Embedded Power for Business-Critical Continuity Rev.03.23.07 nxi110 1 of 4 NXI110 Series Single output, 5 Bit Selectable (Non-Isolated) Total Power: 110W Input Voltage: 11 - 13.2VDC # of Outputs: Single Special Features * Meets VRM9.0 specification High efficiency: 84% typical @ Vin = 12 V, Vout = 1.7 V, Iout = 60 A * Multi-phase power conversion * Microprocessor voltage identification input * 5 Bit VID input * - 1.10 Vdc to 1.85 Vdc in 25 mV steps * Remote enable pin * Power good signal * True double ended differential remote sense * Democratic current sharing, no need for master/slave configuration * Up to 50 A/sec load transient no load to full load, recovery within 50 sec * Overcurrent and short circuit protection * Overvoltage protection with on board fuse * Vertical plug-in to standard motherboard connector * No minimum load requirement * Available RoHS compliant * 2 year warranty The NXI110 non-isolated dc-dc converters are designed to meet the exceptionally fast transient response requirements of today's microprocessors and fast switching logic in a compact size at a very affordable price. Advanced Circuit techniques, component selection and placement optimization, state-of-the-art thermal packaging, and Surface Mount Technologies provide a high power density, highly reliable, and very precise voltage regulation system for advanced microprocessors. Multi-phase power conversion techniques allow the NXI converters to lead the industry with regard to conversion efficiency without adding unneccesary complexity. VRM9.0 specification compliant without the need for expensive external components. On board active current sharing circuit guarantees the current sharing specification is met both during both static and dynamic load conditions L O E Embedded Power for Business-Critical Continuity Specifications Rev.03.23.07 nxi110 2 of 4 All specifications are typical at nominal input, full load at 25C unless otherwise stated. OUTPUT SPECIFICATIONS GENERAL SPECIFICATIONS Voltage adjustabilit y See table Set point accuracy Vout Ripple and noise (See Note 1) 20 MHz bandwidth Transient response peak dev. settling time (See Note 2) Shor t-circuit protection 1V7, 1V85 output @ 60 A 1V10 output @ 60 A Switching frequency Fixed (See Note 3) Standards 94V-0 Flammability rating L O E 125 mV 50 s Continuous automatic recovery INPUT SPECIFICATIONS Weight MTBF 84% 76% 900 kHz 75 g (2.64 oz) Bellcore TR-332 Mating connector 2,000,000 hours (See Note 4) ENVIRONMENTAL SPECIFICATIONS Input voltage range 12 Vin nominal Input current No load Remote OFF UVLO turn ON voltage UVLO turn OFF voltage Start-up time 0.8% 15 mV pk-pk Efficiency 11.0-13.2 Vdc 300 mA 40 mA max. 10.8 V t yp. 9.5 V t yp. Nominal line Active high remote ON/OFF Logic compatibilit y ON Open-circuit voltage OFF Maximum temperature shock Operating Temperature shock Operating Non-operating Humidit y Operating Storage 85% RH 95% RH Altitude Operating Storage 10,000 feet max. 50,000 feet max. Shock Operational and non-operational 50 G 11 ms half sine wave Vibration (See Note 5) Operational and non-operational 0.02 G2/Hz max. Electrostatic discharge Operating (See Note 6) Non-operating Thermal performance (See Note 7) Operating ambient temperature 10 ms Ref. to -input 5.0 Vdc 0.8 Vdc max. 5 C/10 min. 10 C/hour 20 C/hour ESD 15 kV ESD 25 kV 0 to +60 C Embedded Power for Business-Critical Continuity Specifications Contd. Rev.03.23.07 nxi110 3 of 4 INPUT VOLTAGE NOMINAL OUTPUT VOLTAGE NOMINAL OUTPUT CURRENT TYPICAL EFFICIENC Y MODEL NUMBER (8,9) 12 Vdc See Table 2 60 A 84% NXI110-12P1V8CY Notes 1 2 3 4 5 15 mV pk-pk ripple with no external output filtering. Vin = 12 V, Vout = 1.6 V, Iout = 60 A. 125 mV peak deviation when slewing load from no load to full load at 50 A/sec. Oscon type low impedance caps required across output. Each phase operates at a fixed 225 kHz. Effective fundamental output frequency is 900 kHz / 4 phases each at 225 kHz interleaved. Recommended mating connector is AMP 1364125-1 or equivalent. From 5 Hz to 20 Hz, maintaining 0.02 G2/Hz from 20 Hz to 500 Hz, all axes. 6 7 8 9 Initilization level; ESD event shall cause no out-of-regulation conditions. Requires 400 LFM forced air over the converter. Ensure the thermal reference point (see figure 2) is kept below 95 C to maintain the reliability of the converter. The `Y' suffix indicates that these parts are TSE RoHS 5/6 (non Pb-free) compliant. NOTICE: Some models do not support all options. Please contact your local Artesyn representative or use the on-line model number search tool at http://www.artesyn.com/powergroup/products.htm to find a suitable alternative. TABLE 1: PIN CONNECTIONS PIN NO. FUNCTION TABLE 2 : VOLTAGE IDENTIFICATION (VID) CODES PIN NO. FUNCTION 1 Vin+ 32 Vo- 2 Vin+ 33 Vo+ 3 Vin+ 34 Vo- 4 Vin+ 35 Vo+ 5 Reserved 36 Vo- 6 Key 37 Vo+ 7 VID3 38 Vo- 8 VID1 39 Vo+ 9 Reserved 40 Vo- VID4 VID3 VID2 VID1 VID0 1 1 1 1 1 Off 1 1 1 1 0 1.100 1 1 1 0 1 1.125 1 1 1 0 0 1.150 1 1 0 1 1 1.175 1 1 0 1 0 1.200 1 1 0 0 1 1.225 1 1 0 0 0 1.250 1 0 1 1 1 1.275 1 0 1 1 0 1.300 1 0 1 0 1 1.325 1 0 1 0 0 1.350 1 0 0 1 1 1.375 1 0 0 1 0 1.400 1 0 0 0 1 1.425 1 0 0 0 0 1.450 0 1 1 1 1 1.475 0 1 1 1 0 1.500 L O E VDAC 10 PWRGD 41 Vo+ 11 Vo sen- 42 Vo- 12 Reserved 43 Vo+ 13 Vo- 44 Vo- 14 Vo+ 45 Vo+ 15 Vo- 46 Vo- 16 Vo+ 47 Vo+ 17 Vo- 48 Vo- 18 Vo+ 49 Vo+ 0 1 1 0 1 1.525 19 Vo- 50 Vo+ 0 1 1 0 0 1.550 20 Vo+ 51 Reserved 0 1 0 1 1 1.575 21 Vo- 52 Vo sen+ 0 1 0 1 0 1.600 22 Vo+ 53 OUTEN 0 1 0 0 1 1.625 23 Vo- 54 Ishare 0 1 0 0 0 1.650 24 Vo+ 55 VID0 0 0 1 1 1 1.675 0 1 1 0 1.700 25 Vo- 56 VID2 0 26 Vo+ 57 VID4 0 0 1 0 1 1.725 0 1 0 0 1.750 27 Vo- 58 VRM-pres 0 28 Vo+ 59 Vin- 0 0 0 1 1 1.775 Vin- 0 0 0 1 0 1.800 0 0 0 0 1 1.825 0 0 0 0 0 1.850 29 Vo- 60 30 Vo+ 61 Vin- 31 Vo- 62 Vin- Embedded Power for Business-Critical Continuity Rev.03.23.07 nxi110 4 of 4 Mechanical Notes All dimensions in INCHES (mm). Americas 3.800 (96.520) 3.600 (91.440) 0.425 (10.795) 0.563 (14.300) MAX 0.425 (10.795) 0.100 (2.540) TYP COMP CLEAR 0.54 (13.72) 2.300 (58.420) 1.075 (27.305) 2.615 (66.421) REF 1 62 KEEP OUT AREA 0.310 (7.874) 11 12 31 32 0.300 (7.620) 32-62 1-31 0.610 (15.494) 1.122 (28.499) REF 0.042 (1.067) KEY 0.093 (2.362) 3.000 (76.200) 0.307 (7.798) 3.186 (80.924) DIMENSIONS IN INCHES (MM) 5810 Van Allen Way Carlsbad, CA 92008 USA Telephone: +1 760 930 4600 Facsimile: +1 760 930 0698 Europe (UK) 0.425 (10.795) 6 No Contact 1 Waterfront Business Park Merry Hill, Dudley West Midlands, DY5 1LX United Kingdom Telephone: +44 (0) 1384 842 211 Facsimile: +44 (0) 1384 843 355 Asia (HK) 0.250 (6.350) MAX 0.063 (1.600) THK FR-4 DBL-SIDED CIRCUIT BOARD W/GOLD-PLATED (30u") CONNECTOR FINGERS 16th - 17th Floors, Lu Plaza 2 Wing Yip Street, Kwun Tong Kowloon, Hong Kong Telephone: +852 2176 3333 Facsimile: +852 2176 3888 For global contact, visit: Figure 1: Mechanical Drawing www.powerconversion.com technicalsupport@powerconversion.com While every precaution has been taken to ensure accuracy and completeness in this literature, Emerson Network Power assumes no responsibility, and disclaims all liability for damages resulting from use of this information or for any errors or omissions. TRP Emerson Network Power. The global leader in enabling business-critical continuity. AC Power Connectivity DC Power Embedded Power L O Inbound Power Integrated Cabinet Solutions Outside Plant Precision Cooling Figure 2: Thermal Reference Point (TRP) Monitor Tab Indicated Site Monitoring and Services EmersonNetworkPower. com Emerson Network Power and the Emerson Network Power logo are trademarks and service marks of Emerson Electric Co. (c)2007 Emerson Electric Co.