2012-10-17 DURIS E 5 Datasheet Version 2.0 LUW JDSH.EC The DURIS E 5 combines high efficacy and a wide beam angle into a compact format (5.6 mm x 3.0 mm). This is key to homogeneous illumination applications where the DURIS E 5 never fails to impress with its performance on system level. Die DURIS E 5 kombiniert hohe Effizienz und einen weiten Abstrahlwinkel in einer kompakten Bauform (5.6 mm x 3.0 mm). Speziell fur Anwendungen mit besonders homogener Lichtverteilung kann die DURIS E 5 mit ihrer Leistung auf Systemebene uberzeugen. Features: Besondere Merkmale: * Package: white SMT package, colored diffused silicone resin * Technology: InGaN on Sapphire * Viewing angle at 50 % IV: 120 * Color: cool white; CRI (min.) = 80; CTR = 5700 K 6500 K; CRI (typ.) = 85 * Optical efficiency (typ.): 112 lm/W (cool white) at 6500 K * ESD - withstand voltage: up to 5 kV acc. to JESD22-A114-F * Lumen Maintenance: Test results according to IESNA LM-80 available * Gehausetyp: weies SMT Gehause, farbiger diffuser Silikon-Verguss * Technologie: InGaN on Sapphire * Abstrahlwinkel bei 50 % IV: 120 * Farbe: kaltwei; CRI (min.) = 80; CTR = 5700 K 6500 K; CRI (typ.) = 85 * Optischer Wirkungsgrad (typ.): 112 lm/W (kaltwei) bei 6500 K * ESD - Festigkeit: ESD-sicher bis 5 kV nach JESD22-A114-F * Lichtstromerhaltung: Testergebnisse nach IESNA LM-80 verfugbar Applications * * * * Anwendungen retrofits and fixtures task lights White goods channel letters 2012-10-17 * * * * 1 Retrofits Schreibtischleuchten Weie Ware Leuchtlettern Version 2.0 LUW JDSH.EC Ordering Information Bestellinformation Type Color Temperature Luminous Intensity 1) page 22 Ordering Code Typ Farbtemperatur Lichtstarke Bestellnummer 1) Seite 22 IF = 120 mA IV [mcd] LUW JDSH.EC-FSFU-5C8E-L1N2 6500 14000 ... 18000 Q65111A2714 LUW JDSH.EC-FSFU-5E8G-L1N2 5700 14000 ... 18000 Q65111A2683 Note: The above Type Numbers represent the order groups which include only a few brightness groups (see page for explanation). Only one group will be shipped on each packing unit (there will be no mixing of two groups on each packing unit). E. g. LUW JDSH.EC-FSFU-5E8G-L1N2 means that only one group FS, FT, FU will be shippable for any packing unit. In order to ensure availability, single brightness groups will not be orderable. In a similar manner for colors where color chromaticity coordinate groups are measured and binned, single groups will be shipped on any one packing unit. LUW JDSH.EC-FSFU-5E8G-L1N2 means that the device will be shipped within the specified limits as stated on page In order to ensure availability, single color chromaticity groups groups will not be orderable (see page for explanation). In a similar manner for colors where forward voltage groups are measured and binned, single forward voltage groups will be shipped on any packing unit. E. g. LUW JDSH.EC-FSFU-5E8G-L1N2 means that only one forward voltage group L1,L2,M1,M2,N1,N2 will be shippable. In order to ensure availability, single forward voltage groups will not be orderable (see page for explanation). Anm.: Die oben genannten Typbezeichnungen umfassen die bestellbaren Selektionen. Diese bestehen aus wenigen Helligkeitsgruppen (siehe Seite fur nahere Informationen). Es wird nur eine einzige Helligkeitsgruppe pro Verpackungseinheit geliefert. Z. B. LUW JDSH.EC-FSFU-5E8G-L1N2 bedeutet, dass in einer Verpackungseinheit nur eine der Helligkeitsgruppen FS, FT, FU enhalten ist. Um die Liefersicherheit zu gewahrleisten, konnen einzelne Helligkeitsgruppen nicht bestellt werden. Gleiches gilt fur die Farben, bei denen Farbortgruppen gemessen und gruppiert werden. Pro Verpackungseinheit wird nur eine Farbortgruppe geliefert. Z.B. LUW JDSH.EC-FSFU-5E8G-L1N2 bedeutet, dass in einer Verpackungseinheit nur eine der Farbortgruppen enthalten ist (siehe Seite fur nahere Informationen). LUW JDSH.EC-FSFU-5E8G-L1N2 bedeutet, dass das Bauteil innerhalb der auf Seite spezifizierten Grenzen geliefert wird. Um die Liefersicherheit zu gewahrleisten, konnen einzelne Farbortgruppen nicht bestellt werden. Gleiches gilt fur die LEDs, bei denen die Durchlassspannungsgruppen gemessen und gruppiert werden. Pro Verpackungseinheit wird nur eine Durchlassspannungsgruppe geliefert. Z. B. LUW JDSH.EC-FSFU-5E8G-L1N2 bedeutet, dass nach Durchlassspannungsgruppen gruppiert wird. In einer Verpackungseinheit ist nur eine der Durchlassspannungsgruppen L1,L2,M1,M2,N1,N2 enthalten (siehe Seite fur nahere Informationen). Um die Liefersicherheit zu gewahrleisten, konnen einzelne Durchlassspannungsgruppen nicht direkt bestellt werden. 2012-10-17 2 Version 2.0 LUW JDSH.EC Maximum Ratings Grenzwerte Parameter Symbol Values Unit Bezeichnung Symbol Werte Einheit Operating temperature range Betriebstemperatur Top -40 ... 85 C Storage temperature range Lagertemperatur Tstg -40 ... 100 C Junction temperature Sperrschichttemperatur Tj 110 C Forward current Durchlassstrom (TS = 25 C) IF 180 mA Surge current Stostrom (t <= 10 s; D = 0.005; TS = 25 C) IFM 300 mA Reverse voltage Sperrspannung (TS = 25 C) VR not designed for reverse operation 2012-10-17 3 V Version 2.0 LUW JDSH.EC Characteristics (TS = 25 C; IF = 120 mA) Kennwerte Parameter Symbol Values Unit Bezeichnung Symbol Werte Einheit Viewing angle at 50 % IV Abstrahlwinkel bei 50 % IV (typ.) 2 120 Forward voltage 2) page 22 Durchlassspannung 2) Seite 22 (min.) (typ.) (max.) VF VF VF 2.80 3.20 3.60 V V V IR not designed for reverse operation Reverse current Sperrstrom Real thermal resistance junction / solder point 3) page 22 Realer Warmewiderstand Sperrschicht / Lotpad (typ.) (max.) Rth JS real Rth JS real 41 64 K/W K/W (typ.) (max.) Rth JS el Rth JS el 33 51 K/W K/W 3) Seite 22 "Electrical" thermal resistance junction / solder point 3) page 22 "Elektrischer" Warmewiderstand Sperrschicht / Lotpad 3) Seite 22 (with efficiency e = 20 %) Note: Individual forward voltage groups see next page Anm.: Durchlassspannungsgruppen siehe nachste Seite 2012-10-17 4 Version 2.0 LUW JDSH.EC Brightness Groups Helligkeitsgruppen Group Luminous Intensity 1) page 22 Luminous Intensity 1) page 22 Luminous Flux Luminous Flux Gruppe Lichtstarke Lichtstarke Lichtstrom Lichtstrom (min.) Iv [mcd] (max.) Iv [mcd] (extrapolated min.) V [mlm] (extrapolated max.) V [mlm] 13000 14000 38200 41200 FR 1) Seite 22 1) Seite 22 FS 14000 15000 41200 44100 FT 15000 16400 44100 48200 FU 16400 18000 48200 52900 Note: The standard shipping format for serial types includes either a lower family group, an upper family group or a grouping of all individual brightness groups of only a few brightness groups. Individual brightness groups cannot be ordered. The extrapolated typical minimum and maximum values are calculated with a typical V/IV factor of 2.94. It is to consider that the 3 range of the V/IV factor is 2.8 - 3.1. Anm.: Die Standardlieferform von Serientypen beinhaltet entweder eine untere Familiengruppe, eine obere Familiengruppe oder eine Sammelgruppe, die aus nur wenigen Helligkeitsgruppen bestehen. Einzelne Helligkeitsgruppen sind nicht bestellbar. Der extrapolierte typische Minimum- und Maximumlichtstrom sind mit einem V/IV-Faktor von 2,94 berechnet. Mit der 3-Abweichung ergibt sich ein V/IV-Faktor von 2,8 bis 3,1. Forward Voltage Groups 2) page 22 Durchlassspannungsgruppe 2) Seite 22 Group Gruppe (min.) VF [V] (max.) VF [V] L1 2.80 2.90 L2 2.90 3.00 M1 3.00 3.10 M2 3.10 3.20 N1 3.20 3.30 N2 3.30 3.40 O1 3.40 3.50 O2 3.50 3.60 2012-10-17 5 Version 2.0 LUW JDSH.EC Chromaticity Coordinate Groups 4) page 22 Farbortgruppen 4) Seite 22 0.40 Cy 520 530 Cy 0.8 0.37 540 510 550 0.7 0.6 8G 0.36 560 570 E 490 0.33 6E 7C 6D 0.32 7G 7F 6G 6F 5G 5E + 5F 5D 5C 0.31 0.1 0.2 0.3 0.4 0.5 0.6 0.7 0.8 0.9 Cx 0.30 0.29 0.36 0.30 0.35 0 7E 7D 6C 480 470 460 450 0.1 8D 8C 0.31 0.2 0.34 8E 0.33 0.4 0.3 0.35 580 590 600 610 620 630 8F 0.32 500 0.5 0 0.39 0.38 0.34 0.9 Cx Color Chromaticity Groups Farbortgruppen 4) Seite 22 Group Gruppe 5C 6C 7C 2012-10-17 OHA04181 4) page 22 Cx Cy 0.3055 0.3177 0.3068 0.3113 0.3108 0.3229 0.3119 0.3162 0.3041 0.3240 0.3055 Group Gruppe 8D Cx Cy 0.3076 0.3430 0.3206 0.3462 0.3087 0.3363 0.3212 0.3389 0.3138 0.3492 0.3292 0.3461 0.3292 0.3539 0.3146 0.3422 0.3162 0.3282 0.3177 0.3170 0.3098 0.3296 0.3108 0.3229 0.3028 0.3304 0.3041 0.3240 0.3087 0.3098 5E Group Gruppe 7F Cy 0.3201 0.3534 0.3212 0.3206 0.3462 0.3216 0.3334 0.3291 0.3617 0.3221 0.3262 0.3292 0.3539 0.3154 0.3352 0.3293 0.3384 0.3162 0.3282 0.3294 0.3306 0.3363 0.3210 0.3408 0.3366 0.3369 0.3296 0.3216 0.3334 0.3369 0.3451 6E 6 8F Cx 5G Version 2.0 Group Gruppe 8C 5D 6D 7D 2012-10-17 LUW JDSH.EC Cx Cy 0.3015 0.3368 0.3028 0.3304 0.3076 0.3430 0.3087 0.3363 0.3108 0.3229 0.3119 0.3162 Group Gruppe 7E Cx Cy 0.3146 0.3422 0.3154 0.3352 0.3205 0.3481 0.3210 0.3408 0.3138 0.3492 0.3162 0.3146 0.3282 0.3200 0.3170 0.3212 0.3205 0.3098 0.3296 0.3217 0.3316 0.3108 0.3229 0.3222 0.3243 0.3154 0.3352 0.3293 8E 5F 6G Cx Cy 0.3292 0.3461 0.3293 0.3384 0.3369 0.3451 0.3373 0.3534 0.3292 0.3461 0.3422 0.3292 0.3539 0.3554 0.3373 0.3534 0.3481 0.3376 0.3616 0.3291 0.3617 0.3292 0.3539 0.3384 0.3376 0.3616 0.3294 0.3306 0.3379 0.3698 0.3212 0.3389 0.3162 0.3282 0.3087 0.3363 0.3098 0.3296 0.3217 0.3316 0.3146 0.3422 0.3292 0.3461 0.3154 0.3352 0.3293 0.3384 6F Group Gruppe 7 7G 8G Version 2.0 LUW JDSH.EC Group Name on Label Gruppenbezeichnung auf Etikett Example: FS-5E-L1 Beispiel: FS-5E-L1 Brightness Helligkeit Chromaticity Coordinate Farbort Forward Voltage Durchlassspannung FS 5E L1 Note: No packing unit / tape ever contains more than one group for each selection. Anm.: In einer Verpackungseinheit / Gurt ist immer nur eine Gruppe fur jede Selektion enthalten. 2012-10-17 8 Version 2.0 LUW JDSH.EC Relative Spectral Emission - V() = Standard eye response curve 5) page 22 , 1) page 22 Relative spektrale Emission - V() = spektrale Augenempfindlichkeit 5) Seite 22 , 1) Seite 22 Irel = f (); TS = 25 C; IF = 120 mA e rel 1,0 : V 0,9 0,8 0,7 0,6 0,5 0,4 0,3 0,2 0,1 0,0 400 450 500 550 600 650 700 750 [nm] Radiation Characteristics 5) page 22 Abstrahlcharakteristik 5) Seite 22 Irel = f (); TS = 25 C 40 30 20 10 0 50 OHL01660 1.0 0.8 0.6 60 0.4 70 0.2 80 0 90 100 1.0 2012-10-17 0.8 0.6 0.4 0 20 9 40 60 80 100 120 Version 2.0 LUW JDSH.EC Forward Current 5) page 22 Durchlassstrom 5) Seite 22 Relative Luminous Intensity 5) page 22 Relative Lichtstarke 5) Seite 22 IF = f (VF); TS = 25 C IV/IV(120 mA) = f(IF); TS = 25 C F [mA] 200 V V (120mA) 1.4 1.2 150 1.0 0.8 100 0.6 0.4 50 0.2 0 2.6 2.8 3.0 3.2 0.0 0 3.4 VF [V] Chromaticity Coordinate Shift 5) page 22 Farbortverschiebung 5) Seite 22 Cx, Cy = f(IF); TS = 25 C Cx, Cy 0.03 : Cx : Cy 0.02 0.01 0.00 -0.01 -0.02 -0.03 0 2012-10-17 50 100 150 200 F [mA] 10 50 100 150 200 F [mA] Version 2.0 LUW JDSH.EC Relative Forward Voltage 5) page 22 Relative Vorwartsspannung 5) Seite 22 Relative Luminous Intensity 5) page 22 Relative Lichtstarke 5) Seite 22 VF-VF (25C) [V] VF = VF - VF(25C) = f(Tj); IF = 120 mA IV/IV(25)C = f(Tj); IF = 120mA V 1,2 V (25C) 0,4 1,0 0,2 0,8 0,0 0,6 0,4 -0,2 0,2 -0,4 -40 -20 0 20 40 60 80 0,0 -40 -20 100 Tj [C] Chromaticity Coordinate Shift 5) page 22 Farbortverschiebung 5) Seite 22 Cx, Cy = f(Tj); IF = 120 mA 0,03 Cx; Cy : Cx : Cy 0,02 0,01 0,00 -0,01 -0,02 -0,03 -40 -20 2012-10-17 0 20 40 60 80 100 Tj [C] 11 0 20 40 60 80 100 Tj [C] Version 2.0 LUW JDSH.EC Max. Permissible Forward Current Max. zulassiger Durchlassstrom IF = f (T) F [mA] 180 160 140 120 100 80 60 40 20 0 0 20 40 60 80 100 TS [C] Permissible Pulse Handling Capability Zulassige Impulsbelastbarkeit IF = f(tp) Permissible Pulse Handling Capability Zulassige Impulsbelastbarkeit IF = f(tp) D: Duty cycle, TS = 25 C IF [A] 0.31 0.30 0.29 0.28 0.27 0.26 0.25 0.24 0.23 0.22 0.21 0.20 0.19 0.18 0.17 10-5 2012-10-17 D: Duty cycle, TS = 85 C IF [A] :D=1 : D = 0.5 : D = 0.2 : D = 0.1 : D = 0.05 : D = 0.02 : D = 0.01 : D = 0.005 0.30 :D=1 : D = 0.5 : D = 0.2 : D = 0.1 : D = 0.05 : D = 0.02 : D = 0.01 : D = 0.005 0.28 0.26 0.24 0.22 0.20 0.18 0.16 0.14 0.12 10-4 10-3 0.01 0.1 10-5 1 Pulse Time t{p} [s] 12 10-4 10-3 0.01 0.1 1 Pulse Time tp [s] Version 2.0 LUW JDSH.EC Package Outline 6) page 22 Mazeichnung 6) Seite 22 Approximate Weight: 36 mg Gewicht: 36 mg Function: P2 and thermal pad: Anode; P3: Cathode; P1&P4 not connected Funktion: P2 and Warmeleitpad: Anode; P3: Kathode; P1&P4 nicht verbunden 2012-10-17 13 Version 2.0 LUW JDSH.EC Recommended Solder Pad 6) page 22 Empfohlenes Lotpaddesign 6) Seite 22 2012-10-17 Reflow soldering Reflow-Loten 14 Version 2.0 LUW JDSH.EC Reflow Soldering Profile Reflow-Lotprofil Preconditioning: JEDEC Level 3 acc. to JEDEC S-STD-020-D OHA04525 300 C T 250 Tp 245 C 240 C tP 217 C 200 tL 150 tS 100 50 25 C 0 0 50 100 150 200 s 300 250 t OHA04612 Profile Feature Profil-Charakteristik Symbol Symbol Pb-Free (SnAgCu) Assembly Minimum Ramp-up rate to preheat*) 25 C to 150 C Time tS TSmin to TSmax tS 60 Ramp-up rate to peak*) TSmax to TP Recommendation Maximum 2 3 100 120 2 3 Unit Einheit K/s s K/s Liquidus temperature TL 217 Time above liquidus temperature tL 80 100 s Peak temperature TP 245 260 C Time within 5 C of the specified peak temperature TP - 5 K tP 20 30 s 3 6 K/s 10 Ramp-down rate* TP to 100 C 480 Time 25 C to TP All temperatures refer to the center of the package, measured on the top of the component * slope calculation DT/Dt: Dt max. 5 s; fulfillment for the whole T-range 2012-10-17 C 15 s Version 2.0 LUW JDSH.EC Method of Taping 6) page 22 Gurtung 6) Seite 22 2012-10-17 16 Version 2.0 LUW JDSH.EC Tape and Reel Gurtverpackung 12 mm tape with 2000 pcs. on 180 mm reel W1 D0 P0 A N F W E 13.0 0.25 P2 Label P1 Direction of unreeling Direction of unreeling W2 Gurtvorlauf: 400 mm Leader: 400 mm Gurtende: Trailer: 160 mm 160 mm OHAY0324 Tape dimensions in mm (inch) Tape dimensions in mm (inch) W P0 P1 P2 D0 E F 12 +0.3/-0.1 4 0.1 (0.157 0.004) 4 0.1 (0.157 0.004) or 8 0.1 (0.315 0.004) 2 0.05 (0.079 0.002) 1.5 0.1 (0.059 + 0.004) 1.75 0.1 (0.069 0.004) 5.5 0.05 (0.217 0.002) Reel dimensions in mm (inch) Reel dimensions in mm (inch) A W Nmin W1 W2max 180 (7) 12 (0.472) 60 (2.362) 12.4 + 2 (0.488 + 0.079) 18.4 (0.724) 2012-10-17 17 Version 2.0 LUW JDSH.EC Barcode-Product-Label (BPL) Barcode-Produkt-Etikett (BPL) OSRAM Opto BIN1: XX-XX-X-XXX-X LX XXXX Semiconductors RoHS Compliant (6P) BATCH NO: 1234567890 ML Temp ST 2 260 C R (1T) LOT NO: 1234567890 (9D) D/C: 1234 Pack: R18 DEMY 022 B_R999_1880.1642 R (X) PROD NO: 123456789(Q)QTY: 9999 (G) GROUP: XX-XX-X-X OHA04563 Dry Packing Process and Materials Trockenverpackung und Materialien Moisture-sensitive label or print L VE LE l k, see labe code blan If bar ). (RH . RH idity hum 0% e tive C/6 red kag S rela 30 s pac _ < infra IVE of TOR rs tain 90% to ak SIT rs < ns ed (pe UC e). or rs con Hou SEN rs Hou ND and ject ditio cod C, 72 sing Hou e 5 bag E 48 C sub Hou con s UR ICO ces 24 6 dat 40 be time C ory ThiISTSEM r pro < time r 23 time at t will C). l with fact r ent MO . Floo time TO at at r Floo l ths tha tica d ival ure OP Floo 4 if: rea w Floo labe mon iden 5 ced equ el ices g, n e 5a is el belo or 24 pro 6 Lev e dev : ntin el whe cod e , w, e Lev el see e bag Lev l dat mou bak bar ned stur e Lev reflo 10% led stur e time sea for ore> ope e Moi r see stur k, is . sea is has k, Moi stur bef d 033 Moi in Floo RH blan Moi or-p blan in bag Car ing, r TD(if life . If r lf J-S thisvapp. d with 10%bak or Yea _ eks rs < r w, icat met 1 Yea tem d, She at nte uire not > y 1 WeHou DEC Afte Ind 4 uire reflo is bod Mou red req /JE time 168 req : 2b r a) Sto ices idity time is IPC r or time b) ned Floo r Hum ing ce time Dev 2a e r Floo a) ope 3. b) bakren Floo 1 l dat Floo If 2 refe time el 4. 2a el sea 3 Lev el and e Lev el Bag e e Lev stur e Lev Dat stur e Moi stur Moi stur Moi Moi C 1. U A TI Barcode label N O O S R A M 2. Humidity indicator Barcode label Please check the HIC immidiately after bag opening. Discard if circles overrun. Avoid metal contact. Do not eat. Comparator check dot WET If wet, examine units, if necessary bake units 15% If wet, examine units, if necessary bake units 10% 5% If wet, parts still adequately dry. change desiccant Humidity Indicator MIL-I-8835 AM Desiccant OSR OHA00539 Note: Moisture-sensitive product is packed in a dry bag containing desiccant and a humidity card. Regarding dry pack you will find further information in the internet and in the Short Form Catalog in chapter "Tape and Reel" under the topic "Dry Pack". Here you will also find the normative references like JEDEC. Anm.: Feuchteempfindliche Produkte sind verpackt in einem Trockenbeutel zusammen mit einem Trockenmittel und einer Feuchteindikatorkarte. Bezuglich Trockenverpackung finden Sie weitere Hinweise im Internet und in unserem Short Form Catalog im Kapitel "Gurtung und Verpackung" unter dem Punkt "Trockenverpackung". Hier sind Normenbezuge, unter anderem ein Auszug der JEDEC-Norm, enthalten. 2012-10-17 18 Version 2.0 LUW JDSH.EC Transportation Packing and Materials Kartonverpackung und Materialien Barcode label MY DE 8 Q- 1 R1 lti LS TO Y T6 PL 76 1+ Mu POU GR 44 D/C ) (9D 4 20 23 Y: QT H1 TC BA 3G ) : 12 (6P 00 : 01 998 021 210 O Se SR mi AM co nd O uc pt to o H rs NO : ). 5 14 2 110 0 (X) PR OD NO : (1T ) LO T NO see labe (G) l k, N O TI U A C (Q) L VE LE code (RH blan If y bar . idit RH hum 60% e tive d C/ kag rela are 30 E S s _ < infr pac OR of tainITIV 90% to ak urs CT < e). or urs ted (pe ons con NS Ho g urs SE DU Ho and jec diti cod C, 72 sin Ho urs e 5 bag E ON 48 C sub e Ho con s UR ces 24 6 dat e MIC 40 be tim C e ThiISTSE pro < tory tim . or t with 23 tim e at t will C) or fac MO . Flo al len tim TO s at or at Flo d or iva ure el nth s tha OP ntic Flo 4 if: rea Flo , lab ow mo ice equ ide 5 ced el e 5a is el ingen bel or 24 pro 6 Lev e dev, : el cod e , unt wh Lev el re ow see bag Lev l dat re mo bak e bar ned Lev refl istu 10% re tim sea for istu ore> re ope e Mo see 3 istu is or . sea is has Mo nk, bef istu nk, Flo , rd -03 Mo in RH bla Mo or-p bla in bag ingCa r TD life (if If with t. r lf vapp. 10%baktor J-S this Yea , _ eks < r ed ica med, C 1 urs Yea tem She ow at uire not > y 1 WeHo unt DE Afte Ind 1. e 4 uire refl red req 2. bod Mo e ity is /JE tim s 168 req : e 2b a) Sto tim or mid is IPC tim e vice or b) or ned Flo Hu tim ing ce or De e 2a Flo a) ope or 3. b) bakren Flo e 1 l dat Flo If 2 el refe tim 2a 4. el sea 3 Lev el and Lev el re Bag te Lev re Lev istu Da re istu re Mo istu Mo istu Mo Mo P: Muster ED Bin Bin 1: Bin 2: P-1 3: Q-1 -20 ML -20 2 Tem 2a 220 3 240 p ST Ad 260 C R C R0 diti R ona C RT PA 77 l TE CK VA XT R: Barcode label MY DE 8 1 Q- R1 lti LS TO Y T6 PL 76 1+ P- Mu 8 : 01 O SR AM 99 D/C ) 21 00 (9D 21 : 4 20 00 Y: O H1 23 TC ) (6P (Q) (X) PR OD NO : (1T ) 11 00 LO T 14 2 NO 5 : 12 BA 3G QT Se SR m A ico M nd O uc pt to o H rs NO 44 (G) GR OU P: Muster ED Bin Bin 1: Bin 2: P-1 3: Q-1 -20 ML -20 2 Te 2a 220 mp 3 240 ST Ad 260 C R C R0 diti R ona C RT PA 77 l TE CK VA XT R: led Packing Sealing label Dimensions of transportation box in mm (inch) Width / Breite Length / Lange Height / Hohe 195 5 (7.677 0.1968) 195 5 (7.677 0.1968) 30 5 (1.181 0.196) 2012-10-17 19 OHA02044 Version 2.0 LUW JDSH.EC Notes Hinweise The evaluation of eye safety occurs according to the standard IEC 62471:2006 ("photobiological safety of lamps and lamp systems"). Within the risk grouping system of this CIE standard, the LED specified in this data sheet fall into the class Low risk (exposure time 100 s). Under real circumstances (for exposure time, eye pupils, observation distance), it is assumed that no endangerment to the eye exists from these devices. As a matter of principle, however, it should be mentioned that intense light sources have a high secondary exposure potential due to their blinding effect. As is also true when viewing other bright light sources (e.g. headlights), temporary reduction in visual acuity and afterimages can occur, leading to irritation, annoyance, visual impairment, and even accidents, depending on the situation. Die Bewertung der Augensicherheit erfolgt nach dem Standard IEC 62471:2006 ("photobiological safety of lamps and lamp systems"). Im Risikogruppensystem dieser CIE- Norm erfullen die in diesem Datenblatt angegebenen LEDs folgende Gruppenanforderung - Low risk (Expositionsdauer 100 s). Unter realen Umstanden (fur Expositionsdauer, Augenpupille, Betrachtungsabstand) geht damit von diesen Bauelementen keinerlei Augengefahrdung aus. Grundsatzlich sollte jedoch erwahnt werden, dass intensive Lichtquellen durch ihre Blendwirkung ein hohes sekundares Gefahrenpotenzial besitzen. Nach einem Blick in eine helle Lichtquelle (z.B. Autoscheinwerfer), kann ein temporar eingeschranktes Sehvermogen oder auch Nachbilder zu Irritationen, Belastigungen, Beeintrachtigungen oder sogar Unfallen fuhren. Subcomponents of this LED are silverplated. Silver is discoloring when being exposed to environments containing high concentrations of aggressive substances. Corroded silver may lead to a worsening of the optical performance of the LED and can in the worst case lead to a failure of the LED. Do not expose this LED to aggressive atmospheres. Note, that corrosive gases may as well be emitted from materials close to the LED in the final product. Einzelkomponenten dieser LED sind silberbeschichtet. Silberoberflachen werden durch korrosive Substanzen verandert. Korrodiertes Silber kann zu einer Verschlechterung der optischen Eigenschaften und im schlimmsten Fall zum Ausfall der LED fuhren. Diese LED darf aggressiven Bedingungen nicht ausgesetzt werden. Es ist zu beachten, dass korrosive Gase auch von Materialien emittiert werden konnen, die sich im Endprodukt in unmittelbarer Umgebung der LED befinden. 2012-10-17 20 Version 2.0 LUW JDSH.EC Date of Change: 2012-02-15 Revision Date: 2012-10-17 Version Subjects Date of change 2.0 OS-PCN-2012-006-A 2012-02-15 1.1 updated layout Disclaimer Disclaimer Attention please! The information describes the type of component and shall not be considered as assured characteristics. Terms of delivery and rights to change design reserved. Due to technical requirements components may contain dangerous substances. For information on the types in question please contact our Sales Organization. If printed or downloaded, please find the latest version in the Internet. Packing Please use the recycling operators known to you. We can also help you - get in touch with your nearest sales office. By agreement we will take packing material back, if it is sorted. You must bear the costs of transport. For packing material that is returned to us unsorted or which we are not obliged to accept, we shall have to invoice you for any costs incurred. Components used in life-support devices or systems must be expressly authorized for such purpose! Critical components* may only be used in life-support devices** or systems with the express written approval of OSRAM OS. Bitte beachten! Lieferbedingungen und Anderungen im Design vorbehalten. Aufgrund technischer Anforderungen konnen die Bauteile Gefahrstoffe enthalten. Fur weitere Informationen zu gewunschten Bauteilen, wenden Sie sich bitte an unseren Vertrieb.Falls Sie diese Datenblatt ausgedruckt oder heruntergeladen haben, finden Sie die aktuellste Version im Internet. Verpackung Benutzen Sie bitte die Ihnen bekannten Recyclingwege. Wenn diese nicht bekannt sein sollten, wenden Sie sich bitte an das nachstgelegene Vertriebsburo. Wir nehmen das Verpackungsmaterial zuruck, falls dies vereinbart wurde und das Material sortiert ist. Sie tragen die Transportkosten. Fur Verpackungsmaterial, das unsortiert an uns zuruckgeschickt wird oder das wir nicht annehmen mussen, stellen wir Ihnen die anfallenden Kosten in Rechnung. Bauteile, die in lebenserhaltenden Apparaten und Systemen eingesetzt werden, mussen fur diese Zwecke ausdrucklich zugelassen sein! Kritische Bauteile* durfen in lebenserhaltenden Apparaten und Systemen nur dann eingesetzt werden, wenn ein schriftliches Einverstandnis von OSRAM OS vorliegt. *) A critical component is a component used in a life-support device or system whose failure can reasonably be expected to cause the failure of that life-support device or system, or to affect its safety or the effectiveness of that device or system. **) Life support devices or systems are intended(a) to be implanted in the human body,or(b) to support and/or maintain and sustain human life.If they fail, it is reasonable to assume that the health and the life of the user may be endangered. *) Ein kritisches Bauteil ist ein Bauteil, das in lebenserhaltenden Apparaten oder Systemen eingesetzt wird und dessen Defekt voraussichtlich zu einer Fehlfunktion dieses lebenserhaltenden Apparates oder Systems fuhren wird oder die Sicherheit oder Effektivitat dieses Apparates oder Systems beeintrachtigt. **) Lebenserhaltende Apparate oder Systeme sind fur (a) die Implantierung in den menschlichen Korper oder (b) fur die Lebenserhaltung bestimmt. Falls Sie versagen, kann davon ausgegangen werden, dass die Gesundheit und das Leben des Patienten in Gefahr ist. 2012-10-17 21 Version 2.0 LUW JDSH.EC Glossary Glossar 1) Brightness: Brightness groups are tested at a current pulse duration of 25 ms and a tolerance of 11%. 1) Helligkeit: Helligkeitswerte werden mit Stromeinpragedauer von 25 ms und Genauigkeit von 11% ermittelt. 2) Forward Voltage: Forward voltages are tested at a current pulse duration of 1 ms and a tolerance of 0.1 V. 2) Durchlassspannung: Spannungswerte werden mit einer Stromeinpragedauer von 1 ms und einer Genauigkeit von 0,1 V ermittelt. 3) Thermal Resistance: Rth max based on statistic values (6) 3) Warmewiderstand: Rth statistischen Werten (6) 4) Chromaticity coordinate groups: Chromaticity coordinate groups are tested at a current pulse duration of 25 ms and a tolerance of 0.01. 4) Farbortgruppen: Farbortgruppen werden mit einer Stromeinpragedauer von 25 ms und einer Genauigkeit von 0,01 ermittelt 5) Typical Values: Due to the special conditions of the manufacturing processes of LED, the typical data or calculated correlations of technical parameters can only reflect statistical figures. These do not necessarily correspond to the actual parameters of each single product, which could differ from the typical data and calculated correlations or the typical characteristic line. If requested, e.g. because of technical improvements, these typ. data will be changed without any further notice. 5) Typische Werte: Wegen der besonderen Prozessbedingungen bei der Herstellung von LED konnen typische oder abgeleitete technische Parameter nur aufgrund statistischer Werte wiedergegeben werden. Diese stimmen nicht notwendigerweise mit den Werten jedes einzelnen Produktes uberein, dessen Werte sich von typischen und abgeleiteten Werten oder typischen Kennlinien unterscheiden konnen. Falls erforderlich, z.B. aufgrund technischer Verbesserungen, werden diese typischen Werte ohne weitere Ankundigung geandert. 6) Tolerance of Measure: Dimensions are specified as follows: mm (inch). 6) Matoleranz: Mae angegeben: mm (inch). Published by OSRAM Opto Semiconductors GmbH Leibnizstrae 4, D-93055 Regensburg www.osram-os.com (c) All Rights Reserved. 2012-10-17 22 max werden basiert wie einer einer auf folgt