DKE15 15W DC-DC Regulated Dual Output Converter series Features : 2:1 wide input range 4:1 wide input range(optionl) 1000VDC I/O isolation 3000VDC I/O isolation(option) Built-in EMI filter Protections: Short circuit / Overload Cooling by free air convection Six-sided shield metal case 100% burn-in test Low cost / High reliability Approvals: FCC / CE 2 years warranty SPECIFICATION ORDER NO. DKE15A- DKE15B- DKE15C- DKE15A- DKE15B- DKE15C- DKE15A- DKE15B- DKE15C- DKE15A- DKE15B- DKE15C05 05 05 12 12 12 15 15 15 24 24 24 DC VOLTAGE 5V 12V 15V 24V CURRENT RANGE 150 ~ 1500mA 62.5 ~ 625mA 50 ~ 500mA 31.3 ~ 313mA RATED POWER 15W 60mVp-p 60mVp-p 80mVp-p RIPPLE & NOISE (max.) Note.2 50mVp-p LINE REGULATION Note.3 0.3% OUTPUT LOAD REGULATION Note.4 0.5% VOLTAGE ACCURACY 2.0% SWITCHING FREQUENCY 150KHz min. VOLTAGE RANGE A: 9 ~ 18VDC B: 18~36VDC 83% 81% 79% EFFICIENCY (Typ.) INPUT DC CURRENT Full load A: 1700mA B: 800mA C: 400mA No load A: 40mA C: 10mA FILTER Pi network Fuse recommended PROTECTION OTHERS 82% 83% SHORT CIRCUIT All output equipped with short circuit Protection type : Hiccup mode, recovers automatically after fault condition is removed 82% 84% 85% -25~+71 (Refer to "Derating Curve") ENVIRONMENT STORAGE TEMP., HUMIDITY TEMP. COEFFICIENT VIBRATION SAFETY STANDARDS EMC 82% 160% ~ 250% rated output power Protection type : Hiccup mode, recovers automatically after fault condition is removed WORKING TEMP. WORKING HUMIDITY SAFETY & B: 20mA 82% OVER CURRENT PROTECTION (Note. 5) C: 36~72VDC 82% 83% WITHSTAND VOLTAGE ISOLATION RESISTANCE EMC EMISSION EMC IMMUNITY 20% ~ 90% RH non-condensing -25 ~ +105, 10 ~ 95% RH 0.03% / ( 0 ~ 50) 10 ~ 500Hz, 2G 10min./1cycle, period for 60min. each along X, Y, Z axes EAC TP TC 004 approved I/P-O/P:1KVDC I/P-O/P: 100M Ohms / 500VDC / 25/ 70% RH MTBF DIMENSION Compliance to EN55032 Class A, FCC part 15 Class A , EAC TP TC 020 Compliance to EN61000-4-2,3,4,5,6,8, light industry level, criteria A , EAC TP TC 020 300Khrs min. MIL-HDBK-217F (25) 50.8*50.8*11.0mm or 2"*2"*0.43" inch (L*W*H) WEIGHT 65g Derating Curve Pin Configuration Mechanical Specification Unit: mm (inch) 5.8 (0.23) 1 2 4 5 10.20 10.20 (.402) (.402) 15.2 (.598) 22.8 (.898) 50.8 (.200) 5.10 (.200) 3 Pin No. Output 1 2 3 4 5 + Vi n - Vi n + Vo u t COM - Vo u t 11 (0.43) 20.30 (.800) 15.2 (.598) 100 LOAD (%) 50.8 (2.00) 80 BOTTOM VIEW 1.0 + 0.2/-0.1 -25 0 25 50 60 71 100 Ta () NOTE 1.All parameters are specified at normal input, rated load, 25 70% RH ambient. 2.Ripple & noise are measured at 20MHz by using a 12" twisted pair terminated with a 0.1uf & 47uf capacitor. 3.Line regulation is measured from low line to high line at rated load. 4.Load regulation is measured from 10% to 100% rated load. 5.Please prevent the converter from operating in overload or short circuit condition for more than 30 seconds. Product Liability DisclaimerFor detailed information, please refer to https://www.meanwell.com/serviceDisclaimer.aspx File Name:DKE15-SPEC 2020-10-30