Keysight Technologies 6000 Series Oscilloscopes Lab Scope Performance at a Portable Scope Price Data Sheet Introduction The standard for high-performance portable scopes A wide selection lets you choose the 6000 Series model that best matches your needs. Bring your toughest problems into focus with the right combination of features and performance If you work with analog, digital and serial circuitry, Keysight Technologies, Inc. 6000 Series oscilloscopes give you the tools you need for the fastest debug of your design. Mixed signal oscilloscope (MSO) models and the traditional 2and 4channel digital storage oscilloscope (DSO) models are optimized with the capabilities you need for verifying and debugging designs that include embedded serial, microcontrollers, DSPs, FPGAs, ADCs and DACs. Mixed analog and digital channel triggering and analysis -- See all aspects of your design in one box - analog, digital and serial -- Trigger across both slow analog and fast digital signals Powerful applications suites available -- I2C, SPI and USB standard triggering and decode -- CAN, LIN and FlexRay triggering and decode -- Rapid Xilinx and Altera FPGA debug Get superior insight into your design challenges with integrated analog, digital and serial test. The performance and problem solving tools you need to more quickly debug your analog, digital and serial design challenges, in a single instrument. -- 100 MHz, 300 MHz, 500 MHz and 1 GHz bandwidths -- 2 or 4 analog channels -- Optional 16 digital channels -- MegaZoom III memory and display technology -- Up to 8 Mpts acquisition memory -- Up to 100,000 waveforms per second real-time update rate -- High-definition XGA (1024 x 768) display with 256 levels of intensity grading -- Up to 12 bits of vertical resolution, even in single-shot acquisitions -- Complete connectivity - standard -- USB (3 ports) -- LAN -- GPIB -- XGA display out -- Full remote control, including web browser -- LXI Class C compliant -- Secure environment option -- Battery option 03 | Keysight | 6000 Series Oscilloscopes - Data Sheet Your design has analog, digital and serial signals, shouldn't your scope? Analog: Up to 1 GHz bandwidth and up to 4 GSa/s sample rate The 6000 Series analog channels provide faster identification of the most elusive problems. -- Revolutionary high-resolution display. Engineered with a XGA display and 256 levels of intensity (color grading), see a precise representation of the analog characteristics of the signals you're testing. Equipped with the industry's fastest update rate at 100,000 waveform/s update rate, you'll capture and see infrequent events. -- MegaZoom III technology. MegaZoom III responsive deep memory captures long, nonrepeating signals and maintains high sample rates, allowing you to quickly zoom in on areas of interest. Sample rate and memory depth go hand-in-hand. Deep memory in oscilloscopes sustains a high sample rate over longer time spans. Digital: 16 digital timing channels with mixed signal triggering Capture a mix of analog or digital signals. Compare multiple cycles of digital signals with slower analog signals. -- 16 high-speed timing with up to 2 GSa/s deep memory timing. Use the timing channels to evaluate control signal relationship. Or capture and view data buses up to 16 bits wide. Display individual signals or bus waveforms in hex or binary. -- Mixed signal trigger. Trigger across any combination of analog and digital signals simultaneously. See precise analog measurements timed with exact digital content, all in one box. -- Applications for digital channels. Designing with Altera or Xilinx FPGAs? Use FPGA dynamic probe for rapid internal FPGA measurements. Using I2C or SPI? Use the digital signals from a 4-channel MSO to acquire and decode these serial buses. Serial: Hardware-accelerated decode and trigger for I2C, SPI, CAN, LIN and FlexRay Capture long streams of serial data and gain fast insight into the problem. The Keysight 6000 Series oscilloscopes provide the best serial capabilities in its class. -- Serial bus triggering and decoding. Display responsive, on-screen decode of serial bus traffic. Isolate specific events with pinpoint accuracy. Show decode to validate serial bus activity in real-time. -- Hijack infrequent errors. Hardwareaccelerated decoding increases your probability of capturing elusive events. Keysight oscilloscopes can help you catch that intermittent problem before it becomes an intermittent customer complaint or quality concern. -- Easily capture enough serial data to see all of the details. Use deep memory to capture serial data stream over a long period of time. 04 | Keysight | 6000 Series Oscilloscopes - Data Sheet If you haven't purchased an Keysight oscilloscope lately, why should you consider one now? Leading-edge technology The 6000 Series oscilloscopes incorporate third generation MegaZoom III technology blocks - responsive deep memory, fast update rates with minimal "dead time" and analog-like display systems - and deliver them in a compact package. Industry-leading customer support As the world's leading Test and Measurement vendor, Keysight maintains the largest network of sales engineers, application engineers, support engineers and technicians. From pre-sales collaboration, to calibration, to training and consulting, to repair and servicing, Keysight stands with you throughout the life of your product. It's no accident that Keysight has such loyal customers. Don't take our word for it Compare the 6000 Series with your current bench scope. Or compare it to one of our competitors' newest scopes. You'll see why Keysight has been the fastest-growing oscilloscope supplier since 2001 (source: Prime Data 2005 Test Instrument Industry Service Market Share Analysis). Model Bandwidth Maximum sample rate Memory depth Scope channels DSO6012A 100 MHz 2 GSa/s 2 Mpts, 8 Mpts optional 2 MSO6012A 100 MHz 2 GSa/s 2 Mpts, 8 Mpts optional 2 DSO6014A 100 MHz 2 GSa/s 2 Mpts, 8 Mpts optional 4 MSO6014A 100 MHz 2 GSa/s 2 Mpts, 8 Mpts optional 4 DSO6032A 300 MHz 2 GSa/s 2 Mpts, 8 Mpts optional 2 MSO6032A 300 MHz 2 GSa/s 2 Mpts, 8 Mpts optional 2 DSO6034A 300 MHz 2 GSa/s 2 Mpts, 8 Mpts optional 4 MSO6034A 300 MHz 2 GSa/s 2 Mpts, 8 Mpts optional 4 DSO6052A 500 MHz 4 GSa/s 2 Mpts, 8 Mpts optional 2 MSO6052A 500 MHz 4 GSa/s 2 Mpts, 8 Mpts optional 2 DSO6054A 500 MHz 4 GSa/s 2 Mpts, 8 Mpts optional 4 MSO6054A 500 MHz 4 GSa/s 2 Mpts, 8 Mpts optional 4 DSO6102A 1 GHz 4 GSa/s 2 Mpts, 8 Mpts optional 2 MSO6102A 1 GHz 4 GSa/s 2 Mpts, 8 Mpts optional 2 DSO6104A 1 GHz 4 GSa/s 2 Mpts, 8 Mpts optional 4 MSO6104A 1 GHz 4 GSa/s 2 Mpts, 8 Mpts optional 4 Start with: -- DSO -- 2 Mpts standard memory depth Upgrade to: User installable Upgrade in 10 minutes -- MSO -- 8 Mpts deep memory Logic channels 16 16 16 16 16 16 16 16 05 | Keysight | 6000 Series Oscilloscopes - Data Sheet Other nice features High resolution mode Trig Out Offers up to 12 bits of vertical resolution in real-time, single-shot mode. This is accomplished by serially filtering sequential data points and mapping the filtered results to the display when operating at base settings greater than 10s/div. Provides an easy way to synchronize your scope to other instruments. Use the Trig Out port to connect your scope to a frequency counter for more accurate frequency measurements or to cross trigger other instruments. Help is at your fingertips Autoscale An embedded help system - available in six languages - gives you quick answers if you don't understand a feature. Simply press and hold the corresponding front-panel key, and a screen pops up to explain its function. Displays all active signals, and automatically sets the vertical, horizontal and trigger controls. Waveform math with FFT Analysis functions include subtract, multiply, integrate, and differentiate, as well as Fast Fourier Transforms (FFT). with QuickMeas Pressing [QuickMeas] brings up the last four measurements selected. Cursors automatically track the most recently selected measurement. Peak detect HDTV trigger 250 ps on 500MHz models, 500 ps on 300MHz models and 1 ns on 100MHz models helps you find narrow glitches. The 6000 Series supports analog HDTV/EDTV triggering for standards like 1080i, 1080p, 720p and 480p as well as standard video triggering on any line within a field, all lines, all fields, odd or even fields for NTSC, SECAM, PAL and PAL-M video signals. AutoProbe interface Automatically sets probe attenuation factors and provides power for selected Infiniium active probes, including the award-winning 1130A 1.5GHz InfiniiMax differential active probe and 1156A 1.5GHz single-ended active probe systems. Serial triggering Set up a serial bus trigger for I2C, SPI and USB. Easy software upgrades 5-digit hardware counter Measures frequency up to the bandwidth of the scope. Press and hold a key for instant help. 23 automatic measurements System software is stored in Flash ROM that can be upgraded from the scope's built-in USB port or LAN. You can find the latest system and IntuiLink Data Capture software at www.keysight.com/find/MSO6000sw. FFT allows you to view the spectral content of this unfiltered sine wave. Display signals can be displayed individually or as overlayed bus values. 06 | Keysight | 6000 Series Oscilloscopes - Data Sheet Why does deep memory matter? There is no better way to experience the superiority of the new Keysight 6000 Series scopes than seeing one in action on your bench to measure your signals yourself. We can arrange for you to try out a new MSO6000A MSO. Contact your nearest Keysight sales office or visit the MSO6000A home page at www.keysight.com/find/MSO6000. Contact Keysight today to request an evaluation. See more time This is the most easily understood use of deep memory. The more samples that you acquire, the more time that you can see at a particular sample rate. Long capture times give you better visibility into cause-effect relationships in your design, which greatly simplifies root-cause debugging. It also allows you to capture start-up events (like the start-up sequence below) in a single acquisition. You don't have to stitch together multiple acquisitions or set precise triggering conditions. Spend less time finding events, and more time analyzing them. See more details The relationship between memory depth and acquisition rate isn't as obvious. All scopes have a "banner" maximum sample rate specification, but many can only sustain these rates at a few timebase settings. In the case of an oscilloscope with a 5 GSa/s acquisition rate and 10 k of memory, those 10,000 points can only fill 2 Ms of time. Since scopes have 10 time divisions, the sample rate drops at any time setting below 200 ns/div. As a result, if you look at "slow/fast" events like a modulated signal, you run the risk of aliasing your signal. Or you may simply miss out on important signal details when you zoom in on it. Deep memory oscilloscopes let you sustain a high sample rate over longer periods of time. Always fast, always on MegaZoom III is the third generation of the fast and deep memory architecture that Keysight introduced in 1996. It's not a special mode, unlike other deep-memory oscilloscopes. You have access to your MegaZoom memory at all times. And the display will respond instantly to your commands as you scale the t/div settings or pan and zoom in the Delayed (or "zoom") window. You can learn more about MegaZoom III deep memory in Application Note 1446 - Deep Memory Oscilloscopes: The New Tools of Choice. 07 | Keysight | 6000 Series Oscilloscopes - Data Sheet Why does a fast update rate matter? This is a question that we hear frequently. If the human eye has trouble discerning above 30-50 frames per second, is there really a difference between 3,600 and 100,000 waveforms per second? If you know what you're looking for the answer is probably "no". However, if you are hunting for unknown signal anomalies or characterizing jitter, the answer is "yes". If you know that there is a glitch in your system, it's easy to capture it using a pulse-width trigger. However, if you are just browsing through your design, your chances of finding a glitch increase as the update rate increases. If a glitch occurs during the "dead time" between sample, you miss it. With MegaZoom III technology, the dead time is much smaller. A scope with a slower update rate will capture the glitch eventually (if it recurs), but most engineers and technicians don't have the time or patience to wait for their tools to catch up. Acquisition time Dead time Acquisition time Dead time Reducing the dead time between acquisitions ... If you are characterizing signal jitter, a fast update rate gives you accurate results sooner. And when the fast update rate is combined with the 6000 Series' XGA high-definition display (1024 x 768, 256 intensity levels), subtle differences in these acquisitions become obvious. And like all other aspects of MegaZoom III technology, this is a real-time acquisition mode. It's always fast, always on. Update Rate (Waveforms/Sec) Learn more about the benefits of a fast update rate by reading Application Note 1551 - Improve Your Ability to Capture Elusive Events: Why Oscilloscope Waveform Update Rates are Important. ... improves your chances of finding random events like glitches. 100000 Catch problems sooner and cover more of your debug checklist - our 100,000 waveform per second update rate helps you find intermittent problems faster than comparable scopes. 10000 1000 100 10 1 0.1 1 ns/div 5 ns/div 100 ns/div 2 s/div 50 s/div 20 ns/div 500 ns/div 10 s/div Time base MSO6000 TDS3000 WaveSurfer Comparison of waveform update rates using each scope's default real-time acquisition mode. TDS5000 08 | Keysight | 6000 Series Oscilloscopes - Data Sheet Connectivity Our customers tell us that oscilloscope connectivity is an increasingly important feature of their test instruments. That's why the 6000 Series scopes come with the most comprehensive hardware and software connectivity tools in their class. Hardware connectivity Standard ports include: -- 2 x USB host ports (for external storage and printing devices), one on the front and one on the rear -- 1 x USB device port for high-speed PC connectivity -- 10/100 Mbit LAN for Internet/Intranet connectivity -- GPIB to allow easy migration into existing test systems -- XGA Out for external monitors and projectors LXI Class C LAN eXtensions for Instrumentation (LXI) is a standards-based architecture for test systems. By specifying the interaction of system components, LXI enables fast and efficient test system creation and reconfiguration. The 6000 Series oscilloscopes follow specified LAN protocols, and adhere to LXI requirements such as a built-in Web control server, IVI-COM driver, and easy-to-use SCPI commands. The standard Keysight I/O Library Suite makes it easy to configure and integrate instruments in your system. IntuiLink toolbars IntuilLink gives you a quick way to move screen shots and data into Microsoft (R) Word and Excel. These toolbars can be installed from www.keysight.com/find/intuilink. Keysight Remote Front Panel running in a web browser Scope View logic analyzer and oscilloscope correlation Scope View enables simple timecorrelated measurements between a 6000 Series oscilloscope and an Keysight 1680/90 or 16800/900 logic analyzer. Scope and logic waveforms are integrated into a single logic analyzer waveform display for easy viewing analysis - all with a simple point-to-point LAN connection. You can also cross-trigger the instruments, automatically de-skew the waveforms, and maintain marker tracking between the instruments. Rear panel inputs/outputs. An XGA video output port allows you to connect to a large external monitor. Standard USB, LAN and GPIB ports provide PC and printer connectivity. Built-in 10-MHz reference in/out port lets you synchronize multiple measurement instruments in a system. Trig Out port provides an easy way to synchronize your scope to other instruments. Make time-correlated measurements between an Keysight logic analyzer and 6000 Series oscilloscope. 09 | Keysight | 6000 Series Oscilloscopes - Data Sheet Probes and accessories Keysight offers a complete family of innovative passive and active probes for the 6000 Series scopes to get your job done easily. For more comprehensive information, refer to the Keysight 6000 Series Oscilloscopes Probes and Accessories Data Sheet and Selection Guide (Keysight publication number 59688153EN/ ENUS and/or 59896162EN. Or for more information please visit our web site at www.keysight.com/find/scopes_probes. Selection guide 10070C 10074C (shipped with 100 MHz models) 10073C 10076A (shipped with high-voltage probe 300 MHz to 1 GHz models) N2771A high-voltage probe Probe bandwidth 20 MHz 150 MHz 500 MHz 250 MHz 50 MHz Probe rise time (calculated) < 17.5 ns < 2.33 ns < 700 ps < 1.4 ns < 7 ns Attenuation ratio 1:1 10:1 10:1 100:1 1000:1 Input resistance (when terminated into 1 M) 1 M 10 M 2.2 M 66.7 M 100 M Input capacitance Approx. 70 pF Approx. 15 pF Approx. 12 pF Approx. 3 pF Approx. 1 pF Maximum input (dc+peak ac) 400 Vpk CAT I (mains isolated) 400 Vpk CAT II (post receptacle mains) 500 Vpk CAT I (mains isolated) 400 Vpk CAT II (post receptacle mains) 500 Vpk CAT I (mains isolated) 400 Vpk CAT II (post receptacle mains) 4000 Vpk 15 kV dc, 10 kVrms, 30 kV dc + peak ac Compensation range None 9-17 pF 6-15 pF 6-20 pF 7-25 pF Probe sense No Yes Yes Yes No Note: These Infiniium active probes are not supported by 6000 Series 300 MHz to 1 GHz models - 1152A, 11 53A, 1 154A, 1 155A, 11 59A, 11 68A, and 11 69A. The 6000 Series 100 MHz models do not support any Keysight Infiniium active probes with AutoProbe interface. Accessories Options Description N2916A Rackmount Kit 1180CZ Testmobile scope cart N2917A Transit case N2919A Testmobile bracket for 1180CZ and 6000 10833A GPIB cable, 1 m long ABA Printed users guide in English ABJ Printed users guide in Japanese AB2 Printed users guide in simplified Chinese 10 | Keysight | 6000 Series Oscilloscopes - Data Sheet Software applications FPGA dynamic probe (N5406A for Xilinx, N5434A for Altera) Give your MSO internal FPGA visibility. Keysight's MSO FPGA dynamic probe provides internal FPGA visibility and quick instrument setup using an innovative core-assisted debug approach. Measurement tasks that previously took hours can be done in a few mouse clicks. In a few seconds, easily measure a different set of internal signals without changing your FPGA design. For more information: www.keysight.com/find/6000-altera www.keysight.com/find/6000-xilinx Debug and validate your FPGA designs faster and more effectively with FPGA dynamic probe and Keysight MSO. Vector signal analysis Expand the measurement capability of your 6000 Series scope with the 89601A vector signal analysis software. This advanced DSP based software takes the digitized signal data provided by the scope and provides FFT based spectrum analysis and wide bandwidth digital modulation analysis. Use these capabilities to demodulate wireless communication signals like WCDMA and cdma2000, and wireless networking signals like 802.11 WiFi and 802.16 WiMax. Take advantage of the super wide bandwidth of your scope to capture and evaluate radar signals. For more information: www.keysight.com/find/6000-vsa The E2690B oscilloscope tools make it easy for in-depth analysis of the captured signals. I2C/SPI serial trigger and decode (N5423A or Option LSS on new scope purchases) This application displays real-time timealigned decode of I2C and SPI serial buses. Hardware-assisted triggering and decode provide the industries fastest throughput and update rate. Hardware-assisted triggering and decode guarantees you will never miss an trigger event or anomaly - unlike other scopes that have triggering dead time between acquisitions. This application requires a 4-channel DSO or 4-channel MSO and can use any combination of the scope or logic acquisition channels. For more information: www.keysight.com/find/I2C-SPI On-screen serial decode of an I2C packet. 11 | Keysight | 6000 Series Oscilloscopes - Data Sheet Software applications (continued) CAN/LIN triggering and decode (N5424A or Option AMS on new scope purchases) Trigger on and decode serially transmitted data based on CAN and LIN protocols. This application not only provides triggering on complex serial signals, but also provides unique hardware-accelerated decode capabilities. Hardware-assisted triggering and decode guarantees you will never miss an trigger event or anomaly - unlike other scopes that have triggering dead time between acquisitions. This application requires a 4-channel DSO or 4-channel MSO and can use any combination of scope or logic acquisition channels. Random errors observed in CAN decode while triggering on data frame ID: 07FHEX. For more information: www.keysight.com/find/CAN-LIN FlexRay triggering and decode (N5432A or Option FRS on new scope purchases) FlexRay protocol is based on time-triggered and deterministic architecture. Keysight's FlexRay solution for the 6000 Series mixed signal oscilloscopes offers a robust set of FlexRay frame, slot, and error triggering, including the ability to trigger on specific FlexRay communications qualified on basecycle and cyclerepetition. This solution combines a Keysight 6000 Series mixed signal oscilloscope (MSO) with a DECOMSYS::BUSDOCTOR 2 protocol analyzer. For more information: www.keysight.com/find/flexray Mixed-signal measurements in a FlexRay system using an MSO. 12 | Keysight | 6000 Series Oscilloscopes - Data Sheet Keysight 6000 Series oscilloscopes: The right combination of features and performance to bring your toughest analog, digital and serial problems into focus. MegaZoom III deep memory helps you determine how your signals are impacting each other. With shallow memory scopes, you have to choose whether you look at a slow analog signal or fast digital content. With up to 8 Mpts deep memory, you don't have to choose - capture all of your data at once. Revolutionary high-resolution color display with XGA resolution and 256 levels of intensity reveals subtle details that most scopes won't show you. Built-in USB port makes it easy to save your work and update your system software quickly. Intensity knob allows you to see the right level of waveform detail, just like an analog scope. Free IntuiLink Data Capture PC software makes transferring waveform data or screen image to a PC fast and easy. 13 | Keysight | 6000 Series Oscilloscopes - Data Sheet Built-in storage compartment allows you to store probes and power cord for easy access and transportation. Quickly pan and zoom for analysis with MegaZoom III's instant response and optimum resolution. QuickMeas shows up to four automated measurements with the push of a button. QuickPrint automatically prints your screen or saves screen images to a connected USB storage device with automated file names. Standard serial triggering includes I2C, SPI, and USB (optional CAN/LIN and FlexRay advanced triggering and decode). Standard analog HDTV/EDTV triggering supports triggering on 1080i, 1080p, 720p, 480p HDTV/EDTV standards. AutoProbe interface automatically configures the attenuation ratio of the probe and provides probe power for Keysight's active probes (available on 300 MHz to 1 GHz models only). Built-in help in six languages. Simply press and hold the frontpanel key of interest for a few seconds, and a help screen pops up to explain its function. Autoscale lets you quickly display any active signals, automatically setting the vertical, horizontal and trigger controls for the best display, while optimizing memory. Maximum sample rate and resolution is achieved on every measurement. The scope automatically adjusts memory depth as you use it, so you get maximum sample rate and resolution on every measurement. You don't even have to think about it. 2 or 4 scope and 16 logic channel MSOs allow you to view and trigger on up to 20 time-aligned signals on your scope screen. Dedicated front-panel controls make it easy to access the most common scope controls, including vertical and horizontal scaling. 14 | Keysight | 6000 Series Oscilloscopes - Data Sheet Accessories Battery option (Option BAT - factory installed) Keysight 6000 Series oscilloscopes provide an optional internal rechargeable lithium ion battery that will enable 2+ hours without line power. Specifically designed for applications where line power is not available or where you need to take your scope with you but you need more power than a handheld scopemeter provides. New oscilloscopes equipped with this option can also be operated off of the N5429A 12-V automotive adapter. The Keysight 6000 Series oscilloscopes offer the only highperformance scope with battery option on the market. For more information: www.keysight.com/find/6000_BAT Evaluation kit (N2918A) The scope evaluation kit for 6000 Series MSOs provides signals to help you experience the power of Keysight 6000 Series MSOs. The kit includes a variety of signals that demonstrate MegaZoom III technology with its fast deep memory, superior waveform update rate, high definition display and mixed analog, digital and serial signals debugging. Using this scope evaluation kit along with the easy-to-follow user's guide, you can quickly become familiar with how to effectively use an MSO. Secure environment mode (Option SEC or N5427A) Option SEC - secure environment mode provides the highest level of security by ensuring internal non-volatile memory is clear of all setup and trace settings in compliance with National Industrial Security Program Operation Manual (NISPOM) Chapter 8 requirements. When this option is installed, it will store setup and trace settings to internal volatile memory only. Volatile memory will be cleared during the power off cycle of the instrument. So you can move the instrument out of a secure area with confidence. For more information: Option SEC or N5427A Secure Environment Mode Option for Keysight 6000 Series Oscilloscopes Data Sheet (Keysight publication number 59895558EN). The N2918A evaluation helps you experience the power of Keysight 6000 MSO. 15 | Keysight | 6000 Series Oscilloscopes - Data Sheet Performance characteristics Acquisition: scope channels Sample rate MSO/DSO601xA/603xA: 2 GSa/sec each channel MSO/DSO605xA/610xA: 4 GSa/sec half channel*, 2 GSa/sec each channel Equivalent-time sample rate: 400 GSa/s (when real-time mode is turned off) Standard 2 Mpts memory depth With logic channels turned off, 2 Mpts half channel*, 1 Mpts full channel With logic channels turned on, 1.25 Mpts half channel*, 625 kpts full channel Optional 8 Mpts memory depth With logic channels turned off, Option 8ML or 8MH - 8 Mpts half channel*, 4 Mpts each channel With logic channels turned on, Option 8ML or 8MH - 5 Mpts half channel*, 2.5 Mpts each channel Vertical resolution 8 bits Peak detection MSO/DSO601xA: 1-ns peak detect MSO/DSO603xA: 500-ps peak detect MSO/DSO605xA/610xA: 250-ps peak detect Averaging Selectable from 2, 4, 8, 16, 32, 64 ... to 65536 High resolution mode Average mode with avg = 1 12 bits of resolution when 10 s/div @ 4 GSa/s or 20s/div @ 2 GSa/s Filter Sinx/x interpolation (single shot BW = sample rate/4 or bandwidth of scope, whichever is less) with vectors on and in real-time mode Acquisition: logic channels (MSO6000A or MSO-upgraded DSO6000A only) Sample rate 2 GSa/sec one pod, 1 GSa/sec each pod Maximum input frequency 250 MHz Standard 2 Mpts memory depth With scope channels turned off, 2 Mpts one pod, 1 Mpts each pod With scope channels turned on, 625 kpts one pod, 312 kpts each pod Optional 8 Mpts memory depth With scope channels turned off, Option 8ML or 8MH - 8 Mpts one pod, 4 Mpts each pod With scope channels turned on, Option 8ML or 8MH - 2.5 Mpts one pod, 1.25 Mpts each pod Vertical resolution 1 bit Glitch detection 2 ns (min pulse width) *Half channel is when only one of channel 1 or 2 is turned on, and only channel 3 or 4 is turned on. 16 | Keysight | 6000 Series Oscilloscopes - Data Sheet Performance characteristics (continued) Vertical system: scope channels Scope channels MSO/DSO6xx2A: Ch 1 and 2 simultaneous acquisition MSO/DSO6xx4A: Ch 1, 2, 3 and 4 simultaneous acquisition Bandwidth (-3dB)* MSO/DSO601xA: DC to 100 MHz MSO/DSO603xA: DC to 300 MHz MSO/DSO605xA: DC to 500 MHz MSO/DSO610xA: DC to 1 GHz AC coupled MSO/DSO601xA: 3.5 Hz to 100 MHz MSO/DSO603xA: 3.5 Hz to 300 MHz MSO/DSO605xA: 3.5 Hz to 500 MHz MSO/DSO610xA: 3.5 Hz to 1 GHz Calculated rise time (=0.35/bandwidth) MSO/DSO601xA: 3.5 nsec MSO/DSO603xA: 1.17 nsec MSO/DSO605xA: 700 psec MSO/DSO610xA: 350 psec Single-shot bandwidth MSO/DSO601xA: 100 MHz MSO/DSO603xA: 300 MHz MSO/DSO605xA: 500 MHz MSO/DSO610xA: 1 GHz (in half-channel mode) Range1 MSO/DSO601xA: 1 mV/div to 5 V/div (1 M) MSO/DSO603xA and MSO/DSO605xA: 2 mV/div to 5 V/div (1 M or 50 ) MSO/DSO610xA: 2 mV/div to 5 V/div (1 M), 2 mV/div to 1 V/div (50 ) Maximum input CAT I 300 Vrms, 400 Vpk; transient overvoltage 1.6 kVpk CAT II 100 Vrms, 400 Vpk With 10073C or 10074C 10:1 probe: CAT I 500 Vpk, CAT II 400 Vpk Offset range 5 V on ranges <10 mV/div; 20 V on ranges 10 mV/div to 200 mV/div; 75 V on ranges >200 mV/div Dynamic range 8 div Input impedance MSO/DSO601xA: 1 M 1% || 11 pF MSO/DSO603xA/605xA/610xA: 1 M 1% || 14 pF or 50 1.5%, selectable Coupling AC, DC BW limit MSO/DSO601xA: 20 MHz selectable MSO/DSO603xA/605xA/610xA: 25 MHz selectable Channel-to-channel isolation DC to max bandwidth >40 dB Standard probes MSO/DSO601xA: 10:1 10074C shipped standard for each scope channel MSO/DSO603xA/605xA/610xA: 10:1 10073C shipped standard for each scope channel Probe ID MSO/DSO601xA: Auto probe sense MSO/DSO603xA/605xA/610xA: Auto probe sense and AutoProbe interface Keysight- and Tektronix-compatible passive probe sense * Denotes warranted specifications, all others are typical. Specifications are valid after a 30-minute warm-up period and 10 C from firmware calibration temperature. 1. Half channel is when only one of channel 1 or 2 is turned on, and only channel 3 or 4 is turned on. 17 | Keysight | 6000 Series Oscilloscopes - Data Sheet Performance characteristics (continued) Vertical system: scope channels (continued) ESD tolerance 2 kV Noise peak-to-peak MSO/DSO601xA: 3% full scale or 2 mV, whichever is greater MSO/DSO603xA: 3% full scale or 3 mV, whichever is greater MSO/DSO605xA: 3% full scale or 3.6 mV, whichever is greater MSO/DSO610xA: 3% full scale or 4 mV, whichever is greater DC vertical gain accuracy*1 2.0% full scale DC vertical offset accuracy 200 mV/div: 0.1 div 2.0 mV 0.5% offset value; >200 mV/div: 0.1 div 2.0 mV 1.5% offset value Single cursor accuracy1 {DC vertical gain accuracy + DC vertical offset accuracy + 0.2% full scale (~1/2 LSB)} Example: for 50 mV signal, scope set to 10 mV/div (80 mV full scale), 5 mV offset, accuracy = {2.0% (80 mV) + 0.1 (10 mV) + 2.0 mV + 0.5% (5 mV) + 0.2% (80 mV)} = 4.785 mV Dual cursor accuracy*1 {DC vertical gain accuracy + 0.4% full scale (~1 LSB)} Example: for 50 mV signal, scope set to 10 mV/div (80 mV full scale), 5 mV offset, accuracy = {2.0% (80 mV) + 0.4% (80 mV)} = 1.92 mV * Denotes warranted specifications, all others are typical. Specifications are valid after a 30-minute warm-up period and 10 C from firmware calibration temperature. 1. 1 mV/div is a magnification of 2 mV/div setting for 100 MHz models and 2 mV/div is a magnification of 4 mV/div setting for 300 MHz to 1 GHz models. For vertical accuracy calculations, use full scale of 16 mV for 1 mV/div sensitivity setting and 32 mV for 2 mV/div sensitivity setting. Vertical system: logic channels (MSO6000A or MSO-upgraded DSO6000A only) Number of channels 16 logic timing channels - labeled D15 - D0 Threshold groupings Pod 1: D7 - D0 Pod 2: D15 - D8 Threshold selections TTL, CMOS, ECL and user-definable (selectable by pod) User-defined threshold range 8.0 V in 10 mV increments Maximum input voltage 40 V peak CAT I; transient overvoltage 800 Vpk Threshold accuracy* (100 mV + 3% of threshold setting) Input dynamic range 10 V about threshold Minimum input voltage swing 500 mV peak-to-peak Input capacitance ~8 pF Input resistance 100 k 2% at probe tip Channel-to-channel skew 2 ns typical, 3 ns maximum * Denotes warranted specifications, all others are typical. Specifications are valid after a 30-minute warm-up period and 10 C from firmware calibration temperature. 18 | Keysight | 6000 Series Oscilloscopes - Data Sheet Performance characteristics (continued) Horizontal Range MSO/DSO601xA: 5 nsec/div to 50 sec/div MSO/DSO603xA: 2 nsec/div to 50 sec/div MSO/DSO605xA: 1 nsec/div to 50 sec/div MSO/DSO610xA: 500 psec/div to 50 sec/div Resolution 2.5 psec Time base accuracy 15 ppm (0.0015%) Vernier 1-2-5 increments when off, ~25 minor increments between major settings when on Delay range Pre-trigger (negative delay): Greater of 1 screen width or 1 ms (with 8 Mpts memory option) Greater of 1 screen width or 250 s (with 2 Mpts memory option) Greater of 1 screen width or 125 s (with standard memory) Post-trigger (positive delay): 1 s to 500 seconds Analog delta-t accuracy Same channel: 0.0015% reading 0.1% screen width 20 ps Channel-to-channel: 0.0015% reading 0.1% screen width 40 ps Same channel example (MSO/DSO605xA): For signal with pulse width of 10 s, scope set to 5 s/div (50 s screen width), delta-t accuracy = {0.0015% (10 s) + 0.1% (50 s) + 20 ps} = 50.17 ns Logic delta-t accuracy Same channel: 0.005% reading 0.1% screen width (1 logic sample period, 1 ns) Channel-to-channel: 0.005% reading 0.1% screen width (1 logic sample period) chan-to-chan skew Same channel example: For signal with pulse width of 10 s, scope set to 5 s/div (50 s screen width), delta-t accuracy = {0.005% (10 s) + 0.1% (50 s) + 1 ns} = 51.5 ns Modes Main, delayed, roll, XY XY Bandwidth: Max bandwidth Phase error @ 1 MHz: <0.5 degrees Z Blanking: 1.4 V blanks trace (use external trigger on MSO/DSO6xx2A, channel 4 on MSO/DSO6xx4A) Reference positions Left, center, right Trigger system Sources MSO6xx2A: Ch 1, 2, line, ext, D15 - D0 DSO6xx2A: Ch 1, 2, line, ext MSO6xx4A: Ch 1, 2, 3, 4, line, ext, D15 - D0 DSO6xx4A: Ch 1, 2, 3, 4, line, ext Modes Auto, Normal (triggered), single Holdoff time ~60 ns to 10 seconds Trigger jitter 15 ps rms 19 | Keysight | 6000 Series Oscilloscopes - Data Sheet Performance characteristics (continued) Trigger system (continued) Selections Edge, pulse width, pattern, TV, duration, sequence, CAN, LIN, FlexRay, USB, I2C, SPI, Nth edge burst Edge Trigger on a rising, falling, alternating or either edge of any source Pattern Trigger at the beginning of a pattern of high, low, and don't care levels and/or a rising or falling edge established across any of the analog and digital channels, but only after a pattern has stabilized for a minimum of 2 nsec. The scope channel's high or low level is defined by that channel's trigger level. The logic channel's trigger level is defined by the threshold for the pod, 0 - 7 or 8 - 15. Pulse width Trigger when a positive- or negative-going pulse is less than, greater than, or within a specified range on any of the source channels. Minimum pulse width setting: 5 ns (MSO/DSO601xA/603xA scope channels) 2 ns (MSO/DSO605xA/610xA scope channels) 2 ns (logic channels on MSO6000A or MSO-upgraded DSO6000A) Maximum pulse width setting: 10 s TV Trigger using any scope channel on most analog progressive and interlaced video standards including HDTV/EDTV, NTSC, PAL, PAL-M or SECAM broadcast standards. Select either positive or negative sync pulse polarity. Modes supported include Field 1, Field 2, all fields, all lines, or any line within a field. TV trigger sensitivity: 0.5 division of sync signal. Trigger holdoff time can be adjusted in half field increments. Sequence Arm on event A, trigger on event B, with option to reset on event C or time delay. CAN Trigger on CAN (Controller Area Network) version 2.0A and 2.0B signals. Trigger on the start of frame (SOF) bit (standard). N5424A option supports triggering on remote frame ID (RTR), data frame ID (~RTR), remote or data frame ID, data frame ID and data, error frame, all errors, acknowledge error and overload frame. LIN Trigger on LIN (Local Interconnect Network) sync break at beginning of message frame (standard). N5424A option supports triggering on frame ID. FlexRay N5432A option supports trigger on FlexRay frame ID or time slot or specific error condition, along with cycle-base and repetition-cycle filtering. USB Trigger on USB (Universal Serial Bus) start of packet, end of packet, reset complete, enter suspend, or exit suspend on the differential USB data lines. USB low speed and full speed are supported. C Trigger on I2C (Inter-IC bus) serial protocol at a start/stop condition or user defined frame with address and/or data values. Also trigger on missing acknowledge, address with no acq, restart, EEPROM read, and 10-bit write. I2 SPI Trigger on SPI (Serial Protocol Interface) data pattern during a specific framing period. Supports positive and negative Chip Select framing as well as clock Idle framing and user-specified number of bits per frame. Duration Trigger on a multi-channel pattern whose time duration is less than a value, greater than a value, greater than a time value with a timeout, or inside or outside of a set of time values. Minimum duration setting: 2 ns Maximum duration setting: 10 s Nth edge burst Trigger on the Nth edge of a burst that occurs after an idle time that you specify. Max edge count: 65,536. 20 | Keysight | 6000 Series Oscilloscopes - Data Sheet Performance characteristics (continued) Trigger system (continued) Autoscale Finds and displays all active scope and logic (for MSO6000A series MSO) channels, sets edge trigger mode on highest-numbered channel, sets vertical sensitivity on scope channels and thresholds on logic channels, time base to display ~1.8 periods. Requires minimum voltage >10 mVpp, 0.5% duty cycle and minimum frequency >50 Hz. Scope channel triggering Range (internal) 6 div from center screen Sensitivity* <10 mV/div: greater of 1 div or 5 mV; 10 mV/div: 0.6 div Coupling AC (~3.5 Hz on MSO/DSO601xA, ~10 Hz on MSO/DSO603xA/605xA/610xA), DC, noise reject, HF reject and LF reject (~50 kHz) Logic (D15 - D0) channel triggering (MSO6000A or MSO-upgraded DSO6000A only) Threshold range (user defined) 8.0 V in 10 mV increments Threshold accuracy* (100 mV + 3% of threshold setting) Predefined thresholds TTL = 1.4 V, CMOS = 2.5 V, ECL = -1.3 V External (EXT) triggering MSO/DSO6xx2A (2-/2+16-ch models) MSO/DSO6xx4A (4-/4+16-ch models) Input impedance MSO/DSO6012A: 1 M 3% || 11 pF or 50 MSO/DSO6032A/6052A/6102A: 1 M 3% || 14 pF or 50 MSO/DSO6014A: 1.015 k 5% MSO/DSO6034A/6054A/6104A: 2.14 k 5% Maximum input CAT I 300 Vrms, 400 Vpk, CAT II 100 Vrms, 400 Vpk With 10073C 10:1 probe: CAT I 500 Vpk, CAT II 400 Vpk 5 Vrms with 50- input 15 V Range DC coupling: trigger level 1 V and 8 V 5 V Sensitivity For 1 V range setting: DC to 100 MHz, 100 mV; MSO/DSO6032A/6052A/6102A: >100 MHz to bandwidth of oscilloscope: 200 mV For 8 V range setting: DC to 100 MHz, 250 mV; MSO/DSO6032A/6052A/6102A: >100 MHz to bandwidth of oscilloscope: 500 mV MSO/DSO6014A: DC to 100 MHz: 500 mV MSO/DSO6034A/6054A/6104A: DC to 500 MHz: 500 mV Coupling AC (~3.5 Hz), DC, noise reject, HF reject and LF reject (~50 kHz) Probe ID MSO/DSO601xA: Auto probe sense MSO/DSO603xA/605xA/610xA: Auto probe sense and AutoProbe interface Keysight- and Tektronix-compatible passive probe sense * Denotes warranted specifications, all others are typical. Specifications are valid after a 30-minute warm-up period and 10 C from firmware calibration temperature. 21 | Keysight | 6000 Series Oscilloscopes - Data Sheet Performance characteristics (continued) Display system Display 6.3-inch (161 mm) diagonal color TFT LCD Throughput of scope channels Up to 100,000 waveforms/sec in real-time mode Resolution XGA - 768 vertical by 1024 horizontal points (screen area); 640 vertical by 1000 horizontal points (waveform area) 256 levels of intensity scale Controls Waveform intensity on front panel. Vectors on/off; infinite persistence on/off, 8 x 10 grid with intensity control Built-in help system Key-specific help (in English) displayed by pressing and holding key or softkey of interest Real-time clock Time and date (user adjustable) Measurement features Automatic measurements Measurements are continuously updated. Cursors track last selected measurement. Up to four measurements can be displayed on screen at any one time. Voltage (scope channels only) Peak-to-peak, maximum, minimum, average, amplitude, top, base, overshoot, preshoot, RMS, standard deviation (AC RMS) Time Peak-to-peak, maximum, minimum, average, amplitude, top, base, overshoot, preshoot, RMS, standard deviation (AC RMS) Counter Built-in 5-digit frequency counter on any channel. Counts up to the scope's bandwidth (1 GHz max). The counter resolution can be increased to 8 digits with an external 10MHz reference. Threshold definition Variable by percent and absolute value; 10%, 50%, 90% default for time measurements Cursors Manually or automatically placed readout of Horizontal (X, X, 1/X) and Vertical (Y, Y). Additionally logic or scope channels can be displayed as binary or hex values. Waveform math One function of 1-2, 1x2, FFT, differentiate, integrate. Source of FFT, differentiate, integrate: scope channels 1 or 2, 1-2, 1+2, 1x2. FFT Points Fixed at 1000 points Source of FFT Scope channels 1 or 2 (or 3 or 4 on MSO/DSO6xx4A only), 1+2, 1-2, 1*2 Window Rectangular, flattop, hanning Noise floor -50 to -90 dB depending on averaging Amplitude Display in dBV, dBm at 50 Frequency resolution 0.05/time per div Maximum frequency 50/time per div 22 | Keysight | 6000 Series Oscilloscopes - Data Sheet Performance characteristics (continued) Storage Save/recall (non-volatile) 10 setups and traces can be saved and recalled internally. Optional secure environment mode ensures setups and traces are stored to internal volatile memory so data is erased when power is removed. Compliant to NISPOM Chapter 8 requirements. Storage type and format USB 1.1 host ports on front and rear panels Image formats: BMP (8-bit), BMP (24-bit), PNG (24-bit) Data formats: X and Y (time/voltage) values in CSV format, ASCII XY and binary format Trace/setup formats: Recalled I/O Standard ports USB 2.0 high speed device, two USB 1.1 host ports, 10/100-BaseT LAN, IEEE488.2 GPIB, XGA video output Max transfer rate IEEE488.2 GPIB: 500 kbytes/sec USB (USBTMC-USB488): 3.5 Mbytes/sec 100 Mbps LAN (TCP/IP): 1 Mbytes/sec General characteristics Physical size 35.4 cm wide x 18.8 cm high x 28.2 cm deep (without handle) 39.9 cm wide x 18.8 cm high x 28.2 cm deep (with handle) Weight Net: 4.9 kgs (10.8 lbs) Shipping: 9.4 kgs (20.7 lbs) Probe comp output Frequency ~2 kHz; Amplitude ~5 V Trigger out When Triggers is selected (delay ~17 ns) 0 to 5 V into high impedance 0 to 2.5 V into 50 When Source Frequency or Source Frequency/8* is selected 0 to 580 mV into high impedance 0 to 290 mV into 50 Max frequency output: 350 MHz (in source frequency mode when terminated in 50 ) 125 MHz (in source frequency/8 mode when terminated in 50 ) 10 MHz ref in/out TTL out, 180 mV to 1 V amplitude with 0 to 2 V offset Kensington lock Connection on rear panel for security * Source Frequency/8 is supported on 300 MHz to 1 GHz 6000 Series only. 23 | Keysight | 6000 Series Oscilloscopes - Data Sheet Performance characteristics (continued) Power requirements Line voltage range ~Line 120 W max, 96-144 V/48-440 Hz, 192-288 V/48-66 Hz, automatic selection Line frequency 50/60 Hz, 100-240 VAC; 440 Hz, 100-132 VAC Power usage 110 W max Battery option - BAT 2+ hours between charges, battery-low indicator at 20% Battery capacity after repeated charging: 80% after 300 cycles Environmental characteristics Ambient temperature Operating -10 C to +55 C; non-operating -51 C to +71 C Humidity Operating 95% RH at 40 C for 24 hr; non-operating 90% RH at 65 C for 24 hr Altitude Operating to 4,570 m (15,000 ft); non-operating to 15,244 m (50,000 ft) Vibration Keysight class B1 and MIL-PRF-28800F; class 3 random Shock Keysight class B1 and MIL-PRF-28800F; class 3 random; (operating 30g, 1/2 sine, 11 ms duration, 3 shocks/axis along major axis, total of 18 shocks) Pollution degree2 Normally only dry non-conductive pollution occurs. Occasionally a temporary conductivity caused by condensation must be expected. Indoor use Rated for indoor use only Other Measurement categories CAT I: Mains isolated CAT II: Line voltage in appliance and to wall outlet Regulatory information Safety IEC 61010-1:2001 / EN 61010-1:2001 Canada: CSA C22.2 No. 1010.1:1992 UL 61010B-1:2003 Supplementary information The product herewith complies with the requirements of the Low Voltage Directive 73/23/EEC and the EMC Directive 89/336/EEC, and carries the CE-marking accordingly. The product was tested in a typical configuration with HP/Keysight test systems. 24 | Keysight | 6000 Series Oscilloscopes - Data Sheet Ordering information Model Bandwidth Maximum sample rate Memory depth Scope channels DSO6012A 100 MHz 2 GSa/s 2 Mpts, 8 Mpts optional 2 MSO6012A 100 MHz 2 GSa/s 2 Mpts, 8 Mpts optional 2 DSO6014A 100 MHz 2 GSa/s 2 Mpts, 8 Mpts optional 4 MSO6014A 100 MHz 2 GSa/s 2 Mpts, 8 Mpts optional 4 DSO6032A 300 MHz 2 GSa/s 2 Mpts, 8 Mpts optional 2 MSO6032A 300 MHz 2 GSa/s 2 Mpts, 8 Mpts optional 2 DSO6034A 300 MHz 2 GSa/s 2 Mpts, 8 Mpts optional 4 MSO6034A 300 MHz 2 GSa/s 2 Mpts, 8 Mpts optional 4 DSO6052A 500 MHz 4 GSa/s 2 Mpts, 8 Mpts optional 2 MSO6052A 500 MHz 4 GSa/s 2 Mpts, 8 Mpts optional 2 DSO6054A 500 MHz 4 GSa/s 2 Mpts, 8 Mpts optional 4 MSO6054A 500 MHz 4 GSa/s 2 Mpts, 8 Mpts optional 4 DSO6102A 1 GHz 4 GSa/s 2 Mpts, 8 Mpts optional 2 MSO6102A 1 GHz 4 GSa/s 2 Mpts, 8 Mpts optional 2 DSO6104A 1 GHz 4 GSa/s 2 Mpts, 8 Mpts optional 4 MSO6104A 1 GHz 4 GSa/s 2 Mpts, 8 Mpts optional 4 Logic channels 16 16 16 16 16 16 16 16 Accessories included: Model number User's guide (localized), Service guide, Programmer's guide Power cord 10073C 10:1 divider passive probe with readout per scope channel Front panel cover Accessories storage Keysight I/O libraries suite 14.2 16 channel flying lead set logic probe (two pods with eight channels each) Standard 1-year warranty Note: IntuiLink Data Capture software available free on web at www.keysight.com/find/intuilink DSO600xA MSO600xA 25 | Keysight | 6000 Series Oscilloscopes - Data Sheet Ordering information Product upgrades DSO601xA MSO601xA DSO603xA MSO603xA DSO605xA MSO605xA DSO610xA MSO610xA Option 8MH Option 8MH N2913A N2913A N2915A* N2915A* 8 Mpts memory upgrade (Factory installed at time of initial scope purchase) Option 8ML 8 Mpts memory upgrade (User installed, typically ordered after initial scope purchase) N2911A DSO to MSO upgrade kit (User installed, typically ordered after initial scope purchase) N2914A* Rechargeable battery option (Factory installed at time of initial scope purchase) Option BAT Option Bat Option BAT Secure environment mode option (Factory installed at time of initial scope purchase) Option SEC Option SEC Option SEC Secure environment option (User installed, can be installed by Keysight service center for an additional charge) N5427A N5427A N5427A * Includes a 54620-68701 logic cable kit, a label and an upgrade license to activate the MSO features Digital analysis applications Option number - user installed Option number - factory installed Description N5406A FPGA dynamic probe for Xilinx (MSO models only) N5434A FPGA dynamic probe for Altera (MSO models only) Serial data analysis applications Option number - user installed Option number - factory installed Description N5424A AMS CAN/LIN automotive triggering and decode (4 and 4+16 channel models only) N5423A LSS I2C/SPI serial decode option (for 4/4+16 channel models only) N5432A FRS FlexRay automotive triggering and decode (4 and 4+16 channel models only) 26 | Keysight | 6000 Series Oscilloscopes - Data Sheet Related Literature Publication Title Publication Type Publication Number Keysight Technologies Probes and Accessories Selection Guide 5989-6162EN Keysight Technologies 6000 Series Oscilloscope Probes and Accessories Data Sheet 5968-8153EN/EUS Serial Bus Triggering and Hardware-Accelerated Decode Options for Keysight 6000 Series Oscilloscopes Data Sheet 5989-5126EN N5434A FPGA Dynamic Probe for Altera with 6000 Series MSOs Data Sheet 5989-5965EN N5406A FPGA Dynamic Probe for Xilinx with 6000 Series MSOs Data Sheet 5989-1848EN Improve Your Ability to Capture Elusive Events: Why Oscilloscope Waveform Update Rates are Important Application Note 1551 5989-2002EN Debugging Embedded Mixed-Signal Designs Using Mixed Signal Oscilloscopes Application Note 1562 5989-3702EN Oscilloscope Display Quality Impacts Ability to Uncover Signal Anomalies Application Note 1552 5989-2003EN Application Note 1553 5989-2004EN Deep Memory Oscilloscopes: The New Tools of Choice Application Note 1446 5988-9106EN Evaluating Oscilloscope Vertical Noise Characteristics Application Note 1558 5989-3020EN Using a Keysight 6000 Series MSO to Debug an Automotive CAN Bus Application Note 1576 5989-5049EN Ten Things to Consider When Selecting Your Next Oscilloscope Application Note 1490 5989-0552EN Keysight Technologies 6000 Series Brochure 5989-5806EN 27 | Keysight | 6000 Series Oscilloscopes - Data Sheet myKeysight www.keysight.com/find/mykeysight A personalized view into the information most relevant to you. www.lxistandard.org LAN eXtensions for Instruments puts the power of Ethernet and the Web inside your test systems. Keysight is a founding member of the LXI consortium. Three-Year Warranty www.keysight.com/find/ThreeYearWarranty Keysight's commitment to superior product quality and lower total cost of ownership. The only test and measurement company with three-year warranty standard on all instruments, worldwide. Keysight Assurance Plans www.keysight.com/find/AssurancePlans Up to five years of protection and no budgetary surprises to ensure your instruments are operating to specification so you can rely on accurate measurements. www.keysight.com/go/quality Keysight Technologies, Inc. DEKRA Certified ISO 9001:2008 Quality Management System Keysight Channel Partners www.keysight.com/find/channelpartners Get the best of both worlds: Keysight's measurement expertise and product breadth, combined with channel partner convenience. For more information on Keysight Technologies' products, applications or services, please contact your local Keysight office. The complete list is available at: www.keysight.com/find/contactus Americas Canada Brazil Mexico United States (877) 894 4414 55 11 3351 7010 001 800 254 2440 (800) 829 4444 Asia Pacific Australia China Hong Kong India Japan Korea Malaysia Singapore Taiwan Other AP Countries 1 800 629 485 800 810 0189 800 938 693 1 800 112 929 0120 (421) 345 080 769 0800 1 800 888 848 1 800 375 8100 0800 047 866 (65) 6375 8100 Europe & Middle East Austria Belgium Finland France Germany Ireland Israel Italy Luxembourg Netherlands Russia Spain Sweden Switzerland United Kingdom 0800 001122 0800 58580 0800 523252 0805 980333 0800 6270999 1800 832700 1 809 343051 800 599100 +32 800 58580 0800 0233200 8800 5009286 800 000154 0200 882255 0800 805353 Opt. 1 (DE) Opt. 2 (FR) Opt. 3 (IT) 0800 0260637 For other unlisted countries: www.keysight.com/find/contactus (BP-09-04-14) This information is subject to change without notice. (c) Keysight Technologies, 2007 - 2015 Published in USA, April 8, 2015 5989-2000EN www.keysight.com