Grayhill, Inc. • 561 Hillgrove Avenue • LaGrange, Illinois 60525-5997 • USA • Phone: 708-354-1040 • Fax: 708-354-2820 • www.grayhill.com
System 50
System 50
32 31 30 29 28 27 26 25 24 23 22 21 20 19 18 17 16 15 14 13 12 11 10 9 8 7 6 5 4 3 2 1
0 1 2 3 4 5 6 7 8 9 10 11 12 13 14 15
Y
B
W
R
AC INPUT
AC OUTPUT
DC INPUT
DC OUTPUT
+–
14.05 (356,9)
13.55 (344,2)
0.40
(10,2)
50 PIN EDGE CARD OR HEADER
CONNECTOR FOR LOGIC SIGNALS
(SEE NOTES)
LOGIC SUPPLY
TERMINAL STRIP
FIELD WIRING
TERMINAL STRIP
5 A
FUSE
0.45 (11,4)
2.60 (66,0)
KEY
SLOT
PINS
11/13
PIN 1
USER INSTALLABLE
JUMPER FOR +VCC (2 PLACES) STATUS LED
STANDOFF I.D. 0.15 (3,8) DIA.
(4 PLACES) CLEARANCE
FOR #6 SCREWS
2.20
(55,9)
MAX.
3.00
(76,2)
3.50
(88,9)
0.25 (6,4)
0.25
(6,4)
0.75 (19,1)
NOTE: MAXIMUM
TERMINAL SCREW
TORQUE NOT TO
EXCEED 5 IN-LBS.
16 CHANNEL RACK: Standard
Part No. 70RCK16
Dimensions are shown in inches
(and millimeters).
All tolerances are ± 0.010 (0,25)
unless otherwise specified.
RACKS
16 Channel
FEATURES
For use with System 50 Style Controllers
Available for Standard, Miniature, G5 and
OpenLine® Modules
Panel and DIN Rail Mount Versions
UL, CSA Certified
System 50
11
Grayhill, Inc. • 561 Hillgrove Avenue • LaGrange, Illinois 60525-5997 • USA • Phone: 708-354-1040 • Fax: 708-354-2820 • www.grayhill.com
System 50
System 50
16 CHANNEL RACK: Miniature
16 CHANNEL RACK: G5
System 50
12
0 1 2 3 4 5 6 7 8 9 101112131415
Y
B
W
R
AC INPUT
AC OUTPUT
DC INPUT
DC OUTPUT
+–
16
15
14
13
12
11
10
9
8
7
6
5
4
3
2
1
32
31
30
29
28
27
26
25
24
23
22
21
20
19
18
17
10.00 (254,0)
9.35 (237,5)
LOGIC SUPPLY
TERMINAL STRIP
FIELD WIRING
TERMINAL STRIP
STANDOFF I.
D
0.15 (3,8) DIA.
(4 PLACES)
CLEARANCE
FOR #6 SCR
E
STATUS LED
0.40
(10,2)
.45
1,4)
0.25 (6,4)
.
60
6
,0)
3.50
(88,9)
3.00
(76,2)
2.20 (55,9)
MAX.
0.75
(19,1)
5A FUSE
MODULE HOLD DOWN
STRIP WITH THUMB SCREWS
CARD EDGE OR HEADER CONNECTOR
FOR LOGIC SIGNALS (SEE NOTES)
USER INSTALLABLE JUMPER
FOR +VCC (2 PLACES)
PIN 1
KEY
SLOT
PINS 11/13
0.2 (5,1)
NOTE
:
MAXIMUM
TERMINAL SCREW
TORQUE NOT TO
EXCEED 5 IN-LBS.
Part No. 70MRCK16
Dimensions are shown in inches
(and millimeters).
All tolerances are ± 0.010 (0,25)
unless otherwise specified.
Part No. 70GRCK16
Dimensions are shown in inches
(and millimeters).
All tolerances are ± 0.010 (0,25)
unless otherwise specified.
0 1 2 3 4 5 6 7 8 9 101112131415
+–
10.00 (254,0)
9.125 (231,8)
LOGIC SUPPLY
TERMINAL STRIP
FIELD WIRING
TERMINAL STRIP
STANDOFF I.D. 0.15 (3,8) DIA.
(4 PLACES) CLEARANCE
FOR #6 SCREW
STATUS LED
ON THE MODULE
0.25 (6,4)
3.25
(82,6)
2.75
(69,9)
3.39
(86,1)
MAX.
0.75
(19,1)
PIN 1
0.2 (5,1)
1 3 5 7 9 11 13 15 17 19 21 23 25 27 29 312 4 6 8 101214161820222426283032
.093 (2,36) REF.
NOTE: MAXIMUM
TERMINAL SCREW
TORQUE NOT TO
EXCEED 5 IN-LBS.
Grayhill, Inc. • 561 Hillgrove Avenue • LaGrange, Illinois 60525-5997 • USA • Phone: 708-354-1040 • Fax: 708-354-2820 • www.grayhill.com
System 50
System 50
16 CHANNEL RACK: G5 Control and Field Connection Terminal Blocks
Part No. 70GRCK16T
Dimensions are shown in inches
(and millimeters).
All tolerances are ± 0.010 (0,25)
unless otherwise specified.
16 CHANNEL RACK: G5 Channel-to-Channel Isolation
Part No. 70GRCK16I and 70GRCK16I-DIN
Dimensions are shown in inches
(and millimeters).
All tolerances are ± 0.010 (0,25)
unless otherwise specified.
System 50
13
1.687
(42,85)
3.392
(86,16)
REF.
.750
(19,05)
REF.
2 POSITION
TERMINAL STRIP
FOR CONTROL
LOGIC
SPARE FUSE
SWAGED STANDOFF THRU
HOLE .15 (3,81) DIA. (4 PLACES)
(CLEARANCE FOR #6 SCREW)
RES. 3.3 K/.25W
(2 PLACES)
KNURL
FASTENER
(16 PLACES)
32 POS. TERMINAL
STRIP FOR CONTROL
LOGIC STRIP
9.500 (241,3)
9.000 (228,6)
32 POSITION TERMINAL STRIP
FOR FIELD WIRING
2.750
(69,85)
3.250
(82,55)
.250 (6,35)
.250 (6,35)
1 2 3 4 5 6 7 8 9 10 11 12 13 14 15 16 17 18 19 20 21 22 23 24 25 26 27 28 29 30 31 32
+VCC –
CONTROL
FIELD
32 31 30 29 28 27 26 25 24 23 22 21 20 19 18 17 16 15 14 13 12 11 10 9 8 7 6 5 4 3 2 1
NOTE: MAXIMUM
TERMINAL SCREW
TORQUE NOT TO
EXCEED 5 IN-LBS.
1 2 3 4 5 6 7 8 9 10 11 12 13 14 15 16 17 18 19 20 21 22 23 24 25 26 27 28 29 3031 32
GND
2.125
(53,98)
4.00
(101,6)
REF.
DIN CARRIER
9.160 ± .020 (232,66 ± 0,51)
PANEL MOUNT
9.000 ± .010 (228,6 ± 0,25)
32 POSITION TERMINAL STRIP
FOR FIELD WIRING
PANEL
MOUNT
4.270
± .010
(108,46
± 0,25)
DIN
CARRIER
4.800
± .020
(121,92
± 0,51)
RES. 3.3 K/.25W
(16 PLACES)
KNURL
FASTENER
(16 PLACES)
32 POS. TERMINAL
STRIP FOR CONTROL
LOGIC STRIP
CONTROL FIELD
32 31 30 29 28 27 26 25 24 23 22 21 20 19 18 17 16 15 14 13 12 11 10 9 8 7 6 5 4 3 2 1
3.500 ± .010
(88,9 ± 0,25)
8.500 ± .010 (215,9 ± 0,25)
NOTE: MAXIMUM
TERMINAL SCREW
TORQUE NOT TO
EXCEED 5 IN-LBS.
Grayhill, Inc. • 561 Hillgrove Avenue • LaGrange, Illinois 60525-5997 • USA • Phone: 708-354-1040 • Fax: 708-354-2820 • www.grayhill.com
System 50
System 50
16 CHANNEL RACK: OpenLine® for System 50
Part No. 70LRCK16-HL
Dimensions are shown in inches
(and millimeters).
All tolerances are ± 0.010 (0,25)
unless otherwise specified.
16 CHANNEL RACK: OpenLine®w/ DIN Rail Mount for System 50
Part No. 70LRCK16-DIN
Dimensions are shown in inches
(and millimeters).
All tolerances are ± 0.010 (0,25)
unless otherwise specified.
System 50
14
3.4
(85.93)
MAX
.75
(19.05)
REF
.24
(6.05)
4.3
(108.46)
3.8
(96.52)
.25
(6.35) 5.0 (127.00)
5.5 (139.70)
REMOVABLE JUMPER
CONNNECTS GND
TO PLATED HOLE
FOR GROUNDING
FIELD WIRING
TERMINAL STRIP
STANDOFF I.D. 0.15
(3.81) DIA. (4 PLACES)
CLEARANCE FOR #6 SCREW
PIN 1
5A FUSE
50-PIN
STRAIGHT
HEADER
CONNECTOR
LOGIC SUPPLY TERMINAL STRIP
TOP ROW: + LOGIC SUPPLY
BOTTOM ROW: GND
M7M6M5M4
BA
M3M2M1M0
50
2
149
31
32
29
30
27
28
25
26
23
24
21
22
19
20
17
1816
15
14
13
12
11
10
9
8
7
6
5
24
31+5 +5
NOTE: MAXIMUM
TERMINAL SCREW
TORQUE NOT TO
EXCEED 5 IN-LBS.
3.8
(95.81)
REF
2.2
(56.49)
DIN CARRIER
4.7 (119.13)
PCB
4.3 (108.46)
PCB
5.5 (139.70)
DIN CARRIER
5.7 (143.76)
REMOVABLE JUMPER
CONNNECTS GND
TO PLATED HOLE
FOR GROUNDING
LOGIC SUPPLY
TERMINAL STRIP
TOP ROW: + LOGIC SUPPLY
BOTTOM ROW: GND
FIELD WIRING
TERMINAL STRIP
PIN 1
5A FUSE
50-PIN
STRAIGHT
HEADER
CONNECTOR
+5 +5
M7M6M5M4
BA
M3M2M1M0
50
2
149
31
32
29
30
27
28
25
26
23
24
21
22
19
20
17
1816
15
14
13
12
11
10
9
8
7
6
5
24
31
NOTE: MAXIMUM
TERMINAL SCREW
TORQUE NOT TO
EXCEED 5 IN-LBS.
Grayhill, Inc. • 561 Hillgrove Avenue • LaGrange, Illinois 60525-5997 • USA • Phone: 708-354-1040 • Fax: 708-354-2820 • www.grayhill.com
System 50
System 50
SCHEMATIC: Part No. 70GRCK16
SCHEMATIC: Part No. 70GRCK16T
SCHEMATIC: Part Nos. 70GRCK16I AND 70GRCK16I-DIN
System 50
15
1234567891011121314151617181920212223242526272829303132
+
49
47
45
43
41
39
37
35
33
31
29
27
25
23
21
19
17
15
13
11
9
7
5
3
1
50
48
46
44
42
40
38
36
34
32
30
28
26
24
22
20
18
16
14
12
10
8
6
4
2
0 1 2 3 4 5 6 7 8 9 10 11 12 13 14 15
1
2
3
4
5
N/C
N/C
N/C
N/C
N/C
N/C
N/C
3.3K
50 PIN HEADER
CONNECTOR FOR
LOGIC SIGNALS
LOGIC SUPPLY
TERMINAL STRIP
U
SER INSTALLABLE
J
UMPER FOR +VCC
1 A FUSE FIELD
WIRING
TERMINAL
STRIP
MODULE
POSITION
1
2
3
4
5
BARRIER STRIP
FOR FIELD WIRING
OF MODULE
MODULE
LOCATION
CONTROL
BARRIER
STRIP
PULL-UP
RESISTOR
3.3 K:
+VCC
LOGIC
+VCC
LOGIC
+VCC
LOGIC
+VCC
LOGIC
+VCC
LOGIC
+VCC
LOGIC
+VCC
LOGIC
+VCC
LOGIC
+VCC
LOGIC
+VCC
LOGIC
+VCC
LOGIC
+VCC
LOGIC
+VCC
LOGIC
+VCC
LOGIC
+VCC
LOGIC
+VCC
LOGIC
GND
1 2 3 4 5 6 7 8 9 10 11 12 13 14 15 16 17 18 19 20 21 22 23 24 25 26 27 28 29 30 31 32
0 1 2 3 4 5 6 7 8 9 10 11 12 13 14 15
1 2 3 4 5 6 7 8 9 10 11 12 13 14 15 16 17 18 19 20 21 22 23 24 25 26 27 28 29 30 31 32 33
Grayhill, Inc. • 561 Hillgrove Avenue • LaGrange, Illinois 60525-5997 • USA • Phone: 708-354-1040 • Fax: 708-354-2820 • www.grayhill.com
System 50
System 50
SCHEMATIC: Part Nos. 70RCK16 and 70MRCK16
SCHEMATIC: Part No. 70LRCK16-HL, -DIN
System 50
16
N/C
N/C
N/C
N/C
N/C
N/C
N/C
N/C12
34
56
78
910
1112
13
15
17
14
16
18
19
21
23
25
27
29
31
33
20
22
24
26
28
30
32
34
5
6
7
8
9
4
3
2
1
44
46
48
50
36
38
40
42
43
45
47
49
35
37
39
41
31
3230
2927
2826
2523
2422
2119
2018
1715
1614
1311
1210
97
86
53
42
1
FIELD
WIRING
TERMINAL
STRIP
MODULE
LOCATION
M0 M1 M2 M3 M4 M5 M6 M7
LOGIC
SUPPLY
TERMINAL
STRIP
+
+
1234567891011121314151617181920212223242526272829303132
+
49
47
45
43
41
39
37
35
33
31
29
27
25
23
21
19
17
15
13
11
9
7
5
3
1
50
48
46
44
42
40
38
36
34
32
30
28
26
24
22
20
18
16
14
12
10
8
6
4
2
0 1 2 3 4 5 6 7 8 9 10 11 12 13 14 15
1
2
3
4
5
N/C
N/C
N/C
N/C
N/C
N/C
N/C
3.3K
50 PIN EDGE
OR HEADER
CONNECTOR FOR
LOGIC SIGNALS
LOGIC SUPPLY
TERMINAL STRIP
USER INSTALLABLE
JUMPER FOR +VCC
(2 PLACES)
FIELD
WIRING
TERMINAL
STRIP
5A FUSE
MODULE
POSITION
Grayhill, Inc. • 561 Hillgrove Avenue • LaGrange, Illinois 60525-5997 • USA • Phone: 708-354-1040 • Fax: 708-354-2820 • www.grayhill.com
System 50
System 50
Part Number I/O Description UL CSA Style
70RCK16 16 Card edge X X Standard
70RCK16-HL 16 50-pin header with ejector levers X X Standard
70MRCK16-EC 16 Card edge X X Mini
70MRCK16-HL 16 50-pin header with ejector levers X X Mini
70GRCK16-HL 16 50-pin header with ejector levers X X G5
70LRCK16-HL 16 50-pin header with ejector levers X X OpenLine®
70LRCK16-DIN 16 50-pin header with DIN rail mnt. X X OpenLine®
70GRCK16I 16 Positive or negative true logic*
Panel Mount
X XG5
70GRCK16I-DIN 16 Positive or negative true logic*
DIN rail mount
X XG5
70GRCK16T 16 Negative true logic*–
Panel Mount
X XG5
* Positive true logic applies to output modules only.
ORDERING INFORMATION (modules ordered separately)
Available from your local Grayhill
Distributor. For prices and discounts, contact
a local Sales Office, an authorized local
Distributor, or Grayhill.
System 50
17