786J Series www.murata-ps.com Surface Mount General Purpose Pulse Transformers n 1kVrms isolation n Industry standard pinout n UL 94 V-0 package materials n Low profile n Toroidal construction DESCRIPTION The 786J series is a comprehensive range of general purpose pulse transformers. Common applications include line coupling, matching or isolating. The devices can also be used in small isolated power supplies and also as commonmode chokes in filtering applications. For through hole variants please see 786 Series datasheet. H Vs H pF Vrms 58 150 350 850 2000 3650 10000 53 180 380 970 1890 3350 10000 65 160 500 850 1840 3300 10000 50 190 490 980 2000 3200 10000 65 190 500 1000 1700 3700 10000 4 6 10 15 20 28 56 4 6 10 15 20 28 56 4 6 10 15 20 28 56 4 6 10 15 20 28 56 4 6 10 15 20 28 56 0.19 0.20 0.25 0.29 0.47 0.69 0.93 0.11 0.17 0.27 0.37 0.65 0.71 0.71 0.41 0.49 0.65 0.76 0.99 1.61 2.30 0.30 0.65 1.07 1.13 1.70 2.80 3.83 1.21 3.64 6.86 11.9 16.0 37.7 52.5 8 14 22 35 49 78 121 12 19 32 47 72 116 167 4 9 13 20 29 50 72 7 12 20 35 47 64 72 3 5 7 10 16 20 19 0.17 0.25 0.34 0.45 0.60 0.84 1.30 0.18 0.24 0.34 0.46 0.66 1.20 1.80 0.18 0.25 0.34 0.46 0.60 0.85 1.23 0.20 0.25 0.36 0.48 0.63 0.88 1.33 0.17 0.24 0.34 0.45 0.60 0.92 1.45 Winding Configuration Isolation Voltage n Primary inductance to 10mH Max. Primary DC Resistance n 4 Configurations 1:1 1:1 1:1 1:1 1:1 1:1 1:1 1:1:1 1:1:1 1:1:1 1:1:1 1:1:1 1:1:1 1:1:1 2:1 2:1 2:1 2:1 2:1 2:1 2:1 1CT:1 1CT:1 1CT:1 1CT:1 1CT:1 1CT:1 1CT:1 1CT:1CT 1CT:1CT 1CT:1CT 1CT:1CT 1CT:1CT 1CT:1CT 1CT:1CT Typ. Interwinding Capacitance n RoHS compliant 78601/4JC 78601/3JC 78601/2JC 78601/8JC 78601/1JC 78601/16JC 78601/9JC 78602/4JC 78602/3JC 78602/2JC 78602/8JC 78602/1JC 78602/16JC 78602/9JC 78604/4JC 78604/3JC 78604/2JC 78604/8JC 78604/1JC 78604/16JC 78604/9JC 78613/4JC 78613/3JC 78613/2JC 78613/8JC 78613/1JC 78613/16JC 78613/9JC 78615/4JC 78615/3JC 78615/2JC 78615/8JC 78615/1JC 78615/16JC 78615/9JC Typ. Leakage Inductance n J-STD-020D reflow Turns Ratio Primary Min. Volt-time Product, Et FEATURES Order Code Min. Primary Inductance SELECTION GUIDE 1000 1 1000 2 1000 1 1000 3 1000 4 ORDER CODE DETAILS Order Code 786XX/XJC 786XX/XJC-R Package Type 6 Pin SM 6 Pin SM Packaging Type Tube Tape & Reel Quantity 50 500 ABSOLUTE MAXIMUM RATINGS Operating free air temperature range Storage temperature range -40C to 85C -60C to 125C SOLDERING INFORMATION1 Pin finish Max. peak reflow temperature Moisture sensitivity level2 Max. time above liquidous (217C) For full details go to www.murata-ps.com/rohs Matte tin 245C 1 100s All specifications typical at TA=25C 1 For further information, please visit www.murata-ps.com/rohs 2 Representative samples of the product were subjected to the conditioning described in IPC/JEDEC J-STD-020D and passed electrical testing, package coplanarity and visual inspection which revealed no external cracks or changes in package body flatness. www.murata-ps.com/support KMP_786JC_A03 Page 1 of 4 ) 786J Series Surface Mount General Purpose Pulse Transformers PACKAGE SPECIFICATIONS MECHANICAL DIMENSIONS 12.70 (0.5) 9.52 (0.375) Max. 9.52 (0.375) Max. 9.0 (0.354) 78601/1C XYYWW 78601/1JC XYYWW 6.35 (0.25) 0.30 (0.012) 0.20 (0.008) 10.16 (0.4) 2.54 (0.1) 0.63 (0.025) 0.53 (0.021) 5.08 (0.2) 0.63 (0.025) 0.53 (0.021) 0.90 (0.04) Unless otherwise stated all dimensions in mm (inches) 0.25 (0.01). All pins on a 2.54 (0.1) pitch and within 0.25 (0.01) of true position. Package Weight: 1.1g Typ. RECOMMENDED FOOTPRINT DETAILS 2.54 (0.10) 1.60 (0.06) 2.54 (0.10) 2.54 (0.10) O1.20 (0.05) +0.15 (0.006) -0.000 (0.00) 1.00 (0.04) 11.50 (0.45) Unless otherwise stated all dimensions in mm (inches) 0.25 (0.01). All pins on a 2.54 (0.1) pitch and within 0.25 (0.01) of true position. WINDING CONFIGURATION (TOP VIEW) 1 1 2* Pri 3 3 2 Sec 6 5* 4 1 2 3 Pri Sec 1 Sec 2 6 5 4 1 2 3 4 Pri Sec 6 5* 4 1 2 3 Pri Sec 6 5 4 * Pins only fitted on 786XX/XJC and 786XX/XJC-R variants. www.murata-ps.com/support KMP_786JC_A03 Page 2 of 4 786J Series Surface Mount General Purpose Pulse Transformers TAPE & REEL SPECIFICATIONS REEL OUTLINE DIMENSIONS 60 (2.36) Min. O382 (15.039) Min. 23.9-27.4 (0.94-1.08)* O 13.50 (0.53) 12.80 (0.50) Leader section 400 (15.7) Min. 100 (3.9) Min. 1.50 (0.059) Min. 30.4 (1.20) Max. Goods enclosure section 24.4 (0.96) 26.4 (1.04) Trailer section 160 (6.3) Min. Unless otherwise stated all dimensions in mm (inches) 0.25 (0.01). O 20.20 (0.80) Min. * Includes flange distortion at outer edge. Measured at hub. TAPE OUTLINE DIMENSIONS 11.50 (0.453) 4.00 (0.157) +0.004 +0.10 1.50 -0.00 (0.059 -0.000 ) 2.00 (0.079) XYYWW 78601/1JC +0.012 24.00 +0.30 -0.10 (0.945 -0.004 ) 1.75 (0.069) Cover tape 7.20 (0.283) 9.37 (0.369) 12.00 (0.472) 0.60 (0.024) Max. Direction of unreeling Unless otherwise stated all dimensions in mm (inches) 0.25 (0.01). www.murata-ps.com/support KMP_786JC_A03 Page 3 of 4 786J Series Surface Mount General Purpose Pulse Transformers TECHNICAL NOTES TUBE OUTLINE DIMENSIONS ISOLATION VOLTAGE 10.95 (0.43) 4.00 (0.16) 0.600.15 (0.0230.005) 12.95 (0.51) 5.50 (0.22) 3.80 (0.15) 15.70 (0.62) Tube length: 4652 (18.30.08). Tube quantity: 50. Tube material: Antistatic coated clear pvc. Unless otherwise stated all dimensions in mm (inches) 0.25 (0.01). Murata Power Solutions, Inc. 11 Cabot Boulevard, Mansfield, MA 02048-1151 U.S.A. ISO 9001 and 14001 REGISTERED `Hi Pot Test', `Flash Tested', `Withstand Voltage', `Proof Voltage', `Dielectric Withstand Voltage' & `Isolation Test Voltage' are all terms that relate to the same thing, a test voltage, applied for a specified time, across a component designed to provide electrical isolation, to verify the integrity of that isolation. All products in this series are 100% production tested at their stated isolation voltage. A question commonly asked is, "What is the continuous voltage that can be applied across the part in normal operation?" For a part holding no specific agency approvals both input and output should normally be maintained within SELV limits i.e. less than 42.4V peak, or 60VDC. The isolation test voltage represents a measure of immunity to transient voltages and the part should never be used as an element of a safety isolation system. The part could be expected to function correctly with several hundred volts offset applied continuously across the isolation barrier; but then the circuitry on both sides of the barrier must be regarded as operating at an unsafe voltage and further isolation/insulation systems must form a barrier between these circuits and any user-accessible circuitry according to safety standard requirements. REPEATED HIGH-VOLTAGE ISOLATION TESTING It is well known that repeated high-voltage isolation testing of a barrier component can actually degrade isolation capability, to a lesser or greater degree depending on materials, construction and environment. This series has toroidal isolation transformers, with no additional insulation between primary and secondary windings of enameled wire. While parts can be expected to withstand several times the stated test voltage, the isolation capability does depend on the wire insulation. Any material, including this enamel (typically polyurethane) is susceptible to eventual chemical degradation when subject to very high applied voltages thus implying that the number of tests should be strictly limited. We therefore strongly advise against repeated high voltage isolation testing, but if it is absolutely required, that the voltage be reduced by 20% from specified test voltage. This consideration equally applies to agency recognized parts rated for better than functional isolation where the wire enamel insulation is always supplemented by a further insulation system of physical spacing or barriers. Murata Power Solutions, Inc. makes no representation that the use of its products in the circuits described herein, or the use of other technical information contained herein, will not infringe upon existing or future patent rights. The descriptions contained herein do not imply the granting of licenses to make, use, or sell equipment constructed in accordance therewith. Specifications are subject to change without notice. (c) 2012 Murata Power Solutions, Inc. www.murata-ps.com/support KMP_786JC_A03 Page 4 of 4