Ultrasonic sensor UB800-18GM40-E5-V1 Technical data General specifications Sensing range Adjustment range Unusable area Standard target plate Transducer frequency Response delay Indicators/operating means LED green LED yellow LED red Electrical specifications Operating voltage UB No-load supply current I0 Input Input type Model Number UB800-18GM40-E5-V1 Single head system Features * Short design, 40 mm * Function indicators visible from all directions * Switch output * 5 output modes * Program input * Temperature compensation Curves Characteristic response curve Distance Y [mm] 200 Output Output type Rated operational current Ie Default setting Voltage drop Ud Repeat accuracy Switching frequency f Range hysteresis H Temperature influence Ambient conditions Ambient temperature Storage temperature Mechanical specifications Protection degree Connection Material Housing Transducer Mass Compliance with standards and directives Standard conformity Standards 50 ... 800 mm 70 ... 800 mm 0 ... 50 mm 100 mm x 100 mm approx. 255 kHz approx. 100 ms Power on indication of the switching state flashing: program function object detected permanently red: Error red, flashing: program function, object not detected 10 ... 30 V DC , ripple 10 %SS 20 mA 1 program input operating distance 1: -UB ... +1 V, operating distance 2: +6 V ... +UB input impedance: > 4,7 k program pulse: 1 s 1 switch output E5, pnp NO/NC, programmable 200 mA , short-circuit/overload protected Switch point A1: 70 mm Switch point A2: 800 mm 3V 1 % 4 Hz 1 % of the set operating distance 1.5 % of full-scale value -25 ... 70 C (248 ... 343 K) -40 ... 85 C (233 ... 358 K) IP67 V1 connector (M12 x 1), 4-pin brass, nickel-plated epoxy resin/hollow glass sphere mixture; foam polyurethane, cover PBT 25 g EN 60947-5-2:2007 IEC 60947-5-2:2007 150 100 50 2 1 0 -50 -100 -150 Release date: 2009-11-26 15:57 Date of issue: 2009-11-26 205343_ENG.xml -200 0 200 400 600 800 1000 Y 1200 1400 Distance X [mm] X Curve 1: flat surface 100 mm x 100 mm Curve 2: round bar, O 25 mm Subject to reasonable modifications due to technical advances. Copyright Pepperl+Fuchs, Printed in Germany Pepperl+Fuchs Group * Tel.: Germany +49 621 776-0 * USA +1 330 4253555 * Singapore +65 67799091 * Internet http://www.pepperl-fuchs.com 1 Ultrasonic sensor UB800-18GM40-E5-V1 Additional Information Dimensions Programmable output modes 1. Window mode, normally open mode A1 < A2: M18 x 1 M12 x 1 A1 object distance A2 2. Window mode, normally closed mode A2 < A1: A2 A1 3. One switch point, normally open mode A1 -> A2 24 4 4. One switch point, normally closed mode A2 -> : LED 24.5 39.2 10 50.2 A1 5. A1 -> , A2 -> : Object presence detection mode Object detected: Switch output closed No object detected: Switch output open Accessories UB-PROG2 Programming unit OMH-04 Mounting aid BF 18 Mounting flange Electrical Connection BF 18-F Mounting flange Standard symbol/Connections: (version E5, pnp) U 1 (BN) + UB 2 (WH) Teach input 4 (BK) Switch output 3 (BU) - UB Core colours in accordance with EN 60947-5-2. BF 5-30 Mounting flange V1-G-2M-PVC Cable connector V1-W-2M-PUR Cable connector Pinout Connector V1 2 1 3 4 Release date: 2009-11-26 15:57 Date of issue: 2009-11-26 205343_ENG.xml Adjusting the switching points The ultrasonic sensor features a switch output with two teachable switching points. These are set by applying the supply voltage -UB or +UB to the TEACH-IN input. The supply voltage must be applied to the TEACH-IN input for at least 1 s. LEDs indicate whether the sensor has recognised the target during the TEACH-IN procedure. Switching point A1 is taught with -UB, A2 with +UB. Five different output functions can be set 1. Window mode, normally-open function 2. Window mode, normally-closed function 3. one switching point, normally-open function 4. one switching point, normally-closed function 5. Detection of object presence TEACH-IN window mode, normally-open function * Set target to near switching point * TEACH-IN switching point A1 with -UB * Set target to far switching point * TEACH-IN switching point A2 with +UB TEACH-IN window mode, normally-closed function * Set target to near switching point * TEACH-IN switching point A2 with +UB 2 Subject to reasonable modifications due to technical advances. Copyright Pepperl+Fuchs, Printed in Germany Pepperl+Fuchs Group * Tel.: Germany +49 621 776-0 * USA +1 330 4253555 * Singapore +65 67799091 * Internet http://www.pepperl-fuchs.com Ultrasonic sensor UB800-18GM40-E5-V1 * Set target to far switching point * TEACH-IN switching point A1 with -UB TEACH-IN switching point, normally-open function * Set target to near switching point * TEACH-IN switching point A2 with +UB * Cover sensor with hand or remove all objects from sensing range * TEACH-IN switching point A1 with -UB TEACH-IN switching point, normally-closed function * Set target to near switching point * TEACH-IN switching point A1 with -UB * Cover sensor with hand or remove all objects from sensing range * TEACH-IN switching point A2 with +UB TEACH-IN detection of objects presence * Cover sensor with hand or remove all objects from sensing range * TEACH-IN switching point A1 with -UB * TEACH-IN switching point A2 with +UB Default setting of switching points A1 = blind range, A2 = nominal distance LED Displays Displays in dependence on operating mode TEACH-IN switching point: Object detected No object detected Object uncertain (TEACH-IN invalid) Normal operation Fault Red LED Yellow LED off flashes On off on flashes off off Switching state Previous state Installation conditions If the sensor is installed at places, where the environment temperature can fall below 0 C, for the sensors fixation, one of the mounting flanges BF18, BF18-F or BF 5-30 must be used. Release date: 2009-11-26 15:57 Date of issue: 2009-11-26 205343_ENG.xml In case of direct mounting of the sensor in a through hole using the steel nuts, it has to be fixed at the middle of the housing thread. If a fixation at the front end of the threaded housing is required, plastic nuts with centering ring (accessories) must be used. Subject to reasonable modifications due to technical advances. Copyright Pepperl+Fuchs, Printed in Germany Pepperl+Fuchs Group * Tel.: Germany +49 621 776-0 * USA +1 330 4253555 * Singapore +65 67799091 * Internet http://www.pepperl-fuchs.com 3