SPECIFICATION
MODEL
DC VOLTAGE
RATED CURRENT
RATED POWER
OUTPUT
VOLTAGE ADJ. RANGE Note.6
CURRENT ADJ. RANGE
LINE REGULATION
LOAD REGULATION
SETUP, RISE TIME Note.8
HOLD UP TIME (Typ.)
VOLTAGE RANGE Note.5
FREQUENCY RANGE
POWER FACTOR (Typ.)
EFFICIENCY (Typ.)
AC CURRENT
(Typ.)
INPUT
INRUSH CURRENT (Typ.)
LEAKAGE CURRENT
SAFETY STANDARDS Note.7
WORKING TEMP.
WORKING HUMIDITY
STORAGE TEMP., HUMIDITY
TEMP. COEFFICIENT
VIBRATION
MTBF
DIMENSIONOTHERS
NOTE
PACKING
OVER CURRENT
SHORT CIRCUIT
OVER VOLTAGE
OVER TEMPERATURE
Can be adjusted by internal potentiometer A type only
16ms at full load 230VAC / 115VAC
90 ~ 264VAC 127 ~ 370VDC
47 ~ 63Hz
PF>0.98/115VAC, PF>0.95/230VAC (Please refer to "Power Factor Characteristic" curve)
1.8A / 115VAC 0.8A / 230VAC
2.1A / 115VAC 0.9A / 230VAC
<0.75mA / 240VAC
95 ~ 108%
Protection type : Constant current limiting, recovers automatically after fault condition is removed
Constant current limiting, recovers automatically after fault condition is removed
Compliance to EN55015, EN55022 (CISPR22) Class B, EN61000-3-2 Class C ( 50% load) ; EN61000-3-3≧
Compliance to EN61000-4-2,3,4,5,6,8,11, EN61547, EN55024, light industry level (surge 4KV), criteria A
-40 ~ +70 (Refer to "Derating Curve")℃
20 ~ 95% RH non-condensing
-40 ~ +80 , 10 ~ 95% RH℃
±0.03%/ (0 ~ 50 )℃℃
10 ~ 500Hz, 5G 12min./1cycle, period for 72min. each along X, Y, Z axes
192.2K hrs min. MIL-HDBK-217F (25 )℃
228*68*38.8mm (L*W*H)
1. All parameters NOT specially mentioned are measured at 230VAC input, rated load and 25 of ambient temperature.℃
2. Ripple & noise are measured at 20MHz of bandwidth by using a 12" twisted pair-wire terminated with a 0.1uf & 47uf parallel capacitor.
3. Tolerance : includes set up tolerance, line regulation and load regulation.
4. Please refer to "DRIVING METHODS OF LED MODULE".
5. Derating may be needed under low input voltages. Please check the static characteristics for more details.
6. A type only.
7. Safety and EMC design refer to EN60598-1, CNS15233, GB7000.1, FCC part18.
8. Length of set up time is measured at cold first start. Turning ON/OFF the power supply may lead to increase of the set up time.
9. The power supply is considered as a component that will be operated in combination with final equipment. Since EMC performance will be affected by the
complete installation, the final equipment manufacturers must re-qualify EMC Directive on the complete installation again.
10. Refer to warranty statement.
11. To fulfill requirements of the latest ErP regulation for lighting fixtures, this LED power supply can only be used behind a switch without permanently
connected to the mains.
1.15Kg; 12pcs/14.8Kg/0.8CUFT
Protection type : Shut down o/p voltage with auto-recovery or re-power on to recovery
185W Single Output Switching Power Supply
Universal AC input / Full range
Built-in active PFC function
High efficiency up to 94%
Protections: Short circuit / Over current / Over voltage / Over temperature
Cooling by free air convection
OCP point adjustable through output cable or internal potentiometer
IP67 / IP65 design for indoor or outdoor installations
Three in one dimming function (1~10Vdc or PWM signal or resistance)
Suitable for LED lighting and street lighting applications
Compliance to worldwide safety regulations for lighting
Suitable for dry / damp / wet locations
Type HL for use in class , Division 2 hazardous(Classified) location luminairesⅠ
7 years warranty (Note.10)
■Features :
HLG-185 series
RIPPLE & NOISE (max.)
Note.2
VOLTAGE TOLERANCE
Note.3
ENVIRONMENT
SAFETY &
EMC
PROTECTION
Shut down o/p voltage, recovers automatically after temperature goes down
Blank : IP67 rated. Cable for I/O connection.
14 ~ 17V 18 ~ 21V 23 ~ 27V 28 ~ 34V 34 ~ 38V 41 ~ 46V 54 ~ 63V
47 ~ 53V 59 ~ 65V
92% 93% 93.5% 94% 94% 94% 94%94% 94%
±2.5%
6.5 ~ 13A
±2.0%
5.75 ~ 11.5A
±1.0%
4.65 ~ 9.3A
±1.0%
3.9 ~ 7.8A
±1.0%
3.1 ~ 6.2A
±1.0%
2.6 ~ 5.2A
±1.0%
1.95 ~ 3.9A
±0.5% ±0.5% ±0.5% ±0.5% ±0.5% ±0.5% ±0.5%
±2.0% ±1.5% ±1.0% ±0.5% ±0.5% ±0.5% ±0.5%
±1.0%
1.72 ~ 3.45A
±0.5%
±0.5%
±1.0%
2.2 ~ 4.4A
±0.5%
±0.5%
12V 15V 20V 24V 30V 36V 48V
13A 11.5A 9.3A 7.8A 6.2A 5.2A 3.9A
156W 172.5W 186W 187.2W 186W 187.2W 187.2W
150mVp-p 150mVp-p
13.5 ~ 17V
150mVp-p
17 ~ 22V
150mVp-p
22 ~ 27V
200mVp-p
27 ~ 33V
200mVp-p
33 ~ 40V
200mVp-p
43 ~ 53V10.8 ~ 13.5V
54V
3.45A
186.3W
200mVp-p
49 ~ 58V
42V
4.4A
184.8W
200mVp-p
38 ~ 46V
HLG-185-12
HLG-185-15
HLG-185-20
HLG-185-24
HLG-185-30
HLG-185-36
HLG-185-48 HLG-185-54
HLG-185-42
12V
15V ~ 54V
D (option, safety pending) : IP67 rated. Timer dimming function, contact MEAN WELL for details.
EMC IMMUNITY
EMC EMISSION
UL8750, CSA C22.2 No. 250.0-08, EN61347-1, EN61347-2-13 independent IP65 or IP67, J61347-1, J61347-2-13 approved ;
design refer to UL60950-1, TUV EN60950-1
COLD START 65A(t =445 s measured at 50% I ) at 230VAC
width peak
WITHSTAND VOLTAGE
ISOLATION RESISTANCE
I/P-O/P:3.75KVAC I/P-FG:2KVAC O/P-FG:1.5KVAC
I/P-O/P, I/P-FG, O/P-FG:100M Ohms / 500VDC / 25 / 70% RH℃
HLG-185-12 A
A : IP65 rated. Output voltage and constant current level can be adjusted through internal potentiometer.
B : IP67 rated. Constant current level adjustable through output cable with 1~10Vdc or 10V PWM signal or resistance.
CONSTANT CURRENT REGION Note.4
6 ~12V 7.5 ~ 15V 10 ~ 20V 12 ~ 24V 15 ~ 30V 18 ~ 36V 24 ~ 48V 27 ~ 54V
21 ~ 42V
1000ms,50ms/115VAC 500ms,50ms/230VAC at full load ; B type 1000ms,200ms/115VAC 500ms,200ms/230VAC at 95% load
FMM
110
SELV
IP65 IP67
Type HL
Bauar
Sicherheit
egel gema
t gepruft
od
be
www.
ID 2000000000
tuv.com
wac g
os
μ
File Name:HLG-185-SPEC 2015-07-22