G
G180
www.sti.com/info
Universal Tongue-Operated Safety
Interlock Switch
• Strongandversatile—thecompactsizeofthestrong,glass-lledpolyes-
terhousingallowsthispopularswitchtobeusedinmostapplications
• NEMA6enclosureenablestheXT5009towithstandwaterwashdown
cleaning
• Rotatableheadgivesfourpossibleactuatorentrypointsforversatile
installation.Ablankingplugissuppliedfortheunusedentry.
• Smallswingradiusallowsuseondoorswithaswingradiusassmallas
2.5in.whenusingtheoptionalexibleactuatorwithalignmentguide
• Vibrationresistant—preventingunwantedopeningofguarddoorson
vibratingmachines
• Longlife—theXT5009,withitsstainlesssteelactuator,isdesignedfora
minimumoftwomillionactuations
• ARapidDeliveryProduct:Selectmodelsareavailableforshipment
todayorwithin3to5days
Safety Interlock Switches
XT5009 XT5009
For full product information, visit www.sti.com. Use the SpeedSpec Code or scan the QR Code for quick access to the specific web page.
Electrical All Models XT5009-02SC2 & XT5009-02SC6
Classication: EExd11CT6
ContactCongurations: 2N/C
SafetyContacts: 2N/Cpostivebreak
RatedVoltage: 250VAC 250VDC
RatedCurrent: 5AAC 0.25ADC
ACRatings: 250V 125V
Resistive: 5A 5A
Inductive: 2.5A 3A
DCRatings: 250V 125V 75V 30V
Resistive: 0.25A 0.5A 1A 7A
Inductive: 0.1A 0.2A 1A 5A
ElectricLife: Dependentonloading
Mechanical - Contact Block
OperatingForce: 3.6N(0.36lb.)
ReleaseForce: 0.4N(0.09lb.)
Pre-travel: 0.8mm(0.03in.)
Over-travel: 0.6mm(0.02in.)
ReturnTravel: 1.1mm(0.04in.)
DifferentialTravel: 0.5mm(0.02in.)
ReleaseTravel: 0.2mm(0.008in.)
PositiveBreakTravel: 0.4mm(0.016in.)
Mechanical
Mounting: Anyposition
MountingHardware: 2xM5screws
CaseMaterial: ULlisted,glass-lledpolyester
ActuatorMaterial: Stainlesssteel
WiringConnection: Variouscablelengths
Weight: 160g(5.6oz.)
Color: Red
MechanicalLife: 2x106minimum
Environmental
Protection: IP67(NEMA6)
OperatingTemperature: -20to75°C(-13to158°F)
Cleaning: Waterwashdown
Compliance
Standards: EN1088
Approvals/Listings: CEmarkedforallapplicabledirectives
Specicationsaresubjecttochangewithoutnotice.
Note:ThesafetycontactsoftheSTIswitchesaredescribedasnormallyclosed(N/C)—i.e.,withtheguardclosed,
actuatorinplace,andthemachineabletobestarted.
Explosion-Proof
Classification
Theexplosion-proofmodels
ofsafetyinterlockswitchesare
specicallydesignedforpotentially
explosiveatmosphereswhile
retainingthefeaturesandoperating
characteristicsoftheconventional
models.
Asealedameproofcontact
blockmakestheexplosion-proof
interlockswitchessuitableforuse
inEuropeanZone1andZone2
environments,whicharetypical
ofthosefoundinthechemical
andpetrochemicalindustries.
Allswitchesareclassiedby
theEuropeanmethodasEExd
llCT6.Forafullexplanationof
theclassicationmethod,see
“HazardousLocationRating
SystemsforInterlockSwitches”
intheExpertAreaSectionofthis
catalog.
These switches are not
suitable for use in atmospheres
containing Group I gases, e.g.,
methane (firedamp).
These switches DO NOT
meet all conditions of the US
classification of Class I, Div 1,
due to the differences between
European and US classification
methods. In the US and
Canada, these products can
be used in areas classified as
Class I, Division 2 in Groups
A (acetylene), B (hydrogen), C
(ethylene) and D (propane).
ConformstoEN1088
Specifications