NPC-1210SeriesSpecications
Medium Pressure Sensors
Pressure Ranges
•Gaugeanddierential:
•5psi(34kPa,0.34bar)
•15psi(100kPa,1.0bar)
•30psi(210kPa,2.1bar)
•50psi(340kPa,3.4bar)
•100psi(690kPa,6.9bar)
•Absolute:
•15psi(100kPa,1.0bar)
•30psi(210kPa,2.1bar)
•50psi(340kPa,3.4bar)
•100psi(690kPa,6.9bar)
•Forotherpressureranges,pleasecontactGE.
Parameter Value Units Notes
Environmental
TemperatureRange
Operating –40to125 °C (-40°to257°F)
Compensated 0to60 °C (32°Fto140°F)
Storage –55to150 °C (–67to302°F)
Mechanical
Weight 2.5 g (0.005lb)
Media
Compatibility
Compatiblewith
exposedmaterials
7
Positive
dierential and
gauge ports
Dry gases
only
Absolute.
negative
dierential ports
Dry gases
only
Parameter Units Minimum Typical Maximum Notes
Performance Parameters *
FSOutput(FSO) mV 75 100 150 2,3
ZeroPressure
Output
mV -2 — 2 3
Linearity %FSO -0.1 — 0.1 4,8
Pressure
Hysteresis
%FSO -0.1 — 0.1
InputImpedance W 2500 4000 6000
Output
Impedance
W 4000 5000 6000
Thermal
Accuracy–Span
%FSO -0.5 — 0.5 3,5,8
Thermal
Accuracy–Zero
%FSO -0.5 — 0.5 3,5,8
Temperature
Coecient–
Resistance
%/°C — 0.2 — 5
Thermal
Hysteresis–Zero
%FSO — 0.1 — 5
InputExcitation mA — 1.5 2.0
Pressure
Overload
Rated — — 3X 6
* 1. Supply current = 1.5 mA and ambient temperature = 77°F (25°C),
unless otherwise noted.
2. Output span of unamplied sensor.
3. Compensation resistors are an integral part of the sensor package;
no additional external resistors are required. Pins 7 and 8 must be kept open.
The NPC-1210 is interchangeable only when used with the gain set resistor
shown in the schematic diagram. Maximum gain-set resistor mismatch is 2%.
4. Best t straight line.
5. Temperature range 32°F to 140°F (0°C to 60°C), reference to 77°F (25°C).
6. 3X or 200 psi (13.78 bar) maximum, whichever is less.
7. Exposed materials are pyrex, ceramic, silicon, epoxy, RTV, and stainless steel.
8. 5 psi (0.34 bar) spec.: Linearity: 0.25 ±%FSO, TC-span:
0.75 ±%FSO, TC-zero: 0.75 ±%FSO.otherwise noted.
Low Pressure Sensors
Pressure Ranges
• Gaugeanddierential:
•10inH20(2.5kPa,0.025bar)
•1psi(6.9kPa,0.069bar)
Parameter Value Units Notes
Environmental
TemperatureRange
Operating –40to125 °C (-40°to257°F)
Compensated 0to60 °C (32°Fto140°F)
Storage –55to150 °C (–67to302°F)
Mechanical
Weight 2.5 g (0.005lb)
Media
Compatibility
Compatiblewith
exposedmaterials
7
Positive
dierential and
gauge ports
Dry gases
only
Absolute.
negative
dierential ports
Dry gases
only
Parameter Units Minimum Typical Maximum Notes
Performance Parameters *
FSO10inH2O mV 25 50 70 2,3
FSO1psi mV 50 75 110 2,3
ZeroPressure
Output
mV -2 — 2 3
Linearity %FSO -0.5 — 0.5 4
Pressure
Hysteresis
%FSO -0.1 — 0.1
InputImpedance W 2500 4000 6000
Output
Impedance
W 4000 5000 6000
Thermal
Accuracy–Span
%FSO -1.0 — 1.0 3,5
Thermal
Accuracy–Zero
%FSO -1.25 — 1.25 3,5
Temperature
Coecient–
Resistance
%/°C — 0.22 — 5
Thermal
Hysteresis–Zero
%FSO — 0.1 — 5
InputExcitation mA — 1.5 2.0
Pressure
Overload
psi(bar) 5(0.34) — — 6