT2
REF
MT1
MT2
REF
MT1
MT2
REF
QI
QIV
QIII
ALL POLARITIES ARE REFERENCED TO MT1
(-)
IGT
GATE
(+)
IGT -
IGT
GATE
(-)
IGT
GATE
(+)
+
-
65
©2008 Littelfuse, Inc.
Revised: July 9, 2008
Teccor® brand Thyristors
Specifications are subject to change without notice.
Please refer to http://www.littelfuse.com for current information.
Specifications are subject to change without notice.
Please refer to http://www.littelfuse.com for current information.
Lxx06xx & Qxx06xx & Qxx06xHx Series
6 Amp Sensitive, Standard & Alternistor (High Commutation) Triacs
6.0A TRIACs
Figure 3: Normalized DC Holding Current
vs. Junction Temperature
Figure 4: Normalized DC Gate Trigger Voltage for
All Quadrants vs. Junction Temperature
Junction Temperature (T
J)- °C
-65-40 -1510 3560 8511 0 1 2 5
4.0
3.0
2.0
1.0
0.0
Ratio of IH
IH (T
J = 25°C)
Junction Temperature (T
J)- °C
-65-40 -1510 3560 8511 0 1 2 5
4.0
3.0
2.0
1.0
0.0
Ratio of IH
IH (T
J = 25°C)
Figure 7: Maximum Allowable Case Temperature
vs. On-State Current (Standard Triac)
Figure 8: Maximum Allowable Case Temperature
vs. On-State Current (Alternistor Triac)
RMS On-State Current (IT(RMS)) - Amps
76543210
130
120
110
100
90
80
70
60
Maximum Allowable Case Temperature
(T
C
) - °C
Qxx06RHy
Qxx06NHy
Qxx06VHy
Qxx06DHy
Qxx06LHy
CURRENT WAVEFORM: Sinusoidal
LOAD: Resistive or Inductive
CONDUCTION ANGLE: 360°
CASE TEMPERATURE: Measured as shown
on Dimensional Drawings
RMS On-State Current (IT(RMS)) - Amps
0246810121416
0
2
4
6
8
10
12
14
16
18
Average On-State Power Dissipation
(PD(AV)) - Watts
CURRENT WAVEFORM: Sinusoidal
LOAD: Resistive or Inductive
CONDUCTION ANGLE: 360°
Figure 5: Power Dissipation (Typical)
vs. RMS On-State Current
Figure 6: Maximum Allowable Case Temperature
vs. On-State Current (Sensitive Triac)
RMS On-State Current (IT(RMS)) - Amps
76543210
120
110
100
90
80
70
60
Maximum Allowable Case Temperature
(TC) - °C
Lxx06Vy
Lxx06Dy
Lxx06Ry
Lxx06Ly
CURRENT WAVEFORM: Sinusoidal
LOAD: Resistive or Inductive
CONDUCTION ANGLE: 360°
CASE TEMPERATURE: Measured as shown
on Dimensional Drawings
RMS On-State Current (I
T(RMS)
) - Amps
76543210
130
120
110
100
90
80
70
60
Maximum Allowable Case Temperature
(TC) - °C
Qxx06Ly
CURRENT WAVEFORM: Sinusoidal
LOAD: Resistive or Inductive
CONDUCTION ANGLE: 360°
CASE TEMPERATURE: Measured as shown
on Dimensional Drawings
Qxx06Ry
Qxx06Ny
66
Revised: July 9, 2008
©2008 Littelfuse, Inc.
Teccor® brand Thyristors
Specifications are subject to change without notice.
Please refer to http://www.littelfuse.com for current information.
Specifications are subject to change without notice.
Please refer to http://www.littelfuse.com/series/triac.html for current information.
6 Amp Sensitive, Standard & Alternistor (High Commutation) Triacs
Lxx06xx & Qxx06xx & Qxx06xHx Series
Figure 9: Maximum Allowable Ambient Temperature
vs. On-State Current (Sensitive / Standard Triac)
Figure 10: Maximum Allowable Ambient Temperature
vs. On-State Current (Alternistor Triac)
RMS On-State Current [IT(RMS)] - Amps
120
100
80
60
40
20
Maximum Allowable
Ambient Temperature (T
A) - °C
2.01.81.61.41.21.00.80.60.40.20.0
CURRENT WAVEFORM: Sinusoidal
LOAD: Resistive or Inductive
CONDUCTION ANGLE: 360°
CASE TEMPERATURE: Measured as shown
on Dimensional Drawing
Qxx06LHy
Qxx06RHy
Qxx06NHy
Qxx06VHy
RMS On-State Current (IT(RMS)) - Amps
120
100
80
60
40
20
Maximum Allowable
Ambient Temperature (T
A
) - °C
2.01.81.61.41.21.00.80.60.40.20.0
Qxx06Ly
Qxx06Ry
Qxx06Ny
Lxx06Ly
Lxx06Ry
L/Qxx06Vy
CURRENT WAVEFORM: Sinusoidal
LOAD: Resistive or Inductive
CONDUCTION ANGLE: 360°
FREE AIR RATING – NO HEATSINK
Figure 11: On-State Current vs. On-State Voltage
(Typical)
1.61.51.41.31.21.11.00.90.80.7
20
18
16
14
12
10
8
6
4
2
0
TC = 25°C
Postitive or Negative Instantaneous
On-State Voltage (vT) - Volts
Postitive or Negative Instantaneous
On-State Current (iT) - Amps
67
©2008 Littelfuse, Inc.
Revised: July 9, 2008
Teccor® brand Thyristors
Specifications are subject to change without notice.
Please refer to http://www.littelfuse.com for current information.
Specifications are subject to change without notice.
Please refer to http://www.littelfuse.com for current information.
Lxx06xx & Qxx06xx & Qxx06xHx Series
6 Amp Sensitive, Standard & Alternistor (High Commutation) Triacs
6.0A TRIACs
Surge Current Duration- Full Cycles
1
Peak Surge (Non-Repetitive)
On-State Current (ITSM) - Amps
1 10 100 1000
10
100
Qxx06Ly
Qxx06Ry
Qxx06Ny
Lxx06Ly
Lxx06Ry
Lxx06Vy
Lxx06Dy
Figure 12: Surge Peak On-State Current vs. Number of Cycles (Sensitive / Standard Triac)
SUPPLY FREQUENCY: 60 Hz Sinusoidal
LOAD: Resistive
RMS On-State Current: [IT(RMS)]: Maximum Rated
Value at Specified Case Temperature
Notes:
1. Gate control may be lost during and immediately
following surge current interval.
2. Overload may not be repeated until junction
temperature has returned to steady-state
rated value.
Surge Current Duration- Full Cycles
1
Peak Surge (Non-Repetitive)
On-State Current (ITSM) - Amps
1 10 100 1000
10
100
Qxx06LHy
Qxx06RHy
Qxx06NHy
Qxx06VHy
Qxx06DHy
Figure 13: Surge Peak On-State Current vs. Number of Cycles (Alternistor Triac)
SUPPLY FREQUENCY: 60 Hz Sinusoidal
LOAD: Resistive
RMS On-State Current: [IT(RMS)]: Maximum Rated
Value at Specified Case Temperature
Notes:
1. Gate control may be lost during and immediately
following surge current interval.
2. Overload may not be repeated until junction
temperature has returned to steady-state
rated value.
Note: xx = voltage, x = package, y = sensitivity, yy = type & sensitivity
68
Revised: July 9, 2008
©2008 Littelfuse, Inc.
Teccor® brand Thyristors
Specifications are subject to change without notice.
Please refer to http://www.littelfuse.com for current information.
Specifications are subject to change without notice.
Please refer to http://www.littelfuse.com/series/triac.html for current information.
6 Amp Sensitive, Standard & Alternistor (High Commutation) Triacs
Lxx06xx & Qxx06xx & Qxx06xHx Series
Soldering Parameters
Reflow Condition Pb – Free assembly
Pre Heat
- Temperature Min (Ts(min))150°C
- Temperature Max (Ts(max))200°C
- Time (min to max) (ts)60 – 190 secs
Average ramp up rate (Liquidus Temp)
(TL) to peak 5°C/second max
TS(max) to TL - Ramp-up Rate 5°C/second max
Reflow - Temperature (TL) (Liquidus) 217°C
- Temperature (tL)60 – 150 seconds
Peak Temperature (TP)260+0/-5 °C
Time within 5°C of actual peak
Temperature (tp)20 – 40 seconds
Ramp-down Rate 5°C/second max
Time 25°C to peak Temperature (TP)8 minutes Max.
Do not exceed 280°C
Physical Specifications Environmental Specifications
Test Specifications and Conditions
AC Blocking (VDRM)MIL-STD-750, M-1040, Cond A Applied
Peak AC voltage @ 125°C for 1008 hours
Temperature Cycling
MIL-STD-750, M-1051,
100 cycles; -40°C to +150°C; 15-min
dwell-time
Temperature/
Humidity
EIA / JEDEC, JESD22-A101
1008 hours; 320V - DC: 85°C; 85%
rel humidity
High Temp Storage MIL-STD-750, M-1031,
1008 hours; 150°C
Low-Temp Storage 1008 hours; -40°C
Thermal Shock
MIL-STD-750, M-1056
10 cycles; 0°C to 100°C; 5-min dwell-
time at each temperature; 10 sec (max)
transfer time between temperature
Autoclave
EIA / JEDEC, JESD22-A102
168 hours (121°C at 2 ATMs) and
100% R/H
Resistance to
Solder Heat MIL-STD-750 Method 2031
Solderability ANSI/J-STD-002, category 3, Test A
Lead Bend MIL-STD-750, M-2036 Cond E
Terminal Finish 100% Matte Tin-plated
Body Material UL recognized epoxy meeting flammability
classification 94V-0
Terminal Material Copper Alloy
Design Considerations
Careful selection of the correct device for the applications
operating parameters and environment will go a long way
toward extending the operating life of the Thyristor. Good
design practice should limit the maximum continuous
current through the main terminals to 75% of the device
rating. Other ways to ensure long life for a power discrete
semiconductor are proper heat sinking and selection of
voltage ratings for worst case conditions. Overheating,
overvoltage (including dv/dt), and surge currents are
the main killers of semiconductors. Correct mounting,
soldering, and forming of the leads also help protect
against component damage.
Time
Temperature
TP
TL
TS(max)
TS(min)
25
tP
tL
tS
time to peak temperature
Preheat
P
reheat
Ramp-upRamp-up
Ramp-down
R
amp-
do
69
©2008 Littelfuse, Inc.
Revised: July 9, 2008
Teccor® brand Thyristors
Specifications are subject to change without notice.
Please refer to http://www.littelfuse.com for current information.
Specifications are subject to change without notice.
Please refer to http://www.littelfuse.com for current information.
Lxx06xx & Qxx06xx & Qxx06xHx Series
6 Amp Sensitive, Standard & Alternistor (High Commutation) Triacs
6.0A TRIACs
Dimensions — TO-220AB (R-Package) — Non-Isolated Mounting Tab Common with Center Lead
Dimension Inches Millimeters
Min Max Min Max
A 0.380 0.420 9.65 10.67
B 0.105 0.115 2.67 2.92
C 0.230 0.250 5.84 6.35
D 0.590 0.620 14.99 15.75
E 0.142 0.147 3.61 3.73
F 0.110 0.130 2.79 3.30
G 0.540 0.575 13.72 14.61
H 0.025 0.035 0.64 0.89
J 0.195 0.205 4.95 5.21
K 0.095 0.105 2.41 2.67
L 0.060 0.075 1.52 1.91
M 0.085 0.095 2.16 2.41
N 0.018 0.024 0.46 0.61
O 0.178 0.188 4.52 4.78
P 0.045 0.060 1.14 1.52
R 0.038 0.048 0.97 1.22
Dimensions — TO-220AB (L-Package) — Isolated Mounting Tab
Dimension Inches Millimeters
Min Max Min Max
A 0.380 0.420 9.65 10.67
B 0.105 0.115 2.67 2.92
C 0.230 0.250 5.84 6.35
D 0.590 0.620 14.99 15.75
E 0.142 0.147 3.61 3.73
F 0.110 0.130 2.79 3.30
G 0.540 0.575 13.72 14.61
H 0.025 0.035 0.64 0.89
J 0.195 0.205 4.95 5.21
K 0.095 0.105 2.41 2.67
L 0.060 0.075 1.52 1.91
M 0.085 0.095 2.16 2.41
N 0.018 0.024 0.46 0.61
O 0.178 0.188 4.52 4.78
P 0.045 0.060 1.14 1.52
R 0.038 0.048 0.97 1.22
K
J
A
H
G
B
F
ØE
C
D
L
R
T
C
MEASURING POINT AREA (REF.) 0.17 IN
2
MT2
O
P
N
M
MT1 GATE
.320
8.13
.526
13.36
.276
7. 0 1
K
J
A
H
G
B
F
ØE
C
D
L
R
T
C
MEASURING POINT
MT2
MT2
O
P
N
M
MT1
.276
7. 0 1
.526
13.36
.320
8.13
GATE
AREA (REF.) 0.17 IN
2
NOTCH IN
GATE LEAD
TO ID.
NON-ISOLATED
TAB
Note: Maximum torque to
be applied to mounting tab
is 8 in-lbs, (0.904 Nm).
Note: Maximum torque to
be applied to mounting tab
is 8 in-lbs, (0.904 Nm).
70
Revised: July 9, 2008
©2008 Littelfuse, Inc.
Teccor® brand Thyristors
Specifications are subject to change without notice.
Please refer to http://www.littelfuse.com for current information.
Specifications are subject to change without notice.
Please refer to http://www.littelfuse.com/series/triac.html for current information.
6 Amp Sensitive, Standard & Alternistor (High Commutation) Triacs
Lxx06xx & Qxx06xx & Qxx06xHx Series
Dimensions — TO-263AB (N-Package) — D2-PAK Surface Mount
Dimensions — TO-251AA (V-Package) — V-PAK Through Hole
Dimension Inches Millimeters
Min Max Min Max
A 0.040 0.050 1.02 1.27
B 0.235 0.245 5.97 6.22
C 0.350 0.375 8.89 9.53
D 0.205 0.213 5.21 5.41
E 0.255 0.265 6.48 6.73
F 0.027 0.033 0.69 0.84
G 0.087 0.093 2.21 2.36
H 0.085 0.095 2.16 2.41
I 0.176 0.184 4.47 4.67
J 0.018 0.023 0.46 0.58
K 0.038 0.044 0.97 1.12
L 0.018 0.023 0.46 0.58
Dimension Inches Millimeters
Min Max Min Max
A 0.360 0.370 9.14 9.40
B 0.380 0.420 9.65 10.67
C 0.178 0.188 4.52 4.78
D 0.025 0.035 0.64 0.89
E 0.045 0.060 1.14 1.52
F 0.060 0.075 1.52 1.91
G 0.095 0.105 2.41 2.67
H 0.092 0.102 2.34 2.59
J 0.018 0.024 0.46 0.61
K 0.090 0.110 2.29 2.79
S 0.590 0.625 14.99 15.88
V 0.035 0.045 0.89 1.14
U 0.002 0.010 0.05 0.25
W 0.040 0.070 1.02 1.78
AREA: 0.040 IN
2
T
C
MEASURING POINT
MT2
GATE
MT2
MT1
G
I
E
D
A
B
C
F
J
H
K
L
5.28
.208
5.34
.210
G
B
A
W
F
D
V
S
MT1
MT2
TC MEASURING POINT
C
E
K
H
J
U
.320
8.13
.276
7. 0 1 .331
8.41
GATE
.460
11.68
.665
16.89
.260
6.60
.150
3.81
.080
2.03
.085
2.16
.055
1.40
.350
8.89
.276
7. 0 1
.276
7. 0 1
AREA: 0.11 IN2
71
©2008 Littelfuse, Inc.
Revised: July 9, 2008
Teccor® brand Thyristors
Specifications are subject to change without notice.
Please refer to http://www.littelfuse.com for current information.
Specifications are subject to change without notice.
Please refer to http://www.littelfuse.com for current information.
Lxx06xx & Qxx06xx & Qxx06xHx Series
6 Amp Sensitive, Standard & Alternistor (High Commutation) Triacs
6.0A TRIACs
Dimensions — TO-252AA (D-Package) — D-PAK Surface mount
Dimension Inches Millimeters
Min Max Min Max
A 0.040 0.050 1.02 1.27
B 0.235 0.245 5.97 6.22
C 0.106 0.113 2.69 2.87
D 0.205 0.213 5.21 5.41
E 0.255 0.265 6.48 6.73
F 0.027 0.033 0.69 0.84
G 0.087 0.093 2.21 2.36
H 0.085 0.095 2.16 2.41
I 0.176 0.184 4.47 4.67
J 0.018 0.023 0.46 0.58
K 0.038 0.044 0.97 1.12
L 0.018 0.023 0.46 0.58
M 0.000 0.004 0.00 0.10
N 0.021 0.027 0.53 0.69
O0°5°0°5°
GATE
MT2
MT2
MT1
T
C
MEASURING POINT
G
I
D
E
A
B
C
F
5.28
.208
5.34
.210
: 0.040 IN
2
AREA
M
O
N
H
J
L
K
.118
3
.063
1.60
.071
1.80
.264
6.71
.264
6.71
.181
4.60
Pad Layout for TO-252AA (D-Package)
72
Revised: July 9, 2008
©2008 Littelfuse, Inc.
Teccor® brand Thyristors
Specifications are subject to change without notice.
Please refer to http://www.littelfuse.com for current information.
Specifications are subject to change without notice.
Please refer to http://www.littelfuse.com/series/triac.html for current information.
6 Amp Sensitive, Standard & Alternistor (High Commutation) Triacs
Lxx06xx & Qxx06xx & Qxx06xHx Series
Product Selector
Packing Options
Part Number Voltage Gate Sensitivity Quadrants Type Package
400V 600V 800V 1000V I - II - III IV
Lxx06L5 X X 5 mA 5 mA Sensitive Triac TO-220L
Lxx06D5 X X 5 mA 5 mA Sensitive Triac TO-252 D-PAK
Lxx06R5 X X 5mA 5mA Sensitive Triac TO-220R
Lxx06V5 X X 5 mA 5 mA Sensitive Triac TO-251 V-PAK
Lxx06L6 X X 5 mA 10 mA Sensitive Triac TO-220L
Lxx06D6 X X 5 mA 10 mA Sensitive Triac TO-252 D-PAK
Lxx06R6 X X 5mA 10mA Sensitive Triac TO-220R
Lxx06V6 X X 5 mA 10 mA Sensitive Triac TO-251 V-PAK
Lxx06L8 X X 10 mA 20 mA Sensitive Triac TO-220L
Lxx06D8 X X 10 mA 20 mA Sensitive Triac TO-252 D-PAK
Lxx06R8 X X 10mA 20mA Sensitive Triac TO-220R
Lxx06V8 X X 10 mA 20 mA Sensitive Triac TO-251 V-PAK
Qxx06VH3 X X 10 mA Alternistor Triac TO-251 V-PAK
Qxx06DH3 X X 10 mA Alternistor Triac TO-252 D-PAK
Qxx06L4 X 25 mA Standard Triac TO-220L
Qxx06R4 X 25 mA Standard Triac TO-220R
Qxx06N4 X 25 mA Standard Triac TO-263 D²-PAK
Qxx06RH3 X X 10mA Alternistor Triac TO-220R
Qxx06LH4 XXXX 35 mA Alternistor Triac TO-220L
Qxx06RH4 XXXX 35 mA Alternistor Triac TO-220R
Qxx06VH4 XXXX 35 mA Alternistor Triac TO-251 V-PAK
Qxx06DH4 XXXX 35 mA Alternistor Triac TO-252 D-PAK
Qxx06NH4 XXXX 35 mA Alternistor Triac TO-263 D²-PAK
Qxx06L5 X X X 50 mA Standard Triac TO-220L
Qxx06R5 X X X 50 mA Standard Triac TO-220R
Qxx06N5 X X X 50 mA Standard Triac TO-263 D²-PAK
Part Number Marking Weight Packing Mode Base Quantity
Lxx06L/Ry Lxx06L/Ry 2.2 g Bulk 500
Lxx06L/RyTP Lxx06L/Ry 2.2 g Tube Pack 500
Lxx06DyTP Lxx06Dy 0.3 g Tube 750
Lxx06DyRP Lxx06Dy 0.3 g Embossed Carrier 2500
Lxx06VyTP Lxx06Vy 0.4 g Tube 750
Qxx06L/Ryy Qxx06L/Ryy 2.2 g Bulk 500
Qxx06L/RyyTP Qxx06L/Ryy 2.2 g Tube Pack 500
Qxx06NyyTP Qxx06Nyy 1.6 g Tube 500
Qxx06NyyRP Qxx06Nyy 1.6 g Embossed Carrier 500
Qxx06DyyTP Qxx06Dyy 0.3 g Tube 750
Qxx06DyyRP Qxx06Dyy 0.3 g Embossed Carrier 2500
Qxx06VyyTP Qxx06Vyy 0.4 g Tube 750
Note: xx = voltage; yy = sensitivity
73
©2008 Littelfuse, Inc.
Revised: July 9, 2008
Teccor® brand Thyristors
Specifications are subject to change without notice.
Please refer to http://www.littelfuse.com for current information.
Specifications are subject to change without notice.
Please refer to http://www.littelfuse.com for current information.
Lxx06xx & Qxx06xx & Qxx06xHx Series
6 Amp Sensitive, Standard & Alternistor (High Commutation) Triacs
6.0A TRIACs
0.512 (13.0) Arbor
Hole Dia.
DC
DC
XXXXXX
DC
Gate MT1 / Cathode
MT2 / Anode
0.63
(16.0)
0.157
(4.0)
0.64
(16.3)
12.99
(330.0)
0.524
(13.3)
0.315
(8.0)
0.059 DIA
(1.5)
*
* Cover tape
Direction of Feed
Dimensions
are in inches
(and millimeters).
Gate
MT1 / Cathode
MT2 / Anode
0.512 (13.0) Arbor
Hole Dia.
0.945
(24.0)
0.63
(16.0)
1.01
(25.7)
12.99
(330.0)
0.827
(21.0)
0.157
(4.0)
Direction of Feed
Dimensions
are in inches
(and millimeters).
*
* Cover tape
0.059 DIA
(1.5)
TO-252 Embossed Carrier Reel Pack (RP) Specifications
Meets all EIA-481-2 Standards
TO-263 Embossed Carrier Reel Pack (RP) Specifications
Meets all EIA-481-2 Standards
74
Revised: July 9, 2008
©2008 Littelfuse, Inc.
Teccor® brand Thyristors
Specifications are subject to change without notice.
Please refer to http://www.littelfuse.com for current information.
Specifications are subject to change without notice.
Please refer to http://www.littelfuse.com/series/triac.html for current information.
6 Amp Sensitive, Standard & Alternistor (High Commutation) Triacs
Lxx06xx & Qxx06xx & Qxx06xHx Series
Part Numbering System Part Marking System
CURRENT
06: 6A
SENSITIVITY & TYPE
Sensitive Triac:
3
:
3 mA (QI, II, III, IV)
5
:
5 mA (QI, II, III, IV)
6
:
5 mA (QI, II, III)
10 mA (QIV)
8
:
10 mA (QI, II, III)
20 mA (QIV)
Standard Triac:
4
:
25 mA (QI, II, III)
5
:
50 mA (QI, II, III)
Alternistor Triac:
H3
:
10 mA (QI, II, III)
H4
:
35 mA (QI, II, III)
PACKAGE TYPE
L : TO-220 Isolated
R : TO-220 Non-Isolated
N : TO-263 (D
2
PAK)
V : TO-251 (VPAK)
D : TO-252 (DPAK)
VOLTAGE RATING
40 :
400V
60 :
600V
80 :
800V
K0 :
1000V
LEAD FORM DIMENSIONS
xx : Lead Form Option
Q 60 06 L H4 56
DEVICE TYPE
L :
Sensitive Triac
Q
:
Triac or Alternistor
®
L6006V5
yxxxx
TO-252AA – (D Package)
TO-251AA – (V Package)
®