63
MED-16x1-1/8 STANDARD COIL RATING
VOLTAGE CONTINUOUS RESISTANCE INTERMITTENT RESISTANCE PULSE RESISTANCE
DUTY ±5% DUTY ±5% DUTY ±5%
PULL TYPE UNITS P/N P/N P/N
6 VDC 53754-80 4.7 OHMS 53754-86 1.9 OHMS 53754-92 .47 OHMS
12 VDC 53754-81* 19 OHMS 53754-87* 7.5 OHMS 53754-93 1.9 OHMS
24 VDC 53754-82* 75 OHMS 53754-88* 30 OHMS 53754-94 7.5 OHMS
115 VDC 53754-84 1900 OHMS 53754-90 750 OHMS 53754-96 190 OHMS
PUSH TYPE UNITS
6 VDC 53759-80 4.7 OHMS 53759-86 1.9 OHMS 53759-92 .47 OHMS
12 VDC 53759-81 19 OHMS 53759-87 7.5 OHMS 53759-93 1.9 OHMS
24 VDC 53759-82 75 OHMS 53759-88 30 OHMS 53759-94 7.5 OHMS
115 VDC 53759-84 1900 OHMS 53759-90 750 OHMS 53759-96 190 OHMS
*Black Items Are Normally Stocked.
*Blue Items Are Non Stock – Minimum Quantity May Be Required.
MED 16x1-1/8 TYPICAL FORCE CURVES (CLASS A)
Standard intermittent duty cycle at nominal voltage is one (1) minute “ON” and
three (3) minutes “OFF”. Standard pulse duty cycle is 100 milliseconds “ON”
and 900 milliseconds “OFF”
NOTE: Cold Force @ 25°C (77°F) Coil Temperature.
NOTE: Hot Force @ 130°C (266°F) Coil Temperature. NOTE: Approx. 36 sq. in. Heat Sink Required.
DC CONTINUOUS DUTY 8 WATTS
DC PULSE DUTY 77 WATTS
DC INTERMITTENT DUTY 19 WATTS