Technical
Specification
IQ70-HP Family
Product # IQ70xxxHPXxx Phone 1-888-567-9596 www.synqor.com Doc.# 005-0005255 Rev. B 5/6/10 Page 1
The
InQor® Half-brick converter series is composed
of next-generation, board-mountable, isolated,
fixed switching frequency dc-dc converters that use
synchronous rectification to achieve extremely high
power conversion efficiency. Each module is supplied
completely encased to provide protection from the
harsh environments seen in many industrial and
transportation applications.
Operational Features
• Highefficiencies,upto91%atfullratedloadcurrent
• Deliversfullpowerwithminimalderating-noheatsinkrequired
• Operatinginputvoltagerange:34-135V
• FixedfrequencyswitchingprovidespredictableEMI
• Nominimumloadrequirement
Protection Features
• Inputunder-voltagelockout
• Outputcurrentlimitandshortcircuitprotection
• Activebackbiaslimit
• Thermalshutdown
Mechanical Features
• IndustrystandardHalf-brickpin-outconfiguration
• Standardsize:2.390"x2.490"x0.512"(60.6x63.1x13.0mm)
• Totalweight:5oz(142g)
Control Features
• On/Offcontrolreferencedtoinputside
• Remotesensefortheoutputvoltage
• Outputvoltagetrimrangeof-20%,+10%
Safety Features
• 2250V,30MW input-to-output isolation
• UL/cUL60950-1recognized(US&Canada),
basic insulation rating
• TUVcertifiedtoEN60950-1
• MeetsdirectiveswhichfacilitatesCEMarkinginuser’s
end product
• BoardandplasticcomponentsmeetUL94V-0standard
• RoHScompliant(seelastpage)
CONTENTS
PageNo.
MechanicalDiagram.......................................2
IQ70-HPFamilyElectricalCharacteristics . . . . . . . . . . . . . . . . . . . . . 3-4
IQ70-HPFamilyFigures . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .5
IQ70018HPx60(1.8V,60A)CharacteristicsandFigures . . . . . . . . . .6-7
IQ70033HPx57(3.3V,57A)CharacteristicsandFigures . . . . . . . . . .8-9
IQ70050HPx44(5.0V,44A)CharacteristicsandFigures . . . . . . . .10-11
IQ70120HPx20(12V,20A)CharacteristicsandFigures . . . . . . . . .12-13
IQ70150HPx16(15V,16A)CharacteristicsandFigures . . . . . . . . .14-15
IQ70240HPx10(24V,10A)CharacteristicsandFigures . . . . . . . . .16-17
IQ70280HPx8F(28V,8.5A)CharacteristicsandFigures . . . . . . . .18-19
IQ70400HPx06(40V,6.0A)CharacteristicsandFigures . . . . . . . .20-21
IQ70480HPx05(48V,5.0A)CharacteristicsandFigures . . . . . . . .22-23
ApplicationNotes....................................24-27
OrderingInformation ..................................... 28
34-135 V 1.8-48 V 240 W 2250 V dc Half-brick
Continuous Input Outputs Max Power Isolation DC-DC Converter
Technical
Specification
IQ70-HP Family
Product # IQ70xxxHPXxx Phone 1-888-567-9596 www.synqor.com Doc.# 005-0005255 Rev. F 5/6/10 Page 2
NOTES
1) Appliedtorqueperscrewshouldnotexceed6in-lb.(0.7Nm).
2) Baseplateflatnesstoleranceis0.004"(.10mm)TIRforsurface.
3) Pins1-3,5-7are0.040”(1.02mm)diameter,with0.080”
(2.03mm)diameterstandoffshoulders.
4) Pins4and8are0.080”(2.03mm)dia.with0.125”(3.18mm)dia.
standoff shoulders
5) AllPins:Material:CopperAlloy
Finish:MatteTinoverNickelplate
6) UndimensionedComponentsareshownforvisualreferenceonly
7) Weight:4.9oz(142g)
8) ThreadedorNon-Threadedoptionsavailable
9) Alldimensionsininches(mm)Tolerances:
x.xx+/-0.02in.(x.x+/-0.5mm)
x.xxx+/-0.010in.(x.xx+/-0.25mm)
PIN DESIGNATIONS
Pin Name Function
1 Vin(+) Positive input voltage
2 ON/OFF
TTLinputtoturnconverteron
andoff,referencedtoVin(–),with
internal pull up.
3 Vin(–) Negativeinputvoltage
4 Vout(–) Negativeoutputvoltage
5 SENSE(–) Negativeremotesense1
6 TRIM Outputvoltagetrim2
7SENSE(+) Positive remote sense3
8 Vout(+) Positive output voltage
Notes:
1) SENSE(–)shouldbeconnectedtoVout(–)either
remotely or at the converter.
2) LeaveTRIMpinopenfornominaloutputvoltage.
3) SENSE(+)shouldbeconnectedtoVout(+)
either remotely or at the converter.
1.90
[ 48,3 ]
.400 [ 10,16 ]
1.400 [ 35,56 ]
.400 [ 10,16 ]
.700 [ 17,78 ]
1.000 [ 25,4 ]
1.400 [ 35,56 ]
2.386 ±.020
[ 60,6 ±0,5 ]
.233 ±.020
[ 5,92 ±0,5 ]
.543 ±.020 [ 13,79 ±0,5]
1.90
[ 48,3 ]
2.486 ±.020 [ 63,14 ±0,5 ]
.243 ±.020
[ 6,17 ±0,5 ]
.243 ±.020
[ 6,17 ±0,5]
2.00 [ 50,8 ]
+.002
.512 -.005
+0,05
13
[-0,12 ]
OVERALL
HEIGHT
+.007
.027 -.010
+0,17
0,69
[-0,25 ]
BOTTOMSIDE CLEARANCE
.163
[ 4,14 ]
123
4
5
6
7
8
SIDE VIEW
TOP VIEW
THRU HOLE
M3 (SEE NOTE 8)
STANDOFFS (4)
IQ70-HPMechanicalDiagram
Technical
Specification
IQ70-HP Family
Product # IQ70xxxHPXxx Phone 1-888-567-9596 www.synqor.com Doc.# 005-0005255 Rev. B 5/6/10 Page 3
IQ70 FAMILY ELECTRICAL CHARACTERISTICS (all output voltages)
Ta=25°C,airflowrate=300LFM,Vin=70Vdcunlessotherwisenoted;fulloperatingtemperaturerangeis-40°Cto+100°Cbaseplate
temperaturewithappropriatepowerderating.Specificationssubjecttochangewithoutnotice.
Parameter Min. Typ. Max. Units Notes & Conditions
ABSOLUTE MAXIMUM RATINGS
InputVoltage
Non-Operating 150 V Continuous
Operating 135 V Continuous
OperatingTransientProtection -V
IsolationVoltage
InputtoOutput 2250 Vdc
InputtoBase-Plate 2250 Vdc
OutputtoBase-Plate 2250 Vdc
OperatingTemperature -40 100 °C Baseplatetemperature
StorageTemperature -55 125 °C
VoltageatON/OFFinputpin -2 18 V
INPUT CHARACTERISTICS
OperatingInputVoltageRange 34 70 135 V
InputUnder-VoltageLockout
Turn-OnVoltageThreshold 32.7 33.1 33.5 V
Turn-OffVoltageThreshold 30.4 30.8 31.2 V
LockoutVoltageHysteresis 2.3 V
InputOver-VoltageShutdown -V
RecommendedExternalInputCapacitance 100 µF TypicalESR0.1-0.2Ω
InputFilterComponentValues(L\C) 3.4\4.0 µH\µF Internalvalues;seeFigureE
DYNAMIC CHARACTERISTICS
Turn-OnTransient
Turn-OnTime 10 ms Fullload,Vout=90%nom.
Start-UpInhibitTime 200 230 250 ms FigureF
OutputVoltageOvershoot 0 % MaximumOutputCapacitance
ISOLATION CHARACTERISTICS
IsolationVoltage(dielectricstrength) SeeAbsoluteMaximumRatings
IsolationResistance 30
IsolationCapacitance(inputtooutput) 1000 pF SeeNote1
TEMPERATURE LIMITS FOR POWER DERATING CURVES
SemiconductorJunctionTemperature 125 °C Packageratedto150°C
BoardTemperature 125 °C ULratedmaxoperatingtemp130°C
Transformer Temperature 125 °C
MaximumBaseplateTemperature,Tb 100 °C
FEATURE CHARACTERISTICS
SwitchingFrequency 255 275 295 kHz Isolation stage switching freq. is half this
ON/OFFControl
Off-StateVoltage 2.4 1.8 V
On-StateVoltage -2 0.8
ON/OFFControl ApplicationnotesFiguresA&B
Pull-UpVoltage 5 V
Pull-UpResistance 50
Over-TemperatureShutdownOTPTripPoint 125 °C AveragePCBTemperature
Over-TemperatureShutdownRestartHysteresis 10 °C
RELIABILITY CHARACTERISTICS
CalculatedMTBF(Telcordia)TR-NWT-000332 TBD 106 Hrs. 80%load,200LFM,40°CTa
CalculatedMTBF(MIL-217)MIL-HDBK-217F TBD 106 Hrs. 80%load,200LFM,40°CTa
FieldDemonstratedMTBF 106 Hrs. Seeourwebsitefordetails
Note1:Highervaluesofisolationcapacitancecanbeaddedexternaltothemodule.
Technical
Specification
IQ70-HP Family
Product # IQ70xxxHPXxx Phone 1-888-567-9596 www.synqor.com Doc.# 005-0005255 Rev. B 5/6/10 Page 4
STANDARDSCOMPLIANCE
Parameter Notes&Conditions
STANDARDSCOMPLIANCE
UL/cUL60950-1 File#E194341,Basicinsulation
EN60950-1 CertiedbyTUV
NeedleFlameTest(IEC695-2-2) Testonentireassembly;board&plasticcomponentsUL94V-0compliant
IEC61000-4-2 ESDtest,8kV-NP,15kVair-NP(NormalPerformance)
Note:Anexternalinputfusemustalwaysbeusedtomeetthesesafetyrequirements.ContactSynQorforofcialsafetycerticatesonnew
releasesordownloadfromtheSynQorwebsite.
QUALIFICATIONTESTING
Parameter #Units TestConditions
QUALIFICATIONTESTING
LifeTest 32 95%ratedVinandload,unitsatderatingpoint,1000hours
Vibration 5 10-55Hzsweep,0.060"totalexcursion,1min./sweep,120sweepsfor3axis
MechanicalShock 5 100gminimum,2dropsinxandyaxis,1dropinzaxis
TemperatureCycling 10 -40°Cto100°C,unittemp.ramp15°C/min.,500cycles
Power/ThermalCycling 5 Toperating=mintomax,Vin=mintomax,fullload,100cycles
DesignMarginality 5 Tmin-10°CtoTmax+10°C,5°Csteps,Vin=mintomax,0-105%load
Humidity 5 85°C,85%RH,1000hours,continuousVinappliedexcept5min/day
Solderability 15pins MIL-STD-883,method2003
Technical
Specification
IQ70-HP Family
Product # IQ70xxxHPXxx Phone 1-888-567-9596 www.synqor.com Doc.# 005-0005255 Rev. B 5/6/10 Page 5
Common Figure 3: Trim graph for trim-up 1.8 to 12 V outputs.
0
20
40
60
80
100
120
0 10 20 30 40 50 60 70 80 90 100 110 120 130 140 150
Load Current (%)
Output Voltage (%)
Vin min
Vin nom
Vin max
Typical Current Limit Inception Point
Typical Output Voltage at Shutdown
Common Figure 1: Typical startup waveform. Input voltage pre-applied,
ON/OFF Pin on Ch 2. Common Figure 2: Output voltage vs. load current showing typical
current limit curves and converter shutdown points.
100.0
1,000.0
10,000.0
100,000.0
0 1 2 3 4 5 6 7 8 9 10 11 12 13 14 15
Increase in Vout (%)
Trim Resistance (kOhms)
15 V 24 V 28 V 40 V 48 V
10.0
100.0
1,000.0
10,000.0
100,000.0
0 1 2 3 4 5 6 7 8 9 10 11 12 13 14 15
Increase in Vout (%)
Trim Resistance (kOhms)
1.8 V 3.3 V 5 V 12 V
10.0
100.0
1,000.0
10,000.0
0 1 2 3 4 5 6 7 8 9 10 11 12 13 14 15 16 17 18 19 20
Decrease in Vout (%)
Trim Resistance (kOhms)
All voltages
Common Figure 5
: Trim graph for trim down.
Common Figure 4: Trim graph for trim-up 15 to 48 V outputs.
Nominal Vout
IQ70 FAMILY FIGURES (all output voltages)
5.00
Product # IQ70xxxHPXxx Phone 1-888-567-9596 www.synqor.com Doc.# 005-0005255 Rev. B 5/6/10 Page 6
Technical Specification
Input:
Output:
Current:
Part No.:
34 - 135 V
1.8 V
60 A
IQ70018HPx60
IQ70018HPx60 ELECTRICAL CHARACTERISTICS (1.8 Vout)
Ta=25°C,airflowrate=300LFM,Vin=70Vdcunlessotherwisenoted;fulloperatingtemperaturerangeis-40°Cto+100°Cbaseplate
temperaturewithappropriatepowerderating.Specificationssubjecttochangewithoutnotice.
Parameter Min. Typ. Max. Units Notes & Conditions
INPUT CHARACTERISTICS
MaximumInputCurrent 4.6 A Vinmin;1.8Vout;incurrentlimit(typ)
No-LoadInputCurrent 45 60 mA
DisabledInputCurrent 2.5 4 mA
ResponsetoInputTransient 0.12 V 500V/ms,seeFigure6
InputTerminalRippleCurrent 230 mA RMS
RecommendedInputFuse 15 A Fastactingexternalfuserecommended
OUTPUT CHARACTERISTICS
OutputVoltageSetPoint 1.782 1.8 1.818 V
OutputVoltageRegulation
OverLine ±0.1 ±0.3 %
OverLoad ±0.1 ±0.3 %
OverTemperature -27 27 mV
TotalOutputVoltageRange 1.755 1.845 V Oversample,line,load,temperature&life
OutputVoltageRippleandNoise 20MHzbandwidth;seeNote1
Peak-to-Peak 0 70 140 mV Fullload
RMS 14 30 mV Fullload
OperatingOutputCurrentRange 0 60 ASubjecttothermalderating
OutputDCCurrent-LimitInception 66.0 72.0 78.0 A Outputvoltage10%Low
OutputDCCurrent-LimitShutdownVoltage 0.8 V
Back-DriveCurrentLimitwhileEnabled 1.9 A Negativecurrentdrawnfromoutput
Back-DriveCurrentLimitwhileDisabled 0.1 mA Negativecurrentdrawnfromoutput
MaximumOutputCapacitance 15,000 µF Voutnominalatfullload(resistiveload)
OutputVoltageduringLoadCurrentTransient
StepChangeinOutputCurrent(0.1A/µs) 70 mV 50%to75%to50%Ioutmax
SettlingTime 500 µs Towithin1%Voutnom
OutputVoltageTrimRange -20 10 % AcrossPins8&4;CommonFigures3-5;SeeNote2
OutputVoltageRemoteSenseRange 10 % AcrossPins8&4
OutputOver-VoltageProtection 2.1 2.2 2.3 V Overfulltemprange
EFFICIENCY
100%Load 83 % SeeFigure1forefficiencycurve
50%Load 88 % SeeFigure1forefficiencycurve
Note1:Outputisterminatedwith1µFceramicand15µFlow-ESRtantalumcapacitors.Forapplicationsrequiringreducedoutputvoltagerippleand
noise,consultSynQorapplicationssupport(e-mail:support@synqor.com)
Note2:Trim-uprangeislimitedbelow10%atlowlineandfullload.
Product # IQ70xxxHPXxx Phone 1-888-567-9596 www.synqor.com Doc.# 005-0005255 Rev. B 5/6/10 Page 7
Technical Specification
Input:
Output:
Current:
Part No.:
Figure 1: Efficiency at nominal output voltage vs. load current for
minimum, nominal, and maximum input voltage at 25
°
C. Figure 2: Power dissipation at nominal output voltage vs. load current
for minimum, nominal, and maximum input voltage at 25
°
C.
Figure 3: Encased converter (without heatsink) max. output power derating vs.
ambient air temperature for airflow rates of 100 LFM through 400 LFM. Air flows
across the converter from input to output (nominal input voltage).
Figure 4: Encased converter (with 1/2 heatsink) max. output power derating vs.
ambient air temperature for airflow rates of 100 LFM through 400 LFM. Air flows
across the converter from input to output (nominal input voltage).
Figure 6: Output voltage response to step-change in input voltage
(500 V/ms). Load cap: 100
µ
F, electrolytic output capacitance.
Ch 1: Vout (200 mV/div), Ch 2: Vin (50 V/div).
Figure 5: Output voltage response to step-change in load current (50%-
75%-50% of Iout(max); dI/dt = 0.1 A
s
). Load cap: 15
µF Tantalum
+ 1
µ
F
Ceramic capacitor. Ch 1: Vout (200 mV/div), Ch 2: Iout (25 A/div).
34 - 135 V
1.8 V
60 A
IQ70018HPx60
34 - 135 V
1.8 V
60 A
IQ70018HPx60
0
3
6
9
12
15
18
21
24
27
0 5 10 15 20 25 30 35 40 45 50 55 60
Load Current (A)
Power Dissipation (W)
34 Vin
70 Vin
135 Vin
0
10
20
30
40
50
60
70
25 40 55 70 85
Ambient Air Temperature (°C)
Iout (A)
400 LFM (2.0 m/s)
300 LFM (1.5 m/s)
200 LFM (1.0 m/s)
100 LFM (0.5 m/s)
0
10
20
30
40
50
60
70
25 40 55 70 85
Ambient Air Temperature (°C)
Iout (A)
400 LFM (2.0 m/s)
300 LFM (1.5 m/s)
200 LFM (1.0 m/s)
100 LFM (0.5 m/s)
60
65
70
75
80
85
90
95
100
0 5 10 15 20 25 30 35 40 45 50 55 60
Load Current (A)
Efficiency (%)
34 Vin
70 Vin
135 Vin
Product # IQ70xxxHPXxx Phone 1-888-567-9596 www.synqor.com Doc.# 005-0005255 Rev. B 5/6/10 Page 8
Technical Specification
Input:
Output:
Current:
Part No.:
34 - 135 V
3.3 V
57 A
IQ70033HPx57
IQ70033HPx57 ELECTRICAL CHARACTERISTICS (3.3 Vout)
Ta=25°C,airflowrate=300LFM,Vin=70Vdcunlessotherwisenoted;fulloperatingtemperaturerangeis-40°Cto+100°Cbaseplate
temperaturewithappropriatepowerderating.Specificationssubjecttochangewithoutnotice.
Parameter Min. Typ. Max. Units Notes & Conditions
INPUT CHARACTERISTICS
MaximumInputCurrent 7.5 A Vinmin;3.3Vout;incurrentlimit(typ)
No-LoadInputCurrent 50 60 mA
DisabledInputCurrent 2 3 mA
ResponsetoInputTransient 0.24 V 500V/ms,seeFigure6
InputTerminalRippleCurrent 370 mA RMS
RecommendedInputFuse 15 A Fastactingexternalfuserecommended
OUTPUT CHARACTERISTICS
OutputVoltageSetPoint 3.267 3.3 3.333 V
OutputVoltageRegulation
OverLine ±0.1 ±0.3 %
OverLoad ±0.1 ±0.3 %
OverTemperature -50 50 mV
TotalOutputVoltageRange 3.218 3.383 V Oversample,line,load,temperature&life
OutputVoltageRippleandNoise 20MHzbandwidth;seeNote1
Peak-to-Peak 0 180 360 mV Fullload
RMS 25 50 mV Fullload
OperatingOutputCurrentRange 0 57 ASubjecttothermalderating
OutputDCCurrent-LimitInception 62.7 68.4 74.1 A Outputvoltage10%Low
OutputDCCurrent-LimitShutdownVoltage 1.7 V
Back-DriveCurrentLimitwhileEnabled 1.2 A Negativecurrentdrawnfromoutput
Back-DriveCurrentLimitwhileDisabled 0.1 mA Negativecurrentdrawnfromoutput
MaximumOutputCapacitance 10,000 µF Voutnominalatfullload(resistiveload)
OutputVoltageduringLoadCurrentTransient
StepChangeinOutputCurrent(0.1A/µs) 80 mV 50%to75%to50%Ioutmax
SettlingTime 400 µs Towithin1%Voutnom
OutputVoltageTrimRange -20 10 % AcrossPins8&4;CommonFigures3-5;SeeNote2
OutputVoltageRemoteSenseRange 10 % AcrossPins8&4
OutputOver-VoltageProtection 3.9 4.0 4.2 V Overfulltemprange
EFFICIENCY
100%Load 88 % SeeFigure1forefficiencycurve
50%Load 91 % SeeFigure1forefficiencycurve
Note1:Outputisterminatedwith1µFceramicand15µFlow-ESRtantalumcapacitors.Forapplicationsrequiringreducedoutputvoltagerippleand
noise,consultSynQorapplicationssupport(e-mail:support@synqor.com)
Note2:Trim-uprangeislimitedbelow10%atlowlineandfullload.
Product # IQ70xxxHPXxx Phone 1-888-567-9596 www.synqor.com Doc.# 005-0005255 Rev. B 5/6/10 Page 9
Technical Specification
Input:
Output:
Current:
Part No.:
Figure 1: Efficiency at nominal output voltage vs. load current for
minimum, nominal, and maximum input voltage at 25
°
C. Figure 2: Power dissipation at nominal output voltage vs. load current
for minimum, nominal, and maximum input voltage at 25
°
C.
Figure 3: Encased converter (without heatsink) max. output power derating vs.
ambient air temperature for airflow rates of 100 LFM through 400 LFM. Air flows
across the converter from input to output (nominal input voltage).
Figure 4: Encased converter (with 1/2 heatsink) max. output power derating vs.
ambient air temperature for airflow rates of 100 LFM through 400 LFM. Air flows
across the converter from input to output (nominal input voltage).
Figure 6: Output voltage response to step-change in input voltage
(500 V/ms). Load cap: 100
µ
F, electrolytic output capacitance.
Ch 1: Vout (500 mV/div), Ch 2: Vin (50 V/div).
Figure 5: Output voltage response to step-change in load current (50%-75%-
50% of Iout(max); dI/dt = 0.1 A/µ
s
). Load cap: 15
µF Tantalum
+ 1
µ
F Ceramic
capacitor. Ch 1: Vout (200 mV/div), Ch 2: Iout (25 A/div).
0
6
12
18
24
30
36
42
48
54
60
25 40 55 70 85
Ambient Air Temperature (°C)
Iout (A)
400 LFM (2.0 m/s)
300 LFM (1.5 m/s)
200 LFM (1.0 m/s)
100 LFM (0.5 m/s)
0
6
12
18
24
30
36
42
48
54
60
25 40 55 70 85
Ambient Air Temperature (°C)
Iout (A)
400 LFM (2.0 m/s)
300 LFM (1.5 m/s)
200 LFM (1.0 m/s)
100 LFM (0.5 m/s)
0
3
6
9
12
15
18
21
24
27
30
0 6 12 18 24 30 36 42 48 54 60
Load Current (A)
Power Dissipation (W)
34 Vin
70 Vin
135 Vin
60
65
70
75
80
85
90
95
100
0 6 12 18 24 30 36 42 48 54 60
Load Current (A)
Efficiency (%)
34 Vin
70 Vin
135 Vin
34 - 135 V
3.3 V
57 A
IQ70033HPx57
34 - 135 V
3.3 V
57 A
IQ70033HPx57
Product # IQ70xxxHPXxx Phone 1-888-567-9596 www.synqor.com Doc.# 005-0005255 Rev. B 5/6/10 Page 10
Technical Specification
Input:
Output:
Current:
Part No.:
34 - 135 V
5.0 V
44 A
IQ70050HPx44
IQ70050HPx44 ELECTRICAL CHARACTERISTICS (5.0 Vout)
Ta=25°C,airflowrate=300LFM,Vin=70Vdcunlessotherwisenoted;fulloperatingtemperaturerangeis-40°Cto+100°Cbaseplate
temperaturewithappropriatepowerderating.Specificationssubjecttochangewithoutnotice.
Parameter Min. Typ. Max. Units Notes & Conditions
INPUT CHARACTERISTICS
MaximumInputCurrent 9.0 A Vinmin;5Vout;incurrentlimit(typ)
No-LoadInputCurrent 45 60 mA
DisabledInputCurrent 2 3 mA
ResponsetoInputTransient 0.35 V 500V/ms,seeFigure6
InputTerminalRippleCurrent 450 mA RMS
RecommendedInputFuse 15 A Fastactingexternalfuserecommended
OUTPUT CHARACTERISTICS
OutputVoltageSetPoint 4.95 5 5.05 V
OutputVoltageRegulation
OverLine ±0.1 ±0.3 %
OverLoad ±0.1 ±0.3 %
OverTemperature -75 75 mV
TotalOutputVoltageRange 4.875 5.125 V Oversample,line,load,temperature&life
OutputVoltageRippleandNoise 20MHzbandwidth;seeNote1
Peak-to-Peak 0 170 340 mV Fullload
RMS 23 50 mV Fullload
OperatingOutputCurrentRange 0 44 ASubjecttothermalderating
OutputDCCurrent-LimitInception 48.4 52.8 57.2 A Outputvoltage10%Low
OutputDCCurrent-LimitShutdownVoltage 2.7 V
Back-DriveCurrentLimitwhileEnabled 0.55 A Negativecurrentdrawnfromoutput
Back-DriveCurrentLimitwhileDisabled 0.4 mA Negativecurrentdrawnfromoutput
MaximumOutputCapacitance 8,000 µF Voutnominalatfullload(resistiveload)
OutputVoltageduringLoadCurrentTransient
StepChangeinOutputCurrent(0.1A/µs) 200 mV 50%to75%to50%Ioutmax
SettlingTime 400 µs Towithin1%Voutnom
OutputVoltageTrimRange -20 10 % AcrossPins8&4;CommonFigures3-5;SeeNote2
OutputVoltageRemoteSenseRange 10 % AcrossPins8&4
OutputOver-VoltageProtection 5.9 6.1 6.4 V Overfulltemprange
EFFICIENCY
100%Load 87 % SeeFigure1forefficiencycurve
50%Load 90 % SeeFigure1forefficiencycurve
Note1:Outputisterminatedwith1µFceramicand15µFlow-ESRtantalumcapacitors.Forapplicationsrequiringreducedoutputvoltagerippleand
noise,consultSynQorapplicationssupport(e-mail:support@synqor.com)
Note2:Trim-uprangeislimitedbelow10%atlowlineandfullload.
Product # IQ70xxxHPXxx Phone 1-888-567-9596 www.synqor.com Doc.# 005-0005255 Rev. B 5/6/10 Page 11
Technical Specification
Input:
Output:
Current:
Part No.:
Figure 1: Efficiency at nominal output voltage vs. load current for
minimum, nominal, and maximum input voltage at 25
°
C. Figure 2: Power dissipation at nominal output voltage vs. load current
for minimum, nominal, and maximum input voltage at 25
°
C.
Figure 3: Encased converter (without heatsink) max. output power derating vs.
ambient air temperature for airflow rates of 100 LFM through 400 LFM. Air flows
across the converter from input to output (nominal input voltage).
Figure 4: Encased converter (with 1/2 heatsink) max. output power derating vs.
ambient air temperature for airflow rates of 100 LFM through 400 LFM. Air flows
across the converter from input to output (nominal input voltage).
Figure 6: Output voltage response to step-change in input voltage
(500 V/ms). Load cap: 100
µ
F, electrolytic output capacitance.
Ch 1: Vout (500 mV/div), Ch 2: Vin (50 V/div).
Figure 5: Output voltage response to step-change in load current (50%-75%-
50% of Iout(max); dI/dt = 0.1 A/µ
s
). Load cap: 15
µF Tantalum
+ 1
µ
F Ceramic
capacitor. Ch 1: Vout (500 mV/div), Ch 2: Iout (10 A/div).
0
4
8
12
16
20
24
28
32
36
40
44
48
25 40 55 70 85
Ambient Air Temperature (°C)
Iout (A)
400 LFM (2.0 m/s)
300 LFM (1.5 m/s)
200 LFM (1.0 m/s)
100 LFM (0.5 m/s)
0
4
8
12
16
20
24
28
32
36
40
44
48
25 40 55 70 85
Ambient Air Temperature (°C)
Iout (A)
400 LFM (2.0 m/s)
300 LFM (1.5 m/s)
200 LFM (1.0 m/s)
100 LFM (0.5 m/s)
0
5
10
15
20
25
30
35
40
0 4 8 12 16 20 24 28 32 36 40 44
Load Current (A)
Power Dissipation (W)
34 Vin
70 Vin
135 Vin
60
65
70
75
80
85
90
95
100
0 4 8 12 16 20 24 28 32 36 40 44
Load Current (A)
Efficiency (%)
34 Vin
70 Vin
135 Vin
34 - 135 V
5.0 V
44 A
IQ70050HPx44
34 - 135 V
5.0 V
44 A
IQ70050HPx44
Product # IQ70xxxHPXxx Phone 1-888-567-9596 www.synqor.com Doc.# 005-0005255 Rev. B 5/6/10 Page 12
Technical Specification
Input:
Output:
Current:
Part No.:
34 - 135 V
12 V
20 A
IQ70120HPx20
IQ70120HPx20 ELECTRICAL CHARACTERISTICS (12 Vout)
Ta=25°C,airflowrate=300LFM,Vin=70Vdcunlessotherwisenoted;fulloperatingtemperaturerangeis-40°Cto+100°Cbaseplate
temperaturewithappropriatepowerderating.Specificationssubjecttochangewithoutnotice.
Parameter Min. Typ. Max. Units Notes & Conditions
INPUT CHARACTERISTICS
MaximumInputCurrent 9.3 A Vinmin;12Vout;incurrentlimit(typ)
No-LoadInputCurrent 55 70 mA
DisabledInputCurrent 2 3 mA
ResponsetoInputTransient 0.75 V 500V/ms,seeFigure6
InputTerminalRippleCurrent 430 mA RMS
RecommendedInputFuse 15 A Fastactingexternalfuserecommended
OUTPUT CHARACTERISTICS
OutputVoltageSetPoint 11.88 12 12.12 V
OutputVoltageRegulation
OverLine ±0.1 ±0.3 %
OverLoad ±0.1 ±0.3 %
OverTemperature -180 180 mV
TotalOutputVoltageRange 11.700 12.300 V Oversample,line,load,temperature&life
OutputVoltageRippleandNoise 20MHzbandwidth;seeNote1
Peak-to-Peak 0 100 200 mV Fullload
RMS 13 30 mV Fullload
OperatingOutputCurrentRange 0 20 ASubjecttothermalderating
OutputDCCurrent-LimitInception 22.0 24.0 26.0 A Outputvoltage10%Low
OutputDCCurrent-LimitShutdownVoltage 6.5 V
Back-DriveCurrentLimitwhileEnabled 0.5 A Negativecurrentdrawnfromoutput
Back-DriveCurrentLimitwhileDisabled 1 mA Negativecurrentdrawnfromoutput
MaximumOutputCapacitance 1,500 µF Voutnominalatfullload(resistiveload)
OutputVoltageduringLoadCurrentTransient
StepChangeinOutputCurrent(0.1A/µs) 270 mV 50%to75%to50%Ioutmax
SettlingTime 100 µs Towithin1%Voutnom
OutputVoltageTrimRange -20 10 % AcrossPins8&4;CommonFigures3-5;seeNote2
OutputVoltageRemoteSenseRange 10 % AcrossPins8&4
OutputOver-VoltageProtection 14.0 14.6 15.3 V Overfulltemprange
EFFICIENCY
100%Load 91 % SeeFigure1forefficiencycurve
50%Load 93 % SeeFigure1forefficiencycurve
Note1:Outputisterminatedwith1µFceramicand15µFlow-ESRtantalumcapacitors.Forapplicationsrequiringreducedoutputvoltagerippleand
noise,consultSynQorapplicationssupport(e-mail:support@synqor.com)
Note2:Trim-uprangeislimitedbelow10%atlowlineandfullload.
Product # IQ70xxxHPXxx Phone 1-888-567-9596 www.synqor.com Doc.# 005-0005255 Rev. B 5/6/10 Page 13
Technical Specification
Input:
Output:
Current:
Part No.:
Figure 1: Efficiency at nominal output voltage vs. load current for
minimum, nominal, and maximum input voltage at 25
°
C. Figure 2: Power dissipation at nominal output voltage vs. load current
for minimum, nominal, and maximum input voltage at 25
°
C.
Figure 3: Encased converter (without heatsink) max. output power derating vs.
ambient air temperature for airflow rates of 100 LFM through 400 LFM. Air flows
across the converter from input to output (nominal input voltage).
Figure 4: Encased converter (with 1/2 heatsink) max. output power derating vs.
ambient air temperature for airflow rates of 100 LFM through 400 LFM. Air flows
across the converter from input to output (nominal input voltage).
Figure 6: Output voltage response to step-change in input voltage
(500 V/ms). Load cap: 100
µ
F, electrolytic output capacitance.
Ch 1: Vout (1 V/div), Ch 2: Vin (50 V/div).
Figure 5: Output voltage response to step-change in load current (50%-75%-
50% of Iout(max); dI/dt = 0.1 A/µ
s
). Load cap: 15
µF Tantalum
+ 1
µ
F Ceramic
capacitor. Ch 1: Vout (500 mV/div), Ch 2: Iout (10 A/div).
0
2
4
6
8
10
12
14
16
18
20
22
25 40 55 70 85
Ambient Air Temperature (°C)
Iout (A)
400 LFM (2.0 m/s)
300 LFM (1.5 m/s)
200 LFM (1.0 m/s)
100 LFM (0.5 m/s)
0
2
4
6
8
10
12
14
16
18
20
22
25 40 55 70 85
Ambient Air Temperature (°C)
Iout (A)
400 LFM (2.0 m/s)
300 LFM (1.5 m/s)
200 LFM (1.0 m/s)
100 LFM (0.5 m/s)
0
3
6
9
12
15
18
21
24
27
30
0 2 4 6 8 10 12 14 16 18 20
Load Current (A)
Power Dissipation (W)
34 Vin
70 Vin
135 Vin
60
65
70
75
80
85
90
95
100
0 2 4 6 8 10 12 14 16 18 20
Load Current (A)
Efficiency (%)
34 Vin
70 Vin
135 Vin
34 - 135 V
12 V
20 A
IQ70120HPx20
34 - 135 V
12 V
20 A
IQ70120HPx20
Product # IQ70xxxHPXxx Phone 1-888-567-9596 www.synqor.com Doc.# 005-0005255 Rev. B 5/6/10 Page 14
Technical Specification
Input:
Output:
Current:
Part No.:
34 - 135 V
15 V
16 A
IQ70150HPx16
IQ70150HPx16 ELECTRICAL CHARACTERISTICS (15 Vout)
Ta=25°C,airflowrate=300LFM,Vin=70Vdcunlessotherwisenoted;fulloperatingtemperaturerangeis-40°Cto+100°Cbaseplate
temperaturewithappropriatepowerderating.Specificationssubjecttochangewithoutnotice.
Parameter Min. Typ. Max. Units Notes & Conditions
INPUT CHARACTERISTICS
MaximumInputCurrent 9.4 A Vinmin;12Vout;incurrentlimit(typ)
No-LoadInputCurrent 55 70 mA
DisabledInputCurrent 2 3 mA
ResponsetoInputTransient 0.9 V 500V/ms,seeFigure6
InputTerminalRippleCurrent 490 mA RMS
RecommendedInputFuse 15 A Fastactingexternalfuserecommended
OUTPUT CHARACTERISTICS
OutputVoltageSetPoint 14.85 15 15.15 V
OutputVoltageRegulation
OverLine ±0.1 ±0.3 %
OverLoad ±0.1 ±0.3 %
OverTemperature -225 225 mV
TotalOutputVoltageRange 14.625 15.375 V Oversample,line,load,temperature&life
OutputVoltageRippleandNoise 20MHzbandwidth;seeNote1
Peak-to-Peak 0 130 260 mV Fullload
RMS 22 40 mV Fullload
OperatingOutputCurrentRange 0 16 ASubjecttothermalderating
OutputDCCurrent-LimitInception 17.6 19.2 20.8 A Outputvoltage10%Low
OutputDCCurrent-LimitShutdownVoltage 8.5 V
Back-DriveCurrentLimitwhileEnabled 0.35 A Negativecurrentdrawnfromoutput
Back-DriveCurrentLimitwhileDisabled 1.5 mA Negativecurrentdrawnfromoutput
MaximumOutputCapacitance 1,000 µF Voutnominalatfullload(resistiveload)
OutputVoltageduringLoadCurrentTransient
StepChangeinOutputCurrent(0.1A/µs) 500 mV 50%to75%to50%Ioutmax
SettlingTime 80 µs Towithin1%Voutnom
OutputVoltageTrimRange -20 10 % AcrossPins8&4;CommonFigures3-5;seeNote2
OutputVoltageRemoteSenseRange 10 % AcrossPins8&4
OutputOver-VoltageProtection 17.6 18.3 19.1 V Overfulltemprange
EFFICIENCY
100%Load 90 % SeeFigure1forefficiencycurve
50%Load 93 % SeeFigure1forefficiencycurve
Note1:Outputisterminatedwith1µFceramicand15µFlow-ESRtantalumcapacitors.Forapplicationsrequiringreducedoutputvoltagerippleand
noise,consultSynQorapplicationssupport(e-mail:support@synqor.com)
Note2:Trim-uprangeislimitedbelow10%atlowlineandfullload.
Product # IQ70xxxHPXxx Phone 1-888-567-9596 www.synqor.com Doc.# 005-0005255 Rev. B 5/6/10 Page 15
Technical Specification
Input:
Output:
Current:
Part No.:
Figure 1: Efficiency at nominal output voltage vs. load current for
minimum, nominal, and maximum input voltage at 25
°
C. Figure 2: Power dissipation at nominal output voltage vs. load current
for minimum, nominal, and maximum input voltage at 25
°
C.
Figure 3: Encased converter (without heatsink) max. output power derating vs.
ambient air temperature for airflow rates of 100 LFM through 400 LFM. Air flows
across the converter from input to output (nominal input voltage).
Figure 4: Encased converter (with 1/2 heatsink) max. output power derating vs.
ambient air temperature for airflow rates of 100 LFM through 400 LFM. Air flows
across the converter from input to output (nominal input voltage).
Figure 6: Output voltage response to step-change in input voltage
(500 V/ms). Load cap: 100
µ
F, electrolytic output capacitance.
Ch 1: Vout (1 V/div), Ch 2: Vin (50 V/div).
Figure 5: Output voltage response to step-change in load current (50%-75%-
50% of Iout(max); dI/dt = 0.1 A/µ
s
). Load cap: 15
µF Tantalum
+ 1
µ
F Ceramic
capacitor. Ch 1: Vout (1 V/div), Ch 2: Iout (5 A/div).
0
2
4
6
8
10
12
14
16
18
25 40 55 70 85
Ambient Air Temperature (°C)
Iout (A)
400 LFM (2.0 m/s)
300 LFM (1.5 m/s)
200 LFM (1.0 m/s)
100 LFM (0.5 m/s)
0
2
4
6
8
10
12
14
16
18
25 40 55 70 85
Ambient Air Temperature (°C)
Iout (A)
400 LFM (2.0 m/s)
300 LFM (1.5 m/s)
200 LFM (1.0 m/s)
100 LFM (0.5 m/s)
0
5
10
15
20
25
30
35
0 1 2 3 4 5 6 7 8 9 10 11 12 13 14 15 16
Load Current (A)
Power Dissipation (W)
34 Vin
70 Vin
135 Vin
60
65
70
75
80
85
90
95
100
0 1 2 3 4 5 6 7 8 9 10 11 12 13 14 15 16
Load Current (A)
Efficiency (%)
34 Vin
70 Vin
135 Vin
34 - 135 V
15 V
16 A
IQ70150HPx16
34 - 135 V
15 V
16 A
IQ70150HPx16
Product # IQ70xxxHPXxx Phone 1-888-567-9596 www.synqor.com Doc.# 005-0005255 Rev. B 5/6/10 Page 16
Technical Specification
Input:
Output:
Current:
Part No.:
34 - 135 V
24 V
10 A
IQ70240HPx10
IQ70240HPx10 ELECTRICAL CHARACTERISTICS (24 Vout)
Ta=25°C,airflowrate=300LFM,Vin=70Vdcunlessotherwisenoted;fulloperatingtemperaturerangeis-40°Cto+100°Cbaseplate
temperaturewithappropriatepowerderating.Specificationssubjecttochangewithoutnotice.
Parameter Min. Typ. Max. Units Notes & Conditions
INPUT CHARACTERISTICS
MaximumInputCurrent 10.5 A Vinmin;trim-up;incurrentlimit(typ)
No-LoadInputCurrent 45 60 mA
DisabledInputCurrent 2.5 4 mA
ResponsetoInputTransient 1.3 V 500V/ms,seeFigure6
InputTerminalRippleCurrent 500 mA RMS
RecommendedInputFuse 15 A Fastactingexternalfuserecommended
OUTPUT CHARACTERISTICS
OutputVoltageSetPoint 23.76 24 24.24 V
OutputVoltageRegulation
OverLine ±0.1 ±0.3 %
OverLoad ±0.1 ±0.3 %
OverTemperature -360 360 mV
TotalOutputVoltageRange 23.40 24.60 V Oversample,line,load,temperature&life
OutputVoltageRippleandNoise 20MHzbandwidth;seeNote1
Peak-to-Peak 0 200 400 mV Fullload
RMS 36 70 mV Fullload
OperatingOutputCurrentRange 0 10 ASubjecttothermalderating
OutputDCCurrent-LimitInception 11.0 12.0 13.0 A Outputvoltage10%Low
OutputDCCurrent-LimitShutdownVoltage 15 V
Back-DriveCurrentLimitwhileEnabled 0.15 A Negativecurrentdrawnfromoutput
Back-DriveCurrentLimitwhileDisabled 2.5 mA Negativecurrentdrawnfromoutput
MaximumOutputCapacitance 400 µF Voutnominalatfullload(resistiveload)
OutputVoltageduringLoadCurrentTransient
StepChangeinOutputCurrent(0.1A/µs) 1300 mV 50%to75%to50%Ioutmax
SettlingTime 80 µs Towithin1%Voutnom
OutputVoltageTrimRange -20 10 % AcrossPins8&4;CommonFigures3-5
OutputVoltageRemoteSenseRange 10 % AcrossPins8&4
OutputOver-VoltageProtection 28.1 29.3 30.5 V Overfulltemprange
EFFICIENCY
100%Load 88 % SeeFigure1forefficiencycurve
50%Load 92 % SeeFigure1forefficiencycurve
Note1:Outputisterminatedwith1µFceramicandcapacitor.Forapplicationsrequiringreducedoutputvoltagerippleandnoise,consultSynQor
applicationssupport(e-mail:support@synqor.com)
Product # IQ70xxxHPXxx Phone 1-888-567-9596 www.synqor.com Doc.# 005-0005255 Rev. B 5/6/10 Page 17
Technical Specification
Input:
Output:
Current:
Part No.:
Figure 1: Efficiency at nominal output voltage vs. load current for
minimum, nominal, and maximum input voltage at 25
°
C. Figure 2: Power dissipation at nominal output voltage vs. load current
for minimum, nominal, and maximum input voltage at 25
°
C.
Figure 3: Encased converter (without heatsink) max. output power derating vs.
ambient air temperature for airflow rates of 100 LFM through 400 LFM. Air flows
across the converter from input to output (nominal input voltage).
Figure 4: Encased converter (with 1/2 heatsink) max. output power derating vs.
ambient air temperature for airflow rates of 100 LFM through 400 LFM. Air flows
across the converter from input to output (nominal input voltage).
34 - 135 V
24 V
10 A
IQ70240HPx10
Figure 6: Output voltage response to step-change in input voltage
(500 V/ms). Load cap: 100
µ
F, electrolytic output capacitance.
Ch 1: Vout (2 V/div), Ch 2: Vin (50 V/div).
Figure 5: Output voltage response to step-change in load current (50%-75%-
50% of Iout(max); dI/dt = 0.1 A/
µ
s). Load cap: 1
µ
F ceramic capacitor. Ch 1: Vout
(2 V/div), Ch 2: Iout (2.5 A/div).
0
1
2
3
4
5
6
7
8
9
10
11
25 40 55 70 85
Ambient Air Temperature (°C)
Iout (A)
400 LFM (2.0 m/s)
300 LFM (1.5 m/s)
200 LFM (1.0 m/s)
100 LFM (0.5 m/s)
0
1
2
3
4
5
6
7
8
9
10
11
25 40 55 70 85
Ambient Air Temperature (°C)
Iout (A)
400 LFM (2.0 m/s)
300 LFM (1.5 m/s)
200 LFM (1.0 m/s)
100 LFM (0.5 m/s)
0
5
10
15
20
25
30
35
40
012345678910
Load Current (A)
Power Dissipation (W)
34 Vin
70 Vin
135 Vin
60
65
70
75
80
85
90
95
100
0 1 2 3 4 5 6 7 8 9 10
Load Current (A)
Efficiency (%)
34 Vin
70 Vin
135 Vin
34 - 135 V
24 V
10 A
IQ70240HPx10
Product # IQ70xxxHPXxx Phone 1-888-567-9596 www.synqor.com Doc.# 005-0005255 Rev. B 5/6/10 Page 18
Technical Specification
Input:
Output:
Current:
Part No.:
34 - 135 V
28 V
8.5 A
IQ70280HPx8F
IQ70280HPx8F ELECTRICAL CHARACTERISTICS (28 Vout)
Ta=25°C,airflowrate=300LFM,Vin=70Vdcunlessotherwisenoted;fulloperatingtemperaturerangeis-40°Cto+100°Cbaseplate
temperaturewithappropriatepowerderating.Specificationssubjecttochangewithoutnotice.
Parameter Min. Typ. Max. Units Notes & Conditions
INPUT CHARACTERISTICS
MaximumInputCurrent 10.4 A Vinmin;trim-up;incurrentlimit(typ)
No-LoadInputCurrent 45 60 mA
DisabledInputCurrent 2 3 mA
ResponsetoInputTransient 2 V 500V/ms,seeFigure6
InputTerminalRippleCurrent 420 mA RMS
RecommendedInputFuse 15 A Fastactingexternalfuserecommended
OUTPUT CHARACTERISTICS
OutputVoltageSetPoint 27.72 28 28.28 V
OutputVoltageRegulation
OverLine ±0.1 ±0.3 %
OverLoad ±0.1 ±0.3 %
OverTemperature -420 420 mV
TotalOutputVoltageRange 27.30 28.70 V Oversample,line,load,temperature&life
OutputVoltageRippleandNoise 20MHzbandwidth;seeNote1
Peak-to-Peak 0 230 460 mV Fullload
RMS 40 80 mV Fullload
OperatingOutputCurrentRange 0 8.5 ASubjecttothermalderating
OutputDCCurrent-LimitInception 9.35 10.2 11.1 A Outputvoltage10%Low
OutputDCCurrent-LimitShutdownVoltage 17 V
Back-DriveCurrentLimitwhileEnabled 0.17 A Negativecurrentdrawnfromoutput
Back-DriveCurrentLimitwhileDisabled 3 mA Negativecurrentdrawnfromoutput
MaximumOutputCapacitance 250 µF Voutnominalatfullload(resistiveload)
OutputVoltageduringLoadCurrentTransient
StepChangeinOutputCurrent(0.1A/µs) 1500 mV 50%to75%to50%Ioutmax
SettlingTime 80 µs Towithin1%Voutnom
OutputVoltageTrimRange -20 10 % AcrossPins8&4;CommonFigures3-5
OutputVoltageRemoteSenseRange 10 % AcrossPins8&4
OutputOver-VoltageProtection 32.8 34.2 35.6 V Overfulltemprange
EFFICIENCY
100%Load 89 % SeeFigure1forefficiencycurve
50%Load 92 % SeeFigure1forefficiencycurve
Note1:Outputisterminatedwith1µFceramicandcapacitor.Forapplicationsrequiringreducedoutputvoltagerippleandnoise,consultSynQor
applicationssupport(e-mail:support@synqor.com)
Product # IQ70xxxHPXxx Phone 1-888-567-9596 www.synqor.com Doc.# 005-0005255 Rev. B 5/6/10 Page 19
Technical Specification
Input:
Output:
Current:
Part No.:
Figure 1: Efficiency at nominal output voltage vs. load current for
minimum, nominal, and maximum input voltage at 25
°
C. Figure 2: Power dissipation at nominal output voltage vs. load current
for minimum, nominal, and maximum input voltage at 25
°
C.
Figure 3: Encased converter (without heatsink) max. output power derating vs.
ambient air temperature for airflow rates of 100 LFM through 400 LFM. Air flows
across the converter from input to output (nominal input voltage).
Figure 4: Encased converter (with 1/2 heatsink) max. output power derating vs.
ambient air temperature for airflow rates of 100 LFM through 400 LFM. Air flows
across the converter from input to output (nominal input voltage).
Figure 6: Output voltage response to step-change in input voltage
(500 V/ms). Load cap: 100
µ
F, electrolytic output capacitance.
Ch 1: Vout (2 V/div), Ch 2: Vin (50 V/div).
Figure 5: Output voltage response to step-change in load current (50%-75%-
50% of Iout(max); dI/dt = 0.1 A/µ
s
). Load cap: 1
µ
F ceramic capacitor. Ch 1: Vout
(2 V/div), Ch 2: Iout (2.5 A/div).
0
1
2
3
4
5
6
7
8
9
25 40 55 70 85
Ambient Air Temperature (°C)
Iout (A)
400 LFM (2.0 m/s)
300 LFM (1.5 m/s)
200 LFM (1.0 m/s)
100 LFM (0.5 m/s)
0
1
2
3
4
5
6
7
8
9
25 40 55 70 85
Ambient Air Temperature (°C)
Iout (A)
400 LFM (2.0 m/s)
300 LFM (1.5 m/s)
200 LFM (1.0 m/s)
100 LFM (0.5 m/s)
0
5
10
15
20
25
30
35
0.00 0.85 1.70 2.55 3.40 4.25 5.10 5.95 6.80 7.65 8.50
Load Current (A)
Power Dissipation (W)
34 Vin
70 Vin
135 Vin
60
65
70
75
80
85
90
95
100
0.00 0.85 1.70 2.55 3.40 4.25 5.10 5.95 6.80 7.65 8.50
Load Current (A)
Efficiency (%)
34 Vin
70 Vin
135 Vin
34 - 135 V
28 V
8.5 A
IQ70280HPx8F
34 - 135 V
28 V
8.5 A
IQ70280HPx8F
Product # IQ70xxxHPXxx Phone 1-888-567-9596 www.synqor.com Doc.# 005-0005255 Rev. B 5/6/10 Page 20
Technical Specification
Input:
Output:
Current:
Part No.:
34 - 135 V
40 V
6.0 A
IQ70400HPx06
IQ70400HPx06 ELECTRICAL CHARACTERISTICS (40 Vout)
Ta=25°C,airflowrate=300LFM,Vin=70Vdcunlessotherwisenoted;fulloperatingtemperaturerangeis-40°Cto+100°Cbaseplate
temperaturewithappropriatepowerderating.Specificationssubjecttochangewithoutnotice.
Parameter Min. Typ. Max. Units Notes & Conditions
INPUT CHARACTERISTICS
MaximumInputCurrent 10.5 A Vinmin;trim-up;incurrentlimit(typ)
No-LoadInputCurrent 50 60 mA
DisabledInputCurrent 2 3 mA
ResponsetoInputTransient 2.6 V 500V/ms,seeFigure6
InputTerminalRippleCurrent 440 mA RMS
RecommendedInputFuse 15 A Fastactingexternalfuserecommended
OUTPUT CHARACTERISTICS
OutputVoltageSetPoint 39.6 40 40.4 V
OutputVoltageRegulation
OverLine ±0.1 ±0.3 %
OverLoad ±0.1 ±0.3 %
OverTemperature -600 600 mV
TotalOutputVoltageRange 39.00 41.00 V Oversample,line,load,temperature&life
OutputVoltageRippleandNoise 20MHzbandwidth;seeNote1
Peak-to-Peak 0 200 400 mV Fullload
RMS 30 60 mV Fullload
OperatingOutputCurrentRange 0 6 ASubjecttothermalderating
OutputDCCurrent-LimitInception 6.6 7.2 7.8 A Outputvoltage10%Low
OutputDCCurrent-LimitShutdownVoltage 23 V
Back-DriveCurrentLimitwhileEnabled 0.13 A Negativecurrentdrawnfromoutput
Back-DriveCurrentLimitwhileDisabled 4 mA Negativecurrentdrawnfromoutput
MaximumOutputCapacitance 150 µF Voutnominalatfullload(resistiveload)
OutputVoltageduringLoadCurrentTransient
StepChangeinOutputCurrent(0.1A/µs) 2250 mV 50%to75%to50%Ioutmax
SettlingTime 80 µs Towithin1%Voutnom
OutputVoltageTrimRange -20 10 % AcrossPins8&4;CommonFigures3-5
OutputVoltageRemoteSenseRange 10 % AcrossPins8&4
OutputOver-VoltageProtection 46.8 48.8 50.8 V Overfulltemprange
EFFICIENCY
100%Load 89 % SeeFigure1forefficiencycurve
50%Load 92 % SeeFigure1forefficiencycurve
Note1:Outputisterminatedwith1µFceramicandcapacitor.Forapplicationsrequiringreducedoutputvoltagerippleandnoise,consultSynQor
applicationssupport(e-mail:support@synqor.com)
Product # IQ70xxxHPXxx Phone 1-888-567-9596 www.synqor.com Doc.# 005-0005255 Rev. B 5/6/10 Page 21
Technical Specification
Input:
Output:
Current:
Part No.:
Figure 1: Efficiency at nominal output voltage vs. load current for
minimum, nominal, and maximum input voltage at 25
°
C. Figure 2: Power dissipation at nominal output voltage vs. load current
for minimum, nominal, and maximum input voltage at 25
°
C.
Figure 3: Encased converter (without heatsink) max. output power derating vs.
ambient air temperature for airflow rates of 100 LFM through 400 LFM. Air flows
across the converter from input to output (nominal input voltage).
Figure 4: Encased converter (with 1/2 heatsink) max. output power derating vs.
ambient air temperature for airflow rates of 100 LFM through 400 LFM. Air flows
across the converter from input to output (nominal input voltage).
Figure 6: Output voltage response to step-change in input voltage
(500 V/ms). Load cap: 100
µ
F, electrolytic output capacitance.
Ch 1: Vout (2 V/div), Ch 2: Vin (50 V/div).
Figure 5: Output voltage response to step-change in load current (50%-75%-
50% of Iout(max); dI/dt = 0.1 A/µ
s
). Load cap: 1
µ
F ceramic capacitor. Ch 1: Vout
(2 V/div), Ch 2: Iout (2.5 A/div).
0.0
1.0
2.0
3.0
4.0
5.0
6.0
7.0
25 40 55 70 85
Ambient Air Temperature (°C)
Iout (A)
400 LFM (2.0 m/s)
300 LFM (1.5 m/s)
200 LFM (1.0 m/s)
100 LFM (0.5 m/s)
0.0
1.0
2.0
3.0
4.0
5.0
6.0
7.0
25 40 55 70 85
Ambient Air Temperature (°C)
Iout (A)
400 LFM (2.0 m/s)
300 LFM (1.5 m/s)
200 LFM (1.0 m/s)
100 LFM (0.5 m/s)
0
5
10
15
20
25
30
35
0.0 0.5 1.0 1.5 2.0 2.5 3.0 3.5 4.0 4.5 5.0 5.5 6.0
Load Current (A)
Power Dissipation (W)
34 Vin
70 Vin
135 Vin
60
65
70
75
80
85
90
95
100
0.0 0.5 1.0 1.5 2.0 2.5 3.0 3.5 4.0 4.5 5.0 5.5 6.0
Load Current (A)
Efficiency (%)
34 Vin
70 Vin
135 Vin
34 - 135 V
40 V
6.0 A
IQ70400HPx06
34 - 135 V
40 V
6.0 A
IQ70400HPx06
Product # IQ70xxxHPXxx Phone 1-888-567-9596 www.synqor.com Doc.# 005-0005255 Rev. B 5/6/10 Page 22
Technical Specification
Input:
Output:
Current:
Part No.:
34 - 135 V
48 V
5.0 A
IQ70480HPx05
IQ70480HPx05 ELECTRICAL CHARACTERISTICS (48 Vout)
Ta=25°C,airflowrate=300LFM,Vin=70Vdcunlessotherwisenoted;fulloperatingtemperaturerangeis-40°Cto+100°Cbaseplate
temperaturewithappropriatepowerderating.Specificationssubjecttochangewithoutnotice.
Parameter Min. Typ. Max. Units Notes & Conditions
INPUT CHARACTERISTICS
MaximumInputCurrent 10.4 A Vinmin;trim-up;incurrentlimit(typ)
No-LoadInputCurrent 55 70 mA
DisabledInputCurrent 2 3 mA
ResponsetoInputTransient 3.2 V 500V/ms,seeFigure6
InputTerminalRippleCurrent 490 mA RMS
RecommendedInputFuse 15 A Fastactingexternalfuserecommended
OUTPUT CHARACTERISTICS
OutputVoltageSetPoint 47.52 48 48.48 V
OutputVoltageRegulation
OverLine ±0.1 ±0.3 %
OverLoad ±0.1 ±0.3 %
OverTemperature -720 720 mV
TotalOutputVoltageRange 46.80 49.20 V Oversample,line,load,temperature&life
OutputVoltageRippleandNoise 20MHzbandwidth;seeNote1
Peak-to-Peak 0 180 360 mV Fullload
RMS 30 60 mV Fullload
OperatingOutputCurrentRange 0 5 ASubjecttothermalderating
OutputDCCurrent-LimitInception 5.5 6.0 6.5 A Outputvoltage10%Low
OutputDCCurrent-LimitShutdownVoltage 27 V
Back-DriveCurrentLimitwhileEnabled 0.1 A Negativecurrentdrawnfromoutput
Back-DriveCurrentLimitwhileDisabled 5 mA Negativecurrentdrawnfromoutput
MaximumOutputCapacitance 100 µF Voutnominalatfullload(resistiveload)
OutputVoltageduringLoadCurrentTransient
StepChangeinOutputCurrent(0.1A/µs) 2700 mV 50%to75%to50%Ioutmax
SettlingTime 80 µs Towithin1%Voutnom
OutputVoltageTrimRange -20 10 % AcrossPins8&4;CommonFigures3-5
OutputVoltageRemoteSenseRange 10 % AcrossPins8&4
OutputOver-VoltageProtection 56.2 58.6 61.0 V Overfulltemprange
EFFICIENCY
100%Load 90 % SeeFigure1forefficiencycurve
50%Load 92 % SeeFigure1forefficiencycurve
Note1:Outputisterminatedwith1µFceramicandcapacitor.Forapplicationsrequiringreducedoutputvoltagerippleandnoise,consultSynQor
applicationssupport(e-mail:support@synqor.com)
Product # IQ70xxxHPXxx Phone 1-888-567-9596 www.synqor.com Doc.# 005-0005255 Rev. B 5/6/10 Page 23
Technical Specification
Input:
Output:
Current:
Part No.:
Figure 1: Efficiency at nominal output voltage vs. load current for
minimum, nominal, and maximum input voltage at 25
°
C. Figure 2: Power dissipation at nominal output voltage vs. load current
for minimum, nominal, and maximum input voltage at 25
°
C.
Figure 3: Encased converter (without heatsink) max. output power derating vs.
ambient air temperature for airflow rates of 100 LFM through 400 LFM. Air flows
across the converter from input to output (nominal input voltage).
Figure 4: Encased converter (with 1/2 heatsink) max. output power derating vs.
ambient air temperature for airflow rates of 100 LFM through 400 LFM. Air flows
across the converter from input to output (nominal input voltage).
Figure 6: Output voltage response to step-change in input voltage
(500 V/ms). Load cap: 100
µ
F, electrolytic output capacitance.
Ch 1: Vout (5 V/div), Ch 2: Vin (50 V/div).
Figure 5: Output voltage response to step-change in load current (50%-75%-
50% of Iout(max); dI/dt = 0.1 A/µ
s
). Load cap: 1
µ
F ceramic capacitor. Ch 1: Vout
(2 V/div), Ch 2: Iout (2.5 A/div).
0
5
10
15
20
25
30
35
0.0 0.5 1.0 1.5 2.0 2.5 3.0 3.5 4.0 4.5 5.0
Load Current (A)
Power Dissipation (W)
34 Vin
70 Vin
135 Vin
60
65
70
75
80
85
90
95
100
0.0 0.5 1.0 1.5 2.0 2.5 3.0 3.5 4.0 4.5 5.0
Load Current (A)
Efficiency (%)
34 Vin
70 Vin
135 Vin
0.0
0.5
1.0
1.5
2.0
2.5
3.0
3.5
4.0
4.5
5.0
5.5
6.0
25 40 55 70 85
Ambient Air Temperature (°C)
Iout (A)
400 LFM (2.0 m/s)
300 LFM (1.5 m/s)
200 LFM (1.0 m/s)
100 LFM (0.5 m/s) 0.0
0.5
1.0
1.5
2.0
2.5
3.0
3.5
4.0
4.5
5.0
5.5
6.0
25 40 55 70 85
Ambient Air Temperature (°C)
Iout (A)
400 LFM (2.0 m/s)
300 LFM (1.5 m/s)
200 LFM (1.0 m/s)
100 LFM (0.5 m/s)
34 - 135 V
48 V
5.0 A
IQ70480HPx05
34 - 135 V
48 V
5.0 A
IQ70480HPx05
Technical
Specification
IQ70-HP Family
Product # IQ70xxxHPXxx Phone 1-888-567-9596 www.synqor.com Doc.# 005-0005255 Rev. B 5/6/10 Page 24
BASICOPERATIONANDFEATURES
This converter series uses a two-stage power conversion
topology. The first stage is a buck-converter that keeps the
output voltage constant over variations in line, load, and
temperature. The second stage uses a transformer to provide
the functions of input/output isolation and voltage step-up or
step-down to achieve the output voltage required.
Both the first stage and the second stage switch at a fixed
frequency for predictable EMI performance. Rectification of
the transformer’s output is accomplished with synchronous
rectifiers. These devices, which are MOSFETs with a very low
on-state resistance, dissipate far less energy than Schottky
diodes. This is the primary reason that the converter has such
high efficiency, even at very low output voltages and very high
output currents.
These converters are offered totally encased to withstand harsh
environmentsandthermallydemandingapplications.Dissipation
throughout the converter is so low that it does not require a
heatsink for operation in many applications; however, adding
a heatsink provides improved thermal derating performance in
extreme si tuations.
This series of converters use the industry standard footprint and
pin-out configuration.
CONTROLFEATURES
REMOTE ON/OFF (Pin 2):TheON/OFFinput,Pin2,permits
the user to control when the converter is on or off. This input
is referenced to the return terminal of the input bus, Vin(-).
TheON/OFFsignalisactivelow(meaningthatalowturnsthe
converteron).FigureAdetailsfourpossiblecircuitsfordriving
theON/OFFpin.FigureBisadetailedlookoftheinternalON/
OFFcircuitry.
REMOTE SENSE(+) (Pins 7 and 5): The SENSE(+) inputs
correct for voltage drops along the conductors that connect the
converter’soutputpinstotheload.
Pin 7 should be connected to Vout(+) and Pin 5 should be
connectedtoVout(-)atthepointontheboardwhereregulation
is desired. A remote connection at the load can adjust for a
voltage drop only as large as that specified in this datasheet,
that is
[Vout(+)-Vout(-)]–[Vsense(+)-Vsense(-)] <
SenseRange%xVout
Pins 7 and 5 must be connected for proper regulation of
the output voltage. If these connections are not made, the
converter will deliver an output voltage that is slightly higher
than its specified value.
Note: the output over-voltage protection circuit senses the
voltage across the output (pins 8 and 4) to determine when
it should trigger, not the voltage across the converter’s sense
leads(pins7and5).Therefore,theresistivedropontheboard
should be small enough so that output OVP does not trigger,
even during load transients.
Open Collector Enable Circuit
Remote Enable Circuit
Direct Logic Drive
Negative Logic
(Permanently Enabled)
ON/OFF
Vin(_)
ON/OFF
ON/OFF
Vin(_)
ON/OFF
5V
TTL/
CMOS
Vin(_)
Vin(_)
Figure A: Various circuits for driving the ON/OFF pin.
Figure B: Internal ON/OFF pin circuitry
TTL
5V
50k
50k
ON/OFF
Vin(_)
100pF
Technical
Specification
IQ70-HP Family
Product # IQ70xxxHPXxx Phone 1-888-567-9596 www.synqor.com Doc.# 005-0005255 Rev. B 5/6/10 Page 25
OUTPUT VOLTAGE TRIM (Pin 6):TheTRIMinputpermitsthe
usertoadjusttheoutputvoltageacrossthesenseleadsupor
down according to the trim range specifications.
To decrease the output voltage, the user should connect a
resistorbetweenPin6andPin5(SENSE(-)input).Foradesired
decrease of the nominal output voltage, the value of the resistor
should be
Rtrim-down =
(
511
)
-10.22 (kW)
%
where
∆% =
Vnominal–Vdesired
x100%
Vnominal
To increase the output voltage, the user should connect a
resistorbetweenPin6andPin7(SENSE(+)input).Foradesired
increase of the nominal output voltage, the value of the resistor
should be
Trim graphs show the relationship between the trim resistor
valueandRtrim-upandRtrim-down,showingthetotalrangethe
output voltage can be trimmed up or down.
Note:theTRIMfeaturedoesnotaffectthevoltageatwhichthe
output over-voltage protection circuit is triggered. Trimming the
output voltage too high may cause the over-voltage protection
circuit to engage, particularly during transients.
It is not necessary for the user to add capacitance at the Trim
pin. The node is internally bypassed to eliminate noise.
Total DC Variation of VOUT:Fortheconverter to meet itsfull
specifications, the maximum variation of the dc value of VOUT,
due to both trimming and remote load voltage drops, should not
be greater than that specified for the output voltage trim range.
PROTECTIONFEATURES
Input Under-Voltage Lockout: The converter is designed
to turn off when the input voltage is too low, helping avoid an
input system instability problem, described in more detail in
the application note titled
Input System Instability
” on our
website. The lockout circuitry is a comparator with dc hysteresis.
When the input voltage is rising, it must exceed the typical Turn-
On Voltage Threshold value (listed on the specifications page)
before the converter will turn on. Once the converter is on,
the input voltage must fall below the typical Turn-Off Voltage
Threshold value before the converter will turn off.
Output Current Limit: The maximum current limit remains
constant as the output voltage drops. However, once the
impedance of the load across the output is small enough to make
theoutputvoltagedropbelowthespecifiedOutputDCCurrent-
LimitShutdownVoltage,theconverterturnsoff.
Theconverterthenentersa“hiccupmode”whereitrepeatedly
turnsonandoffata5Hz(nominal)frequencywitha5%duty
cycle until the short circuit condition is removed. This prevents
excessive heating of the converter or the load board.
Output Over-Voltage Limit:Ifthevoltageacrosstheoutput
pinsexceedstheOutputOver-VoltageProtectionthreshold,the
converter will immediately stop switching. This prevents damage
totheloadcircuitdueto1)excessiveseriesresistanceinoutput
current path from converter output pins to sense point, 2) a
releaseofashort-circuitcondition,or3)areleaseofacurrent
limit condition. Load capacitance determines exactly how high
theoutputvoltagewillriseinresponsetotheseconditions.After
200mstheconverterwillautomaticallyrestart.
Over-Temperature Shutdown: A temperature sensor on
the converter senses the average temperature of the module.
The thermal shutdown circuit is designed to turn the converter
off when the temperature at the sensed location reaches the
Over-Temperature Shutdown value. It will allow the converter
to turn on again when the temperature of the sensed location
fallsbytheamountoftheOver-TemperatureShutdownRestart
Hysteresis value.
Rtrim-up
(k
W)
where Vout=NominalOutputVoltage
511
_ 10.22
5.11VOUTx
(100+
%)
1.225%%
)
=
(
_
Technical
Specification
IQ70-HP Family
Product # IQ70xxxHPXxx Phone 1-888-567-9596 www.synqor.com Doc.# 005-0005255 Rev. B 5/6/10 Page 26
APPLICATIONCONSIDERATIONS
Figure C: Typical application circuit (negative logic unit, permanently enabled).
Figure D: Internal Input Filter Diagram (component values
listed on the specifications page).
Vin External
Input
Filter Trim
Vin(+)
Iload
Cload
Vout(+)
Rtrim-up
or
Rtrim-down
Vsense(+)
ON/OFF
Vin(_)Vout(_)
Vsense(_)
Electrolytic
Capacitor
Input System Instability: This
condition can occur because
any dc-dc converter appears incrementally as a negative
resistanceload.Adetailedapplicationnotetitled“InputSystem
Instability”isavailableontheSynQorwebsite which provides
an understanding of why this instability arises, and shows the
preferred solution for correcting it.
Application Circuits:FigureCprovidesatypicalcircuitdiagram
which details the input filtering and voltage trimming.
Input Filtering and External Capacitance:
FigureD
provides
a diagram showing the internal input filter components. This filter
dramatically reduces input terminal ripple current, which otherwise
could exceed the rating of an external electrolytic input capacitor.
The recommended external input capacitance is specified in the
Input Characteristics section on the
Electrical Characteristics
page.
Moredetailedinformationisavailableintheapplicationnote
titled
EMICharacteristics
”onthe
SynQorwebsite.
C
L
Vin(+)
Vin(_)
Technical
Specification
IQ70-HP Family
Product # IQ70xxxHPXxx Phone 1-888-567-9596 www.synqor.com Doc.# 005-0005255 Rev. B 5/6/10 Page 27
Startup Inhibit Period:TheStartupInhibitPeriodensuresthat
theconverterwillremainoffforapproximately200mswhenitis
shut down for any reason. When an output short is present, this
generates a 5 Hz “hiccup mode,” which prevents the converter
from overheating. In all, there are seven ways that the converter
canbeshutdown,initiatingaStartupInhibitPeriod:
• InputUnder-VoltageLockout
• InputOver-VoltageShutdown
• OutputOver-VoltageProtection
• OverTemperatureShutdown
• CurrentLimit
• ShortCircuitProtection
• TurnedoffbytheON/OFFinput
FigureEshowsthreeturn-onscenarios,whereaStartupInhibit
Period is initiated at t0, t1, and t2:
Beforetimet0,whentheinputvoltageisbelowtheUVLthreshold,
theunitisdisabledbytheInputUnder-VoltageLockoutfeature.
WhentheinputvoltagerisesabovetheUVLthreshold,theInput
Under-VoltageLockoutisreleased,andaStartupInhibitPeriodis
initiated.Attheendofthisdelay,theON/OFFpinisevaluated,
and since it is active, the unit turns on.
Attimet1,theunitisdisabledbytheON/OFFpin,anditcannot
beenabledagainuntiltheStartupInhibitPeriodhaselapsed.
When the ON/OFF pin goes high after t2, the Startup Inhibit
Period has elapsed, and the output turns on within the typical
Turn-OnTime.
Thermal Considerations: The maximum operating base-plate
temperature, TB,is100ºC.Aslongastheuser’sthermalsystem
keeps TB <100ºC,theconvertercandeliveritsfullratedpower.
Apowerderatingcurvecanbecalculatedforanyheatsinkthatis
attached to the base-plate of the converter. It is only necessary
todeterminethethermalresistance,RTHBA, of the chosen heatsink
between the base-plate and the ambient air for a given airflow
rate. This information is usually available from the heatsink
vendor. The following formula can the be used to determine the
maximum power the converter can dissipate for a given thermal
conditionifitsbase-plateistobenohigherthan100ºC.
Pmax = 100 ºC-TA
dissRTHBA
Thisvalueofpowerdissipationcanthenbeusedinconjunction
withthedatashowninFigure2todeterminethemaximumload
current(andpower)that the converter candeliverinthe given
thermal condition.
Forconvenience,powerderatingcurvesforanencasedconverter
without a heatsink and with a typical heatsink are provided for
each output voltage.
Figure E: Startup Inhibit Period (turn-on time not to scale)
Under-Voltage
LockoutTurn-
OnThreshold
ON/OFF
(neglogic)
Vout
Vin
200ms 200ms
200ms
(typicalstart-up
inhibitperiod)
t0t1t2t
9ms (typical
turnontime)
ON ON ON
OFF OFF
Technical
Specification
IQ70-HP Family
Product # IQ70xxxHPXxx Phone 1-888-567-9596 www.synqor.com Doc.# 005-0005255 Rev. B 5/6/10 Page 28
PART NUMBERING SYSTEM
The part numbering system for SynQor’s dc-dc converters
follows the format shown in the example below.
Thefirst12characterscomprisethebase partnumberand
the last 3 characters indicate available options. The “-G”
suffixindicates6/6RoHScompliance.
Application Notes
Avarietyofapplicationnotesandtechnicalwhitepaperscan
be downloaded in pdf format from our website.
RoHS Compliance:TheEUledRoHS(RestrictionofHazardous
Substances)DirectivebanstheuseofLead,Cadmium,Hexavalent
Chromium, Mercury, Polybrominated Biphenyls (PBB), and
PolybrominatedDiphenylEther(PBDE)inElectricalandElectronic
Equipment. This SynQor product is 6/6 RoHS compliant. For
more information please refer to SynQor’s RoHS addendum
available at our RoHS Compliance / Lead Free Initiative web
page or e-mail us at
rohs@synqor.com
.
ORDERING INFORMATION
The tables below show the valid model numbers and ordering
options for converters in this product family. When ordering
SynQorconverters,pleaseensurethatyouusethecomplete
15 character part number consisting of the 12 character
base part number and the additional characters for options.
Add“-G”tothemodelnumberfor6/6RoHScompliance.
The following options must be included in place of the
w x y z
spaces in the model numbers listed above.
Not all combinations make valid part numbers, please contact
SynQorforavailability. SeetheProduct Summarywebpage for
more options.
PATENTS
SynQorholdsthefollowingpatents,oneormoreofwhich
mightapplytothisproduct:
5,999,417 6,222,742 6,545,890 6,577,109
6,594,159 6,731,520 6,894,468 6,896,526
6,927,987 7,050,309 7,072,190 7,085,146
7,119,524 7,269,034 7,272,021 7,272,023
Warranty
SynQoroffersatwo(2)yearlimitedwarranty.Completewarranty
information is listed on our website or is available upon request from
SynQor.
InformationfurnishedbySynQorisbelievedtobeaccurateandreliable.
However,noresponsibilityisassumedbySynQorforitsuse,norforany
infringements of patents or other rights of third parties which may result
fromitsuse.Nolicenseisgrantedbyimplicationorotherwiseunderany
patentorpatentrightsofSynQor.
Product Family
Package Size
Performance Level
Thermal Design
Output Current
6/6 RoHS
Options (see
Ordering Information)
Input Voltage
Output Voltage
Contact SynQor for further information:
Phone: 978-849-0600
TollFree: 888-567-9596
Fax: 978-849-0602
E-mail: power@synqor.com
Web:
www.synqor.com
Address: 155SwansonRoad
Boxborough,MA01719
USA
IQ 70 480 H P x 05 N R S - G
Model Number Continuous Input Voltage Output Voltage Maximum
Output Current
IQ70018HP
w
60NRS 34 - 135 V 1.8 V 60 A
IQ70033HP
w
57NRS 34 - 135 V 3.3 V 57 A
IQ70050HP
w
44NRS 34 - 135 V 5.0 V 44 A
IQ70120HP
w
20NRS 34 - 135 V 12 V 20 A
IQ70150HP
w
16NRS 34 - 135 V 15 V 16 A
IQ70240HP
w
10NRS 34 - 135 V 24 V 10 A
IQ70280HP
w
8FNRS 34 - 135 V 28 V 8.5 A
IQ70400HP
w
06NRS 34 - 135 V 40 V 6.0 A
IQ70480HP
w
05NRS 34 - 135 V 48 V 5.0 A
Options Description: w x y z
Thermal Design Enable Logic Pin Style Feature Set
C - Encased with
Threaded Baseplate
D - Encased with
Non-Threaded Baseplate
N - Negative R - 0.180" S - Standard