Manual Switches AML Series
Mounting Dimensions (For Reference Only)
Honeywell1SensingandControl11-800-537-6945USA1F1-815-235-6847International11-800-737-3360Canada59
AML11/12 and 21/22 SWITCHES Note: Top of full guard bezel housing AML27 SWITCHES
AML41C/D and AML42C INDICATORS .19/5,0 from panel.
PUSHBUTTONS KEYLOCK
For terminal locations, see page 61.
For terminal locations, see page 62.
AML14/16 and AML24/26 SWITCHES AML13/15 and 23/25 SWITCHES
ROCKERS PADDLES
For terminal locations, see page 61, 62. For terminal locations, see page 61, 62.
AML41 INDICATOR AML42 INDICATOR TERMINAL TYPES
LENS STYLE MINIATURE
For terminal locations, see page 62.
NOTE
1 Dimensions are mm or mm/IN
IN
Solder Hole will accept two #22 AWG
Stranded Conductor (per NEMA publication
DC-2 1976)
Manuals
Manual Switches AML Series
Mounting Dimensions (For Reference Only)
60Honeywell1SensingandControl11-800-537-6945USA1F1-815-235-6847International11-800-737-3360Canada
AML31/32 SWITCHES AML34/36 SWITCHES
PUSHBUTTON ROCKER
AML33/35 SWITCHES TERMINAL LOCATIONS
PADDLE PUSHBUTTON ROCKER AND PADDLE
PANEL CUTOUT FOR SINGLE-STATION
FRONT-OF-PANEL MOUNTING
Recommended panel thickness: .060-.187/1,52-4,75
NOTES
1 Dimensions are mm or mm/IN
IN
Manufacturers logo on this side of housing
Solder Hole Will Accept One #14 AWG Stranded Conductor
(Per NEMA Publication DC-2 1976)
PANEL PUNCH FOR AML SERIES
A panel punch is manufactured by Greenlee-Textron Tool Co.,
Rockford, IL (815-926-3011).
Manual Switches AML Series
Mounting Dimensions (For Reference Only)
Honeywell1SensingandControl11-800-537-6945USA1F1-815-235-6847International11-800-737-3360Canada61
TERMINAL LOCATIONS FOR AML10 SWITCHES
PUSHBUTTONS
Solder and Quick-Connect Printed Circuit
Illuminated devices shown (non-illuminated devices do not have lamp terminals).
ROCKERS AND PADDLES
Solder and Quick-Connect Printed Circuit
One Integrated Circuit Two Integrated Circuits One Integrated Circuit Two Integrated Circuits
Illuminated devices shown (non-illuminated devices do not have lamp terminals)
TERMINAL LOCATIONS FOR AML41 INDICATORS
Solder and Quick-Connect
1 Incandescent
Lamp Circuit
1 Incandescent
Lamp Circuit
2 Incandescent
Lamp Circuits
2 Incandescent
Lamp Circuits
1-3 Incandescent
Lamp Circuits
Printed Circuit
1 Incandescent 1 Incandescent 2 Incandescent 2 Incandescent 1-3 Incandescent
Lamp Circuit Lamp Circuit Lamp circuits Lamp Circuits Lamp Circuits
TERMINAL LOCATIONS FOR AML42 INDICATORS
Solder and Quick-Connect Printed Circuit
1 LED Circuit 1 LED Circuit 1 LED Circuit 1 LED Circuit
NOTE
1 Dimensions are MM or MM/IN
IN
Manufacturer’s logo on this side of
housing
4 Lamp terminals are not provided for
non-illuminated devices
positive terminal ident. (+) marked this
side of housing
1 lamp termination identified by
‘‘
B’’.
2 lamp termination identified by
‘‘
A’’
and
‘‘
C’’.
Manuals
Manual Switches AML Series
Mounting Dimensions (For Reference Only)
62Honeywell1SensingandControl11-800-537-6945USA1F1-815-235-6847International11-800-737-3360Canada
TERMINAL LOCATIONS FOR AML20 SWITCHES
PUSHBUTTON SWITCHES
Solder or Quick-Connect
Terminal identification marked on each adja-
cent side of housing KEYLOCK SWITCHES
Solder or Quick-Connect
Printed Circuit
1 Pole 4 Pole2 Pole
PUSHBUTTON SWITCHES
Printed Circuit
1 Pole 2 Pole
4 Pole
1 Pole 2 Pole
ILLUMINATED ROCKERS AND PADDLES
Solder or Quick-Connect
Printed Circuit
1 Pole 2 Pole 1 Pole 2 Pole
NON-ILLUMINATED ROCKERS AND PADDLES
Solder or Quick-Connect Printed Circuit
1 Pole 2 Pole 4 Pole
Manual Switches AML Series
Mounting Dimensions (For Reference Only)
Honeywell1SensingandControl11-800-537-6945USA1F1-815-235-6847International11-800-737-3360Canada63
ANNUNCIATORS
AML45 SERIES
Manufacturer’s logo on this side of housing
For panel punch manufacturer, see page 60.
Manuals
Manual Switches AML Series
Mounting Dimensions (For Reference Only)
64Honeywell1SensingandControl11-800-537-6945USA1F1-815-235-6847International11-800-737-3360Canada
MULTI-STATION FRONT-PANEL MOUNTING
Panel cutouts (See page 61 for panel punch manufacturer.)
Square Switches & Indicators Rect. Switches & Indicators Annunciator
(.8) (No. of units) .045* (1.20) (No. of units) .045* (.40) (No. of units) .045*
(20,3) (No. of units) 1,14* (30,5) (No. of units) 1,14* (10,1) (No. of units) 1,14*
For each barrier, add .053/1,35 * Note: If barriers are used, do not subtract .045 in./1,14 mm from the panel cutout
formula. (.045 in./1,14mm is the allowance for the width of the bezel.)
AML61 MULTI-STATION SUBPANEL MOUNTING
Panel cutouts for AML61
Mounting Bracket
Orientation Width Length
A* in. .810
mm 20,57 (.810)(No. of units)
B in. .810
mm 20,57 (1.210)(No. of units)
C or D* in. 1.210
mm 27,94 (.810)(No. of units)
*More than two cans with mounting brackets required for strips
of more than 10 units.
AML61 MOUNTING CENTERS
Mounting Centers/Number of Cans
Mounting Bracket
Orientation 123456789101112
‘‘
A’’ or
‘‘
C’’ in. 1.285 2.095 2.905 3.715 4.525 5.335 6.145 6.955 7.765 8.575 9.385 10.195
mm 32,64 53,21 73,79 94,36 114,94 135,51 156,08 176,66 197,23 217,81 238,38 258,95
‘‘
B’’ in. 1.685 2.895 4.105 5.315 6.525 7.735 8.945 10.155
mm 42,80 73,53 104,27 135,00 165,74 196,48 227,20 257,94
‘‘
D’’ or
‘‘
E’’ in. on CL.807 1.614 2.421 3.228 4.035 4.842 5.649 6.456 7.263 8.070 8.877
mm on CL20,50 41,00 61,49 81,99 102,49 122,99 143,48 163,98 184,48 204,98 225,48
Tolerance J±.015
C
D
E
B
A
Manual Switches AML Series
Mounting Dimensions (For Reference Only)
Honeywell1SensingandControl11-800-537-6945USA1F1-815-235-6847International11-800-737-3360Canada65
AML75 PANEL SEAL ACCESSORY
Panel cutouts
Multiple panel sealed units should not be
mounted together in a single elongated
slot, since this would create an unsealed
space between each unit.
Side-by-side mounting can be achieved,
per the center-to-center dimensions
shown in the drawing. (Dotted lines in-
dicate the seal bases which are abutting
at front of panel.)
AML75 seals are not designed for use
with the AML61 mounting system.
NOTE: Suggested cutout dimensions are
based on an .125N/3,18 mm panel thick-
ness. Individual preferences for inpanel fit
may require measurement of assemblies
before panels are cut.
AML76 SWITCH GUARD ACCESSORY
PANEL CUTOUTS
Manuals