Series L Power Entry Modules with RFI Power Line Filter for General or Medical Applications UL Recognized CSA Certified VDE Approved L Series The L series power entry modules are compact units that combine a multi-function power entry module and high performance RFI filtering capabilities. They are available with either a four-voltage selector or a DPST on/off switch. Both variations can be specified with North American or European fusing capabilities and are available in either flange or snap-in mounting. EDL4C/EHL4C EDL1S/EHL1S Electrical Schematics DL Models (with switch) Note 1 2 4 These filters are UL recognized, CSA certified, and VDE approved. The L series modules offer a choice of filters for general or medical applications. EDL ModelsThe RFI filter is for general purpose applications where line-to-line and line-to-ground noise must be controlled. The filter is designed to meet the very low leakage requirements of VDE portable equipment. They are available in three current ratings. EHL ModelsThis medical filter provides susceptibility protection without the leakage current associated with lineto-ground capacitors. Designed to allow equipment to meet UL544 for patient care and nonpatient care equipment, the EHL filter has a maximum leakage current of 2 A at 120 VAC 60 Hz. See Appendix C for more information on medical applications and UL standards. 1 Note 2 3 DL Models (with 4-voltage selection) Note 1 HL Models (with switch) Note 1 Voltage Selection 2 1 Note 2 4 3 HL Models (with 4-voltage selection) L 99 To change selected voltage: disconnect the power cord; open cover using a small blade screwdriver or similar tool; insert the tool into the voltage selection slot and remove wheel from unit; select desired voltage; replace wheel into unit and close cover, making sure the selected voltage appears in connector window. Libertyville, IL (847) 680-7400 - www.cor.com Note 1 Resistor location for reference only. NOTES: Note 1: Provision for dual European style fusing. Note 2: On/Off switch present only with "S" suffix. L Series Specifications - Filtered Case Dimensions - Filtered Metric shown in italics. Maximum leakage current, each line-to-ground: @ 120 VAC 60 Hz: EDL Models EHL Models @ 250 VAC 50 Hz: EDL Models EHL Models Hipot rating (one minute): line-to-ground EDL Models EHL Models line-to-line All Models Operating voltages: 1S_ & 1SC_ Models - Fixed 4_ & 4C_ Models - Selectable 0.25 mA 2 A 0.50 mA 5 A 1500 VAC 1500 VAC 1450 VDC 100, 120, 220, 240 VAC 100, 120, 220, 240 VAC Operating frequency: 50/60 Hz Rated voltage: 120/250 VAC Switch: Rated for 10,000 operations at full load 51 Amp inrush capability (1S_ & 1SC_ models only) Fuse (not included): Terminals: Part No. Flange Filtered Snap-in Filtered * A B C (max) (max) (max) 1.98 50.3 1.28 32.5 2.01 51.1 2.01 51.1 2.30 58.4 2.30 58.4 D E +.008/-.00 +.008/-.00 +.203/-.00 +.203/-.00 1.122 28.50 1.122* 28.50 F .015 .038 2.201 1.575 55.91 40.00 2.201 55.91 For panel thickness of .031 - .079 (0.8 - 2.0). For panel thickness of .083 - .114 (2.1 - 2.9) use 2.213 (56.21). For snap-in application, the D sides of the cutout must have a .02 (.508) radius on the installation side. Case Styles - Filtered Flange Models Accepts one 1/4" x 1-1/4" fuse or two 5 x 20mm fuses .110 (2.79) terminals except for switch. Switch terminals .187 (4.8). Minimum insertion loss in dB: Line-to-ground in 50 ohm circuit Current Rating .05 EDL Models 2A 6 4A 2 6A 1 EHL Models 6A 3 .15 Frequency-MHz 1 5 10 30 14 8 6 24 18 17 40 32 31 45 38 37 50 45 45 8 15 18 18 18 Snap-In Models Line-to-line in 50 ohm circuit Current Rating .05 EDL Models 2A 7 4A 6 6A 6 EHL Models 6A 4 .15 Frequency-MHz 1 3 5 10 30 Metric fuse models have additional jumper from filter to module Note: Snap-in models allow front mounting only. 16 15 15 21 18 20 23 23 25 37 26 25 47 45 45 50 47 50 14 20 28 32 38 42 Recommended Panel Cutout L 100 www.cor.com - Libertyville, IL (847) 680-7400 Series L Specifications - Unfiltered Rated current: Recommended Panel Cutout 6 Amp @ 120 VAC 6 Amp @ 250 VAC Operating voltages: 6EL1S & 6EL1SC Models-Fixed 6EL4 & 6EL4C Models-Selectable 100, 120, 200, 240 VAC 100, 120, 220, 240 VAC Operating frequency: 50/60 Hz Rated voltage: 120/250 VAC Switch: Rated for 10,000 operations at full load 51 Amp inrush capability (6EL1S & 6EL1SC models only) Fuse (not included): Terminals: Ordering Information Consult your local Corcom sales representative for pricing. Accepts one 1/4" x 1-1/4" fuse or two 5 x 20mm fuses .110 (2.79) terminals except for switch. Switch terminals .187 (4.8). Case Dimensions - Unfiltered Metric shown in italics. Part No. Flange Unfiltered Snap-in Unfiltered * A B C (max) (max) (max) 1.98 50.3 1.28 32.5 1.66 42.2 1.66 42.2 2.30 58.4 2.30 58.4 D E +.008/-.00 +.008/-.00 +.203/-.00 +.203/-.00 1.122 28.50 1.122* 28.50 F .015 .038 2.201 1.575 55.91 40.00 2.201 55.91 For panel thickness of .031 - .079 (0.8 - 2.0). For panel thickness of .083 - .114 (2.1 - 2.9) use 2.213 (56.21). For snap-in application, the D sides of the cutout must have a .02 (.508) radius on the installation side. Case Styles - Unfiltered Flange Models Available Part Numbers Filtered 2EDL1S 2EDL1SC 2EDL1SM 2EDL1SCM 6EDL1S 6EDL1SC 6EDL1SM 6EDL1SCM Unfiltered 6EL1S 6EL1SC 6EL1SM 6EL1SCM 2EDL4 2EDL4C 2EDL4M 2EDL4CM 6EDL4 6EDL4C 6EDL4M 6EDL4CM 6EL4 6EL4C 6EL4M 6EL4CM 4EDL1S 4EDL1SC 4EDL1SM 4EDL1SCM 4EDL4 4EDL4C 4EDL4M 4EDL4CM 6EHL1S 6EHL1SC 6EHL1SM 6EHL1SCM 6EHL4 6EHL4C 6EHL4M 6EHL4CM Snap-In Models L 101 Note: Snap-in models allow front mounting only. Libertyville, IL (847) 680-7400 - www.cor.com