MIT400 Series CAT IV Insulation Resistance and Continuity Testers MIT400 Series CAT IV Insulation Resistance and Continuity Testers n Insulation testing up to 1000 V and 200 G n Patented analog arc and dual digital display n CAT IV 600 V rating n TRMS & DC Voltage measurement n Continuity testing at 200 mA or 20 mA down to 0.01 n Pass/Fail limit alarms n PI/DAR and Timer function n n n n Test result storage (MIT Models 420, 430, 481 and 485) Bluetooth(R) wireless data transfer (MIT Models 430 and 485) Measurement of capacitance and distance by capacitance (MIT Models 481 and 485) User selectable test voltage in 1V increments from 10V to 100V (MIT Model 40X) n Three year product warranty n IP54 rated DESCRIPTION The Megger MIT400 Series insulation and continuity testers has been designed for electrical testing by power utilities, industrials, telecommunication companies, commercial/ domestic electricians and anyone with unique test voltage requirements. The wide range of features also makes the MIT400 Series ideal for maintenance technicians and engineers. They replace the well-established BM400 insulation tester range, giving greater functionality with simplified operation, greater application range and increased safety. The range The range consists of eight instruments: MIT400 250 V, 500 V and 1000 V MIT410 50 V, 100 V, 250 V, 500 V and 1000 V plus PI and DAR MIT420 Same as Model 410 plus result storage MIT430 Same as Model 420 plus Bluetooth(R) download MIT480 50 V, 100 V MIT481 50 V, 100 V, 250 V, 500 V, 1000 V plus PI, DAR and result storage MIT485 Same as Model 481, plus Bluetooth(R) download MIT40X 10 V to 100 V in 1 V steps Panelboard testing is faster, easier and safer with the new MIT400 Series. APPLICATIONS MIT Models 400, 410, 420 and 430 Industrial and Power Electrical Installation Testing: These models include all the features required for electricians, technicians and engineers working in a range of industries. Available features are selected to make testing easy and fast in a range of situations. Typical applications include: n Building/Campus electrical maintenance n Large and small scale electrical installations n Periodic electrical systems inspection and testing n Cable testing MIT400 Series CAT IV Insulation Resistance and Continuity Testers Service, Repair and Maintenance: The MIT Models 410, 420 and 430 add additional features required for technicians and engineers working on more demanding applications. Functions such as PI and DAR, capacitance measurement and a higher insulation range increase the suitability for applications such as: n Plant maintenance and production testing n Panelboard testing n Railway and other transportation maintenance and testing n Motor testing n Cable inspection/quality control n Street lighting maintenance n Avionics ground testing and maintenance n Military hardware and facility maintenance MIT Models 480, 481 and 485 Telecommunication Testing Designed to cope with the additional requirements of the telecommunications industry, MIT Models 480, 481 and 485 include 50 V and 100 V range insulation testing as standard, plus higher voltages as required. In addition, the voltage detection test inhibit feature has been raised to 75 V (from 50 V), to allow testing of cables with coactivity coupled induced voltages, which would normally inhibit such testing with a 50 V protected instrument. Finally the MIT481 and MIT485 models include measurement of cable distance by capacitance, providing a convenient cable length without the need to use TDR technology, with adjustable cable capacitance from 40 nF/Km to 60 nF/Km (default is 50 nF/Km). MIT Model 40X MIT40X shown measuring electrostatic charge in a computer control room. FEATURES AND BENEFITS n CAT IV 600 V rating - provides greater safety when testing at higher voltage levels n Adjustable insulation test voltages - provides 250 V to 1000 V or 50 V to 1000 V. The special applications instrument (Model MIT40X) offers test voltages from 10 V to 100 V in 1 V steps. n Dual digital display readout - allows display of complimentary test information simultaneously (for example: M plus test voltage or M plus leakage current) n Digital and analog arc display - includes not only the digital readout but also Megger's patented analog arc to replicate the response of a moving coil display n Exceptional measurement range from 20 G to 200 G - highest insulation test range available on the market, providing a superior range of measurement applications. n Choice of 20 mA or 200 mA continuity testing - allows user to select lower continuity range thus increasing battery life considerably n Continuity auto-test capability - enables real two-handed operation without the need to press the test button n Adjustable continuity limit alarm - allows pass/fail limits to be sent to speed testing n Automatically perform PI and DAR tests - user is able to quickly perform two important diagnostic tests. . . Polarization Index (PI) and Dielectric Absorption Ratio (DAR) n True RMS voltage measurement - allows accurate voltage measurement on noisy lines n Auto ranging voltage measurement - automatically adjusts range from millivolts to 600 V AC or DC, eliminating the need to keep changing ranging n Live circuit warning - automatically warns of contact to a live circuit, voltage is displayed and testing is inhibited n Auto fuse warning - warns of fuse failure automatically. No need to test the fuse manually. n Buzzer select button - enable or disable buzzer as required with resistance also displayed on the screen Special Applications Testing The MIT40X provides a new solution for unique insulation voltage measurement requirements. The MIT40X has a variable insulation test voltage from 10 V to 100 V in 1 V steps, selectable in the "Set-Up" menu. Typical applications include: n Commercial avionics testing n Military land, marine and air communications testing n Manufacturing/production line testing n Electrostatic test and measurement n Component testing n Battery powered traction and lifting equipment testing MIT400 Series CAT IV Insulation Resistance and Continuity Testers Instrument Comparison Chart Industrial and Power Applications Insulation Voltage range 400 410 420 Telcommunications Applications 430 480 481 485 10-100 V variable (2 G - 20 G) 50 V n n n n 100 V n n n n n n n n n n n n n 500 V n n n n n n 1000 V n n n n n n Insulation range 40X n n 250 V Special Application 20 G 100 G 200 G 200 G 100 G 200 G 200 G 2-20 G Leakage current display n n n n n n INS test voltage display n n n n n n n n 0.01 to 100 n n n n n n n n Variable current limit. 200 mA/20 mA n n n n n n n n Fast buzzer- selectable threshold n n n n n n n n k range to 999 k n n n n n n n n n n Continuity measurement Other functions and features Live circuit warning at 50 V Live circuit warning at 75 V n n n n Default voltmeter n n n n n n n TRMS measurement to 600 V n n n n n n n n Frequency Hz - 40 to 400 Hz n n n n n n Capacitance (0.1 nf to 10 F) n n n n mV/transducer (0.1 to 19.99 V) n n n n n n n n Backlight n n n n n n n n Battery condition display n n n n n n n n Insulation Timed - PI - DAR Tests n n n n n Test button plus lock button n n n n n n Limit alarm pass band on INS n n n Auto power down n n n n n n Result storage n n n n n n n n n n Other functions and features Bluetooth downloading Included accessories Red/black silicone lead set with clips n n n n n n n n Protective rubber boot with built-in stand n n n n n n n n Remote switch probe n n n n n n Calibration certificate with product n n n n n n n Batteries n n n n n n n n 3 Year warranty n n n n n n n n MIT400 Series CAT IV Insulation Resistance and Continuity Testers n MIT Models 480, 481 and 485 for telecommunication testing applications also include: n 75 V live circuit inhibit n Cable length by capacitance measurement (Model 481 & 485) n Cable distance in feet or km (Model 481 & 485) n Extensive results storage capability - store test date for later recall (Models MIT420, 430, 481 and 485) n Bluetooth download capability - wireless transfer of stored results to a PC (Models MIT430 and 485) n Stylish tapered design and center button placement - easy to use with either hand n Each instrument comes complete with: n New flexible, long-lasting silicone leads n Rugged instrument rubber boot n Calibration certificate n High-impact polypropylene carry case n Three year product warranty Instrument Safety The MIT400 Series instruments are designed to meet all of the requirements of IEC1010-2 and EN61557 and meets the safety requirements for use on CAT IV 600 V. Specific safety features include: SPECIFICATIONS All quoted accuracies are at +20 C. Insulation Nominal test voltages MIT400 250 V, 500 V, 1000 V MIT410, 420, 430 50 V, 100 V, 250 V, 500 V, 1000 V MIT480 50 V, 100 V MIT481, 485 50 V, 100 V, 250 V, 500 V, 1000 V MIT40X 10 V to 100 V variable (1 V increments) Insulation resistance range MIT400 20 G MIT410 100 G MIT420, 430 200 G MIT480 100 G MIT481, 485 200 G MIT40X 20 G Range Full Scale Accuracy 1000 volts 3% 2 digits 0.2% per G 500 volts 3% 2 digits 0.4% per G 250 volts 3% 2 digits 0.8% per G 100 volts 3% 2 digits 2.0% per G 50 volts 3% 2 digits 4.0% per G 10 volts 3% 2 digits 2.0% per 100 M Analog range: 1 G full scale Short Circuit Current: Terminal voltage: 2 mA +0% -50% -0% +20% 1 V n Any live circuit detection inhibits any insulation testing on circuits above 50 V (75 volts on Telecom models) n Any live circuit detection and test inhibit on continuity measurements Test Current on load: 1 mA at min. pass value of insulation specified in BS7671, HD384 and IEC364, 2 mA max. n Default display of live circuit voltage on all ranges EN61557 Operating range: 0.10 M to 1.00 G n Detection and inhibit features function even if the protections fuse has failed Leakage Current: 10% 3 digits Voltage display: 3% 3 digits 0.5% of rated voltage Polarization Index (PI): 10 min/1 minute ratio Also, fast detection circuitry prevents damage to the instruments if accidentally connected to live circuits or across phases. Included with every instrument Each MIT400 Series instrument comes complete with the following: n n Set of silicone test leads - Flexible and long lasting, these leads prevent errors from test lead leakage on high resistance type of insulation testing. They also provide increased accuracy above 10 G. Rugged instrument rubber boot with built-in stand- Protects the instrument from dings and drops and provides an easier, better grip of the instrument. n Plug-in switch probe - Allows the user to remotely perform insulation tests, reducing the time taken to perform a test. Not included with the MIT400 and 40X. n High-impact polypropylene carry case - Further protects the instrument and provides space for the leads, switch probe, etc. n Free calibration certificate (not included with the MIT40X). n Owner information CD. n Three year product warranty. Dielectric Absorption Ratio (DAR): 60 sec/30 sec ratio Notes: (1) All ranges measure from 0.00 M upwards. (2) Above specifications only apply when high quality silicone leads are being used. Continuity Measurement: Accuracy: Open circuit voltage: 0.01 to 99.9 (0 to 100 on analog scale) 3% 2 digits (0 to 100 ) 5 V 1 V Test current: 200 mA (-0 mA +20 mA) (0.01 to 9.99 ) 20mA (1 mA ) (10.0 to 99.9 ) MIT400 Series CAT IV Insulation Resistance and Continuity Testers Zero offset at probe tips: Lead resistance zeroing: Buzzer: Resistance Measurement: Accuracy: Open circuit voltage: Short circuit current: 0.10 typical Up to 9.00 Variable limit 1, 2, 5, 10, 20 Power Supply: 5 x 1.5 V cells type IEC LR6 (AA, MN1500, HP7, AM3 R6HP) Alkaline NiMH rechargeable cells may be used. Battery life: 2200 insulation tests with duty cycle of 5 sec ON /55 sec OFF @ 1000 V into 1 M 0.01 k to 1000 k (0 to 1 M on analog scale) 3% 2 digits 5 V 1 V 20 A 5 A Voltage range 0 to 600 V d.c. 2% 2 digits 10 mV to 600 V TRMS sinusoidal (40 to 400 Hz) 2% 2 digits 0 to 1000 V on Analog scale Unspecified input level 0 - 10 mV (40 to 400 Hz) Dimensions Instrument: 220 x 92 x 50 mm (8.66 in. x 3.63 in. x 1.97 in.) Instrument and case: 456 x 178 x 89 mm (18 in. x 7 in. x 3.5 in.) Weight Instrument only: 590 gms (20.73 oz.), 775 gms (27.22 oz.) with boot Instrument and case: 1.75kg (3.86 lb) Fuse Use only a 500 mA (FF) 1000 V 32 x 6 mm ceramic fuse of high breaking capacity HBC 50 kA minimum. Glass fuses MUST NOT be fitted. For non-sinusoidal waveforms additional specification apply: 3% 2 digits 101 mV to 600 V TRMS and 8% 2 digits 10 mV to 100 mV TRMS Safety Protection The instruments meet EN 61010-1 (1995) to 600 V phase to earth, Category IV. Refer to safety warnings supplied. Default Voltmeter: Operates at >25 V a.c. or d.c. on any range except OFF E.M.C. In accordance with IEC 61326 including amendment No.1 Frequency: 40 - 450 Hz (40 Hz - 99.9 Hz) 0.5% 1 digit (100 Hz to 450 Hz) Capacitance measurement MIT420, MIT430, MIT481 and MIT485 Measurement range: Accuracy: 100 pF to 10 F 5.0% 2 digits Distance by capacitance: MIT481 and MIT485 Arithmetic conversion from capacitance measurement on Default capacitance measurement: 50 nF/m Capacitance range: 40 nF/m to 60 nF/m Result storage Capacity: Download: Bluetooth Class: Range: >1000 test results Bluetooth wireless Class II up to 10 m Temperature effects Temperature coefficient: <0.1% per C up to 1 G Environmental Operating range: -10 to +55 C Operating humidity: 90% RH at 40 C max. Storage temperature range: -25 to +70 C Calibration Temperature: +20 C Maximum altitude: 2000 m Dust and water protection: IP54 Protected against dust and splashing water The Bluetooth word mark and logo are owned by the Bluetooth SIG, Inc. and any use of such marks by Megger is under license. MIT400 Series CAT IV Insulation Resistance and Continuity Testers Instrument Dual Digital Display Example The MIT400 Series offers an impressive dual digital display readout. It allows complimentary information to be displayed simultaneously such as: n M plus test voltage n M plus leakage current n Capacitance plus cable length (a test measurement for telecom applications) The second digital display simultaneously displays the following information, depending upon the mode of operation or function chosen: n Insulation voltage being delivered n INS test modes n Leakage current n Test current n Timer modes n Countdown times n Cable length The following display example shows the key elements of the first digital display: Patented Analog Arc Battery Monitor Single Point "Pointer" Second Digital Display Autoranging Main Digital Diplay Test in Progress Warning Test Lock Warning Test Result Range Indicator ORDERING INFORMATION Item (Qty) Model MIT400 Order No. MIT400EN 250 V, 500 V and 1000 V Insulation & Continuity Tester Model MIT410 50 V, 100 V, 250 V, 500 V and 1000 V Insulation and Continuity Tester with PI, DAR and switch probe Model MIT420 Same as Model MIT410 PLUS capacitance and data storage MIT420EN Model MIT430 Same as Model MIT420 PLUS wireless Bluetooth(R) download MIT430EN Model MIT40X 10 V to 100 V (in 1 V steps) Insulation and Continuity Tester MIT40XEN Model MIT480 50 V and 100 V Insulation and Continuity Tester MIT480EN Model MIT481 50 V, 100 V, 250 V, 500 V and 1000 V Insulation and Continuity Tester with capacitance, cable length measurement, data storage/download and switch probe MIT481EN Model MIT485 Same as Model MIT481 PLUS wireless Bluetooth(R) download MIT485EN MIT410EN Included Accessories Red/Black silicone test lead set with crocodile clips Hard carry case Instrument rubber boot with built-in stand Calibration certificate (not included with Model MIT40X) SP5 remote switch probe (not included with MIT400 and MIT40X) Owner information CD Optional Accessories Replacement lead set 6220-813 SP5 remote switch probe 6220-812 Instrument rubber boot with built-in stand 6231-802 Hard carry case 5410-420 Test and carry pouch 6220-860 UK Archcliffe Road, Dover CT17 9EN England T +44 (0) 1 304 502101 F +44 (0) 1 304 207342 UKsales@megger.com UNITED STATES 4271 Bronze Way Dallas, TX 75237-1019 USA T 1 800 723 2861 (USA only) T +1 214 333 3201 F +1 214 331 7399 USsales@megger.com OTHER TECHNICAL SALES OFFICES Valley Forge USA, College Station USA, Sydney AUSTRALIA, Taby SWEDEN, Ontario CANADA, Trappes FRANCE, Oberursel GERMANY, Aargau SWITZERLAND, Kingdom of BAHRAIN, Mumbai INDIA, Johannesburg SOUTH AFRICA, and Chonburi THAILAND Registered to ISO 9001:2000 Cert. no. Q 09290 Registered to ISO 14001-1996 Cert. no. EMS 61597 MIT400Combo_DS_US_en_V04 www.megger.com Megger is a registered trademark