I-16
Noise
Filter
SNA series (1A,3A)
Ripple noise attenuation type for switch mode power supplies(DC)
SNA -03 -223 -O
Ordering information
1Model Name
2Rated Current
3Line to ground capacitor code:See table 1.1.
table1.1 Line to ground capacitor code
Code Line to ground capacitor (nominal value)
000 Not Provided
223 22000pF
4Options
D :DIN rail installation type
1 2 3 4
Features of SNA series (1A and 3A)
Circuit Diagram Derating Curve
50 60 70 80-20 -10 0 40-40 -30 71
20
0
100
80
60
40
Ambient Temperature [C]
Load Factor [%]
Ripple noise attenuation type for switch mode power supplies(DC)
-t50 VDC -Best filter for switch mode power supplies of
analog circuits
(ex. power supply filter for an operational amplifier)
*
The dimensions change when the option is set.
Refer to External view.
¡Expected life : 10 years
Specifications
No. Items SNA-01-223 SNA-03-223
Interfare:Connector
1 Rated Voltage DC[V] t50 (+Vin - COM-in, -Vin - COM-in)
2 Rated Current DC[A] 13
3 Test Voltage (Terminal-Mounting Plate) 500 VAC (Cutoff Current = 100mA), 1minute at room temperature and humidity
4 Isolation Resistance (Terminal-Mounting Plate) 500 VDC 50MW minute at room temperature and humidity
5D.C Resistance[mW]190 max 90 max
6 Operating temperature -40 to +71C (Refer to Derating Curve)
7 Operating humidity 20 to 95%RH (Non condensing)
8 Storage temperature/humidity -40 to +75C/20 to 95%RH (Non condensing)
9 Vibration 10 to 55Hz, 19.6m/s2(2G), 3min. Period, 1hour each X, Y and Z axis
10 Impact 196.1m/s2(20G), 11ms Once each X, Y and Z axis
11 Safety agency approvals UL60950-1, C-UL (CSA60950-1), EN60950-1
12 Case size (without projection) /Mass 52X35X93 mm (WXHXD) /130g max (Option : -D refer to external view)
IN OUT
CY
COM-out
+Vin +Vout
-Vout
COM-in
-Vin
Co
Co
+
+
CY
: Mounting PlateCY : Line to ground capacitor Co : Electrolytic capacitor
DIN rail installation type is option