Orion Fans
10557 Metric Drive
Dallas, TX 75243
800.323.2439
A division of Knight Electronics,
information and data are subject to
change without prior notifi cation.
Model No. Description Weight
AFM-01NC Air-fl ow switch, NC with mounting clip and clamp (for attaching to existing fan assembly) 6 g (0.2 oz)
AFM-01NO Air-fl ow monitor, NO with mounting clip and clamp (for attaching to existing fan assembly) 6 g (0.2 oz)
AFM-80NC Air-fl ow monitor, NC with 80 x 80mm (3.15”) plastic fi nger guard 20 g (0.7 oz)
AFM-80NO Air-fl ow monitor, NO with 80 x 80mm (3.15”) plastic fi nger guard 20 g (0.7 oz)
AFM-92NC Air-fl ow monitor, NC with 92 x 92mm (3.62”) plastic fi nger guard 20 g (0.7 oz)
AFM-92NO Air-fl ow monitor, NO with 92 x 92mm (3.62”) plastic fi nger guard 20 g (0.7 oz)
AFM-120NC Air-fl ow monitor, NC with 120 x 120mm (4.27”) plastic fi nger guard 31 g (1.1 oz)
AFM-120NO Air-fl ow monitor, NO with 120 x 120mm (4.27”) plastic fi nger guard 31 g (1.1 oz)
AFM Series Air Flow Monitor
The air-fl ow monitor provides a simple alternative to indicate positive or negative air fl
www.orionfans.com
Specifi cations
Contact Type: Reed/magnet contact
NC (Normally Closed): Contact open with air fl ow
NO (Normally Open): Contact closed with air fl ow
Switching Threshold of Air Flow Speed: >8.2 ft/s
(2.5 m/s)
Hysteresis: 3.3 ft/s (1m/s) - fi xed
Contact Resistance Incl. Wire: 370m (1214”)
Service Life: >100,000 cycles
Maximum Switching Capacity: 10W (resistive load)
Maximum Switching Voltage: NC - AC/DC 240V
NO - DC 60V
Maximum Switching Current: NC - DC 500mA
NO - DC 170mA
perpendicular to air fl ow
Operating Temperature: -20 to 50°C (-4 to 122°F)
Storage Temperature: -20 to 80°C (-4 to 176°F)
Housing: Plastic, UL 94HB, black
Dimensions: 34 x 17.5 x 7.5mm (1.3 x 0.7 x 0.3”)
Protection Type: NEMA 1 (IP 20)
Agency Approvals: CE
RoHS Compliant
Dimensions: mm (inch)
Wiring Example
+
−80 x 80
(3.15 x 3.15)
92 x 92 / 120 x 120
(3.62 x 3.62 / 4.72 x 4.72)
7.5 (0.3)
17.5
(0.7)
34 (1.3)
e.g signal
device
AFM-KIT
Kit includes air-fl ow switch (AFM-01NC), clip, three
plastic guards (80, 92 and 120mm), LED and
holder, buzzer, switch and wall-mount power supply.
Delivered with a complete 10-foot wire assembly.
ow of fans or blowers. When
properly installed and connected in series with an optical (i.e. LED) or audible signaling device, a bi-directional switch will
activate an electrical contact if the air fl ow of the fan falls below 8.2 ft/s, turning the signaling device on or off. The AFM
monitor can also be attached to an existing plastic grill or guard.
protective plastic grill
Mounting Position: Air-flow monitoring opening
Air-fl ow monitor integrated
in a protective plastic grill
Connection: 2 x single strand AWG26, length 500mm
(20”), tip of stranded wire stripped/tinned 5mm (0/20”)
NC version (black wires), NO version (blue wires)
Mounting: Attachment clamp and/or clip, or integrated in