Document Number: 94395 For technical questions, contact: ind-modules@vishay.com www.vishay.com
Revision: 11-Aug-08 3
ST1230C..KP Series
Phase Control Thyristors
(Hockey PUK Version), 1745 A Vishay High Power Products
Note
• The table above shows the increment of thermal resistance RthJC when devices operate at different conduction angles than DC
TRIGGERING
PARAMETER SYMBOL TEST CONDITIONS
VALUES UNITS
TYP. MAX.
Maximum peak gate power PGM TJ = TJ maximum, tp ≤ 5 ms 16 W
Maximum average gate power PG(AV) TJ = TJ maximum, f = 50 Hz, d% = 50 3
Maximum peak positive gate current IGM
TJ = TJ maximum, tp ≤ 5 ms
3.0 A
Maximum peak positive gate voltage + VGM 20 V
Maximum peak negative gate voltage - VGM 5.0
DC gate current required to trigger IGT
TJ = - 40 °C
Maximum required gate trigger/
current/voltage are the lowest
value which will trigger all units
12 V anode to cathode applied
200 -
mATJ = 25 °C 100 200
TJ = 125 °C 50 -
DC gate voltage required to trigger VGT
TJ = - 40 °C 1.4 -
V
TJ = 25 °C 1.1 3.0
TJ = 125 °C 0.9 -
DC gate current not to trigger IGD
TJ = TJ maximum
Maximum gate current/
voltage not to trigger is the
maximum value which will not
trigger any unit with rated VDRM
anode to cathode applied
10 mA
DC gate voltage not to trigger VGD 0.25 V
THERMAL AND MECHANICAL SPECIFICATIONS
PARAMETER SYMBOL TEST CONDITIONS VALUES UNITS
Maximum operating junction
temperature range TJ- 40 to 125 °C
Maximum storage temperature range TStg - 40 to 150
Maximum thermal resistance,
junction to heatsink RthJ-hs
DC operation single side cooled 0.042
K/W
DC operation double side cooled 0.021
Maximum thermal resistance,
case to heatsink RthC-hs
DC operation single side cooled 0.006
DC operation double side cooled 0.003
Mounting force, ± 10 % 24 500
(2500)
N
(kg)
Approximate weight 425 g
Case style See dimensions - link at the end of datasheet A-24 (K-PUK)
ΔRthJC CONDUCTION
CONDUCTION ANGLE
SINUSOIDAL
CONDUCTION
RECTANGULAR
CONDUCTION TEST CONDITIONS UNITS
SINGLE SIDE DOUBLE SIDE SINGLE SIDE DOUBLE SIDE
180° 0.003 0.003 0.002 0.002
TJ = TJ maximum K/W
120° 0.004 0.004 0.004 0.004
90° 0.005 0.005 0.005 0.005
60° 0.007 0.007 0.007 0.007
30° 0.012 0.012 0.012 0.012