Power Entry Modules
with RFI Power Line Filter
for General or Medical Applications
UL Recognized
CSA Certified
VDE Approved
L Series
The L series power entry modules are compact units that
combine a multi-function power entry module and high
performance RFI filtering capabilities. They are available
with either a four-voltage selector or a DPST on/off switch.
Both variations can be specified with North American or
European fusing capabilities and are available in either
flange or snap-in mounting.
These filters are UL recognized, CSA certified, and VDE
approved. The L series modules offer a choice of filters
for general or medical applications.
EDL ModelsThe RFI filter is for general purpose
applications where line-to-line and line-to-ground noise
must be controlled. The filter is designed to meet the very
low leakage requirements of VDE portable equipment.
They are available in three current ratings.
EHL ModelsThis medical filter provides susceptibility
protection without the leakage current associated with line-
to-ground capacitors. Designed to allow equipment to
meet UL544 for patient care and nonpatient care
equipment, the EHL filter has a maximum leakage current
of 2 µA at 120 VAC 60 Hz. See Appendix C for more
information on medical applications and UL standards.
EDL1S/EHL1S
EDL4C/EHL4C
HL Models (with 4-voltage selection)
DL Models (with 4-voltage selection)
Resistor location for reference only.
NOTES: Note 1: Provision for dual European style fusing.
Note 2: On/Off switch present only with “S” suffix.
Electrical Schematics
DL Models (with switch)
HL Models (with switch)
To change selected voltage: disconnect the power cord;
open cover using a small blade screwdriver or similar tool;
insert the tool into the voltage selection slot and remove
wheel from unit; select desired voltage; replace wheel into
unit and close cover, making sure the selected voltage
appears in connector window.
Voltage Selection
Note 1
Note 2
Note 1
Note 1
Note 2
12
43
1
2
43
Note 1
www.cor.com - Libertyville, IL (847) 680-7400
L
100
Specifications – Filtered
Maximum leakage current, each line-to-ground:
@ 120 VAC 60 Hz: EDL Models 0.25 mA
EHL Models 2 µA
@ 250 VAC 50 Hz: EDL Models 0.50 mA
EHL Models 5 µA
Hipot rating (one minute):
line-to-ground EDL Models 1500 VAC
EHL Models 1500 VAC
line-to-line All Models 1450 VDC
Operating voltages:
1S_ & 1SC_ Models - Fixed 100, 120, 220, 240 VAC
4_ &4C_ Models – Selectable 100, 120, 220, 240 VAC
Operating frequency: 50/60 Hz
Rated voltage: 120/250 VAC
Switch: Rated for 10,000
(1S_ & 1SC_ models only) operations at full load
51 Amp inrush capability
Fuse (not included): Accepts one 1/4” x 1-1/4” fuse
or two 5 x 20mm fuses
Terminals: .110 (2.79) terminals except for switch.
Switch terminals .187 (4.8).
Minimum insertion loss in dB:
Line-to-ground in 50 ohm circuit
Current Frequency-MHz
Rating .05 .15 1 5 10 30
EDL Models
2A 6 14 24 40 45 50
4A 2 8 18 32 38 45
6A 1 6 17 31 37 45
EHL Models
6A 3 8 15 18 18 18
Line-to-line in 50 ohm circuit
Current Frequency-MHz
Rating .05 .15 1 3 5 10 30
EDL Models
2A 7 16 21 23 37 47 50
4A 6 15 18 23 26 45 47
6A 6 15 20 25 25 45 50
EHL Models
6A 4 14 20 28 32 38 42
Case Dimensions - Filtered
Metric shown in italics.
Part No. A B C D EF
+.008/-.00 +.008/-.00 ± .015
(max) (max) (max) +.203/-.00 +.203/-.00 ± .038
Flange 1.98 2.01 2.30 1.122 2.201 1.575
Filtered 50.3 51.1 58.4 28.50 55.91 40.00
Snap-in 1.28 2.01 2.30 1.122* 2.201
Filtered 32.5 51.1 58.4 28.50 55.91
For panel thickness of .031 - .079 (0.8 - 2.0). For panel thickness
of .083 - .114 (2.1 - 2.9) use 2.213 (56.21).
*For snap-in application, the D sides of the cutout must have a
.02 (.508) radius on the installation side.
Case Styles - Filtered
Flange Models
Snap-In Models
Recommended Panel Cutout
Note: Snap-in models allow front mounting only.
LSeries
Metric fuse models have additional jumper from filter to module
Libertyville, IL (847) 680-7400 - www.cor.com
Series
L
L
101
Specifications – Unfiltered
Rated current: 6 Amp @ 120 VAC
6 Amp @ 250 VAC
Operating voltages:
6EL1S & 6EL1SC
Models–Fixed 100, 120, 200, 240 VAC
6EL4 & 6EL4C
Models–Selectable 100, 120, 220, 240 VAC
Operating frequency: 50/60 Hz
Rated voltage: 120/250 VAC
Switch: Rated for 10,000
(6EL1S & 6EL1SC models only) operations at full load
51 Amp inrush capability
Fuse (not included): Accepts one 1/4” x 1-1/4” fuse
or two 5 x 20mm fuses
Terminals: .110 (2.79) terminals except for switch.
Switch terminals .187 (4.8).
Case Dimensions - Unfiltered
Metric shown in italics.
Part No. A B C D EF
+.008/-.00 +.008/-.00 ± .015
(max) (max) (max) +.203/-.00 +.203/-.00 ± .038
Flange 1.98 1.66 2.30 1.122 2.201 1.575
Unfiltered 50.3 42.2 58.4 28.50 55.91 40.00
Snap-in 1.28 1.66 2.30 1.122* 2.201
Unfiltered 32.5 42.2 58.4 28.50 55.91
For panel thickness of .031 - .079 (0.8 - 2.0). For panel thickness
of .083 - .114 (2.1 - 2.9) use 2.213 (56.21).
*For snap-in application, the D sides of the cutout must have a
.02 (.508) radius on the installation side.
Case Styles - Unfiltered
Flange Models
Snap-In Models
Available Part Numbers
Filtered Unfiltered
2EDL1S 6EDL1S 6EL1S
2EDL1SC 6EDL1SC 6EL1SC
2EDL1SM 6EDL1SM 6EL1SM
2EDL1SCM 6EDL1SCM 6EL1SCM
2EDL4 6EDL4 6EL4
2EDL4C 6EDL4C 6EL4C
2EDL4M 6EDL4M 6EL4M
2EDL4CM 6EDL4CM 6EL4CM
4EDL1S 6EHL1S
4EDL1SC 6EHL1SC
4EDL1SM 6EHL1SM
4EDL1SCM 6EHL1SCM
4EDL4 6EHL4
4EDL4C 6EHL4C
4EDL4M 6EHL4M
4EDL4CM 6EHL4CM
Recommended Panel Cutout
Note: Snap-in models allow front mounting only.
Ordering Information
Consult your local Corcom sales representative for pricing.