Solid State Relays G3@-VD G3H/G3HD CSM_G3H_G3HD_DS_E_5_1 New Models with International Standards Added to G3H Series (-VD in model number). Same Profile as LY1 and LY2 Bi-power Relays * Certified by UL, CSA, and VDE (models numbers with a suffix of "-VD"). * Socket type, same size as LY Power Relays. * Operation indicator provided to confirm input (models numbers with "N" before the suffix). Refer to Safety Precautions for All Solid State Relays. Note: The socket is optional. Model Number Structure Model Number Legend G3H-@@@@@@-@ 2 3 4 5 6 7 1 1. 8 Basic Model Name G3H: Solid State Relay Rated Load Power Supply Voltage 2: 200 VAC 2. 6. 7. 3, 4. Rated Load Current 03: 5. 3A Terminal Type S: Plug-in terminals 8. Zero Cross Function Blank: Equipped with zero cross function L: Not equipped with zero cross function Operation Indicator Blank: Not equipped with operation indicator N: Equipped with operation indicator Certification VD: Certified by UL, CSA, and VDE standards G3HD-@@@@-@ 1 1. 2. 3. 4. 2 3 4 5 6 7 Basic Model Name G3H: Solid State Relay Load Power Supply Type D: DC Rated Load Power Supply Voltage X: 50 VDC Rated Load Current 03: 3A 5. 6. 7. Terminal Type S: Plug-in terminals Operation Indicator Blank: Not equipped with operation indicator N: Equipped with operation indicator Certification VD: Certified by UL, CSA, VDE 1 G3H/G3HD Ordering Information List of Models Isolation Zero cross function Photocoupler Yes Phototriac coupler No Indicator Yes Rated output load Rated input voltage 3 A at 100 to 240 VAC (See note 1.) Model 5 to 24 VDC G3H-203SN-VD 5 VDC G3H-203SLN-VD 12 VDC 24 VDC Photocoupler --- Photocoupler Yes Phototriac coupler No 3 A at 4 to 48 VDC (See note 2.) No 5 to 24 VDC 3 A at 100 to 240 VAC (See note 1.) G3HD-X03SN-VD 4 to 24 VDC G3H-203S-VD 5 VDC G3H-203SL-VD 12 VDC 24 VDC Photocoupler --- Photodiode array --- Note: 1. 2. 3. 4. Yes 3 A at 4 to 48 VDC (See note 2.) 4 to 24 VDC G3HD-X03S-VD 2.5 A at 24 to 240 VDC (See note 3.) 12 to 24 VDC G3HD-202SN-VD Product is labelled "240 VAC". Product is labelled "48 VDC". Product is labelled "240 VDC". When ordering, specify the rated input voltage. Accessories (Order Separately) Connecting Sockets Item PTF08A-E PT08 Connecting Front connecting Back connecting Mounting method/ Terminal type Track mounted screw terminals Solder terminals Hold-down clip PYC-A1 PYC-P PT08-0 PCB terminals PT08QN Wire-wrapping terminals Specifications Ratings (at an Ambient Temperature of 25C) Input Model Rated voltage Operating voltage Impedance Voltage level Must operate voltage G3H-203SN-VD 5 to 24 VDC 4 to 28 VDC 15 mA max. (See note 2.) 1 VDC min. 1 VDC min. 4 to 6 VDC 390 20% 4 VDC max. 12 VDC 9.6 to 14.4 VDC 900 20% 9.6 VDC max. 24 VDC 19.2 VDC max. G3H-203SLN-VD 5 VDC Must release voltage 4 VDC max. 19.2 to 28.8 VDC 2 k20% G3HD-X03SN-VD 5 to 24 VDC 4 to 28 VDC 1.5 k +20%/-10% (See note 1.) 4 VDC max. 1 VDC min. G3H-203S-VD 4 to 24 VDC 3 to 28 VDC 15 mA max. (See note 2.) 3 VDC max. 1 VDC min. G3H-203SL-VD 5 VDC 4 to 6 VDC 390 20% 4 VDC max. 1 VDC min. 12 VDC 9.6 to 14.4 VDC 900 20% 9.6 VDC max. 24 VDC 19.2 to 28.8 VDC 2 k20% 19.2 VDC max. 4 to 24 VDC 3 to 28 VDC 1.5 k +20%/-10% (See note 1.) 3 VDC max. 1 VDC min. 9.6 to 28.8 VDC 25 mA max. (at 24 VDC) (See note 2.) 1 VDC min. G3HD-X03S-VD G3HD-202SN-VD 12 to 24 VDC 9.6 VDC max. Note: 1. The input impedance is given for the maximum operating voltage. For details, refer to the Technical Guide for Solid State Relays. 2. With constant current input system. 2 G3H/G3HD Output Model Applicable load Rated load voltage G3H-203SN-VD G3H-203S-VD Load voltage range Load current Inrush current 100 to 240 VAC 75 to 264 VAC 0.1 to 3 A at 40C 45 A 60 Hz, 1 cycle G3HD-X03SN-VD G3HD-X03S-VD 4 to 48 VDC 3 to 52.8 VDC 0.1 to 3 A at 40C 18 A (10 ms) G3HD-202SN-VD 24 to 240 VDC 19.2 to 264 VDC 0.001 to 2.5 A at 40C 20 A (10 ms) G3H-203SLN-VD G3H-203SL-VD Characteristics Model G3H-203SN-VD/203S-VD G3H-203SLN-VD/203SL-VD G3HD-X03SN-VD/X03S-VD Operate time 1/2 cycle of load power source + 1 ms max. 1 ms max. Release time 1/2 cycle of load power source + 1 ms max. 0.5 ms max. G3HD-202SN-VD 5 ms max. 2 ms max. 10 ms max. Output ON voltage drop 1.6 V (RMS) max. 3 V max. (output ON-resistance: 1.25 max.) Leakage current 5 mA max. (at 100 VAC); 2.5 mA max. (at 100 VAC); 10 mA max. (at 200 VAC) 5 mA max. (at 200 VAC) Insulation resistance 100 M min. (at 500 VDC) Dielectric strength 2,000 VAC, 50/60 Hz for 1 min Vibration resistance Destruction: 10 to 55 to 10 Hz, 0.75-mm single amplitude Shock resistance Destruction: 1,000 m/s2 Ambient temperature Operating: -30C to 80C (with no icing) Storage: -30C to 100C (with no icing) Ambient humidity 45% to 85% Certified standards G3H: UL508, CSA C22.2 No. 14, EN60947-4-3 G3HD: UL508, CSA C22.2 No. 14, EN60950-1 EMC Emission: EN55011 Group 1 Class B Immunity: EN61000-6-2 Weight Approx. 50 g 5 mA max. (at 50 VDC) 0.1 mA max. (at 200 VDC) 1,500 VAC, 50/60 Hz for 1 min Engineering Data One Cycle Surge Current: Non-repetitive G3H-203SN-VD/203S-VD/203SLN-VD/ 203SL-VD G3HD-X03SN-VD/X03S-VD G3HD-202SN-VD G3H-203SN-VD/203S-VD/203SLN-VD/ G3H-203SL-VD Non-repetitive (Keep the inrush current to half the rated value if it occurs repetitively.) G3H-203SN-VD, G3H-203S-VD G3H-203SLN-VD, G3H-203SL-VD G3HD-X03SN-VD, G3HD-X03S-VD 3 2.5 G3HD-X03SN-VD/X03S-VD G3HD-202SN-VD Inrush current (A) 4 Inrush current (A, Peak) Load current (A) Load Current vs. Ambient Temperature Characteristics 50 40 30 28 26 24 22 20 G3HD-202SN-VD 18 30 16 2 G3HD-X03SN-VD G3HD-X03S-VD 14 G3HD-202SN-VD 20 1.5 12 10 8 1 6 10 4 0 -30 -20 0 20 40 60 80 100 Ambient temperature (C) 0 10 30 50 100 200 500 1,000 5,000 Energized time (ms) 2 0 10 20 30 50 70 100 200 300 500 1,000 2,000 Energized time (ms) 3 G3H/G3HD Dimensions Note: All units are in millimeters unless otherwise indicated. (Bottom View) 28 max. 1 2 3 4(+) Load 5 (+) ( ) (-) 36.5 max. 42.5 max. 21.5 max. 6(-) Load Load power supply 7 Input - - 8 + + Input voltage Note: 1. The plus and minus symbols shown in the parentheses are for DC loads. 2. The coil has no polarity. 3. The load is possible to connect either + side or - side. Safety Precautions Precautions for Correct Use EMC Directive Compliance Please observe the following precautions to prevent failure to operate, malfunction, or undesirable effect on product performance. 1. AC-switching models comply with EMC Directives under the following conditions ("-VD" models only). Less than 3 m Load Connection Input The SSR for DC switching use can connect to a load regardless of the polarity of the positive and negative output terminals. Close Mounting of Multiple Relays If multiple Relays are mounted side by side, be aware that the outer wall of each SSR works as a heat sink. The SSR casing serves to dissipate heat. Install the Relays so that they are adequately ventilated. If poor ventilation is unavoidable, reduce the load current by half. Protective Terminal No overvoltage absorption element is built in. (The G3HD-202SN has a built-in varistor.) Be sure to connect an overvoltage absorption element when using the G3H or G3HD with an inductive load. G3H-VD Output Varistor: 470 V, 0.6 W Film capacitor: 1 F, 250 VAC Varistor Film Capacitor * Connect a varistor between the output terminals. * Connect a film capacitor to the load power supply. * The input cable must be less than 3 m. 2. DC-switching models comply with EMC Directives under the following conditions ("-VD" models only). Less than 10 m Load Input G3HD-VD Output * The input cable must be less than 10 m. ALL DIMENSIONS SHOWN ARE IN MILLIMETERS. To convert millimeters into inches, multiply by 0.03937. To convert grams into ounces, multiply by 0.03527. In the interest of product improvement, specifications are subject to change without notice. 4 Read and Understand This Catalog Please read and understand this catalog before purchasing the products. Please consult your OMRON representative if you have any questions or comments. Warranty and Limitations of Liability WARRANTY OMRON's exclusive warranty is that the products are free from defects in materials and workmanship for a period of one year (or other period if specified) from date of sale by OMRON. OMRON MAKES NO WARRANTY OR REPRESENTATION, EXPRESS OR IMPLIED, REGARDING NON-INFRINGEMENT, MERCHANTABILITY, OR FITNESS FOR PARTICULAR PURPOSE OF THE PRODUCTS. ANY BUYER OR USER ACKNOWLEDGES THAT THE BUYER OR USER ALONE HAS DETERMINED THAT THE PRODUCTS WILL SUITABLY MEET THE REQUIREMENTS OF THEIR INTENDED USE. OMRON DISCLAIMS ALL OTHER WARRANTIES, EXPRESS OR IMPLIED. LIMITATIONS OF LIABILITY OMRON SHALL NOT BE RESPONSIBLE FOR SPECIAL, INDIRECT, OR CONSEQUENTIAL DAMAGES, LOSS OF PROFITS OR COMMERCIAL LOSS IN ANY WAY CONNECTED WITH THE PRODUCTS, WHETHER SUCH CLAIM IS BASED ON CONTRACT, WARRANTY, NEGLIGENCE, OR STRICT LIABILITY. In no event shall the responsibility of OMRON for any act exceed the individual price of the product on which liability is asserted. IN NO EVENT SHALL OMRON BE RESPONSIBLE FOR WARRANTY, REPAIR, OR OTHER CLAIMS REGARDING THE PRODUCTS UNLESS OMRON'S ANALYSIS CONFIRMS THAT THE PRODUCTS WERE PROPERLY HANDLED, STORED, INSTALLED, AND MAINTAINED AND NOT SUBJECT TO CONTAMINATION, ABUSE, MISUSE, OR INAPPROPRIATE MODIFICATION OR REPAIR. Application Considerations SUITABILITY FOR USE OMRON shall not be responsible for conformity with any standards, codes, or regulations that apply to the combination of products in the customer's application or use of the products. At the customer's request, OMRON will provide applicable third party certification documents identifying ratings and limitations of use that apply to the products. This information by itself is not sufficient for a complete determination of the suitability of the products in combination with the end product, machine, system, or other application or use. The following are some examples of applications for which particular attention must be given. This is not intended to be an exhaustive list of all possible uses of the products, nor is it intended to imply that the uses listed may be suitable for the products: * Outdoor use, uses involving potential chemical contamination or electrical interference, or conditions or uses not described in this catalog. * Nuclear energy control systems, combustion systems, railroad systems, aviation systems, medical equipment, amusement machines, vehicles, safety equipment, and installations subject to separate industry or government regulations. * Systems, machines, and equipment that could present a risk to life or property. Please know and observe all prohibitions of use applicable to the products. NEVER USE THE PRODUCTS FOR AN APPLICATION INVOLVING SERIOUS RISK TO LIFE OR PROPERTY WITHOUT ENSURING THAT THE SYSTEM AS A WHOLE HAS BEEN DESIGNED TO ADDRESS THE RISKS, AND THAT THE OMRON PRODUCTS ARE PROPERLY RATED AND INSTALLED FOR THE INTENDED USE WITHIN THE OVERALL EQUIPMENT OR SYSTEM. PROGRAMMABLE PRODUCTS OMRON shall not be responsible for the user's programming of a programmable product, or any consequence thereof. Disclaimers CHANGE IN SPECIFICATIONS Product specifications and accessories may be changed at any time based on improvements and other reasons. It is our practice to change model numbers when published ratings or features are changed, or when significant construction changes are made. However, some specifications of the products may be changed without any notice. When in doubt, special model numbers may be assigned to fix or establish key specifications for your application on your request. Please consult with your OMRON representative at any time to confirm actual specifications of purchased products. DIMENSIONS AND WEIGHTS Dimensions and weights are nominal and are not to be used for manufacturing purposes, even when tolerances are shown. PERFORMANCE DATA Performance data given in this catalog is provided as a guide for the user in determining suitability and does not constitute a warranty. It may represent the result of OMRON's test conditions, and the users must correlate it to actual application requirements. Actual performance is subject to the OMRON Warranty and Limitations of Liability. ERRORS AND OMISSIONS The information in this document has been carefully checked and is believed to be accurate; however, no responsibility is assumed for clerical, typographical, or proofreading errors, or omissions. 2011.4 In the interest of product improvement, specifications are subject to change without notice. OMRON Corporation Industrial Automation Company http://www.ia.omron.com/ (c)Copyright OMRON Corporation 2011 All Right Reserved.