ENGINEERING DATA SHEET FLR300
TIME DELAY RELAY
2 PDT, 2 AMP
APPLICABLE SOCKETS:
S300
S302
Time delay relay (on operate, on release or repeat cycle timer)
Fixed or adjustable timing delay
Contact arrangement 2 PDT
Power supply Direct current
PRINCIPLE TECHNICAL CHARACTERISTICS
Contacts rated at 2 Amps / 28 Vdc
Weight < 40 grams
Dimensions of case 44mm x 28.6mm x 13.3mm max
Tin plated hermetically sealed metal can.
CONTACT ELECTRICAL CHARACTERISTICS
Minimum
operating cycles Contact rating per
pole and load type Load Current in Amps
@28VdC @115Vac/60-400Hz
100,000 cycles
100,000 cycles
500,000 cycles
resistive load
inductive load (L/R=5ms)
low level (30µA/30mV max)
2
0.75
-
0.3
-
-
100 cycles resistive overload 4 -
NUMBERING SYSTEM
FLR300 - B 4 A 0.1s A 1
Basic series designation___________________| | | | | | |
1-Mounting Styles (A,B,C,D,J)______________________| | | | | |
2-Terminal Types (1,2,4)_______________________________| | | | |
3-Types Of Operation (A,B,C)__ ____________________________| | | |
4-Time range (1,2,3,4) or fixed time in s _______________________| | |
5-Temperature Range (A,B) ____________________________________________| |
6-Accuracy (1,2,3) ________________________________________________________|
Featuring LEACH© power and control solutions
www.esterline.com
AMERICAS
6900 Orangethorpe Ave.
P.O. Box 5032
Buena Park, CA 90622
.
.
Tel: (01) 714-736-7599
Fax: (01) 714-670-1145
EUROPE
2 Rue Goethe
57430 Sarralbe
France
.
.
Tel: (33) 3 87 97 31 01
Fax: (33) 3 87 97 96 86
ASIA
Units 602-603 6/F Lakeside 1
No.8 Science Park West Avenue
Phase Two, Hong Kong Science Park
Pak Shek Kok, Tai Po, N.T.
Hong Kong
Tel: (852) 2 191 3830
Fax: (852) 2 389 5803
Data sheets are for initial product selection and comparison. Contact Esterline Power Systems prior to choosing a component.
Date of issue: 3/06 - 57 - Page 1 of 4
MOUNTING STYLES FLR300
Dimensions in mm
Tolerances unless otherwise specified ±0.25 mm
TERMINAL TYPES
Date of issue: 3/06 - 58 - Page 2 of 4
4
13.3
MAX
26 MAX ±0.15
35.7
44 MAX
CONTRASTING BEAD
±0.5
4
A
28.6
MAX B : ISO M3
C : UNC
M3
OR 4.40 UNC 2 B
12.3
MAX
35.5
36.7
44 MAX
D
±0.15
±0.15
4
3.8
12.7
1
3.8
1
35.5
36.7
44 MAX
12.3
MAX
J
1 2 4
±0.2
7.6 6.9
4Ø2 SILICON GASKET
SHORE A 15-30
±0.1
7.9 MAX
1.3
6.6-0.2
Ø0.76
±0.2
7.6 6.9
±0.03
Ø1.57
Ø2
1 2
±0.03
Ø1.57
SILICON GASKET
SHORE A 15-30
2.54
2.54
±0.03
Ø1.57
±0.04
7.9 MAX
5.08
5.08
Ø0.76±0.04
Ø1.57
±0.1
1.3
2.54
2.54
5.08
4
5.08
±0.03
TIN PLATED PINS SOLDER HOOKS GOLD PLATED PINS
FIXED
PERIOD
PERIOD
ADJUSTABLE
TYPES OF OPERATION FLR300
TIMING RANGE
ADJUSTABLE
Range 1: 0.1 to 2.5 seconds Rx = 356 * (T - to)
Range 2: 0.4 to 10 seconds Rx = 91.20 * (T - to)
Range 3: 3.2 to 80 seconds Rx = 11.38 * (T - to)
Range 4: 25 to 625 seconds Rx = 1.42 * (T - to)
where R x in kohms
T: desired time in seconds,
to: time measured with R x = 0.
E xample to determine R x value for a T time of 10 seconds: Choose range 3; measure time with R x = 0 (for example : to =
3.1 s); substract to from 10 seconds (10s - 3.1s = 6.9s); calculate R x = 11.38 kohms/s (range 3) x 6.9s T heoretical resistance:
R x = 78.5 kohms
GENERAL CHARACTERISTICS
Temperature range
- Code A -55° C to +125° C
- Code B -40° C to +85° C
Operating Voltage 18 to 32 Vdc (AIR norm 2021 E)
Recycle Time less than or equal to 50 ms
Dielectric strength between all pins connected together and can 750 V / 50 Hz
Insulation resistance at 100 Vdc (same condition as above) greater than or equal to 100 M
Sinusoidal vibration 20G / 10 to 2000 Hz
Shock 50G / 11 ms
Date of issue: 3/06 - 59 - Page 3 of 4
TIME
DE-ENERGIZED
TIME
OUTPUT
OUTPUT
0 V
OUTPUT
28 V
ENERGIZED
TIME
ENERGIZED DE-ENERGIZED
TIME
DE-ENERGIZED
ENERGIZED
DE-ENERGIZED
CODE C : REPEAT CYCLE TIMER
(CYCLIC RATIO = 1)
ON RELEASE
CODE B : TIME DELAY
ON OPERATE
CODE A : TIME DELAY
POWER SUPPLY
ACCURACY FLR300
fixed period adjustable period
Accuracy resistor Rx to choose
Code 3
Code 2
Code 1
±10%
±5%
±3%
±10%
±5%
±3%
5% 100 ppm /° C
2% 100 ppm /° C
1% 50 ppm /° C
SCHEMATIC DIAGRAM/TERMINAL LAYOUT
NOTES
1. Relays with B,C,D mounting and terminal 4 are compatible with socket families S300, SF300, S302, SF302...
2. Isolation spacer pads for PCB mounting available on request.
3. For other mounting styles or terminal types, please contact the factory.
Date of issue: 3/06 - 60 - Page 4 of 4
A
B
A
B
Y2
X1
32X21
A
B
A
X1
+ POWER SUPPLY
0V
B
32X21
2X21
A
B
X1
3
Y1X1Y2
Y1
2X21
X1Y2
3
+ POWER SUPPLY
0V
2X21
2X21
A
B
X1
RX
3
3
Y1
FIXED PERIOD ADJUSTABLE PERIOD
ENGINEERING DATA SHEET S300, S301, S302
RELAY SOCKET
10 AMP
BASIC SOCKET SERIES DESIGNATION FOR:
Series M300 (DC Coil), M301 (DC Coil),
M302 (DC Coil), FD300, FLS300, FLR300
GENERAL CHARACTERISTICS
Crimp tool contact #22 M 22520/2-01 with turret M 22520/2-14.
Insertion and extraction tool #22 M 81969/14-01.
Crimp tool contact #16 M 22520/1-01 with turret M 22520/1-02 or MS 3191-1.
Insertion and extraction tool #16 M 81969/14-03 .
Weight 35g max.
Temperature range 70° C to +125° C.
Featuring LEACH© power and control solutions
www.esterline.com
AMERICAS
6900 Orangethorpe Ave.
P.O. Box 5032
Buena Park, CA 90622
.
.
Tel: (01) 714-736-7599
Fax: (01) 714-670-1145
EUROPE
2 Rue Goethe
57430 Sarralbe
France
.
.
Tel: (33) 3 87 97 31 01
Fax: (33) 3 87 97 96 86
ASIA
Units 602-603 6/F Lakeside 1
No.8 Science Park West Avenue
Phase Two, Hong Kong Science Park
Pak Shek Kok, Tai Po, N.T.
Hong Kong
Tel: (852) 2 191 3830
Fax: (852) 2 389 5803
Data sheets are for initial product selection and comparison. Contact Esterline Power Systems prior to choosing a component.
Date of issue: 12/09 - 17 - Page 1 of 4
TERMINAL LAYOUT S300, S301, S302
MOUNTING HARDWARE
Date of issue: 12/09 - 18 - Page 2 of 4
28.2
35.7
DEPTH 9 MM
DETAIL
10.16
15.24
5.08
Ø 2
DEPTH 9 MM
5.08
X1
A
B
32X2 1
A
B
32X2 1
X1
0.9
3.2
2.0
14.1
DETAIL
± 0.3
A
B
32X2 1
X1
3.2
0.9
A
B
32X2 1
X1
Y2
Y1
Ø 2
± 0.3
± 0.1
12.68
CODE A S300 CODE D S302
MOUNTING HOLE LAYOUT
CODE B S301 CODE C S301
POSITION, TOLERANCE SEE CODE B POSITION, TOLERANCE SEE CODE B
FOR M300 RELAY FOR M302 RELAY
FOR M301 RELAY, FOR K COIL FOR M301 RELAY, FOR J COIL
FOR HOLE CLEARANCE,
SEE HARDWARE CODE
CODE 7 : 05-284-15
LOOSE METRIC HARDWARE
TOP MOUNT
MOUNTING TORQUE:0,45 ±0,1 Nm
FOR RELAYS WITH CODE B TERMINALS
1.2
MOUNTING HOLE:3,6 mm
CODE 6 : 05-284-13
LOOSE UNC HARDWARE
BOTTOM MOUNT TOP MOUNT
MOUNTING TORQUE:0,45 ±0,1 Nm
MOUNTING HOLE:3,6 mm MOUNTING HOLE:3,6 mm
1.2
1.2
CODE 8 : 05-284-20
FIXED UNC STUDS PER MIL-S-12883/41 - EDIT C
BOTTOM MOUNT TOP MOUNT
MOUNTING TORQUE: NUT 4/40:0,45 ±0,1 Nm - NUT 10-32: 1,2 MAX
MOUNTING HOLE: 5,3 mm MOUNTING HOLE: 3,6 mm
MAX
2.4
MAX
3.2
CODE 2 : 05-284-00
LOOSE METRIC HARDWARE
TOP MOUNT
MOUNTING TORQUE:0,45 ±0,1 Nm
:3,6 mm
4.0
CODE 1 : 05-284-12
LOOSE UNC HARDWARE
BOTTOM MOUNT
MOUNTING TORQUE
NUT 4/40:0,45 ±0,1 Nm
NUT 10-32:1,2 MAX
:3,6 mm
MAX
2.4
CODE 3 : 05-284-07
LOOSE METRIC HARDWARE
TOP MOUNT
MOUNTING TORQUE:0,45 ±0,1 Nm
:3,6 mm
MAX
4.0
CODE 8 : 05-284-20
LOOSE UNC STUDS MIL-S-12883/41 - EDIT C
BOTTOM MOUNT TOP MOUNT
MOUNTIONG TORQUE: NUT 4/40:0,45 ±0,1 Nm - NUT 10-32: 1,2 MAX
MOUNTING HOLE: 5,3 mm MOUNTING HOLE: 3,6 mm
2.4
3.2
WIRE INSULATION DIAMETER FOR SEAL TO GROMMET S300, S301, S302
Code A
Recommended for
contact code 2
contact code 8
Dia: 1.2 ......2.4mm
Code B
Recommended for
contact code 3
contact code 9
Dia: 0.8 ......1.6mm
CONTACT SIZE AND STYLE
Y1-Y2
05 912 00
31 036 00
Crimpend to accomodate AWG22
(for product code 2+3)
Contact mating end dia 0.8mm
(for contact code 8+9)
MIL-C-39029/92-531
Bin Code colour bands or
Bin Code numbering on crimpside
Contact mating end dia 0.8mm
Code 2
05 911 00 Crimpend to
accomodate
AWG16-18-20
Contact mating
end #16
Code 3
05 911 10 Crimpend to
accomodate
AWG20-22-24
Contact mating
end #16
Code 0 Without contacts
Code 8
30 315 00 Crimpend to
accomodate
AWG16-18-20
MIL-C-39029/92-
533
Bin Code colour
bands
or Bin Code
numbering
on crimpside
Contact mating
end #16
Code 9
30 315 10 Crimpend to
accomodate
AWG20-22-24
MIL-C-39029/92-
534
Bin Code colour
bands
or Bin Code
numbering
on crimpside
Contact mating
end #16
SOCKET NUMBERING SYSTEM
S300 A 1 A 2
1-Basic socket designation________________________| | | | |
2-Terminal Layout_____________________________________| | | |
3-Mounting Hardware_______________________________________| | |
4-Grommet to seal on wire insulation__________________________| |
5-Contact size and style___________________________________________|
Date of issue: 12/09 - 19 - Page 3 of 4
MS/LEACH CROSS PART NO. AND MATING RELAYS S300, S301, S302
MS - Number LEACH P/N Contacts to accomodate wire # Applicable for relays
MIL-S-12883/41
-01 S300-A6A2 16-18-20
Loose terminals
Above/below
panel mounting
M300-D4A
/-L/-N/-B/-C
-04 S300-A6B3 20-22-24
-02 S301-B6A2 16-18-20 M 301-D4F/-K
-03 S301-C6A2 16-18-20 M 301-D4E/-J
MS - Number LEACH P/N Contacts to accomodate wire # Applicable for relays
MIL-S-12883/41B
-11 S300-A1A2 16-18-20
Loose terminals
below
panel mounting
M300-D4A
/-L/-N/-B/-C
-14 S300-A1B3 20-22-24
-12 S301-B1A2 16-18-20 M 301-D4F/-K
-13 S301-C1A2 16-18-20 M 301-D4E/-J
MS - Number LEACH P/N Contacts to accomodate wire # Applicable for relays
MIL-S-12883/41C
-11S S300-A8A8 16-18-20
Loose terminals
Above/below
panel mounting
M300-D4A
/-L/-N/-B/-C
-14S S300-A8B9 20-22-24
-12S S301-B8A8 16-18-20 M301-D4F/-K
-13S S301-C8A8 16-18-20 M301-D4F/-J
-15S S302-D8A8 16-18-20 M302-D4A/
-L/-N/-B/-C
MIL-S-12883/41C
-16S S300-A9A8 16-18-20
Fixed terminals
Above/below
panel mounting
M300-D4A
/-L/-N/-B/-C
-19S S300-A9B9 20-22-24
-17S S301-B9A8 16-18-20 M 301-D4F/-K
-18S S301-C9A8 16-18-20 M 301-D4E/-J
-20S S302-D9A8 16-18-20 M 302-D4A/
-L/-N/-B/-C
Date of issue: 12/09 - 20 - Page 4 of 4