Limit and Enclosed Switches SL1 Series
Compact Limit Switches
A84Honeywell1Sensing and Control11-800-537-6945 USA1F1-815-235-6847 International11-800-737-3360 Canada
CIRCUITRY AND ELECTRICAL RATING
Listing Rating Contact
SL1-65A-125, 250VAC Silver
Single-Pole SL1-6K0.1A-125VAC Gold Clad Cross Point
Double-Throw 0.1A-30VDC
ORDER GUIDE AND MOUNTING DIMENSIONS
UL/CSA listings available by adding ‘‘2’’ to catalog listing.
Example: SL1-A2
UL Recognized, file #E37559
CSA Certified, file #LR61344, LR21098, LR47132, LR61643
ROLLER PLUNGER
Catalog SL1-A
Listing SL1-AK
O.F. (max.) 1,200 g
R.F. (min.) 500 g
P.T. (max.) 1.5 mm
O.T. (min.) 3 mm
D.T. (max.) 0.1 mm
O.P. 31.4 mm
CROSS ROLLER PLUNGER
Catalog SL1-D
Listing SL1-DK
O.F. (max.) 1,200 g
R.F. (min.) 500 g
P.T. (max.) 1.5 mm
O.T. (min.) 3 mm
D.T. (max.) 0.1 mm
O.P. 31.4 mm
Characteristics: O.F. - Operating Force; R.F. - Release Force; P.T. - Pretravel; O.T. - Overtravel; D.T. - Differential Travel; N - Newtons
FEATURES
1Ideal source of replacement parts for
imported machine tools or transplant
factories
1NEMA 3,4, 13 and IEC IP 67 sealing
1Smaller size saves space
1Rugged Zinc diecast housing
1Wide product selection to suit many
applications
1Snap-in terminal enclosure makes
mounting and wiring easy
1Temperature ranges: Standard –10 to
+70°C (14 to 158°F); Low temp. with
roller lever –40 to +70°C (–40 to 158°F);
Low temp. with roller plunger –50 to
70°C (–60 to +158°F)
SL1 series compact limit switches are
sealed, sensitive, and have a long life. The
compact size makes them suitable for the
total miniaturization of machinery or equip-
ment.
Versions are available with: gold-clad cross-
point contacts, prewiring, lamp indications,
seal boots with roller plungers, and a variety
of actuating possibilities.
For rapid response – off the shelf service,
all bold face listings are normally stocked
items.
Note: Conduit will seal to cable diameters
from 5.8mm to 9.6mm.