Power Supplies IP67 SCP-X Extreme Environment Series The SolaHD IP67 SCP-X power supplies provide the versatility and cost-efficiency to deliver reliable distributed and remote field power to machine controls. Mounts directly on the machine or production line eliminating the complexity and cost of unnecessary enclosures and excess wiring. Quick change connectors simplify connectivity for distributed I/O devices on industrial machinery. These Class II Listed, 24 Vdc power supplies are available in single and dual 100 Watt models and are perfect for automotive, packaging and automated distribution applications. Control Output Models Designed for Control Power applications where a grounded power supply output is required. * Input connector: 3-PIN IP67 molded plug externally threaded with 7/8"-16 UN mounting thread. E61379 E137632 * Safety approved for AC and DC universal input * Output connector: 4-PIN IP67 molded receptacle internally threaded with 7/8"-16 UN mounting thread. * Reliable operation from -40C to 60C without derating * DC OK Green LED Isolated Output Models * Worldwide approvals Designed for application where an isolated output from ground is required such as DeviceNetTM. * Five year limited warranty Certifications and Compliances * Input connector: 3-PIN IP67 molded plug externally threaded with 7/8"-16 UN mounting thread. * Output connector: 4-PIN IP67 molded receptacle internally threaded with 7/8"-16 UN mounting thread. Features * IP66/67 rated versatile enclosure - IEC/EN60950-1, 2nd Edition * RoHS Compliant * 24 Vdc, 100-240 Vac, up to four outputs at 3.8A Nominal Current (per pair for dual models) * Class II Listed power supply for stand alone applications * Can be mounted in any orientation without limitation Selection Table Catalog Number SCP 100S24X-CP1 SCP 102D24X-D02 Related Products * SDN Series Recommended Electrical Connections/Cordsets 1 Output Current Output Voltage 3.8 A SCP 100S24X-DVN1 SCP 102D24X-C02 Listed, Ind. Control Equipment, E61379, ITE, E137632 - UL 508, CSA C22.2 No. 107.1 -UL 60950-1/CSA C22.2 No. 60950-1, 2nd Edition * - Low Voltage Directive * Output Power Input 3-PIN Connections Output 4-PIN Connections 100 W Daniel Woodhead P/N 103000A01FXX0 (2) or Harting P/N 21 04 516 23XX (4) Turck P/N RSM46*M (3) or Harting P/N 21 04 516 14XX (4) 24 Vdc 7.6 A total (3.8 A max. per pair) 2 x 100 W 1. Connections to be provided by the user. 2. XX is the length of the cordset in feet. 3. * is the length of the cordset in meters 4. XX is the length of the cordset in meters. 146 Visit our website at www.emerson.com or contact Technical Services at (800) 377-4384 with any questions. (c) December 2018 Power Supplies SCP100S24X-CP1 and SCP100S24X-DVN1 Mechanical Diagrams Electrical Connections 7.16" (181.8 mm) 6.52" (165.6 mm) Input Output 50/60/400 Hz 100-240 V ac 100-353 V dc, 0.7-1.6 A 24 V dc, 3.8 A, Class II Power Supply 5.54" (140.8 mm) TYP 4.22" (107.1mm) SOLA 4.85" (123.3 mm) SCP 100S24X-CP1 1 = Ground 2 = Power 3 = Neutral - 2 1 1 = +24 V dc 2 = +24 V dc 3 = 0 V dc (1) 4 = 0 V dc (1) 2 4 1 3 1 = +24 V dc 2 = +24 V dc 3 = Ground (2) 4 = -V dc (3) 2 4 1 3 SCP 100S24X-DVN1 1 = Ground 2 = Power 3 = Neutral Top View 3 Side View 3 2 1 NOTES: 1.86" (47.3 mm) 1. 0 Vdc connections are internally bonded to ground. 2. Ground is isolated from V-. 3. Vdc is isolated from ground. -Vdc is a separately derived source, so it is permissible to bond to ground if required in the application. Bottom View SCP102D24X-CO2 and SCP102D24X-DO2 Mechanical Diagrams Electrical Connections 7.16" (182.0 mm) 6.52" (165.6 mm) Input Output 50/60/400 Hz 100-240 Vac / 2.4 - 1.4A 100-353 Vdc / 2.4 - 0.7A 24 Vdc, 3.8 A (x2), Class II 6.14" (156.1 mm) TYP Power Supply 4.86" (123.5 mm) SOLA 4.22" (107.1 mm) SCP 102D24X-C02 Top View Side View 1 = Ground 2 = Power 3 = Neutral 1 2 3 4 1 = Ground 2 = Power 1 3 = Neutral DC 1 2 INPUT 50/60/400 Hz 100-240 V 3ac / 2.4-1.4 4A 100-353 V dc /DC 2.4-0.7 A 2 1 = +24 V--2 = +24 V--3 = 0 V--4 = 0 V--- 2 DC 11 OUTPUT 4 24 V--- /3.8 A (x2) CLASS 2 2 1 3 DC 12 1 SCP 102D24X-D02 2 1 3.35" (85.2 mm) 3 4 3 1 = Ground 2 = Power 3 = Neutral 1 = Ground 2 = Power 1 3 = Neutral 3 DC 1 4 2 INPUT 50/60/400 Hz 100-240 V 3ac / 2.4-1.4 4A 100-353 V dc /DC 2.4-0.7 A 2 3 4 1 = +24 V--2 = +24 V--3 = GROUND 4 = - V--- 2 DC 11 OUTPUT 4 24 V--- /3.8 A (x2) CLASS 2 2 1 3 DC 12 1 Bottom View Visit our website at www.emerson.com or contact Technical Services at (800) 377-4384 with any questions. (c) December 2018 147 Power Supplies IP67 SCP-X Specifications Catalog Number Descriptions SCP 100S24X-CP1 SCP 100S24X-DVN1 SCP 102D24X-C02 SCP 102D24X-D02 Input Any voltage from 100 to 240 Vac Input 85 - 264 Vac Universal Input 100 - 353 Vdc Nominal Voltage -AC Range -DC Range Nominal Current 1 -Inrush current max. Power Factor Correction 2 Frequency 1.6 A / 0.7 A 2.4 - 1.4 A / 2.4 - 0.7 A Typ. <30 A 0.95 50/60/400 Hz Output 35 V 25-25.5 Vdc, autorecovery 24 Vdc < +/-2% overall < 0.5% < 0.5% < 1% 24.5 V +/-1% < 50 mVpp Power Back Immunity Overvoltage Protection Nominal Voltage Tolerance - Line Regulation - Load Regulation - Time & Temp. Drift Input Voltage Setting Ripple 3 Total Nominal Current 3.8 A 7.6 A Total (3.8 A max. per pair) Holdup Time > 50 ms (Full load, 100 Vac Input @ Tamb=+25C) to 95% output voltage Emissions 4 EN61000-6-3, EN61000-6-4, EN55011 Group 1, Class B, EN55022 Class B, EN61000-3-2, EN61000-3-3 Immunity 4 EN61000-6-1, EN61000-6-2, EN55024, IEC61000-4-2, IEC61000-4-3, IEC61000-4-4, IEC61000-4-5, IEC61000-4-6, IEC61000-4-8, IEC61000-4-11, SEMI F47 Sag Immunity General Temperature Humidity Altitude Vibration Shock Warranty MTBF General Protection/Safety Storage: -40 to +85C, Operation: -25 to +60C full power with linear Storage: -40 to +85C, Operation: -40 to +60C full power with linear derating to half power from +60 to +70C. derating to half power from +60 to +70C. No forced air required. Operation up to 100% load permissible No forced air required. Operation up to 100% load permissible with sideways or front-side-up mounting orientation. with sideways or front-side-up mounting orientation. Up to 100% RH with condensation 0 to 3,000 m (0 to 10,000 ft.) 1 g non-operating swept sine over 10-500 Hz (IEC 60068-2-6). Non-operating random vibration test: 1.87 g over 10-500 Hz (IEC 60068-2-64). Operating random vibration test: 0.15 g over 5-100 Hz (IEC 60068-2-64) Non-operating: 30 g peak, 18 ms half-sine pulse (IEC 68-2-27). Operating: 4 g peak, 22 ms half-sine pulse (IEC 68-2-27) 5 Year Limited Warranty >800,000 hours according to Telcoredia/Bellcore SR-332 Issue 1, >800,000 hr. according to Telcoredia/Bellcore SR-332 Issue 3, (Vin 120 Vac, Tamb = 40C) (Vin 120 Vac, ambient temp. = 40C) Protected against continuous short-circuit, continuous overload, Protected against continuous short-circuit, continuous overload, and continuous open circuit. Protection NEC Class II (IEC536), continuous open circuit. Protection Class I. degree of protection IP66/IP67 versatile (IEC60529). Safety extra low voltage circuits: SELV (acc. EN60950). Safety extra low voltage circuits: SELV (acc. EN60950-1). DC OK LED Status Indicators - Visual Installation Fusing -Input Internally fused, fuses not replaceable Electronically current limited to meet NEC Class II per UL1310 -Output Chassis mounted using integral mounting tabs. Recommended Screw Size: M4 x 0.7. Tightening Torque: 1N-m Mounting An accessible disconnect device shall be installed external to the equipment. Input: 3-PIN IP67 molded plug (quick disconnect). Output: 4-PIN IP67 molded receptacle (quick disconnect). Use UL 758 wire rated min. 24 V, VW-1/FT-1, max. 3.05 m. Connections IP66/67 versatile ingress protection; also meets UL50 Type 4X enclosure Case Min. Required Free Space H x W x D - in (mm) Weight - lbs (kg) 0.39 in. (10 mm) all sides but base 4.73 x 7.00 x 1.80 (120.1 x 177.8 x 45.7) 2.2 (1.0) 1 in. (25 mm) all sides but base 4.73 x 7.00 x 3.27 (120.1 x 177.8 x 83.0) 3.3 (1.5) 1. Input current ratings are specified with low input, line conditions, worst case efficiency values and power factor. 2. Power Factor Correction at 50/60 Hz only. 3. Ripple/noise is stated as typical AC values when measured with a 20 MHZ bandwidth scope and 50 Ohm termination. 4. Emissions and immunity are met by individual power supply modules. 148 Visit our website at www.emerson.com or contact Technical Services at (800) 377-4384 with any questions. (c) December 2018