Specifications are subject to change without notice (27.02.00) 1
Plug Output Time range Supply:
24 to 230 VAC/DC
Circular SPDT 0.1 s - 10 m S 105 156 924
Circular DPDT 0.1 s - 10 m S 105 166 924
Timers
• Time ranges: 0.1 s to 10 m
• Easy-to-use (true) delay on release time function
• Easy time setting
• Knob-adjustable time setting
• Automatic start after drop-out of power supply
• Repeatability: ≤0.2%
• Output: 5 A SPDT or DPDT relay
• Plug-in module, S-housing
• LED-indication for power supply ON
• 24 to 230 VAC/DC power supply
• Cadminum-free contacts
• Timer in accordance with IEC 61812-1
Product Description
Mono-function, multi-voltage
(true) delay on release timer
with 4 selectable time ranges
from 0.1 s up to 10 m for
standard 11-pin circular sock-
ets. Often used in applica-
tions where a cooling fan has
to remain turned on for at cer-
tain period of time after a
motor has been turned off.
Ordering Key
Housing
Type/function
Output
Power supply
Type Selection
Time Specifications
Time ranges
Selectable by DIP-switch 0.1 - 1 s
1 - 10 s
0.1 - 1 m
1 - 10 m
Setting accuracy < ±10%
Repeatability ≤0.2%
Time variation
Within rated power supply ≤0.05%/V
and ambient temperature ≤0.2%/°C
Minimum control pulse Power supply applied for
min. 200 ms
Output Specifications
Output S 105 156 924 SPDT relay
S 105 166 924 DPDT relay
Rated insulation voltage
250 VAC (rms) (cont./elect.)
Contact ratings (AgNi) µ (micro gap)
(IEC 60947-5-1/IEC 60337)
Resistive loads
AC 1
5 A/250 VAC
DC 1
5 A/24 VDC
Small inductive loads
AC 15
2 A/250 VAC
DC 13
3 A/24 VDC
Mechanical life ≥2 x 106operations
Electrical life AC 1 ≥105operations
(at max. load)
Operating frequency ≤3600 operations/h
Insulation voltage
Rated insulation voltage ≥2.0 kVAC (rms) (cont./elect.)
Rated impulse withstand volt. 4 kV (1.2/50 µs) (cont./elect.)
(IEC 60664)
Delay on Release
Type S 105
S 105 166 924
Supply Specifications
Power supply
Overvoltage cat. III (IEC 60664)
Rated operational voltage
through pins 2 & 10 24 to 230 VAC/DC ±15%
45 to 65 Hz
(pin 2 positive)
Voltage interruption ≤40 ms
Rated insulation voltage None
Rated impulse withstand volt. 4 kV (1.2/50 µs)
Rated operational current
AC supply 9 mA @ 230 VAC
5 mA @ 115 VAC
3 mA @ 24 VAC
DC supply 1.5 mA @ 24 VDC
Inrush current 0.5 AAC for < 100 ms