SOT23 Dual-Input USB/AC Adapter 1-Cell Li+
Battery Chargers
ABSOLUTE MAXIMUM RATINGS
ELECTRICAL CHARACTERISTICS
(VDC = 5V, VUSB = 0, IBAT = 0, CBAT = 1µF, TA = 0°C to +85°C, unless otherwise noted.)
Stresses beyond those listed under “Absolute Maximum Ratings” may cause permanent damage to the device. These are stress ratings only, and functional
operation of the device at these or any other conditions beyond those indicated in the operational sections of the specifications is not implied. Exposure to
absolute maximum rating conditions for extended periods may affect device reliability.
DC to GND......................................................................0 to +8V
DC to BAT .......................................................................0 to +7V
BAT, CHG, POK, USB to GND .................................-0.3V to +7V
Continuous Power Dissipation (TA = +70°C)
5-Pin Thin SOT23 (derate 9.1mW/°C above +70°C)....727mW
Operating Temperature Range ...........................-40°C to +85°C
Junction Temperature Range ............................-40°C to +150°C
Storage Temperature Range .............................-65°C to +150°C
Lead Temperature (soldering, 10s) .................................+300°C
PARAMETER CONDITIONS MIN TYP MAX UNITS
DC
DC Voltage Range (Note 1) 3.7 7.0 V
DC to BAT Voltage Range 0.1 6.0 V
DC Undervoltage Lockout
Threshold Input rising, 430mV hysteresis, VBAT = 3V (Note 1) 3.75 3.95 4.15 V
DC Supply Current 1.75 3 mA
DC to BAT On-Resistance VDC = 3.7V, VBAT = 3.6V 1 2 Ω
DC to BAT Dropout Voltage When charging stops, VBAT = 4V,
DC falling, 200mV hysteresis 30 60 90 mV
USB
USB Voltage Range (Note 1) 3.7 6.0 V
USB Undervoltage Threshold Input rising, 430mV hysteresis, VDC = 0,
VBAT = 3V (Note 1) 3.75 3.95 4.15 V
USB Supply Current VUSB = 5V, VDC = 0 1.65 3 mA
USB to BAT On-Resistance VUSB = 3.7V, VBAT = 3.6V, VDC = 0 2 4 Ω
USB to BAT Dropout Voltage When charging stops, VBAT = 4V,
USB falling, 200mV hysteresis, VDC = 0 30 60 90 mV
BAT
BAT Regulation Voltage VDC or VUSB = 5V 4.158 4.2 4.242 V
DC Charging Current VBAT = 3.3V, VUSB = 0, VDC = 5V 220 280 340 mA
USB Charging Current VBAT = 3.3V, VDC = 0, VUSB = 5V 80 90 100 mA
BAT Prequal Threshold VBAT rising, 100mV hysteresis 2.9 3 3.1 V
Prequalification Charging Current VBAT = 2.8V 20 40 80 mA
BAT Leakage Current VDC = VUSB = 0, VBAT = 4.2V 5 µA
POK, CHG, AND THERMAL LIMIT
CHG Threshold Charge current where CHG goes high,
IBAT falling, 50mA hysteresis 25 50 100 mA
CHG, POK Logic-Low Output ICHG, IPOK = 10mA 150 300 mV
CHG, POK Leakage Current VCHG, VPOK = 6V, TA = +25°C 0.001 1 µA
Thermal-Limit Temperature Charge current reduced by 17mA/°C above this
temperature +110 °C