The NXI110 non-isolated dc-dc converters are designed to meet
the exceptionally fast transient response requirements of today’s
microprocessors and fast switching logic in a compact size at a
very affordable price. Advanced Circuit techniques, component
selection and placement optimization, state-of-the-art thermal
packaging, and Surface Mount Technologies provide a high power
density, highly reliable, and very precise voltage regulation system
for advanced microprocessors. Multi-phase power conversion
techniques allow the NXI converters to lead the industry with
regard to conversion efficiency without adding unneccesary
complexity. VRM9.0 specification compliant without the need for
expensive external components. On board active current sharing
circuit guarantees the current sharing specification is met both
during both static and dynamic load conditions
Embedded Power for
Business-Critical Continuity
NXI110 Series
Single output,
5 Bit Selectable
(Non-Isolated)
Special Features
Meets VRM9.0 specification
High efficiency: 84% typical @
Vin = 12 V, Vout = 1.7 V,
Iout = 60 A
Multi-phase power conversion
Microprocessor voltage
identification input
5 Bit VID input
- 1.10 Vdc to 1.85 Vdc in
25 mV steps
Remote enable pin
Power good signal
True double ended differential
remote sense
Democratic current sharing,
no need for master/slave
configuration
Up to 50 A/µsec load transient
no load to full load, recovery
within 50 µsec
Overcurrent and short circuit
protection
Overvoltage protection with on
board fuse
Vertical plug-in to standard
motherboard connector
No minimum load requirement
Available RoHS compliant
2 year warranty
Total Power: 110W
Input Voltage: 11 - 13.2VDC
# of Outputs: Single
Rev.03.23.07
nxi110
1 of 4
EOL
EOL
Rev.03.23.07
nxi110
2 of 4
Embedded Power for
Business-Critical Continuity
All specifications are typical at nominal input, full load at 25°C unless otherwise stated.
Specifications
GENERAL SPECIFICATIONS
Efficiency 1V7, 1V85 output @ 60 A 84%
1V10 output @ 60 A 76%
Switching frequency Fixed (See Note 3) 900 kHz
Standards 94V-0 Flammability rating
)zo 46.2( g 57thgieW
MTBF Bellcore TR-332 2,000,000 hours
)4 etoN eeS(rotcennoc gnitaM
ENVIRONMENTAL SPECIFICATIONS
Maximum temperature Operating 5 ˚C/10 min.
shock
Temperature shock Operating 10 ˚C/hour
Non-operating 20 ˚C/hour
HR %58gnitarepOytidimuH
HR %59egarotS
Altitude Operating 10,000 feet max.
Storage 50,000 feet max.
Shock Operational and 50 G 11 ms
non-operational half sine wave
Vibration Operational and 0.02 G2/Hz max.
(See Note 5) non-operational
Electrostatic discharge Operating (See Note 6) ESD 15 kV
Non-operating ESD 25 kV
Thermal performance Operating ambient 0 to +60 °C
(See Note 7) temperature
OUTPUT SPECIFICATIONS
elbat eeSytilibatsujda egatloV
%8.0±tuoVycarucca tniop teS
Ripple and noise 20 MHz bandwidth 15 mV pk-pk
(See Note 1)
Transient response (See Note 2) 125 mV
sµ 05emit gnilttes .ved kaep
suounitnoCnoitcetorp tiucric-trohS
automatic recovery
INPUT SPECIFICATIONS
Input voltage range 12 Vin nominal 11.0-13.2 Vdc
Am 003daol oNtnerruc tupnI
Remote OFF 40 mA max.
.pyt V 8.01egatlov NO nrut OLVU
.pyt V 5.9egatlov FFO nrut OLVU
Start-up time Nominal line 10 ms
Active high remote ON/OFF
tupni- ot .feRytilibitapmoc cigoL
cdV 0.5egatlov tiucric-nepONO
.xam cdV 8.0FFO
EOL
Rev.03.23.07
nxi110
3 of 4
Embedded Power for
Business-Critical Continuity
Specifications Contd.
TABLE 1: PIN CONNECTIONS
PIN NO. FUNCTION PIN NO. FUNCTION
1 Vin+ 32 Vo-
2 Vin+ 33 Vo+
3 Vin+ 34 Vo-
4 Vin+ 35 Vo+
5 Reserved 36 Vo-
6 Key 37 Vo+
7 VID3 38 Vo-
8 VID1 39 Vo+
9 Reserved 40 Vo-
10 PWRGD 41 Vo+
11 Vo sen- 42 Vo-
12 Reserved 43 Vo+
13 Vo- 44 Vo-
14 Vo+ 45 Vo+
15 Vo- 46 Vo-
16 Vo+ 47 Vo+
17 Vo- 48 Vo-
18 Vo+ 49 Vo+
19 Vo- 50 Vo+
20 Vo+ 51 Reserved
21 Vo- 52 Vo sen+
22 Vo+ 53 OUTEN
23 Vo- 54 Ishare
24 Vo+ 55 VID0
25 Vo- 56 VID2
26 Vo+ 57 VID4
27 Vo- 58 VRM-pres
28 Vo+ 59 Vin-
29 Vo- 60 Vin-
30 Vo+ 61 Vin-
31 Vo- 62 Vin-
Notes
115 mV pk-pk ripple with no external output filtering.
Vin = 12 V, Vout = 1.6 V, Iout = 60 A.
2125 mV peak deviation when slewing load from no load to full load at 50
A/µsec. Oscon type low impedance caps required across output.
3Each phase operates at a fixed 225 kHz. Effective fundamental output
frequency is 900 kHz / 4 phases each at 225 kHz interleaved.
4Recommended mating connector is AMP 1364125-1 or equivalent.
5From 5 Hz to 20 Hz, maintaining 0.02 G2/Hz from 20 Hz to 500 Hz, all axes.
6Initilization level; ESD event shall cause no out-of-regulation conditions.
7Requires 400 LFM forced air over the converter. Ensure the thermal reference
point (see figure 2) is kept below 95 ºC to maintain the reliability of the
converter.
8The ‘Y’ suffix indicates that these parts are TSE RoHS 5/6 (non Pb-free)
compliant.
9NOTICE: Some models do not support all options. Please contact your local
Artesyn representative or use the on-line model number search tool at
http://www.artesyn.com/powergroup/products.htm to find a suitable
alternative.
TABLE 2 : VOLTAGE IDENTIFICATION (VID) CODES
VID4 VID3 VID2 VID1 VID0 VDAC
1 1 1 1 1 Off
1 1 1 1 0 1.100
1 1 1 0 1 1.125
1 1 1 0 0 1.150
1 1 0 1 1 1.175
1 1 0 1 0 1.200
1 1 0 0 1 1.225
1 1 0 0 0 1.250
1 0 1 1 1 1.275
1 0 1 1 0 1.300
1 0 1 0 1 1.325
1 0 1 0 0 1.350
1 0 0 1 1 1.375
1 0 0 1 0 1.400
1 0 0 0 1 1.425
1 0 0 0 0 1.450
0 1 1 1 1 1.475
0 1 1 1 0 1.500
0 1 1 0 1 1.525
0 1 1 0 0 1.550
0 1 0 1 1 1.575
0 1 0 1 0 1.600
0 1 0 0 1 1.625
0 1 0 0 0 1.650
0 0 1 1 1 1.675
0 0 1 1 0 1.700
0 0 1 0 1 1.725
0 0 1 0 0 1.750
0 0 0 1 1 1.775
0 0 0 1 0 1.800
0 0 0 0 1 1.825
0 0 0 0 0 1.850
INPUT NOMINAL OUTPUT NOMINAL OUTPUT TYPICAL MODEL
REBMUNYCNEICIFFETNERRUCEGATLOVEGATLOV (8,9)
YC8V1P21-011IXN%48A 062 elbaT eeScdV 21
Embedded Power for
Business-Critical Continuity
Rev.03.23.07
nxi110
4 of 4
Emerson Network Power and the Emerson
Network Power logo are trademarks and
service marks of Emerson Electric Co.
©2007 Emerson Electric Co.
Emerson Network Power.
The global leader in enabling
business-critical continuity.
EmersonNetworkPower. com
AC Power
Connectivity
DC Power
Embedded Power
Inbound Power
Integrated Cabinet Solutions
Outside Plant
Precision Cooling
Site Monitoring and Services
Americas
5810 Van Allen Way
Carlsbad, CA 92008
USA
Telephone: +1 760 930 4600
Facsimile: +1 760 930 0698
Europe (UK)
Waterfront Business Park
Merry Hill, Dudley
West Midlands, DY5 1LX
United Kingdom
Telephone: +44 (0) 1384 842 211
Facsimile: +44 (0) 1384 843 355
Asia (HK)
16th - 17th Floors, Lu Plaza
2 Wing Yip Street, Kwun Tong
Kowloon, Hong Kong
Telephone: +852 2176 3333
Facsimile: +852 2176 3888
For global contact, visit:
www.powerconversion.com
technicalsupport@powerconversion.com
While every precaution has been taken to ensure
accuracy and completeness in this literature, Emerson
Network Power assumes no responsibility, and disclaims
all liability for damages resulting from use of this
information or for any errors or omissions.
3.800 (96.520)
3.600 (91.440)
3.186 (80.924)
3.000 (76.200)0.093 (2.362)
0.307 (7.798)
1.122
(28.499)
REF
2.615
(66.421)
REF
2.300 (58.420)
0.300 (7.620)
0.310 (7.874)
11 32-62 1-31
6 No Contact
12
31
3262
1
0.042
(1.067)
KEY
DIMENSIONS IN INCHES (MM)
0.425 (10.795) 0.425 (10.795)
0.425 (10.795)
KEEP OUT
AREA
0.610 (15.494)
0.250 (6.350) MAX
0.063 (1.600) THK FR-4 DBL-SIDED
CIRCUIT BOARD W/GOLD-PLATED
(30u") CONNECTOR FINGERS
0.563 (14.300) MAX
0.54 (13.72)
1.075 (27.305)
0.100 (2.540) TYP
COMP CLEAR
Figure 2:
Thermal Reference Point (TRP) -
Monitor Tab Indicated
Figure 1: Mechanical Drawing
TRP
Mechanical Notes
1All dimensions in INCHES (mm).
EOL