TN-1500 1500W True Sine Wave DC-AC Inverter with Solar Charger series Features : True sine wave output (THD<3%) High surge power up to 3000W U.P.S. mode and energy saving mode (selectable) High efficiency up to 91% Power ON-OFF switch Standby saving mode can be selectable Front panel indicator for operation status Thermostatically controlled cooling fan Protections: Bat. low alarm / Bat. low shutdown / Over voltage / Over temp. / Output short / Input polarity reverse / Overload / AC circuit breaker Application : Home appliance, power tools, office and portable equipment, vehicle and yacht ...etc. Built-in solar / AC charger Optional monitoring software E13 2 years warranty SPECIFICATION MODEL TN-1500-124 TN-1500-112 TN-1500-148 TN-1500-212 TN-1500-224 TN-1500-248 1500W RATED POWER (Typ.) MAXIMUM OUTPUT POWER (Typ.) 1725W for 180 sec. / 2250W for 10 sec. / surge power 3000W for 30 cycles Factory setting set at 110VAC Factory setting set at 230VAC 100 / 110 / 115 / 120VAC selectable by setting button S.W 200 / 220 / 230 / 240VAC selectable by setting button S.W FREQUENCY 60 0.1Hz 50 0.1%Hz WAVEFORM True sine wave (THD<3%) at rated input voltage AC VOLTAGE OUTPUT 50/60Hz selectable by setting button S.W 3.0% AC REGULATION (Typ.) TRANSFER TIME t<10ms inverter SAVING MODE (Typ.) Load by pass 5W will be changed to standby mode FRONT PANEL INDICATOR Battery voltage level, output load level, saving mode, fault and operation status BAT. VOLTAGE 12V 24V 48V 12V 24V 48V 21 ~ 30VDC 75A 42 ~ 60VDC 37.5A 10.5 ~ 15VDC 21 ~ 30VDC 42 ~ 60VDC 150A 75A 37.5A 89% Open & sealed Lead Acid 90% 88% 90% 91% 40A*5 11.3 4% 30A*3 22.5 4% 30A*2 45 4% 40A*5 11.3 4% 30A*3 22.5 4% 30A*2 45 4% 10.5 4% 21 4% 42 4% 10.5 4% 21 4% 42 4% 68 68 VOLTAGE RANGE (Typ.)Note.1 10.5 ~ 15VDC DC CURRENT (Typ.) INPUT Note.5 150A 18W @ standby saving mode NO LOAD DISSIPATION 1mA OFF MODE CURRENT DRAW EFFICIENCY (Typ.) Note.2 87% BATTERY TYPES FUSE BATTERY BAT. LOW ALARM INPUT PROTECTION BAT. LOW SHUTDOWN REVERSE POLARITY By internal fuse open 82 OVER TEMPERATURE SAFETY & EMC AC CHARGER WORKING HUMIDITY OTHERS NOTE 5 96 5 5 5 68 5 Protection type : Shut down o/p voltage, re-power on to recover Protection type : Shut down o/p voltage, re-power on to recover 20A 10A Optional (Only type F) Note.3 0 ~ +40 @ 100% load ; 60 @ 50% load 20% ~ 90% RH non-condensing STORAGE TEMP., HUMIDITY VIBRATION -30 ~ +70 None / -22 ~ +158oF, 10 ~ 95% RH SAFETY STANDARDS 10 ~ 500Hz, 3G 10min./1cycle, 60min. each along X, Y, Z axes UL458 (only for "GFCI" receptacle-Type F ) None LVD WITHSTAND VOLTAGE None Bat I/P - AC I/P:3.0KVAC Bat I/P - AC O/P:3.0KVAC EMI CONDUCTION&RADIATION Compliance to FCC class A None EMS IMMUNITY EN60950-1 AC O/P - FG:1.5KVAC Compliance to EN55022 class B, 72/ 245/ CEE, 95/ 54/ CE, E-Mark Compliance to EN61000-4-2,3,4,5,6,8,11 ENV50204 CHARGE CURRENT (Typ.) 5.5A 2.7A 1.35A 5.5A 2.7A 1.35A CHARGE VOLTAGE 14.3V 4% 28.5V 4% 57V 4% 14.3V 4% 28.5V 4% 57V 4% 45V 75V 25V 45V 75V 57V 4% 14.3V 4% 28.5V 4% 57V 4% MAX OPEN CIRCUIT VOLTAGE 25V SOLAR CHARGER 82 105 ~ 115% load for 180 sec., 115% ~ 150% load for 10 sec. CIRCUIT BREAKER ENVIRONMENT 5 Protection type : Shut down o/p voltage, re-power on to recover ; by internal RTH3 detect on heatsink of power transistor OUTPUT SHORT OUTPUT PROTECTION OVER LOAD (Typ.) GFCI PROCTECTION WORKING TEMP. 50/60Hz selectable by setting button S.W CHARGE CURRENT (max.) 30A CHARGE VOLTAGE CONTROL WIRING 28.5V 4% 14.3V 4% RJ11 -RS232 (Option) DIMENSION PACKING 420*220*88mm (L*W*H) 6.85Kg; 2pcs/14.7Kg/1.61CUFT 1.Output derating capacity referenced by curve 1. 2.Efficiency is tested by 1000W, linear load at 13V, 26V, 52V input voltage. 3.Output derating capacity referenced by curve 2. 4.All parameters not specified above are measured at rated load, 25 of ambient temperature. 5.DC current is tested by 1500W, linear load at 13V, 26V, 52V input voltage. File Name:TN-1500-SPEC 2009-02-07 1500W True Sine Wave DC-AC Inverter with Solar Charger TN-1500 series Instructions for TN-1500 monitoring software 1. Installation of TN-1500 unit and PC 9 8 7 6 1 6 5 4 3 2 1 Phone Jack RJ11 DB9 FEMALE RJ11 PIN NO. DB9 PIN NO. 2 3 4 3 5 2 Figure 1 2. Explanation of Monitoring Manu 2.1 Main Page Inverter TN V.1.1 Setting Statistics R.C. Power off Pause 2 3 4 1 Exit Solar Charge INVERTER 100 AC Charge 100 0 Battery 5 0 Loading O/P Voltage 110 V O/P Frequency 60.0 Hz Battery Voltage 54.1 V Internal Temperature 10.0 AC In By pass Utility Voltage 0.0 V TN-1500-143 6 Start Date 2007/12/07 03:13:33 PM Reset Date 2007/12/21 01:40:56 PM Power on Remote off Battery low Battery used up Stand by saving mode Abnormal Shutdown Figure 2 1. Setting: Adjustment for output voltage, charging related voltage, frequency, and operation mode. Please refer to Figure 3 for details. 2. Statistics: Calculate for the percentage of operating period for each operation mode. Please refer to Figure 4 for details. 3. R.C. Power off: Power can be turned ON or OFF at the remote location. 4. Pause: Stop refreshing the page of monitoring software. 5. Status of unit: Indicating current operating status of TN-1500. 6. Signals that display current condition of the unit. File Name:TN-1500-SPEC 2009-02-07 1500W True Sine Wave DC-AC Inverter with Solar Charger TN-1500 series 2.2 Setting Page Inverter Setting File Name D:\TN_110RR\20071205\REV\TN_110RR\TNF\TN_1K5_512.TNF Model name TN-1500-212 Manufacture MeanWell Series Number LOC-1234567890 Revision REV:1.10 Date Of Manu. 06/23/2007 I/O Type 212 Voltage 230 V Equalization Volt. 14.3 V 13.5 ~ 15.0V Floating Volt. 13.3 V 13.0 ~ 13.5V Alarm Volt. 11.3 V 11.0 ~ 11.5V Shutdown Volt. 10.5 V 10.0 ~ 11.0V 1 Frequency Stand-by saving mode UPS mode Energy saving mode 50 Hz Off On On On Comm Ports Bauds Rate 9600 1 Read Write Lead 2 3 4 Exit Read OK!! Figure 3 1. User can adjust the settings based on the characteristics of batteries been used: Equalization Voltage, Floating Voltage, Alarm Voltage, and Shut-down Voltage. UPS Mode / Energy Saving Mode selection and AC output voltage and frequency can also be set in this page. 2. Read: Read current settings of the unit. 3. Write: Write the revised setting into the unit. 4. Load: Load in factory default settings. 2.3 Statistic Page Inverter Setting Start Date 2007/12/07 03:13:33 PM Inverter time rate 91.2 % Bypass time rate 0.0 % Shut Down rate 8.8 % Solar time rate 0.0 % Loading average 24.7 % Start Date 2007/12/21 01:40:56 PM Inverter time rate 31.9 % Bypass time rate 0.0 % Shut Down rate 68.1 % Solar time rate 0.0 % Loading average 63.7 % RESET Exit Figure 4 1. Start Date: Date that installing the monitoring software. 2. Reset Date: Date that resetting the statistics. The Start Date will not be influenced by resetting the statistics or turning off the unit. 3 .Inverter time rate: Operating period of "Inverter Mode" represents how many percent of the whole operating period. 4. Bypass time rate: Operating period of "Bypass Mode" (energy provides directly by the utility) represents how many percent of the whole operating period. 5. Shut down rate: Percentage of time period that the unit is under the condition of shut down. * Inverter time rate + Bypass time rate + Shut down rate = 100% 6. Solar time rate: Percentage of time period that the solar charger is functioning after turning on the TN-1500 unit. 7. Loading average: Average loading after turning on the TN-1500 unit. File Name:TN-1500-SPEC 2009-02-07 TN-1500 1500W True Sine Wave DC-AC Inverter with Solar Charger TN 1500 112 A True sine wave inverter +AC charger and solar charger A :TYPE A OUTLET B :TYPE B OUTLET C :TYPE C OUTLET D :TYPE D OUTLET E :TYPE E OUTLET F :TYPE F OUTLET 12:12VDC Bat. Voltage: 24:24VDC 48:48VDC 1:110VAC 2:230VAC Output: O/P Wattage:1500W series AC Output Receptacles (optional) Receptacle type TYPE-A TYPE-B TYPE-C TYPE-D TYPE-E TYPE-F USA EUROPE AUSTRALIA U.K JAPAN GFCI Country E13 Certificate E13 E13 (Expect for 48V input) Mechanical Specification Unit:mm 44.25 11.05 88 108.4 Chassis Ground Reverse Polarity Will Damage The Unit. NEG POS 20 Solar Input (30A max) 10 AC INPUT 27.45 Cat.No.(1GG1HS-212) Wire Range(10-4 AWG Str Cu Soldered Wires) Torque (17.7-26.5 in lb) 12.1 22 DC INPUT 48 57.75 36.25 15.6 Air flow direction 203.2 420 7 47 AC OUTPUT SOLAR CHARGE ON AC CHARGE BATTERY OFF Setting LOAD 100 100 INVERTER On AC IN BY PASS Saving se t es Pr s Bat Low 0 er Ci c ak r 0 u it Br e to R e Remote port Type-A AC OUTPUT SOLAR CHARGE ON AC CHARGE BATTERY OFF 100 Setting LOAD 100 INVERTER On Ci er AC IN BY PASS Saving se t es Pr s Bat Low 0 ak r 0 it Br e cu to R e Remote port 207 220 Type-B File Name:TN-1500-SPEC 2009-02-07