ADC12D1800 ADC12D1800 12-Bit, Single 3.6 GSPS Ultra High-Speed ADC Literature Number: SNAS500L ADC12D1800 12-Bit, Single 3.6 GSPS Ultra High-Speed ADC 1.0 General Description 3.0 Features The 12-bit, 3.6 GSPS ADC12D1800 is the latest advance in National's Ultra-High-Speed ADC family and builds upon the features, architecture and functionality of the 10-bit GHz family of ADCs. The ADC12D1800 provides a flexible LVDS interface which has multiple SPI programmable options to facilitate board design and FPGA/ASIC data capture. The LVDS outputs are compatible with IEEE 1596.3-1996 and supports programmable common mode voltage. The product is packaged in a leaded or lead-free 292-ball thermally enhanced BGA package over the rated industrial temperature range of -40C to +85C. To achieve full rated performance for Fclk > 1.6GHz, it is necessary to write the max power settings once to Register 6h via the Serial Interface; see Section 19.0 Register Definitions for more information. Configurable to either 3.6 GSPS interleaved or 1.8 GSPS 2.0 Applications Interleaved 3.6 GSPS ADC Noise Floor Density IMD3 Noise Power Ratio Power Full Power Bandwidth Wideband Communications Data Acquisition Systems RADAR/LIDAR Set-top Box Consumer RF Software Defined Radio (c) 2011 Texas Instruments Incorporated dual ADC Pin-compatible with ADC10D1000/1500 and ADC12D1000/1600 Internally terminated, buffered, differential analog inputs Interleaved timing automatic and manual skew adjust Test patterns at output for system debug Programmable 15-bit gain and 12-bit plus sign offset Programmable tAD adjust feature 1:1 non-demuxed or 1:2 demuxed LVDS outputs AutoSync feature for multi-chip systems Single 1.9V 0.1V power supply 4.0 Key Specifications Resolution Dual 1.8 GSPS ADC, Fin = 125MHz ENOB SNR SFDR Power Full Power Bandwidth 301232 12 Bits -153.5 dBm/Hz (typ) -61 dBFS (typ) 48.5 dB (typ) 4.4W (typ) 1.75 GHz (typ) 9.4 (typ) 58.5 dB (typ) 73 dBc (typ) 4.4W (typ) 2.8 GHz (typ) www.ti.com ADC12D1800 12-Bit 3.6 GSPS Ultra High-Speed ADC October 31, 2011 ADC12D1800 5.0 Simplified Block Diagram 30123211 www.ti.com 2 ADC12D1800 6.0 Wideband Performance 30123298 Wideband Performance 7.0 Ordering Information Industrial Temperature Range (-40C < TA < +85C) NS Package ADC12D1800CIUT/NOPB Lead-free 292-Ball BGA Thermally Enhanced Package ADC12D1800CIUT Leaded 292-Ball BGA Thermally Enhanced Package ADC12D1800RB Reference Board If Military/Aerospace specified devices are required, please contact the National Semiconductor Sales Office/Distributors for availability and specifications. IBIS models are available at: http://www.national.com/analog/adc/ibis_models. 3 www.ti.com ADC12D1800 Table of Contents 1.0 General Description ......................................................................................................................... 1 2.0 Applications .................................................................................................................................... 1 3.0 Features ........................................................................................................................................ 1 4.0 Key Specifications ........................................................................................................................... 1 5.0 Simplified Block Diagram .................................................................................................................. 2 6.0 Wideband Performance .................................................................................................................... 3 7.0 Ordering Information ....................................................................................................................... 3 8.0 Connection Diagram ........................................................................................................................ 7 9.0 Ball Descriptions and Equivalent Circuits ............................................................................................ 8 10.0 Absolute Maximum Ratings ........................................................................................................... 17 11.0 Operating Ratings ....................................................................................................................... 17 12.0 Converter Electrical Characteristics ................................................................................................ 18 13.0 Specification Definitions ................................................................................................................ 28 14.0 Transfer Characteristic ................................................................................................................. 30 15.0 Timing Diagrams ......................................................................................................................... 31 16.0 Typical Performance Plots ............................................................................................................ 34 17.0 Functional Description .................................................................................................................. 39 17.1 OVERVIEW ......................................................................................................................... 39 17.2 CONTROL MODES .............................................................................................................. 39 17.2.1 Non-Extended Control Mode ........................................................................................ 39 17.2.1.1 Dual Edge Sampling Pin (DES) ........................................................................... 39 17.2.1.2 Non-Demultiplexed Mode Pin (NDM) ................................................................... 39 17.2.1.3 Dual Data Rate Phase Pin (DDRPh) .................................................................... 40 17.2.1.4 Calibration Pin (CAL) ......................................................................................... 40 17.2.1.5 Calibration Delay Pin (CalDly) ............................................................................ 40 17.2.1.6 Power Down I-channel Pin (PDI) ......................................................................... 40 17.2.1.7 Power Down Q-channel Pin (PDQ) ...................................................................... 40 17.2.1.8 Test Pattern Mode Pin (TPM) ............................................................................. 40 17.2.1.9 Full-Scale Input Range Pin (FSR) ....................................................................... 40 17.2.1.10 AC/DC-Coupled Mode Pin (VCMO) ..................................................................... 40 17.2.1.11 LVDS Output Common-mode Pin (VBG) ............................................................. 40 17.2.2 Extended Control Mode ............................................................................................... 41 17.2.2.1 The Serial Interface ........................................................................................... 41 17.3 FEATURES ......................................................................................................................... 43 17.3.1 Input Control and Adjust .............................................................................................. 44 17.3.1.1 AC/DC-coupled Mode ........................................................................................ 44 17.3.1.2 Input Full-Scale Range Adjust ............................................................................ 44 17.3.1.3 Input Offset Adjust ............................................................................................ 44 17.3.1.4 DES/Non-DES Mode ......................................................................................... 44 17.3.1.5 DES Timing Adjust ............................................................................................ 44 17.3.1.6 Sampling Clock Phase Adjust ............................................................................. 44 17.3.2 Output Control and Adjust ............................................................................................ 44 17.3.2.1 DDR Clock Phase ............................................................................................. 44 17.3.2.2 LVDS Output Differential Voltage ........................................................................ 45 17.3.2.3 LVDS Output Common-Mode Voltage ................................................................. 45 17.3.2.4 Output Formatting ............................................................................................. 45 17.3.2.5 Demux/Non-demux Mode .................................................................................. 45 17.3.2.6 Test Pattern Mode ............................................................................................ 45 17.3.2.7 Time Stamp ..................................................................................................... 45 17.3.3 Calibration Feature ..................................................................................................... 46 17.3.3.1 Calibration Control Pins and Bits ......................................................................... 46 17.3.3.2 How to Execute a Calibration .............................................................................. 46 17.3.3.3 Power-on Calibration ......................................................................................... 46 17.3.3.4 On-command Calibration ................................................................................... 46 17.3.3.5 Calibration Adjust .............................................................................................. 46 17.3.3.6 Read/Write Calibration Settings .......................................................................... 46 17.3.3.7 Calibration and Power-Down .............................................................................. 47 17.3.3.8 Calibration and the Digital Outputs ...................................................................... 47 17.3.4 Power Down .............................................................................................................. 47 18.0 Applications Information ............................................................................................................... 48 18.1 THE ANALOG INPUTS ......................................................................................................... 48 18.1.1 Acquiring the Input ...................................................................................................... 48 18.1.2 Driving the ADC in DES Mode ...................................................................................... 48 18.1.3 FSR and the Reference Voltage ................................................................................... 49 www.ti.com 4 49 49 49 49 49 50 50 50 50 50 50 50 50 50 50 51 51 51 51 52 52 52 52 52 54 54 54 56 56 56 57 57 57 58 65 List of Figures FIGURE 1. ADC12D1800 Connection Diagram ................................................................................................ 7 FIGURE 2. LVDS Output Signal Levels ......................................................................................................... 28 FIGURE 3. Input / Output Transfer Characteristic ............................................................................................ 30 FIGURE 4. Clocking in 1:2 Demux Non-DES Mode* ......................................................................................... 31 FIGURE 5. Clocking in Non-Demux Non-DES Mode* ........................................................................................ 31 FIGURE 6. Clocking in 1:4 Demux DES Mode* ............................................................................................... 32 FIGURE 7. Clocking in Non-Demux Mode DES Mode* ...................................................................................... 32 FIGURE 8. Data Clock Reset Timing (Demux Mode) ........................................................................................ 33 FIGURE 9. Power-on and On-Command Calibration Timing ................................................................................ 33 FIGURE 10. Serial Interface Timing ............................................................................................................. 33 FIGURE 11. Serial Data Protocol - Read Operation .......................................................................................... 41 FIGURE 12. Serial Data Protocol - Write Operation .......................................................................................... 42 FIGURE 13. DDR DCLK-to-Data Phase Relationship ........................................................................................ 45 FIGURE 14. Driving DESIQ Mode ............................................................................................................... 48 FIGURE 15. AC-coupled Differential Input ..................................................................................................... 49 FIGURE 16. Single-Ended to Differential Conversion Using a Balun ...................................................................... 49 FIGURE 17. Differential Input Clock Connection .............................................................................................. 50 FIGURE 18. AutoSync Example ................................................................................................................. 51 FIGURE 19. Power and Grounding Example .................................................................................................. 53 FIGURE 20. HSBGA Conceptual Drawing ..................................................................................................... 54 FIGURE 21. Power-on with Control Pins set by Pull-up/down Resistors .................................................................. 55 FIGURE 22. Power-on with Control Pins set by FPGA pre Power-on Cal ................................................................ 55 FIGURE 23. Power-on with Control Pins set by FPGA post Power-on Cal ............................................................... 56 FIGURE 24. Supply and DCLK Ramping ....................................................................................................... 56 FIGURE 25. Typical Temperature Sensor Application ....................................................................................... 57 List of Tables TABLE 1. Analog Front-End and Clock Balls ................................................................................................... 8 TABLE 2. Control and Status Balls .............................................................................................................. 11 5 www.ti.com ADC12D1800 18.1.4 Out-Of-Range Indication .............................................................................................. 18.1.5 Maximum Input Range ................................................................................................ 18.1.6 AC-coupled Input Signals ............................................................................................ 18.1.7 DC-coupled Input Signals ............................................................................................ 18.1.8 Single-Ended Input Signals .......................................................................................... 18.2 THE CLOCK INPUTS ........................................................................................................... 18.2.1 CLK Coupling ............................................................................................................. 18.2.2 CLK Frequency .......................................................................................................... 18.2.3 CLK Level .................................................................................................................. 18.2.4 CLK Duty Cycle .......................................................................................................... 18.2.5 CLK Jitter .................................................................................................................. 18.2.6 CLK Layout ................................................................................................................ 18.3 THE LVDS OUTPUTS ........................................................................................................... 18.3.1 Common-mode and Differential Voltage ......................................................................... 18.3.2 Output Data Rate ........................................................................................................ 18.3.3 Terminating Unused LVDS Output Pins ......................................................................... 18.4 SYNCHRONIZING MULTIPLE ADC12D1800S IN A SYSTEM .................................................... 18.4.1 AutoSync Feature ....................................................................................................... 18.4.2 DCLK Reset Feature ................................................................................................... 18.5 SUPPLY/GROUNDING, LAYOUT AND THERMAL RECOMMENDATIONS ................................. 18.5.1 Power Planes ............................................................................................................. 18.5.2 Bypass Capacitors ...................................................................................................... 18.5.3 Ground Planes ........................................................................................................... 18.5.4 Power System Example ............................................................................................... 18.5.5 Thermal Management ................................................................................................. 18.6 SYSTEM POWER-ON CONSIDERATIONS ............................................................................. 18.6.1 Power-on, Configuration, and Calibration ....................................................................... 18.6.2 Power-on and Data Clock (DCLK) ................................................................................. 18.7 RECOMMENDED SYSTEM CHIPS ........................................................................................ 18.7.1 Temperature Sensor ................................................................................................... 18.7.2 Clocking Device ......................................................................................................... 18.7.3 Amplifiers for Analog Input ........................................................................................... 18.7.4 Balun Recommendations for Analog Input ...................................................................... 19.0 Register Definitions ...................................................................................................................... 20.0 Physical Dimensions .................................................................................................................... ADC12D1800 TABLE 3. Power and Ground Balls .............................................................................................................. TABLE 4. High-Speed Digital Outputs .......................................................................................................... TABLE 5. Package Thermal Resistance ........................................................................................................ TABLE 6. Static Converter Characteristics ..................................................................................................... TABLE 7. Dynamic Converter Characteristics ................................................................................................ TABLE 8. Analog Input/Output and Reference Characteristics ............................................................................. TABLE 9. I-Channel to Q-Channel Characteristics ............................................................................................ TABLE 10. Sampling Clock Characteristics ................................................................................................... TABLE 11. AutoSync Feature Characteristics ................................................................................................ TABLE 12. Digital Control and Output Pin Characteristics ................................................................................... TABLE 13. Power Supply Characteristics ...................................................................................................... TABLE 14. AC Electrical Characteristics ........................................................................................................ TABLE 15. Serial Port Interface ................................................................................................................. TABLE 16. Calibration ............................................................................................................................. TABLE 17. Non-ECM Pin Summary ............................................................................................................. TABLE 18. Serial Interface Pins .................................................................................................................. TABLE 19. Command and Data Field Definitions ............................................................................................. TABLE 20. Features and Modes ................................................................................................................ TABLE 21. Test Pattern by Output Port in Demux Mode .................................................................................... TABLE 22. Test Pattern by Output Port in Non-Demux Mode .............................................................................. TABLE 23. Calibration Pins ....................................................................................................................... TABLE 24. Output Latency in Demux Mode ................................................................................................... TABLE 25. Output Latency in Non-Demux Mode ............................................................................................. TABLE 26. Unused Analog Input Recommended Termination ............................................................................. TABLE 27. Unused AutoSync and DCLK Reset Pin Recommendation ................................................................... TABLE 28. Temperature Sensor Recommendation .......................................................................................... TABLE 29. Amplifier Recommendation ......................................................................................................... TABLE 30. Balun Recommendations ............................................................................................................ TABLE 31. Register Addresses .................................................................................................................. www.ti.com 6 14 15 17 18 18 21 22 22 22 23 24 24 26 26 39 41 41 43 45 45 46 48 48 48 51 56 57 57 58 ADC12D1800 8.0 Connection Diagram 30123201 FIGURE 1. ADC12D1800 Connection Diagram The center ground pins are for thermal dissipation and must be soldered to a ground plane to ensure rated performance. See Section 18.5 SUPPLY/GROUNDING, LAYOUT AND THERMAL RECOMMENDATIONS for more information. 7 www.ti.com ADC12D1800 9.0 Ball Descriptions and Equivalent Circuits TABLE 1. Analog Front-End and Clock Balls Ball No. Name H1/J1 N1/M1 VinI+/VinQ+/- U2/V1 V2/W1 www.ti.com Equivalent Circuit Description Differential signal I- and Q-inputs. In the Non-Dual Edge Sampling (Non-DES) Mode, each I- and Q-input is sampled and converted by its respective channel with each positive transition of the CLK input. In Non-ECM (Non-Extended Control Mode) and DES Mode, both channels sample the I-input. In Extended Control Mode (ECM), the Qinput may optionally be selected for conversion in DES Mode by the DEQ Bit (Addr: 0h, Bit 6). Each I- and Q-channel input has an internal common mode bias that is disabled when DC-coupled Mode is selected. Both inputs must be either AC- or DC-coupled. The coupling mode is selected by the VCMO Pin. In Non-ECM, the full-scale range of these inputs is determined by the FSR Pin; both I- and Qchannels have the same full-scale input range. In ECM, the full-scale input range of the I- and Qchannel inputs may be independently set via the Control Register (Addr: 3h and Addr: Bh). The input offset may also be adjusted in ECM. CLK+/- Differential Converter Sampling Clock. In the Non-DES Mode, the analog inputs are sampled on the positive transitions of this clock signal. In the DES Mode, the selected input is sampled on both transitions of this clock. This clock must be AC-coupled. DCLK_RST+/- Differential DCLK Reset. A positive pulse on this input is used to reset the DCLKI and DCLKQ outputs of two or more ADC12D1800s in order to synchronize them with other ADC12D1800s in the system. DCLKI and DCLKQ are always in phase with each other, unless one channel is powered down, and do not require a pulse from DCLK_RST to become synchronized. The pulse applied here must meet timing relationships with respect to the CLK input. Although supported, this feature has been superseded by AutoSync. 8 C2 B1 C3/D3 C1/D2 E2/F3 Name Equivalent Circuit Description VCMO Common Mode Voltage Output or Signal Coupling Select. If AC-coupled operation at the analog inputs is desired, this pin should be held at logic-low level. This pin is capable of sourcing/ sinking up to 100 A. For DC-coupled operation, this pin should be left floating or terminated into high-impedance. In DC-coupled Mode, this pin provides an output voltage which is the optimal common-mode voltage for the input signal and should be used to set the common-mode voltage of the driving buffer. VBG Bandgap Voltage Output or LVDS Commonmode Voltage Select. This pin provides a buffered version of the bandgap output voltage and is capable of sourcing/sinking 100 uA and driving a load of up to 80 pF. Alternately, this pin may be used to select the LVDS digital output common-mode voltage. If tied to logic-high, the 1.2V LVDS common-mode voltage is selected; 0.8V is the default. Rext+/- External Reference Resistor terminals. A 3.3 k 0.1% resistor should be connected between Rext+/-. The Rext resistor is used as a reference to trim internal circuits which affect the linearity of the converter; the value and precision of this resistor should not be compromised. Rtrim+/- Input Termination Trim Resistor terminals. A 3.3 k 0.1% resistor should be connected between Rtrim+/-. The Rtrim resistor is used to establish the calibrated 100 input impedance of VinI, VinQ and CLK. These impedances may be fine tuned by varying the value of the resistor by a corresponding percentage; however, the tuning range and performance is not guaranteed for such an alternate value. Tdiode+/- Temperature Sensor Diode Positive (Anode) and Negative (Cathode) Terminals. This set of pins is used for die temperature measurements. It has not been fully characterized. 9 www.ti.com ADC12D1800 Ball No. ADC12D1800 Ball No. Y4/W5 Y5/U6 V6/V7 www.ti.com Name Equivalent Circuit Description RCLK+/- Reference Clock Input. When the AutoSync feature is active, and the ADC12D1800 is in Slave Mode, the internal divided clocks are synchronized with respect to this input clock. The delay on this clock may be adjusted when synchronizing multiple ADCs. This feature is available in ECM via Control Register (Addr: Eh). RCOut1+/RCOut2+/- Reference Clock Output 1 and 2. These signals provide a reference clock at a rate of CLK/4, when enabled, independently of whether the ADC is in Master or Slave Mode. They are used to drive the RCLK of another ADC12D1800, to enable automatic synchronization for multiple ADCs (AutoSync feature). The impedance of each trace from RCOut1 and RCOut2 to the RCLK of another ADC12D1800 should be 100 differential. Having two clock outputs allows the auto-synchronization to propagate as a binary tree. Use the DOC Bit (Addr: Eh, Bit 1) to enable/ disable this feature; default is disabled. 10 Ball No. Name Equivalent Circuit Description DES Dual Edge Sampling (DES) Mode select. In the Non-Extended Control Mode (Non-ECM), when this input is set to logic-high, the DES Mode of operation is selected, meaning that the VinI input is sampled by both channels in a time-interleaved manner. The VinQ input is ignored. When this input is set to logic-low, the device is in Non-DES Mode, i.e. the I- and Q-channels operate independently. In the Extended Control Mode (ECM), this input is ignored and DES Mode selection is controlled through the Control Register by the DES Bit (Addr: 0h, Bit 7); default is Non-DES Mode operation. CalDly Calibration Delay select. By setting this input logic-high or logic-low, the user can select the device to wait a longer or shorter amount of time, respectively, before the automatic power-on selfcalibration is initiated. This feature is pincontrolled only and is always active during ECM and Non-ECM. D6 CAL Calibration cycle initiate. The user can command the device to execute a self-calibration cycle by holding this input high a minimum of tCAL_H after having held it low a minimum of tCAL_L. If this input is held high at the time of power-on, the automatic power-on calibration cycle is inhibited until this input is cycled low-then-high. This pin is active in both ECM and Non-ECM. In ECM, this pin is logically OR'd with the CAL Bit (Addr: 0h, Bit 15) in the Control Register. Therefore, both pin and bit must be set low and then either can be set high to execute an on-command calibration. B5 CalRun V5 V4 Calibration Running indication. This output is logic-high while the calibration sequence is executing. This output is logic-low otherwise. 11 www.ti.com ADC12D1800 TABLE 2. Control and Status Balls ADC12D1800 Ball No. U3 V3 A4 A5 Y3 W4 www.ti.com Name Equivalent Circuit Description PDI PDQ Power Down I- and Q-channel. Setting either input to logic-high powers down the respective Ior Q-channel. Setting either input to logic-low brings the respective I- or Q-channel to an operational state after a finite time delay. This pin is active in both ECM and Non-ECM. In ECM, each Pin is logically OR'd with its respective Bit. Therefore, either this pin or the PDI and PDQ Bit in the Control Register can be used to powerdown the I- and Q-channel (Addr: 0h, Bit 11 and Bit 10), respectively. TPM Test Pattern Mode select. With this input at logichigh, the device continuously outputs a fixed, repetitive test pattern at the digital outputs. In the ECM, this input is ignored and the Test Pattern Mode can only be activated through the Control Register by the TPM Bit (Addr: 0h, Bit 12). NDM Non-Demuxed Mode select. Setting this input to logic-high causes the digital output bus to be in the 1:1 Non-Demuxed Mode. Setting this input to logic-low causes the digital output bus to be in the 1:2 Demuxed Mode. This feature is pin-controlled only and remains active during ECM and NonECM. FSR Full-Scale input Range select. In Non-ECM, this input must be set to logic-high; the full-scale differential input range for both I- and Q-channel inputs is set by this pin. In the ECM, this input is ignored and the full-scale range of the I- and Qchannel inputs is independently determined by the setting of Addr: 3h and Addr: Bh, respectively. Note that the logic-high FSR value in NonECM corresponds to the minimum allowed selection in ECM. DDRPh DDR Phase select. This input, when logic-low, selects the 0 Data-to-DCLK phase relationship. When logic-high, it selects the 90 Data-to-DCLK phase relationship, i.e. the DCLK transition indicates the middle of the valid data outputs. This pin only has an effect when the chip is in 1:2 Demuxed Mode, i.e. the NDM pin is set to logiclow. In ECM, this input is ignored and the DDR phase is selected through the Control Register by the DPS Bit (Addr: 0h, Bit 14); the default is 0 Mode. 12 Name Equivalent Circuit Description ECE Extended Control Enable bar. Extended feature control through the SPI interface is enabled when this signal is asserted (logic-low). In this case, most of the direct control pins have no effect. When this signal is de-asserted (logic-high), the SPI interface is disabled, all SPI registers are reset to their default values, and all available settings are controlled via the control pins. SCS Serial Chip Select bar. In ECM, when this signal is asserted (logic-low), SCLK is used to clock in serial data which is present on SDI and to source serial data on SDO. When this signal is deasserted (logic-high), SDI is ignored and SDO is in TRI-STATE. C5 SCLK Serial Clock. In ECM, serial data is shifted into and out of the device synchronously to this clock signal. This clock may be disabled and held logiclow, as long as timing specifications are not violated when the clock is enabled or disabled. B4 SDI Serial Data-In. In ECM, serial data is shifted into the device on this pin while SCS signal is asserted (logic-low). A3 SDO Serial Data-Out. In ECM, serial data is shifted out of the device on this pin while SCS signal is asserted (logic-low). This output is at TRI-STATE when SCS is de-asserted. D1, D7, E3, F4, W3, U7 DNC NONE Do Not Connect. These pins are used for internal purposes and should not be connected, i.e. left floating. Do not ground. C7 NC NONE Not Connected. This pin is not bonded and may be left floating or connected to any potential. B3 C4 13 www.ti.com ADC12D1800 Ball No. ADC12D1800 TABLE 3. Power and Ground Balls Ball No. Name Equivalent Circuit A2, A6, B6, C6, D8, D9, E1, F1, H4, N4, R1, T1, U8, U9, W6, Y2, Y6 VA NONE Power Supply for the Analog circuitry. This supply is tied to the ESD ring. Therefore, it must be powered up before or with any other supply. G1, G3, G4, H2, J3, K3, L3, M3, N2, P1, P3, P4, R3, R4 VTC NONE Power Supply for the Track-and-Hold and Clock circuitry. A11, A15, C18, D11, D15, D17, J17, J20, R17, R20, T17, U11, U15, U16, Y11, Y15 VDR NONE Power Supply for the Output Drivers. A8, B9, C8, V8, W9, Y8 VE NONE Power Supply for the Digital Encoder. NONE Bias Voltage I-channel. This is an externally decoupled bias voltage for the I-channel. Each pin should individually be decoupled with a 100 nF capacitor via a low resistance, low inductance path to GND. J4, K2 VbiasI Description L2, M4 VbiasQ NONE Bias Voltage Q-channel. This is an externally decoupled bias voltage for the Q-channel. Each pin should individually be decoupled with a 100 nF capacitor via a low resistance, low inductance path to GND. A1, A7, B2, B7, D4, D5, E4, K1, L1, T4, U4, U5, W2, W7, Y1, Y7, H8:N13 GND NONE Ground Return for the Analog circuitry. F2, G2, H3, J2, K4, L4, M2, N3, P2, R2, T2, T3, U1 GNDTC NONE Ground Return for the Track-and-Hold and Clock circuitry. A13, A17, A20, D13, D16, E17, F17, F20, M17, M20, U13, U17, V18, Y13, Y17, Y20 GNDDR NONE Ground Return for the Output Drivers. A9, B8, C9, V9, W8, Y9 GNDE NONE Ground Return for the Digital Encoder. www.ti.com 14 ADC12D1800 TABLE 4. High-Speed Digital Outputs Ball No. K19/K20 L19/L20 K17/K18 L17/L18 Name Equivalent Circuit Description DCLKI+/DCLKQ+/- Data Clock Output for the I- and Q-channel data bus. These differential clock outputs are used to latch the output data and, if used, should always be terminated with a 100 differential resistor placed as closely as possible to the differential receiver. Delayed and non-delayed data outputs are supplied synchronously to this signal. In 1:2 Demux Mode or Non-Demux Mode, this signal is at 1/4 or 1/2 the sampling clock rate, respectively. DCLKI and DCLKQ are always in phase with each other, unless one channel is powered down, and do not require a pulse from DCLK_RST to become synchronized. ORI+/ORQ+/- Out-of-Range Output for the I- and Q-channel. This differential output is asserted logic-high while the over- or under-range condition exists, i.e. the differential signal at each respective analog input exceeds the full-scale value. Each OR result refers to the current Data, with which it is clocked out. If used, each of these outputs should always be terminated with a 100 differential resistor placed as closely as possible to the differential receiver. 15 www.ti.com ADC12D1800 Ball No. Name J18/J19 H19/H20 H17/H18 G19/G20 G17/G18 F18/F19 E19/E20 D19/D20 D18/E18 C19/C20 B19/B20 B18/C17 * M18/M19 N19/N20 N17/N18 P19/P20 P17/P18 R18/R19 T19/T20 U19/U20 U18/T18 V19/V20 W19/W20 W18/V17 DI11+/DI10+/DI9+/DI8+/DI7+/DI6+/DI5+/DI4+/DI3+/DI2+/DI1+/DI0+/* DQ11+/DQ10+/DQ9+/DQ8+/DQ7+/DQ6+/DQ5+/DQ4+/DQ3+/DQ2+/DQ1+/DQ0+/- I- and Q-channel Digital Data Outputs. In NonDemux Mode, this LVDS data is transmitted at the sampling clock rate. In Demux Mode, these outputs provide 1/2 the data at 1/2 the sampling clock rate, synchronized with the delayed data, i.e. the other 1/2 of the data which was sampled one clock cycle earlier. Compared with the DId and DQd outputs, these outputs represent the later time samples. If used, each of these outputs should always be terminated with a 100 differential resistor placed as closely as possible to the differential receiver. A18/A19 B17/C16 A16/B16 B15/C15 C14/D14 A14/B14 B13/C13 C12/D12 A12/B12 B11/C11 C10/D10 A10/B10 * Y18/Y19 W17/V16 Y16/W16 W15/V15 V14/U14 Y14/W14 W13/V13 V12/U12 Y12/W12 W11/V11 V10/U10 Y10/W10 DId11+/DId10+/DId9+/DId8+/DId7+/DId6+/DId5+/DId4+/DId3+/DId2+/DId1+/DId0+/* DQd11+/DQd10+/DQd9+/DQd8+/DQd7+/DQd6+/DQd5+/DQd4+/DQd3+/DQd2+/DQd1+/DQd0+/- Delayed I- and Q-channel Digital Data Outputs. In Non-Demux Mode, these outputs are at TRISTATE. In Demux Mode, these outputs provide 1/2 the data at 1/2 the sampling clock rate, synchronized with the non-delayed data, i.e. the other 1/2 of the data which was sampled one clock cycle later. Compared with the DI and DQ outputs, these outputs represent the earlier time samples. If used, each of these outputs should always be terminated with a 100 differential resistor placed as closely as possible to the differential receiver. www.ti.com Equivalent Circuit 16 Description 11.0 Operating Ratings (Note 1, Note 2) (Note 1, Note 2) Supply Voltage (VA, VTC, VDR, VE) Supply Difference max(VA/TC/DR/E)min(VA/TC/DR/E) Voltage on Any Input Pin (except VIN+/-) 0V to 100 mV -0.15V to (VA + 0.15V) VIN+/- Voltage Range -0.5V to 2.5V Ground Difference max(GNDTC/DR/E) -min(GNDTC/DR/E) Input Current at Any Pin (Note 3) ADC12D1800 Package Power Dissipation at TA 65C (Note 3) ESD Susceptibility (Note 4) Human Body Model Charged Device Model Machine Model Storage Temperature Ambient Temperature Range ADC12D1800 (Standard JEDEC -40C TA +50C thermal model) ADC12D1800 (Enhanced thermal -40C TA +85C model/heatsink) Junction Temperature Range applies only to maximum operating TJ +120C speed Supply Voltage (VA, VTC, VE) +1.8V to +2.0V Driver Supply Voltage (VDR) +1.8V to VA 2.2V 0V to 100 mV 50 mA VIN+/- Voltage Range (Note 15) VIN+/- Differential Voltage Range (Note 18) 4.95 W 2500V 1000V 250V -65C to +150C VIN+/- Current Range (Note 15) -0.4V to 2.4V (d.c.-coupled) 1.0V (d.c.-coupled @100% duty cycle) 2.0V (d.c.-coupled @20% duty cycle) 2.8V (d.c.-coupled @10% duty cycle) 50 mA peak (a.c.-coupled) Ground Difference max(GNDTC/DR/E) -min(GNDTC/DR/E) 0V 0V to VA CLK+/- Voltage Range Differential CLK Amplitude 0.4VP-P to 2.0VP-P Common Mode Input Voltage VCMO - 150mV < VCMI < VCMO +150mV TABLE 5. Package Thermal Resistance Package JA 292-Ball BGA Thermally 16C/W Enhanced Package JC1 JC2 2.9C/W 2.5C/W Soldering process must comply with National Semiconductor's Reflow Temperature Profile specifications. Refer to www.national.com/packaging. (Note 5) 17 www.ti.com ADC12D1800 10.0 Absolute Maximum Ratings ADC12D1800 12.0 Converter Electrical Characteristics Unless otherwise specified, the following apply after calibration for VA = VDR = VTC = VE = +1.9V; I- and Q-channels, AC-coupled, unused channel terminated to AC ground, FSR Pin = High; CL = 10 pF; Differential, AC coupled Sine Wave Sampling Clock, fCLK = 1.8 GHz at 0.5 VP-P with 50% duty cycle (as specified); VBG = Floating; Extended Control Mode with Register 6h written to 1C00h; Rext = Rtrim = 3300 0.1%; Analog Signal Source Impedance = 100 Differential; 1:2 Demultiplex Non-DES Mode; Duty Cycle Stabilizer on. Boldface limits apply for TA = TMIN to TMAX and for TJ < 105C. All other limits TA = 25C, unless otherwise noted. (Note 6, Note 7, Note 8) TABLE 6. Static Converter Characteristics Symbol Parameter Conditions ADC12D1800 Typ Lim Units (Limits) 12 bits Resolution with No Missing Codes INL Integral Non-Linearity (Best fit) 1 MHz DC-coupled over-ranged sine wave 2.5 LSB (max) DNL Differential Non-Linearity 1 MHz DC-coupled over-ranged sine wave 0.4 LSB (max) VOFF Offset Error 5 LSB VOFF_ADJ Input Offset Adjustment Range Extended Control Mode 45 mV PFSE Positive Full-Scale Error (Note 9) 25 mV (max) NFSE Negative Full-Scale Error (Note 9) 25 mV (max) Out-of-Range Output Code (Note (VIN+) - (VIN-) > + Full Scale 10) (VIN+) - (VIN-) < - Full Scale 4095 0 TABLE 7. Dynamic Converter Characteristics Symbol FPBW Parameter Full Power Bandwidth Gain Flatness Conditions ADC12D1800 Typ Lim Units (Limits) Non-DES Mode 2.8 GHz DESI, DESQ Mode 1.25 GHz DESIQ Mode 1.75 GHz D.C. to Fs/2 0.5 dB D.C. to Fs 1.2 dB 4.0 dB Non-DES Mode DESI, DESQ Mode D.C. to Fs/2 DESIQ Mode D.C. to Fs/2 3.6 dB 10-18 Error/ Sample CER Code Error Rate NPR Noise Power Ratio (Note 16) 48.5 dB IMD3 3rd order Intermodulation Distortion DESIQ Mode FIN1 = 1212.52MHz @ -7dBFS FIN2 = 1217.52 MHz @ -7dBFS -61 dBFS -54 dBc Noise Floor Density 50 single-ended termination, DES Mode -153.5 dBm/Hz -152.5 dBFS/Hz Wideband input, DES Mode (Note 17) -152.6 dBm/Hz -151.6 dBFS/Hz www.ti.com 18 Parameter Conditions ADC12D1800 Typ Lim Units (Limits) Non-DES Mode (Note 12, Note 14) ENOB SINAD SNR THD 2nd Harm 3rd Harm SFDR Effective Number of Bits Signal-to-Noise Plus Distortion Ratio Signal-to-Noise Ratio Total Harmonic Distortion Second Harmonic Distortion Third Harmonic Distortion Spurious-Free Dynamic Range AIN = 125 MHz @ -0.5 dBFS 9.4 AIN = 248 MHz @ -0.5 dBFS 9.2 8.4 bits (min) AIN = 498 MHz @ -0.5 dBFS 9.1 8.4 bits (min) AIN = 1147 MHz @ -0.5 dBFS 8.5 bits AIN = 1448 MHz @ -0.5 dBFS 8.4 bits bits AIN = 125 MHz @ -0.5 dBFS 58 AIN = 248 MHz @ -0.5 dBFS 57.3 52.1 dB (min) AIN = 498 MHz @ -0.5 dBFS 56.3 52.1 dB (min) AIN = 1147 MHz @ -0.5 dBFS 52.9 dB AIN = 1448 MHz @ -0.5 dBFS 52.5 dB AIN = 125 MHz @ -0.5 dBFS 58.6 dB AIN = 248 MHz @ -0.5 dBFS 57.8 52.9 dB (min) AIN = 498 MHz @ -0.5 dBFS 57.3 52.9 dB (min) AIN = 1147 MHz @ -0.5 dBFS 53.9 dB AIN = 1448 MHz @ -0.5 dBFS 53.1 dB AIN = 125 MHz @ -0.5 dBFS -68.5 AIN = 248 MHz @ -0.5 dBFS -66.6 -60 dB (max) AIN = 498 MHz @ -0.5 dBFS -63.2 -60 dB (max) AIN = 1147 MHz @ -0.5 dBFS -59.5 AIN = 1448 MHz @ -0.5 dBFS -61.1 dB AIN = 125 MHz @ -0.5 dBFS 73 dBc AIN = 248 MHz @ -0.5 dBFS 87 dBc AIN = 498 MHz @ -0.5 dBFS 70 dBc AIN = 1147 MHz @ -0.5 dBFS 62 dBc AIN = 1448 MHz @ -0.5 dBFS 66 dBc AIN = 125 MHz @ -0.5 dBFS 76.8 dBc AIN = 248 MHz @ -0.5 dBFS 67.4 dBc AIN = 498 MHz @ -0.5 dBFS 66.3 dBc AIN = 1147 MHz @ -0.5 dBFS 63 dBc AIN = 1448 MHz @ -0.5 dBFS 63.6 dBc AIN = 125 MHz @ -0.5 dBFS 73 dBc AIN = 248 MHz @ -0.5 dBFS 67.5 58 dBc (min) AIN = 498 MHz @ -0.5 dBFS 66.1 58 dBc (min) AIN = 1147 MHz @ -0.5 dBFS 60.2 dBc AIN = 1448 MHz @ -0.5 dBFS 60.3 dBc 19 dB dB dB www.ti.com ADC12D1800 Symbol ADC12D1800 Symbol Parameter Conditions ADC12D1800 Typ Lim Units (Limits) DES Mode (Note 12, Note 13, Note 14) ENOB SINAD SNR THD 2nd Harm 3rd Harm SFDR www.ti.com Effective Number of Bits Signal-to-Noise Plus Distortion Ratio Signal-to-Noise Ratio Total Harmonic Distortion Second Harmonic Distortion Third Harmonic Distortion Spurious-Free Dynamic Range AIN = 125 MHz @ -0.5 dBFS 8.9 AIN = 248 MHz @ -0.5 dBFS 8.8 AIN = 498 MHz @ -0.5 dBFS 8.6 bits AIN = 1147 MHz @ -0.5 dBFS 8 bits AIN = 1448 MHz @ -0.5 dBFS 8 bits AIN = 125 MHz @ -0.5 dBFS 55.6 AIN = 248 MHz @ -0.5 dBFS 54.8 AIN = 498 MHz @ -0.5 dBFS 53.8 dB AIN = 1147 MHz @ -0.5 dBFS 50 dB AIN = 1448 MHz @ -0.5 dBFS 49.8 dB AIN = 125 MHz @ -0.5 dBFS 55.8 dB AIN = 248 MHz @ -0.5 dBFS 55.3 AIN = 498 MHz @ -0.5 dBFS 54.5 dB AIN = 1147 MHz @ -0.5 dBFS 50.4 dB AIN = 1448 MHz @ -0.5 dBFS 50.1 dB AIN = 125 MHz @ -0.5 dBFS -67.8 AIN = 248 MHz @ -0.5 dBFS -65 bits 8.4 bits dB 52.1 52.9 dB dB dB -60 dB AIN = 498 MHz @ -0.5 dBFS -62 dB AIN = 1147 MHz @ -0.5 dBFS -60.6 dB AIN = 1448 MHz @ -0.5 dBFS -61.9 dB AIN = 125 MHz @ -0.5 dBFS 78 dBc AIN = 248 MHz @ -0.5 dBFS 74.4 dBc AIN = 498 MHz @ -0.5 dBFS 72.5 dBc AIN = 1147 MHz @ -0.5 dBFS 70.5 dBc AIN = 1448 MHz @ -0.5 dBFS 72.8 dBc AIN = 125 MHz @ -0.5 dBFS 72.6 dBc AIN = 248 MHz @ -0.5 dBFS 66.5 dBc AIN = 498 MHz @ -0.5 dBFS 63.2 dBc AIN = 1147 MHz @ -0.5 dBFS 61.8 dBc AIN = 1448 MHz @ -0.5 dBFS 63.8 dBc AIN = 125 MHz @ -0.5 dBFS 58.9 dBc AIN = 248 MHz @ -0.5 dBFS 60.4 AIN = 498 MHz @ -0.5 dBFS 60.5 dBc AIN = 1147 MHz @ -0.5 dBFS 56.7 dBc AIN = 1448 MHz @ -0.5 dBFS 55.6 dBc 20 58 dBc Symbol Parameter Conditions ADC12D1800 Typ Lim Units (Limits) Analog Inputs VIN_FSR Analog Differential Input Full Scale Non-Extended Control Mode Range FSR Pin High 740 mVP-P (min) 860 mVP-P (max) 800 Extended Control Mode CIN RIN FM(14:0) = 4000h (default) 800 mVP-P FM(14:0) = 7FFFh 1000 mVP-P Analog Input Capacitance, Non-DES Mode (Note 10, Note 19) Differential 0.02 pF 1.6 pF Analog Input Capacitance, DES Mode (Note 10, Note 19) Differential 0.08 pF Each input pin to ground 2.2 Each input pin to ground Differential Input Resistance 100 pF 91 (min) 109 (max) 1.15 V (min) 1.35 V (max) Common Mode Output VCMO Common Mode Output Voltage ICMO = 100 A TC_VCMO Common Mode Output Voltage Temperature Coefficient ICMO = 100 A VCMO_LVL VCMO input threshold to set DC-coupling Mode CL_VCMO Maximum VCMO Load Capacitance (Note 10) 1.25 38 ppm/C 0.63 V 80 pF 1.15 V (min) 1.35 V (max) Bandgap Reference VBG Bandgap Reference Output Voltage IBG = 100 A TC_VBG Bandgap Reference Voltage Temperature Coefficient IBG = 100 A CL_VBG Maximum Bandgap Reference load Capacitance (Note 10) 1.25 32 ppm/C 80 21 pF www.ti.com ADC12D1800 TABLE 8. Analog Input/Output and Reference Characteristics ADC12D1800 TABLE 9. I-Channel to Q-Channel Characteristics Symbol Parameter Conditions Offset Match X-TALK ADC12D1800 Typ Lim Units (Limits) 2 LSB Positive Full-Scale Match Zero offset selected in Control Register 2 LSB Negative Full-Scale Match Zero offset selected in Control Register 2 LSB Phase Matching (I, Q) fIN = 1.0 GHz <1 Degree Crosstalk from I-channel Aggressor = 867 MHz F.S. (Aggressor) to Q-channel (Victim) Victim = 100 MHz F.S. -70 dB Crosstalk from Q-channel (Aggressor) to I-channel (Victim) -70 dB Aggressor = 867 MHz F.S. Victim = 100 MHz F.S. TABLE 10. Sampling Clock Characteristics Symbol VIN_CLK CIN_CLK RIN_CLK Parameter Differential Sampling Clock Input Level (Note 11) Conditions ADC12D1800 Typ Sine Wave Clock Differential Peak-to-Peak 0.6 Square Wave Clock Differential Peak-to-Peak 0.6 Sampling Clock Input Capacitance Differential (Note 10) Each input to ground Sampling Clock Differential Input Resistance Lim Units (Limits) 0.4 VP-P (min) 2.0 VP-P (max) 0.4 VP-P (min) 2.0 VP-P (max) 0.1 pF 1 pF 100 TABLE 11. AutoSync Feature Characteristics Symbol Parameter Conditions ADC12D1800 Typ Lim Units (Limits) VIN_RCLK Differential RCLK Input Level Differential Peak-to-Peak 360 mVP-P CIN_RCLK RCLK Input Capacitance Differential 0.1 pF 1 pF Each input to ground RIN_RCLK RCLK Differential Input Resistance 100 IIH_RCLK Input Leakage Current; VIN = VA 22 A IIL_RCLK Input Leakage Current; VIN = GND -33 A VO_RCOUT Differential RCOut Output Voltage 360 mV www.ti.com 22 Symbol Parameter Conditions ADC12D1800 Typ Lim Units (Limits) Digital Control Pins (DES, CalDly, CAL, PDI, PDQ, TPM, NDM, FSR, DDRPh, ECE, SCLK, SDI, SCS) VIH Logic High Input Voltage 0.7xVA V (min) VIL Logic Low Input Voltage 0.3xVA V (max) IIH Input Leakage Current; VIN = VA IIL Input Leakage Current; VIN = GND CIN_DIG Digital Control Pin Input Capacitance (Note 10) 0.02 A -0.02 A SCS, SCLK, SDI -17 A PDI, PDQ, ECE -38 A Measured from each control pin to GND 1.5 pF FSR, CalDly, CAL, NDM, TPM, DDRPh, DES Digital Output Pins (Data, DCLKI, DCLKQ, ORI, ORQ) VOD LVDS Differential Output Voltage VBG = Floating, OVS = High 400 mVP-P (min) 800 mVP-P (max) 230 mVP-P (min) 630 mVP-P (max) 630 VBG = Floating, OVS = Low 460 VO DIFF Change in LVDS Output Swing Between Logic Levels VOS Output Offset Voltage VBG = VA, OVS = High 670 mVP-P VBG = VA, OVS = Low 500 mVP-P 1 mV VBG = Floating 0.8 V VBG = VA 1.2 V 1 mV 4 mA 100 VOS Output Offset Voltage Change Between Logic Levels IOS Output Short Circuit Current ZO Differential Output Impedance VOH Logic High Output Level CalRun, IOH = -100 A, (Note 11) SDO, IOH = -400 A (Note 11) 1.65 V VOL Logic Low Output Level CalRun, IOL = 100 A, (Note 11) SDO, IOL = 400 A (Note 11) 0.15 V 1.25 V VIN_CLK VP-P 100 VBG = Floating; D+ and D- connected to 0.8V Differential DCLK Reset Pins (DCLK_RST) VCMI_DRST DCLK_RST Common Mode Input Voltage VID_DRST Differential DCLK_RST Input Voltage RIN_DRST Differential DCLK_RST Input Resistance (Note 10) 23 www.ti.com ADC12D1800 TABLE 12. Digital Control and Output Pin Characteristics ADC12D1800 TABLE 13. Power Supply Characteristics Symbol IA Parameter Analog Supply Current ITC IDR PC Lim Units (Limits) 1345 mA (max) PDI = Low; PDQ = High 730 mA PDI = High; PDQ = Low 730 mA PDI = PDQ = High 15 mA Track-and-Hold and Clock Supply PDI = PDQ = Low Current PDI = Low; PDQ = High 495 mA (max) 295 mA PDI = High; PDQ = Low 295 mA Digital Encoder Supply Current ITOTAL ADC12D1800 Typ PDI = PDQ = Low Output Driver Supply Current IE Conditions Total Supply Current Power Consumption PDI = PDQ = High 4 mA PDI = PDQ = Low 330 mA (max) PDI = Low; PDQ = High 175 mA PDI = High; PDQ = Low 175 mA PDI = PDQ = High 3 mA PDI = PDQ = Low 165 mA (max) PDI = Low; PDQ = High 85 mA PDI = High; PDQ = Low 85 mA PDI = PDQ = High 1 mA 1:2 Demux Mode PDI = PDQ = Low 2335 Non-Demux Mode PDI = PDQ = Low 2200 2481 mA (max) mA (max) 1:2 Demux Mode PDI = PDQ = Low 4.44 PDI = Low; PDQ = High 2.44 PDI = High; PDQ = Low 2.44 W PDI = PDQ = High 43.7 mW 4.18 W (max) 4.7 W (max) W Non-Demux Mode PDI = PDQ = Low TABLE 14. AC Electrical Characteristics Symbol ADC12D1800 Lim Units (Limits) 1.8 GHz Non-DES Mode; LFS = 0b 300 MHz Non-DES Mode; LFS = 1b 150 MHz DES Mode 500 MHz fCLK(min) fCLK fCLK(max) (Note 11) 50 20 % (min) 80 % (max) Parameter Conditions Typ Sampling Clock (CLK) fCLK (max) Maximum Sampling Clock Frequency fCLK (min) Minimum Sampling Clock Frequency Sampling Clock Duty Cycle tCL Sampling Clock Low Time (Note 10) 278 111 ps (min) tCH Sampling Clock High Time (Note 10) 278 111 ps (min) Data Clock (DCLKI, DCLKQ) DCLK Duty Cycle (Note 10) 50 45 % (min) 55 % (max) tSR Setup Time DCLK_RST (Note 11) 45 ps tHR Hold Time DCLK_RST (Note 11) 45 ps www.ti.com 24 tPWR Parameter Pulse Width DCLK_RST Conditions ADC12D1800 Typ Lim (Note 10) 5 tSYNC_DLY DCLK Synchronization Delay 90 Mode (Note 10) 4 0 Mode (Note 10) 5 Units (Limits) Sampling Clock Cycles (min) Sampling Clock Cycles tLHT Differential Low-to-High Transition 10%-to-90%, CL = 2.5 pF Time 200 ps tHLT Differential High-to-Low Transition 10%-to-90%, CL = 2.5 pF Time 200 ps tSU Data-to-DCLK Setup Time 90 Mode (Note 10) 430 ps tH DCLK-to-Data Hold Time 90 Mode (Note 10) 430 ps tOSK DCLK-to-Data Output Skew 50% of DCLK transition to 50% of Data transition (Note 10) 50 ps (max) Sampling CLK+ Rise to Acquisition of Data 1.15 ns 0.2 ps (rms) 3.2 ns Data Input-to-Output tAD Aperture Delay tAJ Aperture Jitter tOD Sampling Clock-to Data Output Delay (in addition to Latency) 50% of Sampling Clock transition to 50% of Data transition tLAT Latency in 1:2 Demux Non-DES Mode (Note 10) DI, DQ Outputs 34 DId, DQd Outputs 35 Latency in 1:4 Demux DES Mode DI Outputs (Note 10) DQ Outputs 34 34.5 DId Outputs 35 DQd Outputs 35.5 Latency in Non-Demux Non-DES DI Outputs Mode (Note 10) DQ Outputs 34 34 Latency in Non-Demux DES Mode DI Outputs (Note 10) DQ Outputs tORR tWU Over Range Recovery Time Wake-Up Time (PDI/PDQ low to Rated Accuracy Conversion) Sampling Clock Cycles 34 34.5 Differential VIN step from 1.2V to 0V to accurate conversion Non-DES Mode (Note 10) DES Mode (Note 10) 25 1 Sampling Clock Cycle 500 ns 1 s www.ti.com ADC12D1800 Symbol ADC12D1800 TABLE 15. Serial Port Interface Symbol fSCLK ADC12D1800 Lim Units (Limits) Serial Clock Low Time 30 ns (min) Serial Clock High Time 30 ns (min) Parameter Serial Clock Frequency Conditions (Note 10) Typ 15 MHz tSSU Serial Data-to-Serial Clock Rising (Note 10) Setup Time 2.5 ns (min) tSH Serial Data-to-Serial Clock Rising (Note 10) Hold Time 1 ns (min) tSCS SCS-to-Serial Clock Rising Setup Time 2.5 ns tHCS SCS-to-Serial Clock Falling Hold Time 1.5 ns tBSU Bus turn-around time 10 ns TABLE 16. Calibration Symbol tCAL Parameter Calibration Cycle Time Conditions ADC12D1800 Typ Lim Non-ECM ECM CSS = 0b Sampling Clock Cycles 5.2*107 ECM CSS = 1b tCAL_L CAL Pin Low Time (Note 10) tCAL_H CAL Pin High Time (Note 10) 1280 1280 tCalDly Calibration delay determined by CalDly Pin (Note 10) CalDly = Low Units (Limits) 224 CalDly = High 230 Sampling Clock Cycles (min) Sampling Clock Cycles (max) Note 1: Absolute Maximum Ratings indicate limits beyond which damage to the device may occur. There is no guarantee of operation at the Absolute Maximum Ratings. Operating Ratings indicate conditions for which the device is functional, but do not guarantee specific performance limits. For guaranteed specifications and test conditions, see the Electrical Characteristics. The guaranteed specifications apply only for the test conditions listed. Some performance characteristics may degrade when the device is not operated under the listed test conditions. Note 2: All voltages are measured with respect to GND = GNDTC = GNDDR = GNDE = 0V, unless otherwise specified. Note 3: When the input voltage at any pin exceeds the power supply limits, i.e. less than GND or greater than VA, the current at that pin should be limited to 50 mA. In addition, over-voltage at a pin must adhere to the maximum voltage limits. Simultaneous over-voltage at multiple pins requires adherence to the maximum package power dissipation limits. These dissipation limits are calculated using JEDEC JESD51-7 thermal model. Higher dissipation may be possible based on specific customer thermal situation and specified package thermal resistances from junction to case. Note 4: Human body model is 100 pF capacitor discharged through a 1.5 k resistor. Machine model is 220 pF discharged through 0. Charged device model simulates a pin slowly acquiring charge (such as from a device sliding down the feeder in an automated assembler) then rapidly being discharged. Note 5: Reflow temperature profiles are different for lead-free and non-lead-free packages. Note 6: The analog inputs, labeled "I/O", are protected as shown below. Input voltage magnitudes beyond the Absolute Maximum Ratings may damage this device. www.ti.com 26 ADC12D1800 30123204 Note 7: To guarantee accuracy, it is required that VA, VTC, VE and VDR be well-bypassed. Each supply pin must be decoupled with separate bypass capacitors. Note 8: Typical figures are at TA = 25C, and represent most likely parametric norms. Test limits are guaranteed to National's AOQL (Average Outgoing Quality Level). Note 9: Calculation of Full-Scale Error for this device assumes that the actual reference voltage is exactly its nominal value. Full-Scale Error for this device, therefore, is a combination of Full-Scale Error and Reference Voltage Error. See Figure 3. For relationship between Gain Error and Full-Scale Error, see Specification Definitions for Gain Error. Note 10: This parameter is guaranteed by design and is not tested in production. Note 11: This parameter is guaranteed by design and/or characterization and is not tested in production. Note 12: The Dynamic Specifications are guaranteed for room to hot ambient temperature only (25C to 85C). Refer to the plots of the dynamic performance vs. temperature in the Typical Performance Plots to see typical performance from cold to room temperature (-40C to 25C). Note 13: These measurements were taken in Extended Control Mode (ECM) with the DES Timing Adjust feature enabled (Addr: 7h). This feature is used to reduce the interleaving timing spur amplitude, which occurs at fs/2-fin, and thereby increase the SFDR, SINAD and ENOB. Note 14: The Fs/2 spur was removed from all the dynamic performance specifications. Note 15: Proper common mode voltage must be maintained to ensure proper output codes, especially during input overdrive. Note 16: The NPR was measured using an Agilent N6030A Arbitrary Waveform Generator (ARB) to generate the input signal. See the Wideband Performance for an example spectrum. The "noise" portion of the signal was created by tones spaced at 500 kHz and the "notch" was a 25 MHz absence of tones centered at 320 MHz. The bandwidth of this equipment is only 500 MHz, so the final reported NPR was extrapolated from the measured NPR as if the entire Nyquist band were occupied with noise. Note 17: The Noise Floor Density was measured for two conditions: the analog input terminated with 50, and in the presence of a 500 MHz wideband noise signal with total power just below the maximum input level to the ADC. In both cases, the spurs at DC, Fs/4 and Fs/2 were not included in the noise floor calculation. The power over the entire Nyquist band (except for the noise signal) was integrated and the average number is reported. Note 18: This rating is intended for d.c.-coupled applications; the voltages listed may be safely applied to VIN+/- for the life-time duty-cycle of the part. Note 19: The differential and pin-to-ground input capacitances are lumped capacitance values from design; they are defined as shown below. 30123295 27 www.ti.com ADC12D1800 13.0 Specification Definitions APERTURE (SAMPLING) DELAY is the amount of delay, measured from the sampling edge of the CLK input, after which the signal present at the input pin is sampled inside the device. APERTURE JITTER (tAJ) is the variation in aperture delay from sample-to-sample. Aperture jitter can be effectively considered as noise at the input. CODE ERROR RATE (CER) is the probability of error and is defined as the probable number of word errors on the ADC output per unit of time divided by the number of words seen in that amount of time. A CER of 10-18 corresponds to a statistical error in one word about every 31.7 years. CLOCK DUTY CYCLE is the ratio of the time that the clock waveform is at a logic high to the total time of one clock period. DIFFERENTIAL NON-LINEARITY (DNL) is the measure of the maximum deviation from the ideal step size of 1 LSB. It is measured at the relevant sample rate, fCLK, with fIN = 1MHz sine wave. EFFECTIVE NUMBER OF BITS (ENOB, or EFFECTIVE BITS) is another method of specifying Signal-to-Noise and Distortion Ratio, or SINAD. ENOB is defined as (SINAD - 1.76) / 6.02 and states that the converter is equivalent to a perfect ADC of this many (ENOB) number of bits. FULL POWER BANDWIDTH (FPBW) is a measure of the frequency at which the reconstructed output fundamental drops to 3 dB below its low frequency value for a full-scale input. GAIN ERROR is the deviation from the ideal slope of the transfer function. It can be calculated from Offset and FullScale Errors. The Positive Gain Error is the Offset Error minus the Positive Full-Scale Error. The Negative Gain Error is the Negative Full-Scale Error minus the Offset Error. The Gain Error is the Negative Full-Scale Error minus the Positive FullScale Error; it is also equal to the Positive Gain Error plus the Negative Gain Error. INTEGRAL NON-LINEARITY (INL) is a measure of worst case deviation of the ADC transfer function from an ideal straight line drawn through the ADC transfer function. The deviation of any given code from this straight line is measured from the center of that code value step. The best fit method is used. INTERMODULATION DISTORTION (IMD) is a measure of the near-in 3rd order distortion products (2f2 - f1, 2f1 - f2) which occur when two tones which are close in frequency (f1, f2) are applied to the ADC input. It is measured from the input tones level to the higher of the two distortion products (dBc) or simply the level of the higher of the two distortion products (dBFS). The input tones are typically -7dBFS. LSB (LEAST SIGNIFICANT BIT) is the bit that has the smallest value or weight of all bits. This value is 30123246 FIGURE 2. LVDS Output Signal Levels LVDS OUTPUT OFFSET VOLTAGE (VOS) is the midpoint between the D+ and D- pins output voltage with respect to ground; i.e., [(VD+) +( VD-)]/2. See Figure 2. MISSING CODES are those output codes that are skipped and will never appear at the ADC outputs. These codes cannot be reached with any input value. MSB (MOST SIGNIFICANT BIT) is the bit that has the largest value or weight. Its value is one half of full scale. NEGATIVE FULL-SCALE ERROR (NFSE) is a measure of how far the first code transition is from the ideal 1/2 LSB above a differential -VIN/2. For the ADC12D1800 the reference voltage is assumed to be ideal, so this error is a combination of full-scale error and reference voltage error. NOISE FLOOR DENSITY is a measure of the power density of the noise floor, expressed in dBFS/Hz and dBm/Hz. '0 dBFS' is defined as the power of a sinusoid which precisely used the full-scale range of the ADC. NOISE POWER RATIO (NPR) is the ratio of the sum of the power outside the notched bins to the sum of the power in an equal number of bins inside the notch, expressed in dB. OFFSET ERROR (VOFF) is a measure of how far the midscale point is from the ideal zero voltage differential input. Offset Error = Actual Input causing average of 8k samples to result in an average code of 2047.5. OUTPUT DELAY (tOD) is the time delay (in addition to Latency) after the rising edge of CLK+ before the data update is present at the output pins. OVER-RANGE RECOVERY TIME is the time required after the differential input voltages goes from 1.2V to 0V for the converter to recover and make a conversion with its rated accuracy. PIPELINE DELAY (LATENCY) is the number of input clock cycles between initiation of conversion and when that data is presented to the output driver stage. The data lags the conversion by the Latency plus the tOD. POSITIVE FULL-SCALE ERROR (PFSE) is a measure of how far the last code transition is from the ideal 1-1/2 LSB below a differential +VIN/2. For the ADC12D1800 the reference voltage is assumed to be ideal, so this error is a combination of full-scale error and reference voltage error. SIGNAL TO NOISE RATIO (SNR) is the ratio, expressed in dB, of the rms value of the fundamental for a single-tone to the rms value of the sum of all other spectral components below one-half the sampling frequency, not including harmonics or DC. SIGNAL TO NOISE PLUS DISTORTION (S/(N+D) or SINAD) is the ratio, expressed in dB, of the rms value of the fundamental for a single-tone to the rms value of all of the other spectral components below half the input clock frequency, including harmonics but excluding DC. VFS / 2N where VFS is the differential full-scale amplitude VIN_FSR as set by the FSR input and "N" is the ADC resolution in bits, which is 12 for the ADC12D1800. LOW VOLTAGE DIFFERENTIAL SIGNALING (LVDS) DIFFERENTIAL OUTPUT VOLTAGE (VID and VOD) is two times the absolute value of the difference between the VD+ and VD- signals; each signal measured with respect to Ground. VOD peak is VOD,P= (VD+ - VD-) and VOD peak-to-peak is VOD,P-P= 2*(VD+ - VD-); for this product, the VOD is measured peak-to-peak. www.ti.com 28 where Af1 is the RMS power of the fundamental (output) frequency and Af2 through Af10 are the RMS power of the first 9 harmonic frequencies in the output spectrum. - Second Harmonic Distortion (2nd Harm) is the difference, expressed in dB, between the RMS power in the input frequency seen at the output and the power in its 2nd harmonic level at the output. - Third Harmonic Distortion (3rd Harm) is the difference expressed in dB between the RMS power in the input frequency seen at the output and the power in its 3rd harmonic level at the output. JA is the thermal resistance between the junction to ambient. JC1 represents the thermal resistance between the die and the exposed metal area on the top of the HSBGA package. JC2 represents the thermal resistance between the die and the center group of balls on the bottom of the HSBGA package. TOTAL HARMONIC DISTORTION (THD) is the ratio expressed in dB, of the rms total of the first nine harmonic levels at the output to the level of the fundamental at the output. THD is calculated as 29 www.ti.com ADC12D1800 SPURIOUS-FREE DYNAMIC RANGE (SFDR) is the difference, expressed in dB, between the rms values of the input signal at the output and the peak spurious signal, where a spurious signal is any signal present in the output spectrum that is not present at the input, excluding DC. ADC12D1800 14.0 Transfer Characteristic 30123222 FIGURE 3. Input / Output Transfer Characteristic www.ti.com 30 ADC12D1800 15.0 Timing Diagrams 30123259 FIGURE 4. Clocking in 1:2 Demux Non-DES Mode* 30123260 FIGURE 5. Clocking in Non-Demux Non-DES Mode* 31 www.ti.com ADC12D1800 30123299 FIGURE 6. Clocking in 1:4 Demux DES Mode* 30123296 FIGURE 7. Clocking in Non-Demux Mode DES Mode* * The timing for these figures is shown for the one input only (I or Q). However, both I- and Q-inputs may be used. For this case, the I-channel functions precisely the same as the Q-channel, with VinI, DCLKI, DId and DI instead of VinQ, DCLKQ, DQd and DQ. Both I- and Q-channel use the same CLK. www.ti.com 32 ADC12D1800 30123220 FIGURE 8. Data Clock Reset Timing (Demux Mode) 30123225 FIGURE 9. Power-on and On-Command Calibration Timing 30123219 FIGURE 10. Serial Interface Timing 33 www.ti.com VA = V DR = VTC = VE = 1.9V, fCLK = 1.8 GHz, fIN = 498 MHz, TA= 25C, I-channel, 1:2 Demux Non-DES Mode (1:1 Demux NonDES Mode has similar performance), unless otherwise stated. For NPR plots, notch width = 25 MHz, fc = 320 MHz. INL vs. CODE (ADC12D1800) INL vs. TEMPERATURE (ADC12D1800) 3 1.0 2 1 INL (LSB) INL (LSB) 0.5 0 0.0 -1 -0.5 -2 -3 0 -1.0 -50 4,095 OUTPUT CODE +INL -INL 0 50 100 TEMPERATURE (C) 30123238 30123240 DNL vs. CODE (ADC12D1800) DNL vs. TEMPERATURE (ADC12D1800) 0.75 0.50 0.50 0.25 DNL (LSB) DNL (LSB) 0.25 0.00 0.00 -0.25 -0.25 -0.50 -0.75 0 -0.50 -50 4,095 OUTPUT CODE +DNL -DNL 0 50 100 TEMPERATURE (C) 30123239 30123241 ENOB vs. TEMPERATURE (ADC12D1800) ENOB vs. SUPPLY VOLTAGE (ADC12D1800) 10 10 9 9 ENOB ENOB ADC12D1800 16.0 Typical Performance Plots 8 7 6 7 NON-DES MODE DES MODE -50 0 50 6 100 TEMPERATURE (C) NON-DES MODE DES MODE 1.6 1.8 2.0 2.2 VA (V) 30123276 www.ti.com 8 30123277 34 10 9 9 ENOB ENOB ENOB vs. INPUT FREQUENCY (ADC12D1800) 10 8 7 6 8 7 NON-DES MODE DES MODE 0 600 1,200 6 1,800 NON-DES MODE DES MODE 0 CLOCK FREQUENCY (MHz) 500 1,000 1,500 INPUT FREQUENCY (MHz) 30123278 30123279 ENOB vs. VCMI (ADC12D1800) SNR vs. TEMPERATURE (ADC12D1800) 62 10 60 SNR (dB) 9 ENOB ADC12D1800 ENOB vs. CLOCK FREQUENCY (ADC12D1800) 8 7 6 0.75 58 56 54 NON-DES MODE DES MODE 1.00 1.25 1.50 52 -50 1.75 NON-DES MODE DES MODE 0 50 100 TEMPERATURE (C) VCMI (V) 30123268 30123242 SNR vs. SUPPLY VOLTAGE (ADC12D1800) SNR vs. CLOCK FREQUENCY (ADC12D1800) 62 62 60 60 58 58 SNR (dB) SNR (dB) NON-DES MODE DES MODE 56 54 54 52 1.6 56 1.8 2.0 52 2.2 NON-DES MODE DES MODE 0 600 1,200 1,800 CLOCK FREQUENCY (MHz) VA (V) 30123269 30123270 35 www.ti.com ADC12D1800 SNR vs. INPUT FREQUENCY (ADC12D1800) THD vs. TEMPERATURE (ADC12D1800) 60 -40 -50 THD (dBc) SNR (dB) 58 56 54 -70 52 50 -60 NON-DES MODE DES MODE 0 500 1,000 -80 -50 1,500 INPUT FREQUENCY (MHz) NON-DES MODE DES MODE 0 50 100 TEMPERATURE (C) 30123271 30123272 THD vs. CLOCK FREQUENCY (ADC12D1800) -40 -40 -50 -50 THD (dBc) THD (dBc) THD vs. SUPPLY VOLTAGE (ADC12D1800) -60 -60 -70 -70 -80 1.6 NON-DES MODE DES MODE 1.8 2.0 -80 2.2 NON-DES MODE DES MODE 0 600 1,200 1,800 CLOCK FREQUENCY (MHz) VA (V) 30123273 30123274 SFDR vs. TEMPERATURE (ADC12D1800) -40 80 -50 70 SFDR (dBc) THD (dBc) THD vs. INPUT FREQUENCY (ADC12D1800) -60 -70 -80 50 NON-DES MODE DES MODE 0 500 1,000 40 -50 1,500 INPUT FREQUENCY (MHz) NON-DES MODE DES MODE 0 50 100 TEMPERATURE (C) 30123275 www.ti.com 60 30123285 36 SFDR vs. CLOCK FREQUENCY (ADC12D1800) 80 80 70 70 SFDR (dBc) SFDR (dBc) ADC12D1800 SFDR vs. SUPPLY VOLTAGE (ADC12D1800) 60 60 50 50 40 1.6 NON-DES MODE DES MODE 1.8 2.0 40 2.2 NON-DES MODE DES MODE 0 600 1,200 1,800 CLOCK FREQUENCY (MHz) VA (V) 30123284 30123282 SFDR vs. INPUT FREQUENCY (ADC12D1800) SPECTRAL RESPONSE AT FIN = 498 MHz (ADC12D1800) 80 0 DES MODE AMPLITUDE (dBFS) SFDR (dBc) 70 60 50 40 NON-DES MODE DES MODE 0 500 1,000 -25 -50 -75 -100 1,500 0 INPUT FREQUENCY (MHz) 600 1,200 1,800 FREQUENCY (MHz) 30123283 30123287 SPECTRAL RESPONSE AT FIN = 498 MHz (ADC12D1800) CROSSTALK vs. SOURCE FREQUENCY (ADC12D1800) -40 NON-DES -25 CROSSTALK (dBFS) AMPLITUDE (dBFS) 0 -50 -75 -100 0 300 600 -50 -60 -70 -80 -90 900 FREQUENCY (MHz) NON-DES MODE 0 1,000 2,000 3,000 AGGRESSOR INPUT FREQUENCY (MHz) 30123288 30123263 37 www.ti.com ADC12D1800 FULL POWER BANDWIDTH (ADC12D1800) POWER CONSUMPTION vs. CLOCK FREQUENCY (ADC12D1800) 0 5.0 SIGNAL GAIN (dB) -3 4.5 POWER (W) -6 -9 -12 -15 NON-DES MODE DES MODE DESIQ MODE 0 1,000 4.0 3.5 3.0 2.5 2,000 2.0 3,000 INPUT FREQUENCY (MHz) DEMUX NON-DEMUX 0 600 1,200 1,800 CLOCK FREQUECY (MHz) 30123248 30123281 NPR vs. RMS NOISE LOADING LEVEL (ADC12D1800) 50 NPR (dB) 45 40 35 30 25 -30 -25 -20 -15 -10 -5 RMS NOISE LOADING LEVEL (dB) 30123214 www.ti.com 38 The ADC12D1800 is a versatile A/D converter with an innovative architecture which permits very high speed operation. The controls available ease the application of the device to circuit solutions. Optimum performance requires adherence to the provisions discussed here and in the Applications Information Section. This section covers an overview, a description of control modes (Extended Control Mode and NonExtended Control Mode), and features. TABLE 17. Non-ECM Pin Summary Pin Name Logic-Low Logic-High Floating Dedicated Control Pins 17.1 OVERVIEW The ADC12D1800 uses a calibrated folding and interpolating architecture that achieves a high Effective Number of Bits (ENOB). The use of folding amplifiers greatly reduces the number of comparators and power consumption. Interpolation reduces the number of front-end amplifiers required, minimizing the load on the input signal and further reducing power requirements. In addition to correcting other non-idealities, on-chip calibration reduces the INL bow often seen with folding architectures. The result is an extremely fast, high performance, low power converter. The analog input signal (which is within the converter's input voltage range) is digitized to twelve bits at speeds of 150 MSPS to 3.6 GSPS, typical. Differential input voltages below negative full-scale will cause the output word to consist of all zeroes. Differential input voltages above positive full-scale will cause the output word to consist of all ones. Either of these conditions at the I- or Q-input will cause the Out-ofRange I-channel or Q-channel output (ORI or ORQ), respectively, to output a logic-high signal. In ECM, an expanded feature set is available via the Serial Interface. The ADC12D1800 builds upon previous architectures, introducing a new DES Mode Timing Adjust, AutoSync feature for multi-chip synchronization and increasing to 15-bit for gain and 12-bit plus sign for offset the independent programmable adjustment for each channel. Each channel has a selectable output demultiplexer which feeds two LVDS buses. If the 1:2 Demux Mode is selected, the output data rate is reduced to half the input sample rate on each bus. When Non-Demux Mode is selected, the output data rate on each channel is at the same rate as the input sample clock and only one 12-bit bus per channel is active. DES Non-DES Mode DES Mode Not valid NDM Demux Mode Non-Demux Mode Not valid DDRPh 0 Mode 90 Mode Not valid CAL See Section 17.2.1.4 Calibration Pin (CAL) Not valid CalDly Shorter delay Longer delay Not valid PDI I-channel active Power Down I-channel Power Down I-channel PDQ Q-channel active Power Down Q-channel Power Down Q-channel TPM Non-Test Pattern Mode Test Pattern Mode Not valid FSR Not allowed Nominal FS input Range Not valid Dual-purpose Control Pins VCMO AC-coupled operation Not allowed DC-coupled operation VBG Not allowed Higher LVDS commonmode voltage Lower LVDS commonmode voltage 17.2.1.1 Dual Edge Sampling Pin (DES) The Dual Edge Sampling (DES) Pin selects whether the ADC12D1800 is in DES Mode (logic-high) or Non-DES Mode (logic-low). DES Mode means that a single analog input is sampled by both I- and Q-channels in a time-interleaved manner. One of the ADCs samples the input signal on the rising sampling clock edge (duty cycle corrected); the other ADC samples the input signal on the falling sampling clock edge (duty cycle corrected). In Non-ECM, only the I-input may be used for DES Mode, a.k.a. "DESI Mode". In ECM, the Q-input may be selected via the DEQ Bit (Addr: 0h, Bit: 6), a.k.a. "DESQ Mode". In ECM, both the I- and Q-inputs maybe selected, a.k.a. "DESIQ Mode". To use this feature in ECM, use the DES bit in the Configuration Register (Addr: 0h; Bit: 7). See Section 17.3.1.4 DES/ Non-DES Mode for more information. 17.2 CONTROL MODES The ADC12D1800 may be operated in one of two control modes: Non-extended Control Mode (Non-ECM) or Extended Control Mode (ECM). In the simpler Non-ECM (also sometimes referred to as Pin Control Mode), the user affects available configuration and control of the device through the control pins. The ECM provides additional configuration and control options through a serial interface and a set of 16 registers, most of which are available to the customer. 17.2.1.2 Non-Demultiplexed Mode Pin (NDM) The Non-Demultiplexed Mode (NDM) Pin selects whether the ADC12D1800 is in Demux Mode (logic-low) or Non-Demux Mode (logic-high). In Non-Demux Mode, the data from the input is produced at the sampled rate at a single 12-bit output bus. In Demux Mode, the data from the input is produced at half the sampled rate at twice the number of output buses. For Non-DES Mode, each I- or Q-channel will produce its data on one or two buses for Non-Demux or Demux Mode, respectively. For DES Mode, the selected channel will produce its data on two or four buses for Non-Demux or Demux Mode, respectively. 17.2.1 Non-Extended Control Mode In Non-extended Control Mode (Non-ECM), the Serial Interface is not active and all available functions are controlled via various pin settings. Non-ECM is selected by setting the ECE Pin to logic-high. Note that, for the control pins, "logichigh" and "logic-low" refer to VA and GND, respectively. Nine dedicated control pins provide a wide range of control for the ADC12D1800 and facilitate its operation. These control pins provide DES Mode selection, Demux Mode selection, DDR Phase selection, execute Calibration, Calibration Delay setting, Power Down I-channel, Power Down Q-channel, Test Pattern Mode selection, and Full-Scale Input Range selection. In addition to this, two dual-purpose control pins provide 39 www.ti.com ADC12D1800 for AC/DC-coupled Mode selection and LVDS output common-mode voltage selection. See Table 17 for a summary. 17.0 Functional Description ADC12D1800 This feature is pin-controlled only and remains active during both Non-ECM and ECM. See Section 17.3.2.5 Demux/Nondemux Mode for more information. to power-down the I-channel. See Section 17.3.4 Power Down for more information. 17.2.1.7 Power Down Q-channel Pin (PDQ) The Power Down Q-channel (PDQ) Pin selects whether the Q-channel is powered down (logic-high) or active (logic-low). This pin functions similarly to the PDI pin, except that it applies to the Q-channel. The PDI and PDQ pins function independently of each other to control whether each I- or Q-channel is powered down or active. This pin remains active in ECM. In ECM, either this pin or the PDQ bit (Addr: 0h; Bit: 10) in the Control Register may be used to power-down the Q-channel. See Section 17.3.4 Power Down for more information. 17.2.1.3 Dual Data Rate Phase Pin (DDRPh) The Dual Data Rate Phase (DDRPh) Pin selects whether the ADC12D1800 is in 0 Mode (logic-low) or 90 Mode (logichigh). The Data is always produced in DDR Mode on the ADC12D1800. The Data may transition either with the DCLK transition (0 Mode) or halfway between DCLK transitions (90 Mode). The DDRPh Pin selects 0 Mode or 90 Mode for both the I-channel: DI- and DId-to-DCLKI phase relationship and for the Q-channel: DQ- and DQd-to-DCLKQ phase relationship. To use this feature in ECM, use the DPS bit in the Configuration Register (Addr: 0h; Bit: 14). See Section 17.3.2.1 DDR Clock Phase for more information. 17.2.1.8 Test Pattern Mode Pin (TPM) The Test Pattern Mode (TPM) Pin selects whether the output of the ADC12D1800 is a test pattern (logic-high) or the converted analog input (logic-low). The ADC12D1800 can provide a test pattern at the four output buses independently of the input signal to aid in system debug. In TPM, the ADC is disengaged and a test pattern generator is connected to the outputs, including ORI and ORQ. SeeSection 17.3.2.6 Test Pattern Mode for more information. 17.2.1.4 Calibration Pin (CAL) The Calibration (CAL) Pin may be used to execute an oncommand calibration or to disable the power-on calibration. The effect of calibration is to maximize the dynamic performance. To initiate an on-command calibration via the CAL pin, bring the CAL pin high for a minimum of tCAL_H input clock cycles after it has been low for a minimum of tCAL_L input clock cycles. Holding the CAL pin high upon power-on will prevent execution of the power-on calibration. In ECM, this pin remains active and is logically OR'd with the CAL bit. To use this feature in ECM, use the CAL bit in the Configuration Register (Addr: 0h; Bit: 15). See Section 17.3.3 Calibration Feature for more information. 17.2.1.9 Full-Scale Input Range Pin (FSR) The Full-Scale Input Range (FSR) Pin sets the full-scale input range for both the I- and Q-channel; for the ADC12D1800, only the logic-high setting is available. The input full-scale range is specified as VIN_FSR in Table 8. In Non-ECM, the fullscale input range for each I- and Q-channel may not be set independently, but it is possible to do so in ECM. The device must be calibrated following a change in FSR to obtain optimal performance. To use this feature in ECM, use the Configuration Registers (Addr: 3h and Bh). See Section 17.3.1 Input Control and Adjust for more information. 17.2.1.5 Calibration Delay Pin (CalDly) The Calibration Delay (CalDly) Pin selects whether a shorter or longer delay time is present, after the application of power, until the start of the power-on calibration. The actual delay time is specified as tCalDly and may be found in Table 16. This feature is pin-controlled only and remains active in ECM. It is recommended to select the desired delay time prior to poweron and not dynamically alter this selection. See Section 17.3.3 Calibration Feature for more information. 17.2.1.10 AC/DC-Coupled Mode Pin (VCMO) The VCMO Pin serves a dual purpose. When functioning as an output, it provides the optimal common-mode voltage for the DC-coupled analog inputs. When functioning as an input, it selects whether the device is AC-coupled (logic-low) or DCcoupled (floating). This pin is always active, in both ECM and Non-ECM. 17.2.1.6 Power Down I-channel Pin (PDI) The Power Down I-channel (PDI) Pin selects whether the Ichannel is powered down (logic-high) or active (logic-low). The digital data output pins, DI and DId, (both positive and negative) are put into a high impedance state when the Ichannel is powered down. Upon return to the active state, the pipeline will contain meaningless information and must be flushed. The supply currents (typicals and limits) are available for the I-channel powered down or active and may be found in Table 13. The device should be recalibrated following a power-cycle of PDI (or PDQ). This pin remains active in ECM. In ECM, either this pin or the PDI bit (Addr: 0h; Bit: 11) in the Control Register may be used www.ti.com 17.2.1.11 LVDS Output Common-mode Pin (VBG) The VBG Pin serves a dual purpose. When functioning as an output, it provides the bandgap reference. When functioning as an input, it selects whether the LVDS output commonmode voltage is higher (logic-high) or lower (floating). The LVDS output common-mode voltage is specified as V OS and may be found in Table 12. This pin is always active, in both ECM and Non-ECM. 40 17.2.2.1 The Serial Interface The ADC12D1800 offers a Serial Interface that allows access to the sixteen control registers within the device. The Serial Interface is a generic 4-wire (optionally 3-wire) synchronous interface that is compatible with SPI type interfaces that are used on many micro-controllers and DSP controllers. Each serial interface access cycle is exactly 24 bits long. A registerread or register-write can be accomplished in one cycle. The signals are defined in such a way that the user can opt to simply join SDI and SDO signals in his system to accomplish a single, bidirectional SDI/O signal. A summary of the pins for this interface may be found in Table 18. See Figure 10 for the timing diagram and Table 15 for timing specification details. Control register contents are retained when the device is put into power-down mode. If this feature is unused, the SCLK, SDI, and SCS pins may be left floating because they each have an internal pull-up. TABLE 19. Command and Data Field Definitions TABLE 18. Serial Interface Pins Pin Name Bit No. C4 SCS (Serial Chip Select bar) 1 Read/Write (R/W) C5 SCLK (Serial Clock) B4 SDI (Serial Data In) 2-3 Reserved Bits must be set to 10b 4-7 A<3:0> 16 registers may be addressed. The order is MSB first 8 X This is a "don't care" bit 9-24 D<15:0> Data written to or read from addressed register A3 SDO (Serial Data Out) SCS: Each assertion (logic-low) of this signal starts a new register access, i.e. the SDI command field must be ready on the following SCLK rising edge. The user is required to deassert this signal after the 24th clock. If the SCS is deasserted before the 24th clock, no data read/write will occur. For a read operation, if the SCS is asserted longer than 24 clocks, the SDO output will hold the D0 bit until SCS is deasserted. For a write operation, if the SCS is asserted longer Name Comments 1b indicates a read operation 0b indicates a write operation The serial data protocol is shown for a read and write operation in Figure 11 and Figure 12, respectively. 30123292 FIGURE 11. Serial Data Protocol - Read Operation 41 www.ti.com ADC12D1800 than 24 clocks, data write will occur normally through the SDI input upon the 24th clock. Setup and hold times, tSCS and tHCS, with respect to the SCLK must be observed. SCS must be toggled in between register access cycles. SCLK: This signal is used to register the input data (SDI) on the rising edge; and to source the output data (SDO) on the falling edge. The user may disable the clock and hold it at logic-low. There is no minimum frequency requirement for SCLK; see fSCLK in Table 15 for more details. SDI: Each register access requires a specific 24-bit pattern at this input, consisting of a command field and a data field. If the SDI and SDO wired are shared (3-wire mode), then during read operations it is necessary to tri-state the master which is driving SDI while the data field is being output by the ADC on SDO. The master must be at TRI-STATE before the falling edge of the 8th clock. If SDI and SDO are not shared (4-wire mode), then this is not necessary. Setup and hold times, tSH and tSSU, with respect to the SCLK must be observed. SDO: This output is normally at TRI-STATE and is driven only when SCS is asserted, the first 8 bits of command data have been received and it is a READ operation. The data is shifted out, MSB first, starting with the 8th clock's falling edge. At the end of the access, when SCS is de-asserted, this output is at TRI-STATE once again. If an invalid address is accessed, the data sourced will consist of all zeroes. If it is a read operation, there will be a bus turnaround time, tBSU, from when the last bit of the command field was read in until the first bit of the data field is written out. Table 19 shows the Serial Interface bit definitions. 17.2.2 Extended Control Mode In Extended Control Mode (ECM), most functions are controlled via the Serial Interface. In addition to this, several of the control pins remain active. See Table 20 for details. ECM is selected by setting the ECE Pin to logic-low. If the ECE Pin is set to logic-high (Non-ECM), then the registers are reset to their default values. So, a simple way to reset the registers is by toggling the ECE pin. Four pins on the ADC12D1800 control the Serial Interface: SCS, SCLK, SDI and SDO. This section covers the Serial Interface. The Register Definitions are located at the end of the datasheet so that they are easy to find, see Section 19.0 Register Definitions. ADC12D1800 30123293 FIGURE 12. Serial Data Protocol - Write Operation www.ti.com 42 TABLE 20. Features and Modes Feature Control Pin Active in ECM Non-ECM ECM Default ECM State Input Control and Adjust AC/DC-coupled Mode Selection Selected via VCMO (Pin C2) Yes Not available N/A Input Full-scale Range Adjust Selected via FSR (Pin Y3) No Selected via the Config Reg (Addr: 3h and Bh) Low FSR value Input Offset Adjust Setting Not available N/A Selected via the Config Reg (Addr: 2h and Ah) Offset = 0 mV DES/Non-DES Mode Selection Selected via DES (Pin V5) No Selected via the DES Bit (Addr: 0h; Bit: 7) Non-DES Mode DES Timing Adjust Not available N/A Selected via the DES Timing Adjust Reg (Addr: 7h) Mid skew offset Sampling Clock Phase Adjust Not available N/A Selected via the Config Reg (Addr: Ch and Dh) tAD adjust disabled Output Control and Adjust Selected via DDRPh DDR Clock Phase Selection (Pin W4) No Selected via the DPS Bit (Addr: 0h; Bit: 14) 0 Mode LVDS Differential Voltage Amplitude Selection Higher amplitude only N/A Selected via the OVS Bit (Addr: 0h; Bit: 13) Higher amplitude LVDS Common-Mode Voltage Amplitude Selection Selected via VBG (Pin B1) Yes Not available N/A Output Formatting Selection Offset Binary only N/A Selected via the 2SC Bit (Addr: 0h; Bit: 4) Offset Binary Test Pattern Mode at Output Selected via TPM (Pin A4) No Selected via the TPM Bit (Addr: 0h; Bit: 12) TPM disabled Demux/Non-Demux Mode Selection Selected via NDM (Pin A5) Yes Not available N/A AutoSync Not available N/A Selected via the Config Reg (Addr: Eh) Master Mode, RCOut1/2 disabled DCLK Reset Not available N/A Selected via the Config Reg (Addr: Eh; Bit 0) DCLK Reset disabled Time Stamp Not available N/A Selected via the TSE Bit (Addr: 0h; Bit: 3) Time Stamp disabled On-command Calibration Selected via CAL (Pin D6) Yes Selected via the CAL Bit (Addr: 0h; Bit: 15) N/A (CAL = 0) Yes Not available N/A Calibration Power-on Calibration Delay Selected via CalDly Selection (Pin V4) Calibration Adjust Not available N/A Selected via the Config Reg (Addr: 4h) tCAL Read/Write Calibration Settings Not available N/A Selected via the SSC Bit (Addr: 4h; Bit: 7) R/W calibration values disabled Power down I-channel Selected via PDI (Pin U3) Yes Selected via the PDI Bit (Addr: 0h; Bit: 11) I-channel operational Power down Q-channel Selected via PDQ (Pin V3) Yes Selected via the PDQ Bit (Addr: 0h; Bit: 10) Q-channel operational Power-Down 43 www.ti.com ADC12D1800 is a summary of the features available, as well as details for the control mode chosen. "N/A" means "Not Applicable." 17.3 FEATURES The ADC12D1800 offers many features to make the device convenient to use in a wide variety of applications. Table 20 ADC12D1800 GHz, the effective sampling rate is doubled to 3.6 GSPS and each of the 4 output buses has an output rate of 900 MSPS. All data is available in parallel. To properly reconstruct the sampled waveform, the four bytes of parallel data that are output with each DCLK must be correctly interleaved. The sampling order is as follows, from the earliest to the latest: DQd, DId, DQ, DI. See Figure 6. If the device is programmed into the Non-Demux DES Mode, two bytes of parallel data are output with each edge of the DCLK in the following sampling order, from the earliest to the latest: DQ, DI. See Figure 7. 17.3.1 Input Control and Adjust There are several features and configurations for the input of the ADC12D1800 so that it may be used in many different applications. This section covers AC/DC-coupled Mode, input full-scale range adjust, input offset adjust, DES/Non-DES Mode, DES Timing Adjust, and sampling clock phase adjust. 17.3.1.1 AC/DC-coupled Mode The analog inputs may be AC or DC-coupled. See Section 17.2.1.10 AC/DC-Coupled Mode Pin (VCMO) for information on how to select the desired mode and Section 18.1.7 DC-coupled Input Signals and Section 18.1.6 AC-coupled Input Signals for applications information. 17.3.1.5 DES Timing Adjust The performance of the ADC12D1800 in DES Mode depends on how well the two channels are interleaved, i.e. that the clock samples either channel with precisely a 50% duty-cycle, each channel has the same offset (nominally code 2047/2048), and each channel has the same full-scale range. The ADC12D1800 includes an automatic clock phase background adjustment in DES Mode to automatically and continuously adjust the clock phase of the I- and Q-channels. In addition to this, the residual fixed timing skew offset may be further manually adjusted, and further reduce timing spurs for specific applications. See the DES Timing Adjust (Addr: 7h). As the DES Timing Adjust is programmed from 0d to 127d, the magnitude of the Fs/2-Fin timing interleaving spur will decrease to a local minimum and then increase again. The default, nominal setting of 64d may or may not coincide with this local minimum. The user may manually skew the global timing to achieve the lowest possible timing interleaving spur. 17.3.1.2 Input Full-Scale Range Adjust The input full-scale range for the ADC12D1800 may be adjusted in ECM. In Non-ECM, the control pin must be set to logic-high; see Section 17.2.1.9 Full-Scale Input Range Pin (FSR). In ECM, the input full-scale range may be adjusted with 15-bits of precision. See VIN_FSR in Table 8 for electrical specification details. Note that the full-scale input range setting in Non-ECM (logic-high only) corresponds to the lowest full-scale input range settings in ECM. It is necessary to execute an on-command calibration following a change of the input full-scale range. See Section 19.0 Register Definitions for information about the registers. 17.3.1.3 Input Offset Adjust The input offset adjust for the ADC12D1800 may be adjusted with 12-bits of precision plus sign via ECM. See Section 19.0 Register Definitions for information about the registers. 17.3.1.6 Sampling Clock Phase Adjust The sampling clock (CLK) phase may be delayed internally to the ADC up to 825 ps in ECM. This feature is intended to help the system designer remove small imbalances in clock distribution traces at the board level when multiple ADCs are used, or to simplify complex system functions such as beam steering for phase array antennas. Additional delay in the clock path also creates additional jitter when using the sampling clock phase adjust. Because the sampling clock phase adjust delays all clocks, including the DCLKs and output data, the user is strongly advised to use the minimal amount of adjustment and verify the net benefit of this feature in his system before relying on it. Using this feature at its maximum setting, for the maximum sampling clock rate, may affect the integrity of the sampling clock on chip. Therefore, it is not recommended to do so. The maximum setting for the coarse adjust is 825ps. The period for the maximum sampling clock rate of is 555ps, so it should not be necessary to exceed this value in any case. 17.3.1.4 DES/Non-DES Mode The ADC12D1800 can operate in Dual-Edge Sampling (DES) or Non-DES Mode. The DES Mode allows for a single analog input to be sampled by both I- and Q-channels. One channel samples the input on the rising edge of the sampling clock and the other samples the same input signal on the falling edge of the sampling clock. A single input is thus sampled twice per clock cycle, resulting in an overall sample rate of twice the sampling clock frequency, e.g. 3.6 GSPS with a 1.8 GHz sampling clock. Since DES Mode uses both I- and Qchannels to process the input signal, both channels must be powered up for the DES Mode to function properly. In Non-ECM, only the I-input may be used for the DES Mode input. See Section 17.2.1.1 Dual Edge Sampling Pin (DES) for information on how to select the DES Mode. In ECM, either the I- or Q-input may be selected by first using the DES bit (Addr: 0h, Bit 7) to select the DES Mode. The DEQ Bit (Addr: 0h, Bit: 6) is used to select the Q-input, but the I-input is used by default. Also, both I- and Q-inputs may be driven externally, i.e. DESIQ Mode, by using the DIQ bit (Addr: 0h, Bit 5). See Section 18.1 THE ANALOG INPUTS for more information about how to drive the ADC in DES Mode. The DESIQ Mode results in the best bandwidth. In general, the bandwidth decreases from Non-DES Mode to DES Mode (specifically, DESI or DESQ) because both channels are sampling off the same input signal and non-ideal effects introduced by interleaving the two channels lower the bandwidth. Driving both I- and Q-channels externally (DESIQ Mode) results in better bandwidth for the DES Mode because each channel is being driven, which reduces routing losses (increases bandwidth). In the DES Mode, the outputs must be carefully interleaved in order to reconstruct the sampled signal. If the device is programmed into the 1:4 Demux DES Mode, the data is effectively demultiplexed by 1:4. If the sampling clock is 1.8 www.ti.com 17.3.2 Output Control and Adjust There are several features and configurations for the output of the ADC12D1800 so that it may be used in many different applications. This section covers DDR clock phase, LVDS output differential and common-mode voltage, output formatting, Demux/Non-demux Mode, Test Pattern Mode, and Time Stamp. 17.3.2.1 DDR Clock Phase The ADC12D1800 output data is always delivered in Double Data Rate (DDR). With DDR, the DCLK frequency is half the data rate and data is sent to the outputs on both edges of DCLK; see Figure 13. The DCLK-to-Data phase relationship may be either 0 or 90. For 0 Mode, the Data transitions on each edge of the DCLK. Any offset from this timing is tOSK; see Table 14 for details. For 90 Mode, the DCLK transitions in the middle of each Data cell. Setup and hold times for this 44 pattern generator is connected to the outputs, including ORI and ORQ. The test pattern output is the same in DES Mode or Non-DES Mode. Each port is given a unique 12-bit word, alternating between 1's and 0's. When the part is programmed into the Demux Mode, the test pattern's order is described in Table 21. If the I- or Q-channel is powered down, the test pattern will not be output for that channel. TABLE 21. Test Pattern by Output Port in Demux Mode Time 30123294 FIGURE 13. DDR DCLK-to-Data Phase Relationship 17.3.2.2 LVDS Output Differential Voltage The ADC12D1800 is available with a selectable higher or lower LVDS output differential voltage. This parameter is VOD and may be found in Table 12. The desired voltage may be selected via the OVS Bit (Addr: 0h, Bit 13). For many applications, in which the LVDS outputs are very close to an FPGA on the same board, for example, the lower setting is sufficient for good performance; this will also reduce the possibility for EMI from the LVDS outputs to other signals on the board. See Section 19.0 Register Definitions for more information. Qd Id Q I ORQ ORI Comments T0 000h 004h 008h 010h 0b 0b T1 FFFh FFBh FF7h FEFh 1b 1b T2 000h 004h 008h 010h 0b 0b T3 FFFh FFBh FF7h FEFh 1b 1b T4 000h 004h 008h 010h 0b 0b T5 000h 004h 008h 010h 0b 0b T6 FFFh FFBh FF7h FEFh 1b 1b T7 000h 004h 008h 010h 0b 0b T8 FFFh FFBh FF7h FEFh 1b 1b T9 000h 004h 008h 010h 0b 0b T10 000h 004h 008h 010h 0b 0b T11 FFFh FFBh FF7h FEFh 1b 1b T12 000h 004h 008h 010h 0b 0b T13 ... ... ... ... ... ... Pattern Sequence n Pattern Sequence n+1 Pattern Sequence n+2 When the part is programmed into the Non-Demux Mode, the test pattern's order is described in Table 22. TABLE 22. Test Pattern by Output Port in Non-Demux Mode 17.3.2.3 LVDS Output Common-Mode Voltage The ADC12D1800 is available with a selectable higher or lower LVDS output common-mode voltage. This parameter is VOS and may be found in Table 12. See Section 17.2.1.11 LVDS Output Common-mode Pin (VBG) for information on how to select the desired voltage. 17.3.2.4 Output Formatting The formatting at the digital data outputs may be either offset binary or two's complement. The default formatting is offset binary, but two's complement may be selected via the 2SC Bit (Addr: 0h, Bit 4); see Section 19.0 Register Definitions for more information. 17.3.2.5 Demux/Non-demux Mode The ADC12D1800 may be in one of two demultiplex modes: Demux Mode or Non-Demux Mode (also sometimes referred to as 1:1 Demux Mode). In Non-Demux Mode, the data from the input is simply output at the sampling rate on one 12-bit bus. In Demux Mode, the data from the input is output at half the sampling rate, on twice the number of buses. Demux/NonDemux Mode may only be selected by the NDM pin; see Section 17.2.1.2 Non-Demultiplexed Mode Pin (NDM). In Non-DES Mode, the output data from each channel may be demultiplexed by a factor of 1:2 (1:2 Demux Non-DES Mode) or not demultiplexed (Non-Demux Non-DES Mode). In DES Mode, the output data from both channels interleaved may be demultiplexed (1:4 Demux DES Mode) or not demultiplexed (Non-Demux DES Mode). Time Q I ORQ ORI T0 000h 004h 0b 0b T1 000h 004h 0b 0b T2 FFFh FFBh 1b 1b T3 FFFh FFBh 1b 1b T4 000h 004h 0b 0b T5 FFFh FFBh 1b 1b T6 000h 004h 0b 0b T7 FFFh FFBh 1b 1b T8 FFFh FFBh 1b 1b T9 FFFh FFBh 1b 1b T10 000h 004h 0b 0b T11 000h 004h 0b 0b T12 FFFh FFBh 1b 1b T13 FFFh FFBh 1b 1b T14 ... ... ... ... Comments Pattern Sequence n Pattern Sequence n+1 17.3.2.7 Time Stamp The Time Stamp feature enables the user to capture the timing of an external trigger event, relative to the sampled signal. When enabled via the TSE Bit (Addr: 0h; Bit: 3), the LSB of the digital outputs (DQd, DQ, DId, DI) captures the trigger information. In effect, the 12-bit converter becomes an 11-bit converter and the LSB acts as a 1-bit converter with the same latency as the 11-bit converter. The trigger should be applied to the DCLK_RST input. It may be asynchronous to the ADC sampling clock. 17.3.2.6 Test Pattern Mode The ADC12D1800 can provide a test pattern at the four output buses independently of the input signal to aid in system debug. In Test Pattern Mode, the ADC is disengaged and a test 45 www.ti.com ADC12D1800 transition, tSU and tH, may also be found in Table 14. The DCLK-to-Data phase relationship may be selected via the DDRPh Pin in Non-ECM (see Section 17.2.1.3 Dual Data Rate Phase Pin (DDRPh)) or the DPS bit in the Configuration Register (Addr: 0h; Bit: 14) in ECM. ADC12D1800 device is powered-on, it can execute a calibration even though the CAL Pin/Bit remains logic-low. The power-on calibration will be not be performed if the CAL pin is logic-high at power-on. In this case, the calibration cycle will not begin until the on-command calibration conditions are met. The ADC12D1800 will function with the CAL pin held high at power up, but no calibration will be done and performance will be impaired. If it is necessary to toggle the CalDly Pin during the system power up sequence, then the CAL Pin/Bit must be set to logichigh before the toggling and afterwards for 109 Sampling Clock cycles. This will prevent the power-on calibration, so an on-command calibration must be executed or the performance will be impaired. 17.3.3 Calibration Feature The ADC12D1800 calibration must be run to achieve specified performance. The calibration procedure is exactly the same regardless of how it was initiated or when it is run. Calibration trims the analog input differential termination resistors, the CLK input resistor, and sets internal bias currents which affect the linearity of the converter. This minimizes fullscale error, offset error, DNL and INL, which results in the maximum dynamic performance, as measured by: SNR, THD, SINAD (SNDR) and ENOB. 17.3.3.1 Calibration Control Pins and Bits Table 23 is a summary of the pins and bits used for calibration. See Section 9.0 Ball Descriptions and Equivalent Circuits for complete pin information and Figure 9 for the timing diagram. 17.3.3.4 On-command Calibration In addition to the power-on calibration, it is recommended to execute an on-command calibration whenever the settings or conditions to the device are altered significantly, in order to obtain optimal parametric performance. Some examples include: changing the FSR via ECM, power-cycling either channel, and switching into or out of DES Mode. For best performance, it is also recommended that an on-command calibration be run 20 seconds or more after application of power and whenever the operating temperature changes significantly, relative to the specific system performance requirements. Due to the nature of the calibration feature, it is recommended to avoid unnecessary activities on the device while the calibration is taking place. For example, do not read or write to the Serial Interface or use the DCLK Reset feature while calibrating the ADC. Doing so will impair the performance of the device until it is re-calibrated correctly. Also, it is recommended to not apply a strong narrow-band signal to the analog inputs during calibration because this may impair the accuracy of the calibration; broad spectrum noise is acceptable. TABLE 23. Calibration Pins Pin (Bit) Name Function D6 (Addr: 0h; Bit 15) CAL (Calibration) Initiate calibration V4 CalDly (Calibration Delay) Select power-on calibration delay (Addr: 4h) Calibration Adjust B5 C1/D2 C3/D3 CalRun (Calibration Running) Adjust calibration sequence Indicates while calibration is running Rtrim+/External resistor used to (Input termination calibrate analog and trim resistor) CLK inputs Rext+/(External Reference resistor) External resistor used to calibrate internal linearity 17.3.3.5 Calibration Adjust The sequence of the calibration event itself may be adjusted. This feature can be used if a shorter calibration time than the default is required; see tCAL in Table 16. However, the performance of the device, when using this feature is not guaranteed. The calibration sequence may be adjusted via CSS (Addr: 4h, Bit 14). The default setting of CSS = 1b executes both RIN and RIN_CLK Calibration (using Rtrim) and internal linearity Calibration (using Rext). Executing a calibration with CSS = 0b executes only the internal linearity Calibration. The first time that Calibration is executed, it must be with CSS = 1b to trim RIN and RIN_CLK. However, once the device is at its operating temperature and RIN has been trimmed at least one time, it will not drift significantly. To save time in subsequent calibrations, trimming RIN and RIN_CLK may be skipped, i.e. by setting CSS = 0b. 17.3.3.2 How to Execute a Calibration Calibration may be initiated by holding the CAL pin low for at least tCAL_L clock cycles, and then holding it high for at least another tCAL_H clock cycles, as defined in Table 16. The minimum tCAL_L and tCAL_H input clock cycle sequences are required to ensure that random noise does not cause a calibration to begin when it is not desired. The time taken by the calibration procedure is specified as tCAL. The CAL Pin is active in both ECM and Non-ECM. However, in ECM, the CAL Pin is logically OR'd with the CAL Bit, so both the pin and bit are required to be set low before executing another calibration via either pin or bit. 17.3.3.3 Power-on Calibration For standard operation, power-on calibration begins after a time delay following the application of power, as determined by the setting of the CalDly Pin and measured by tCalDly (see Table 16). This delay allows the power supply to come up and stabilize before the power-on calibration takes place. The best setting (short or long) of the CalDly Pin depends upon the settling time of the power supply. It is strongly recommended to set CalDly Pin (to either logichigh or logic-low) before powering the device on since this pin affects the power-on calibration timing. This may be accomplished by setting CalDly via an external 1k resistor connected to GND or VA. If the CalDly Pin is toggled while the www.ti.com 17.3.3.6 Read/Write Calibration Settings When the ADC performs a calibration, the calibration constants are stored in an array which is accessible via the Calibration Values register (Addr: 5h). To save the time which it takes to execute a calibration, tCAL, or to allow for re-use of a previous calibration result, these values can be read from and written to the register at a later time. For example, if an application requires the same input impedance, RIN, this feature can be used to load a previously determined set of values. For the calibration values to be valid, the ADC must be operating under the same conditions, including tempera- 46 The calibration cycle will continue when either or both channels are powered back up, but the calibration will be compromised due to the incomplete settling of bias currents directly after power up. Therefore, a new calibration should be executed upon powering the ADC12D1800 back up. In general, the ADC12D1800 should be recalibrated when either or both channels are powered back up, or after one channel is powered down. For best results, this should be done after the device has stabilized to its operating temperature. 17.3.3.8 Calibration and the Digital Outputs During calibration, the digital outputs (including DI, DId, DQ, DQd and OR) are set logic-low, to reduce noise. The DCLK runs continuously during calibration. After the calibration is completed and the CalRun signal is logic-low, it takes an additional 60 Sampling Clock cycles before the output of the ADC12D1800 is valid converted data from the analog inputs. This is the time it takes for the pipeline to flush, as well as for other internal processes. 17.3.4 Power Down On the ADC12D1800, the I- and Q-channels may be powered down individually. This may be accomplished via the control pins, PDI and PDQ, or via ECM. In ECM, the PDI and PDQ pins are logically OR'd with the Control Register setting. See Section 17.2.1.6 Power Down I-channel Pin (PDI) andSection 17.2.1.7 Power Down Q-channel Pin (PDQ) for more information. 17.3.3.7 Calibration and Power-Down If PDI and PDQ are simultaneously asserted during a calibration cycle, the ADC12D1800 will immediately power down. 47 www.ti.com ADC12D1800 ture, at which the calibration values were originally determined by the ADC. To read calibration values from the SPI, do the following: 1. Set ADC to desired operating conditions. 2. Set SSC (Addr: 4h, Bit 7) to 1. 3. Power down both I- and Q-channels. 4. Read exactly 240 times the Calibration Values register (Addr: 5h). The register values are R0, R1, R2... R239. The contents of R<239:0> should be stored. 5. Power up I- and Q-channels to original setting. 6. Set SSC (Addr: 4h, Bit 7) to 0. 7. Continue with normal operation. To write calibration values to the SPI, do the following: 1. Set ADC to operating conditions at which Calibration Values were previously read. 2. Set SSC (Addr: 4h, Bit 7) to 1. 3. Power down both I- and Q-channels. 4. Write exactly 240 times the Calibration Values register (Addr: 5h). The registers should be written R0, R1... R239. 5. Make two additional dummy writes of 0000h. 6. Power up I- and Q-channels to original setting. 7. Set SSC (Addr: 4h, Bit 7) to 0. 8. Continue with normal operation. ADC12D1800 18.1.2 Driving the ADC in DES Mode The ADC12D1800 can be configured as either a 2-channel, 1.8 GSPS device (Non-DES Mode) or a 1-channel 3.6GSPS device (DES Mode). When the device is configured in DES Mode, there is a choice for with which input to drive the singlechannel ADC. These are the 3 options: DES - externally driving the I-channel input only. This is the default selection when the ADC is configured in DES Mode. It may also be referred to as "DESI" for added clarity. DESQ - externally driving the Q-channel input only. DESIQ - externally driving both the I- and Q-channel inputs. VinI+ and VinQ+ should be driven with the exact same signal. VinI- and VinQ- should be driven with the exact same signal, which is the differential complement to the one driving VinI+ and VinQ+. The input impedance for each I- and Q-input is 100 differential (or 50 single-ended), so the trace to each VinI+, VinI-, VinQ+, and VinQ- should always be 50 single-ended. If a single I- or Q-input is being driven, then that input will present a 100 differential load. For example, if a 50 single-ended source is driving the ADC, then a 1:2 balun will transform the impedance to 100 differential. However, if the ADC is being driven in DESIQ Mode, then the 100 differential impedance from the I-input will appear in parallel with the Q-input for a composite load of 50 differential and a 1:1 balun would be appropriate. See Figure 14 for an example circuit driving the ADC in DESIQ Mode. A recommended part selection is using the Mini-Circuits TC1-1-13MA+ balun with Ccouple = 0.22F. 18.0 Applications Information 18.1 THE ANALOG INPUTS The ADC12D1800 will continuously convert any signal which is present at the analog inputs, as long as a CLK signal is also provided to the device. This section covers important aspects related to the analog inputs including: acquiring the input, driving the ADC in DES Mode, the reference voltage and FSR, out-of-range indication, AC/DC-coupled signals, and singleended input signals. 18.1.1 Acquiring the Input Data is acquired at the rising edge of CLK+ in Non-DES Mode and both the falling and rising edges of CLK+ in DES Mode. The digital equivalent of that data is available at the digital outputs a constant number of sampling clock cycles later for the DI, DQ, DId and DQd output buses, a.k.a. Latency, depending on the demultiplex mode which is selected. See tLAT in Table 14. In addition to the Latency, there is a constant output delay, t OD, before the data is available at the outputs. See tOD in Table 14 and the Timing Diagrams. The output latency versus Demux/Non-Demux Mode is shown in Table 24 and Table 25, respectively. For DES Mode, note that the I- and Q-channel inputs are available in ECM, but only the I-channel input is available in Non-ECM. TABLE 24. Output Latency in Demux Mode Data Non-DES Mode DES Mode Q-input* I-input I-input sampled Q-input sampled I-input sampled with rise of CLK, with rise of CLK, with rise of CLK, 34 cycles earlier 34 cycles earlier 34 cycles earlier DI Q-input sampled I-input sampled Q-input sampled with fall of CLK, with fall of CLK, DQ with rise of CLK, 34.5 cycles 34.5 cycles 34 cycles earlier earlier earlier I-input sampled Q-input sampled I-input sampled DId with rise of CLK, with rise of CLK, with rise of CLK, 35 cycles earlier 35 cycles earlier 35 cycles earlier Q-input sampled I-input sampled Q-input sampled with fall of CLK, with fall of CLK, DQd with rise of CLK, 35.5 cycles 35.5 cycles 35 cycles earlier earlier earlier 30123213 FIGURE 14. Driving DESIQ Mode TABLE 25. Output Latency in Non-Demux Mode Data Non-DES Mode DI DES Mode Q-input* In the case that only one channel is used in Non-DES Mode or that the ADC is driven in DESI or DESQ Mode, the unused analog input should be terminated to reduce any noise coupling into the ADC. See Table 26 for details. I-input I-input sampled Q-input sampled I-input sampled with rise of CLK, with rise of CLK, with rise of CLK, 34 cycles earlier 34 cycles earlier 34 cycles earlier TABLE 26. Unused Analog Input Recommended Termination Q-input sampled I-input sampled Q-input sampled with rise of CLK, with rise of CLK, DQ with rise of CLK, 34.5 cycles 34.5 cycles 34 cycles earlier earlier earlier DId No output; high impedance. DQd No output; high impedance. Mode *Available in ECM only. www.ti.com 48 Power Down Coupling Recommended Termination Non-DES Yes AC/DC Tie Unused+ and Unused- to Vbg DES/ No Non-DES DC Tie Unused+ and Unused- to Vbg DES/ No Non-DES AC Tie Unused+ to Unused- nected to AC ground, e.g. through capacitors to ground . Do not connect an unused analog input directly to ground. 18.1.4 Out-Of-Range Indication Differential input signals are digitized to 12 bits, based on the full-scale range. Signal excursions beyond the full-scale range, i.e. greater than +VIN_FSR/2 or less than -VIN_FSR/2, will be clipped at the output. An input signal which is above the FSR will result in all 1's at the output and an input signal which is below the FSR will result in all 0's at the output. When the conversion result is clipped for the I-channel input, the Outof-Range I-channel (ORI) output is activated such that ORI+ goes high and ORI- goes low while the signal is out of range. This output is active as long as accurate data on either or both of the buses would be outside the range of 000h to FFFh. The Q-channel has a separate ORQ which functions similarly. 18.1.7 DC-coupled Input Signals In DC-coupled Mode, the ADC12D1800 differential inputs must have the correct common-mode voltage. This voltage is provided by the device itself at the VCMO output pin. It is recommended to use this voltage because the VCMO output potential will change with temperature and the common-mode voltage of the driving device should track this change. Fullscale distortion performance falls off as the input common mode voltage deviates from VCMO. Therefore, it is recommended to keep the input common-mode voltage within 100 mV of VCMO (typical), although this range may be extended to 150 mV (maximum). See VCMI in Table 8 and ENOB vs. VCMI in Section 16.0 Typical Performance Plots . Performance in AC- and DC-coupled Mode are similar, provided that the input common mode voltage at both analog inputs remains within 100 mV of VCMO. 30123244 FIGURE 15. AC-coupled Differential Input The analog inputs for the ADC12D1800 are internally buffered, which simplifies the task of driving these inputs and the RC pole which is generally used at sampling ADC inputs is not required. If the user desires to place an amplifier circuit before the ADC, care should be taken to choose an amplifier with adequate noise and distortion performance, and adequate gain at the frequencies used for the application. 18.1.5 Maximum Input Range The recommended operating and absolute maximum input range may be found in Section 11.0 Operating Ratings and Section 10.0 Absolute Maximum Ratings, respectively. Under the stated allowed operating conditions, each Vin+ and Vininput pin may be operated in the range from 0V to 2.15V if the input is a continuous 100% duty cycle signal and from 0V to 2.5V if the input is a 10% duty cycle signal. The absolute maximum input range for Vin+ and Vin- is from -0.15V to 2.5V. These limits apply only for input signals for which the input common mode voltage is properly maintained. 18.1.8 Single-Ended Input Signals The analog inputs of the ADC12D1800 are not designed to accept single-ended signals. The best way to handle singleended signals is to first convert them to differential signals before presenting them to the ADC. The easiest way to accomplish single-ended to differential signal conversion is with an appropriate balun-transformer, as shown in Figure 16. 18.1.6 AC-coupled Input Signals The ADC12D1800 analog inputs require a precise commonmode voltage. This voltage is generated on-chip when ACcoupling Mode is selected. See Section 17.2.1.10 AC/DCCoupled Mode Pin (VCMO) for more information about how to select AC-coupled Mode. In AC-coupled Mode, the analog inputs must of course be ACcoupled. For an ADC12D1800 used in a typical application, this may be accomplished by on-board capacitors, as shown in Figure 15. For the ADC12D1800RB, the SMA inputs on the Reference Board are directly connected to the analog inputs on the ADC12D1800, so this may be accomplished by DC blocks (included with the hardware kit). When the AC-coupled Mode is selected, an analog input channel that is not used (e.g. in DES Mode) should be con- 30123243 FIGURE 16. Single-Ended to Differential Conversion Using a Balun When selecting a balun, it is important to understand the input architecture of the ADC. The impedance of the analog source should be matched to the ADC12D1800's on-chip 100 dif- 49 www.ti.com ADC12D1800 18.1.3 FSR and the Reference Voltage The full-scale analog differential input range (VIN_FSR) of the ADC12D1800 is derived from an internal bandgap reference. In Non-ECM, this full-scale range must be set by the logichigh setting of the FSR Pin; see Section 17.2.1.9 Full-Scale Input Range Pin (FSR). The FSR Pin operates on both I- and Q-channels. In ECM, the full-scale range may be independently set for each channel via Addr:3h and Bh with 15 bits of precision; see Section 19.0 Register Definitions. The best SNR is obtained with a higher full-scale input range, but better distortion and SFDR are obtained with a lower full-scale input range. It is not possible to use an external analog reference voltage to modify the full-scale range, and this adjustment should only be done digitally, as described. A buffered version of the internal bandgap reference voltage is made available at the VBG Pin for the user. The VBG pin can drive a load of up to 80 pF and source or sink up to 100 A. It should be buffered if more current than this is required. This pin remains as a constant reference voltage regardless of what full-scale range is selected and may be used for a system reference. VBG is a dual-purpose pin and it may also be used to select a higher LVDS output common-mode voltage; see Section 17.2.1.11 LVDS Output Common-mode Pin (VBG). ADC12D1800 ferential input termination resistor. The range of this termination resistor is specified as RIN in Table 8. proved ADC clocking, especially in the Dual-Edge Sampling (DES) Mode. 18.2 THE CLOCK INPUTS The ADC12D1800 has a differential clock input, CLK+ and CLK-, which must be driven with an AC-coupled, differential clock signal. This provides the level shifting necessary to allow for the clock to be driven with LVDS, PECL, LVPECL, or CML levels. The clock inputs are internally terminated to 100 differential and self-biased. This section covers coupling, frequency range, level, duty-cycle, jitter, and layout considerations. 18.2.5 CLK Jitter High speed, high performance ADCs such as the ADC12D1800 require a very stable input clock signal with minimum phase noise or jitter. ADC jitter requirements are defined by the ADC resolution (number of bits), maximum ADC input frequency and the input signal amplitude relative to the ADC input full scale range. The maximum jitter (the sum of the jitter from all sources) allowed to prevent a jitter-induced reduction in SNR is found to be tJ(MAX) = ( VIN(P-P)/ VFSR) x (1/(2(N+1) x x fIN)) 18.2.1 CLK Coupling The clock inputs of the ADC12D1800 must be capacitively coupled to the clock pins as indicated in Figure 17. where tJ(MAX) is the rms total of all jitter sources in seconds, VIN(P-P) is the peak-to-peak analog input signal, VFSR is the full-scale range of the ADC, "N" is the ADC resolution in bits and fIN is the maximum input frequency, in Hertz, at the ADC analog input. tJ(MAX) is the square root of the sum of the squares (RSS) sum of the jitter from all sources, including: the ADC input clock, system, input signals and the ADC itself. Since the effective jitter added by the ADC is beyond user control, it is recommended to keep the sum of all other externally added jitter to a minimum. 18.2.6 CLK Layout The ADC12D1800 clock input is internally terminated with a trimmed 100 resistor. The differential input clock line pair should have a characteristic impedance of 100 and (when using a balun), be terminated at the clock source in that (100) characteristic impedance. It is good practice to keep the ADC input clock line as short as possible, tightly coupled, keep it well away from any other signals, and treat it as a transmission line. Otherwise, other signals can introduce jitter into the input clock signal. Also, the clock signal can introduce noise into the analog path if it is not properly isolated. 30123247 FIGURE 17. Differential Input Clock Connection The choice of capacitor value will depend on the clock frequency, capacitor component characteristics and other system economic factors. For example, on the ADC12D1800RB, the capacitors have the value Ccouple = 4.7 nF which yields a high pass cutoff frequency, fc = 677.2 kHz. 18.2.2 CLK Frequency Although the ADC12D1800 is tested and its performance is guaranteed with a differential 1.8 GHz sampling clock, it will typically function well over the input clock frequency range; see fCLK(min) and fCLK(max) in Table 14. Operation up to fCLK (max) is possible if the maximum ambient temperatures indicated are not exceeded. Operating at sample rates above fCLK(max) for the maximum ambient temperature may result in reduced device reliability and product lifetime. This is due to the fact that higher sample rates results in higher power consumption and die temperatures. If fCLK < 300 MHz, enable LFS in the Control Register (Addr: 0h, Bit 8). 18.3 THE LVDS OUTPUTS The Data, ORI, ORQ, DCLKI and DCLKQ outputs are LVDS. The electrical specifications of the LVDS outputs are compatible with typical LVDS receivers available on ASIC and FPGA chips; but they are not IEEE or ANSI communications standards compliant due to the low +1.9V supply used on this chip. These outputs should be terminated with a 100 differential resistor placed as closely to the receiver as possible. If the 100 differential resistor is built in to the receiver, then an externally placed resistor is not necessary. This section covers common-mode and differential voltage, and data rate. 18.2.3 CLK Level The input clock amplitude is specified as VIN_CLK in Table 10. Input clock amplitudes above the max VIN_CLK may result in increased input offset voltage. This would cause the converter to produce an output code other than the expected 2047/2048 when both input pins are at the same potential. Insufficient input clock levels will result in poor dynamic performance. Both of these results may be avoided by keeping the clock input amplitude within the specified limits of VIN_CLK. 18.3.1 Common-mode and Differential Voltage The LVDS outputs have selectable common-mode and differential voltage, VOS and VOD; see Table 12. See Section 17.3.2 Output Control and Adjust for more information. Selecting the higher VOS will also increase VOD slightly. The differential voltage, VOD, may be selected for the higher or lower value. For short LVDS lines and low noise systems, satisfactory performance may be realized with the lower VOD. This will also result in lower power consumption. If the LVDS lines are long and/or the system in which the ADC12D1800 is used is noisy, it may be necessary to select the higher VOD. 18.2.4 CLK Duty Cycle The duty cycle of the input clock signal can affect the performance of any A/D converter. The ADC12D1800 features a duty cycle clock correction circuit which can maintain performance over the 20%-to-80% specified clock duty-cycle range. This feature is enabled by default and provides im- www.ti.com 18.3.2 Output Data Rate The data is produced at the output at the same rate it is sampled at the input. The minimum recommended input clock rate 50 If the AutoSync or DCLK Reset feature is not used, see Table 27 for recommendations about terminating unused pins. TABLE 27. Unused AutoSync and DCLK Reset Pin Recommendation 18.3.3 Terminating Unused LVDS Output Pins If the ADC is used in Non-Demux Mode, then only the DI and DQ data outputs will have valid data present on them. The DId and DQd data outputs may be left not connected; if unused, they are internally at TRI-STATE. Similarly, if the Q-channel is powered-down (i.e. PDQ is logichigh), the DQ data output pins, DCLKQ and ORQ may be left not connected. Pin(s) Unused termination RCLK+/- Do not connect. RCOUT1+/- Do not connect. RCOUT2+/- Do not connect. DCLK_RST+ Connect to GND via 1k resistor. DCLK_RST- Connect to VA via 1k resistor. 18.4.1 AutoSync Feature AutoSync is a feature which continuously synchronizes the outputs of multiple ADC12D1800s in a system. It may be used to synchronize the DCLK and data outputs of one or more Slave ADC12D1800s to one Master ADC12D1800. Several advantages of this feature include: no special synchronization pulse required, any upset in synchronization is recovered upon the next DCLK cycle, and the Master/Slave ADC12D1800s may be arranged as a binary tree so that any upset will quickly propagate out of the system. An example system is shown below in Figure 18 which consists of one Master ADC and two Slave ADCs. For simplicity, only one DCLK is shown; in reality, there is DCLKI and DCLKQ, but they are always in phase with one another. 18.4 SYNCHRONIZING MULTIPLE ADC12D1800S IN A SYSTEM The ADC12D1800 has two features to assist the user with synchronizing multiple ADCs in a system; AutoSync and DCLK Reset. The AutoSync feature and designates one ADC12D1800 as the Master ADC and other ADC12D1800s in the system as Slave ADCs. The DCLK Reset feature performs the same function as the AutoSync feature, but is the first generation solution to synchronizing multiple ADCs in a system; it is disabled by default. For the application in which there are multiple Master and Slave ADC12D1800s in a system, AutoSync may be used to synchronize the Slave ADC12D1800(s) to each respective Master ADC12D1800 and the DCLK Reset may be used to synchronize the Master ADC12D1800s to each other. 30123203 FIGURE 18. AutoSync Example In order to synchronize the DCLK (and Data) outputs of multiple ADCs, the DCLKs must transition at the same time, as well as be in phase with one another. The DCLK at each ADC is generated from the CLK after some latency, plus tOD minus tAD. Therefore, in order for the DCLKs to transition at the same time, the CLK signal must reach each ADC at the same time. To tune out any differences in the CLK path to each ADC, the tAD adjust feature may be used. However, using the tAD adjust feature will also affect when the DCLK is produced at the output. If the device is in Demux Mode, then there are four possible phases which each DCLK may be generated on because the typical CLK = 1GHz and DCLK = 250 MHz for this case. The RCLK signal controls the phase of the DCLK, so that each Slave DCLK is on the same phase as the Master DCLK. The AutoSync feature may only be used via the Control Registers. For more information, see AN-2132. 18.4.2 DCLK Reset Feature The DCLK reset feature is available via ECM, but it is disabled by default. DCLKI and DCLKQ are always synchronized, by design, and do not require a pulse from DCLK_RST to become synchronized. The DCLK_RST signal must observe certain timing requirements, which are shown in Figure 8 of the Timing Diagrams. The DCLK_RST pulse must be of a minimum width and its deassertion edge must observe setup and hold times with respect to the CLK input rising edge. These timing specifications are listed as tPWR, tSR and tHR and may be found in Table 14. The DCLK_RST signal can be asserted asynchronously to the input clock. If DCLK_RST is asserted, the DCLK output is held in a designated state (logic-high) in Demux Mode; in Non-Demux Mode, the DCLK continues to function normally. Depending upon when the DCLK_RST signal is asserted, 51 www.ti.com ADC12D1800 for this device is fCLK(MIN); see Table 14. However, it is possible to operate the device in 1:2 Demux Mode and capture data from just one 12-bit bus, e.g. just DI (or DId) although both DI and DId are fully operational. This will decimate the data by two and effectively halve the data rate. ADC12D1800 there may be a narrow pulse on the DCLK line during this reset event. When the DCLK_RST signal is de-asserted, there are tSYNC_DLY CLK cycles of systematic delay and the next CLK rising edge synchronizes the DCLK output with those of other ADC12D1800s in the system. For 90 Mode (DDRPh = logic-high), the synchronizing edge occurs on the rising edge of CLK, 4 cycles after the first rising edge of CLK after DCLK_RST is released. For 0 Mode (DDRPh = logiclow), this is 5 cycles instead. The DCLK output is enabled again after a constant delay of tOD. For both Demux and Non-Demux Modes, there is some uncertainty about how DCLK comes out of the reset state for the first DCLK_RST pulse. For the second (and subsequent) DCLK_RST pulses, the DCLK will come out of the reset state in a known way. Therefore, if using the DCLK Reset feature, it is recommended to apply one "dummy" DCLK_RST pulse before using the second DCLK_RST pulse to synchronize the outputs. This recommendation applies each time the device or channel is powered-on. When using DCLK_RST to synchronize multiple ADC12D1800s, it is required that the Select Phase bits in the Control Register (Addr: Eh, Bits 3,4) be the same for each Master ADC12D1800. Placing the power and ground planes on adjacent layers will provide low impedance decoupling of the ADC supplies, especially at higher frequencies. The output of a linear regulator should feed into the power plane through a low impedance multi-via connection. The power plane should be split into individual power peninsulas near the ADC. Each peninsula should feed a particular power bus on the ADC, with decoupling for that power bus connecting the peninsula to the ground plane near each power/ground pin pair. Using this technique can be difficult on many printed circuit CAD tools. To work around this, zero ohm resistors can be used to connect the power source net to the individual nets for the different ADC power buses. As a final step, the zero ohm resistors can be removed and the plane and peninsulas can be connected manually after all other error checking is completed. 18.5.2 Bypass Capacitors The general recommendation is to have one 100nF capacitor for each power/ground pin pair. The capacitors should be surface mount multi-layer ceramic chip capacitors similar to Panasonic part number ECJ-0EB1A104K. 18.5.3 Ground Planes Grounding should be done using continuous full ground planes to minimize the impedance for all ground return paths, and provide the shortest possible image/return path for all signal traces. 18.5 SUPPLY/GROUNDING, LAYOUT AND THERMAL RECOMMENDATIONS 18.5.1 Power Planes All supply buses for the ADC should be sourced from a common linear voltage regulator. This ensures that all power buses to the ADC are turned on and off simultaneously. This single source will be split into individual sections of the power plane, with individual decoupling and connection to the different power supply buses of the ADC. Due to the low voltage but relatively high supply current requirement, the optimal solution may be to use a switching regulator to provide an intermediate low voltage, which is then regulated down to the final ADC supply voltage by a linear regulator. Please refer to the documentation provided for the ADC12D1800RB for additional details on specific regulators that are recommended for this configuration. Power for the ADC should be provided through a broad plane which is located on one layer adjacent to the ground plane(s). www.ti.com 18.5.4 Power System Example The ADC12D1800RB uses continuous ground planes (except where clear areas are needed to provide appropriate impedance management for specific signals), see Figure 19. Power is provided on one plane, with the 1.9V ADC supply being split into multiple zones or peninsulas for the specific power buses of the ADC. Decoupling capacitors are connected between these power bus peninsulas and the adjacent ground planes using vias. The capacitors are located as close to the individual power/ground pin pairs of the ADC as possible. In most cases, this means the capacitors are located on the opposite side of the PCB to the ADC. 52 ADC12D1800 30123202 FIGURE 19. Power and Grounding Example 53 www.ti.com ADC12D1800 attached to the substrate top with exposed metal in the center top area of the package. This results in a 20% improvement (typical) in thermal performance over the standard plastic BGA package. 18.5.5 Thermal Management The Heat Slug Ball Grid Array (HSBGA) package is a modified version of the industry standard plastic BGA (Ball Grid Array) package. Inside the package, a copper heat spreader cap is 30123209 FIGURE 20. HSBGA Conceptual Drawing The center balls are connected to the bottom of the die by vias in the package substrate, Figure 20. This gives a low thermal resistance between the die and these balls. Connecting these balls to the PCB ground planes with a low thermal resistance path is the best way dissipate the heat from the ADC. These pins should also be connected to the ground plane via a low impedance path for electrical purposes. The direct connection to the ground planes is an easy method to spread heat away from the ADC. Along with the ground plane, the parallel power planes will provide additional thermal dissipation. The center ground balls should be soldered down to the recommended ball pads (See AN-1126). These balls will have wide traces which in turn have vias which connect to the internal ground planes, and a bottom ground pad/pour if possible. This ensures a good ground is provided for these balls, and that the optimal heat transfer will occur between these balls and the PCB ground planes. In spite of these package enhancements, analysis using the standard JEDEC JESD51-7 four-layer PCB thermal model shows that ambient temperatures must be limited to a max of 65C to ensure a safe operating junction temperature for the ADC12D1800. However, most applications using the ADC12D1800 will have a printed circuit board which is more complex than that used in JESD51-7. Typical circuit boards will have more layers than the JESD51-7 (eight or more), several of which will be used for ground and power planes. In those applications, the thermal resistance parameters of the ADC12D1800 and the circuit board can be used to determine the actual safe ambient operating temperature up to a maximum of 85C. Three key parameters are provided to allow for modeling and calculations. Because there are two main thermal paths between the ADC die and external environment, the thermal resistance for each of these paths is provided. JC1 represents the thermal resistance between the die and the exposed metal area on the top of the HSBGA package. JC2 represents the thermal resistance between the die and the center group of balls on the bottom of the HSBGA package. The final parameter is the allowed maximum junction temperature, which is TJ. In other applications, a heat sink or other thermally conductive path can be added to the top of the HSBGA package to remove heat. In those cases, JC1 can be used along with the thermal parameters for the heat sink or other thermal coupling www.ti.com added. Representative heat sinks which might be used with the ADC12D1800 include the Cool Innovations p/n 3-1212XXG and similar products from other vendors. In many applications, the printed circuit board will provide the primary thermal path conducting heat away from the ADC package. In those cases, JC2 can be used in conjunction with printed circuit board thermal modeling software to determine the allowed operating conditions that will maintain the die temperature below the maximum allowable limit. Additional dissipation can be achieved by coupling a heat sink to the copper pour area on the bottom side of the printed circuit board. Typically, dissipation will occur through one predominant thermal path. In these cases, the following calculations can be used to determine the maximum safe ambient operating temperature: TJ = TA + PD x (JC+CA) TJ = TA + PC(MAX) x (JC+CA) For JC, the value for the primary thermal path in the given application environment should be used (JC1 or JC2). CA is the thermal resistance from the case to ambient, which would typically be that of the heat sink used. Using this relationship and the desired ambient temperature, the required heat sink thermal resistance can be found. Alternately, the heat sink thermal resistance can be used to find the maximum ambient temperature. For more complex systems, thermal modeling software can be used to evaluate the printed circuit board system and determine the expected junction temperature given the total system dissipation and ambient temperature. 18.6 SYSTEM POWER-ON CONSIDERATIONS There are a couple important topics to consider associated with the system power-on event including configuration and calibration, and the Data Clock. 18.6.1 Power-on, Configuration, and Calibration Following the application of power to the ADC12D1800, several events must take place before the output from the ADC12D1800 is valid and at full performance; at least one full calibration must be executed with the device configured in the desired mode. Following the application of power to the ADC12D1800, there is a delay of tCalDly and then the Power-on Calibration is executed. This is why it is recommended to set the CalDly Pin via an external pull-up or pull-down resistor. This ensured that the 54 Another case is when the FPGA configures the Control Pins (Non-ECM) or writes to the SPI (ECM), see Figure 22. It is always necessary to comply with the Operating Ratings and Absolute Maximum ratings, i.e. the Control Pins may not be driven below the ground or above the supply, regardless of what the voltage currently applied to the supply is. Therefore, it is not recommended to write to the Control Pins or SPI before power is applied to the ADC12D1800. As long as the FPGA has completed writing to the Control Pins or SPI, the Power-on Calibration will result in a valid output at full performance. Once again, if it takes longer than tCalDly for the system to stabilize at its operating temperature, it is recommended to execute an on-command calibration at that time. Due to system requirements, it may not be possible for the FPGA to write to the Control Pins or SPI before the Power-on Calibration takes place, see Figure 23. It is not critical to configure the device before the Power-on Calibration, but it is critical to realize that the output for such a case is not at its full performance. Following an On-command Calibration, the device will be at its full performance. 30123264 FIGURE 21. Power-on with Control Pins set by Pull-up/down Resistors 30123265 FIGURE 22. Power-on with Control Pins set by FPGA pre Power-on Cal 55 www.ti.com ADC12D1800 state of that input will be properly set at the same time that power is applied to the ADC and tCalDly will be a known quantity. For the purpose of this section, it is assumed that CalDly is set as recommended. The Control Bits or Pins must be set or written to configure the ADC12D1800 in the desired mode. This must take place via either Extended Control Mode or Non-ECM (Pin Control Mode) before subsequent calibrations will yield an output at full performance in that mode. Some examples of modes include DES/Non-DES Mode, Demux/Non-demux Mode, and Full-Scale Range. The simplest case is when device is in Non-ECM and the Control Pins are set by pull-up/down resistors, see Figure 21. For this case, the settings to the Control Pins ramp concurrently to the ADC voltage. Following the delay of tCalDly and the calibration execution time, tCAL, the output of the ADC12D1800 is valid and at full performance. If it takes longer than tCalDly for the system to stabilize at its operating temperature, it is recommended to execute an on-command calibration at that time. ADC12D1800 30123266 FIGURE 23. Power-on with Control Pins set by FPGA post Power-on Cal 18.6.2 Power-on and Data Clock (DCLK) Many applications use the DCLK output for a system clock. For the ADC12D1800, each I- and Q-channel has its own DCLKI and DCLKQ, respectively. The DCLK output is always active, unless that channel is powered-down or the DCLK Reset feature is used while the device is in Demux Mode. As the supply to the ADC12D1800 ramps, the DCLK also comes up, see this example from the ADC12D1800RB: Figure 24. While the supply is too low, there is no output at DCLK. As the supply continues to ramp, DCLK functions intermittently with irregular frequency, but the amplitude continues to track with the supply. Much below the low end of operating supply range of the ADC12D1800, the DCLK is already fully operational. 18.7.1 Temperature Sensor The ADC12D1800 has an on-die temperature diode connected to pins Tdiode+/- which may be used to monitor the die temperature. National also provides a family of temperature sensors for this application which monitor different numbers of external devices, see Table 28. TABLE 28. Temperature Sensor Recommendation Recommended Temperature Sensor 1 LM95235 2 LM95213 4 LM95214 The temperature sensor (LM95235/13/14) is an 11-bit digital temperature sensor with a 2-wire System Management Bus (SMBus) interface that can monitor the temperature of one, two, or four remote diodes as well as its own temperature. It can be used to accurately monitor the temperature of up to one, two, or four external devices such as the ADC12D1800, a FPGA, other system components, and the ambient temperature. The temperature sensor reports temperature in two different formats for +127.875C/-128C range and 0/255C range. It has a Sigma-Delta ADC core which provides the first level of noise immunity. For improved performance in a noisy environment, the temperature sensor includes programmable digital filters for Remote Diode temperature readings. When the digital filters are invoked, the resolution for the Remote Diode readings increases to 0.03125C. For maximum flexibility and best accuracy, the temperature sensor includes offset registers that allow calibration for other types of diodes. Diode fault detection circuitry in the temperature sensor can detect the absence or fault state of a remote diode: whether D+ is shorted to the power supply, D- or ground, or floating. In the following typical application, the LM95213 is used to monitor the temperature of an ADC12D1800 as well as an FPGA, see Figure 25. If this feature is unused, the Tdiode+/pins may be left floating. 30123290 FIGURE 24. Supply and DCLK Ramping 18.7 RECOMMENDED SYSTEM CHIPS National recommends these other chips including temperature sensors, clocking devices, and amplifiers in order to support the ADC12D1800 in a system design. www.ti.com Number of External Devices Monitored 56 ADC12D1800 30123297 FIGURE 25. Typical Temperature Sensor Application 18.7.2 Clocking Device The clock source can be a PLL/VCO device such as the LMX2531LQxxxx family of products. The specific device should be selected according to the desired ADC sampling clock frequency. The ADC12D1800RB uses the LMX2531LQ1778E, with the ADC clock source provided by the Aux PLL output. Other devices which may be considered based on clock source, jitter cleaning, and distribution purposes are the LMK01XXX, LMK02XXX, LMK03XXX and LMK04XXX product families. 18.7.4 Balun Recommendations for Analog Input The following baluns are recommended for the ADC12D1800 for applications which require no gain. When evaluating a balun for the application of driving an ADC, some important qualities to consider are phase error and magnitude error. TABLE 30. Balun Recommendations Balun Bandwidth Mini-Circuits TC1-1-13MA+ 4.5 - 3000 MHz 18.7.3 Amplifiers for Analog Input The following amplifiers can be used for ADC12D1800 applications which require DC coupled input or signal gain, neither of which can be provided with a transformer coupled input circuit: Anaren B0430J50100A00 400 - 3000 MHz Mini-Circuits ADTL2-18 30 - 1800 MHz TABLE 29. Amplifier Recommendation Amplifier Bandwidth Brief features LMH6552 1.5 GHz Configurable gain LMH6553 900 MHz Output clamp and configurable gain LMH6554 2.8 GHz Configurable gain LMH6555 1.2 GHz Fixed gain 57 www.ti.com ADC12D1800 19.0 Register Definitions Eleven read/write registers provide several control and configuration options in the Extended Control Mode. These registers have no effect when the device is in the Non-extended Control Mode. Each register description below also shows the Power-On Reset (POR) state of each control bit. See Table 31 for a summary. For a description of the functionality and timing to read/write the control registers, see Section 17.2.2.1 The Serial Interface. Special Note: Register 6h must be written to 1C00h for the device to perform at full rated performance for Fclk > 1.6GHz. TABLE 31. Register Addresses www.ti.com A3 A2 A1 A0 Hex Register Addressed 0 0 0 0 0h Configuration Register 1 0 0 0 1 1h Reserved 0 0 1 0 2h I-channel Offset 0 0 1 1 3h I-channel Full-Scale Range 0 1 0 0 4h Calibration Adjust 0 1 0 1 5h Calibration Values 0 1 1 0 6h Bias Adjust 0 1 1 1 7h DES Timing Adjust 1 0 0 0 8h Reserved 1 0 0 1 9h Reserved 1 0 1 0 Ah Q-channel Offset 1 0 1 1 Bh Q-channel Full-Scale Range 1 1 0 0 Ch Aperture Delay Coarse Adjust 1 1 0 1 Dh Aperture Delay Fine Adjust 1 1 1 0 Eh AutoSync 1 1 1 1 Fh Reserved 58 Addr: 0h (0000b) Bit 15 Name CAL POR Bit 15 Bit 14 Bit 13 Bit 12 Bit 11 Bit 10 Bit 9 Bit 8 Bit 7 Bit 6 Bit 5 Bit 4 Bit 3 Bits 2:0 0 POR state: 2000h 14 13 12 11 10 9 8 7 6 5 4 3 DPS OVS TPM PDI PDQ Res LFS DES DEQ DIQ 2SC TSE 0 1 0 0 0 0 0 0 0 0 0 0 2 1 0 Res 0 0 0 CAL: Calibration Enable. When this bit is set to 1b, an on-command calibration is initiated. This bit is not reset automatically upon completion of the calibration. Therefore, the user must reset this bit to 0b and then set it to 1b again to execute another calibration. This bit is logically OR'd with the CAL Pin; both bit and pin must be set to 0b before either is used to execute a calibration. DPS: DCLK Phase Select. For DDR, set this bit to 0b to select the 0 Mode DDR Data-to-DCLK phase relationship and to 1b to select the 90 Mode. If the device is in Non-Demux Mode, this bit has no effect; the device will always be in 0DDR Mode. OVS: Output Voltage Select. This bit sets the differential voltage level for the LVDS outputs including Data, OR, and DCLK. 0b selects the lower level and 1b selects the higher level. See VOD in Table 12 for details. TPM: Test Pattern Mode. When this bit is set to 1b, the device will continually output a fixed digital pattern at the digital Data and OR outputs. When set to 0b, the device will continually output the converted signal, which was present at the analog inputs. See Section 17.3.2.6 Test Pattern Mode for details about the TPM pattern. PDI: Power-down I-channel. When this bit is set to 0b, the I-channel is fully operational; when it is set to 1b, the I-channel is powered-down. The I-channel may be powered-down via this bit or the PDI Pin, which is active, even in ECM. PDQ: Power-down Q-channel. When this bit is set to 0b, the Q-channel is fully operational; when it is set to 1b, the Q-channel is powered-down. The Q-channel may be powered-down via this bit or the PDQ Pin, which is active, even in ECM. Reserved. Must be set to 0b. LFS: Low-Frequency Select. If the sampling clock (CLK) is at or below 300 MHz, set this bit to 1b for improved performance. DES: Dual-Edge Sampling Mode select. When this bit is set to 0b, the device will operate in the Non-DES Mode; when it is set to 1b, the device will operate in the DES Mode. See Section 17.3.1.4 DES/Non-DES Mode for more information. DEQ: DES Q-input select, a.k.a. DESQ Mode. When the device is in DES Mode, this bit selects the input that the device will operate on. The default setting of 0b selects the I-input and 1b selects the Q-input. DIQ: DES I- and Q-input, a.k.a. DESIQ Mode. When in DES Mode, setting this bit to 1b shorts the I- and Q-inputs internally to the device. If the bit is left at its default 0b, the I- and Q-inputs remain electrically separate. To operate the device in DESIQ Mode, Bits<7:5> must be set to 101b. In this mode, both the I- and Q-inputs must be externally driven; see Section 17.3.1.4 DES/Non-DES Mode for more information. 2SC: Two's Complement output. For the default setting of 0b, the data is output in Offset Binary format; when set to 1b, the data is output in Two's Complement format. TSE: Time Stamp Enable. For the default setting of 0b, the Time Stamp feature is not enabled; when set to 1b, the feature is enabled. See Section 17.3.2 Output Control and Adjust for more information about this feature. Reserved. Must be set as shown. 59 www.ti.com ADC12D1800 Configuration Register 1 ADC12D1800 Reserved Addr: 1h (0001b) Bit POR state: 2A0Eh 15 14 13 12 11 10 9 8 7 6 5 4 3 2 1 0 0 0 1 0 1 0 1 0 0 0 0 0 1 1 1 0 10 9 8 7 6 5 4 3 2 1 0 0 0 0 0 0 Res Name POR Bits 15:0 Reserved. Must be set as shown. I-channel Offset Adjust Addr: 2h (0010b) Bit 15 13 Res Name POR POR state: 0000h 14 0 0 12 11 OS 0 0 OM(11:0) 0 0 0 0 0 0 0 Bits 15:13 Reserved. Must be set to 0b. Bit 12 OS: Offset Sign. The default setting of 0b incurs a positive offset of a magnitude set by Bits 11:0 to the ADC output. Setting this bet to 1b incurs a negative offset of the set magnitude. Bits 11:0 OM(11:0): Offset Magnitude. These bits determine the magnitude of the offset set at the ADC output (straight binary coding). The range is from 0 mV for OM(11:0) = 0d to 45 mV for OM(11:0) = 4095d in steps of ~11 V. Monotonicity is guaranteed by design only for the 9 MSBs. Code Offset [mV] 0000 0000 0000 (default) 0 1000 0000 0000 22.5 1111 1111 1111 45 I-channel Full Scale Range Adjust Addr: 3h (0011b) Bit 15 Name Res POR 0 POR state: 4000h 14 13 12 11 10 9 8 7 6 5 4 3 2 1 0 0 0 0 0 0 0 0 FM(14:0) 1 0 0 0 0 0 0 0 Bit 15 Reserved. Must be set to 0b. Bits 14:0 FM(14:0): FSR Magnitude. These bits increase the ADC full-scale range magnitude (straight binary coding.) The allowable range is from 800 mV (16384d) to 1000 mV (32767d) with the default setting at 800 mV (16384d). Monotonicity is guaranteed by design only for the 9 MSBs. A greater range of FSR values is available in ECM, i.e. FSR values above 800 mV. See VIN_FSR in Table 8 for characterization details. Code 100 0000 0000 0000 (default) 111 1111 1111 1111 www.ti.com FSR [mV] 800 1000 60 Addr: 4h (0100b) POR state: DF4Bh Bit 15 14 Name Res CSS POR 1 1 Bit 15 Bit 14 Bits 13:8 Bit 7 Bits 6:0 13 12 11 0 1 1 10 9 8 1 1 1 Res 7 6 5 4 1 0 0 SSC 0 3 2 1 0 0 1 1 Res 1 Reserved. Must be set as shown. CSS: Calibration Sequence Select. The default 1b selects the following calibration sequence: reset all previously calibrated elements to nominal values, do RIN Calibration, do internal linearity Calibration. Setting CSS = 0b selects the following calibration sequence: do not reset RIN to its nominal value, skip RIN calibration, do internal linearity Calibration. The calibration must be completed at least one time with CSS = 1b to calibrate RIN. Subsequent calibrations may be run with CSS = 0b (skip RIN calibration) or 1b (full RIN and internal linearity Calibration). Reserved. Must be set as shown. SSC: SPI Scan Control. Setting this control bit to 1b allows the calibration values, stored in Addr: 5h, to be read/ written. When not reading/writing the calibration values, this control bit should left at its default 0b setting. See Section 17.3.3 Calibration Feature for more information. Reserved. Must be set as shown. Calibration Values Addr: 5h (0101b) Bit POR state: XXXXh 15 14 13 12 11 10 9 X X X X X X X Bits 15:0 7 6 5 4 3 2 1 0 X X X X X X X SS(15:0) Name POR 8 X X SS(15:0): SPI Scan. When the ADC performs a self-calibration, the values for the calibration are stored in this register and may be read from/ written to it. Set SSC (Addr: 4h, Bit 7) to read/write. See Section 17.3.3 Calibration Feature for more information. Bias Adjust Addr: 6h (0110b) Bit POR state: 1C20h 15 14 13 12 11 10 9 0 0 0 1 1 1 0 Bits 15:0 7 6 5 4 3 2 1 0 0 1 0 0 0 0 0 MPA(15:0) Name POR 8 0 0 MPA(15:0): Max Power Adjust. This register must be written to 1C00h to achieve full rated performance for Fclk > 1.6GHz. DES Timing Adjust Addr: 7h (0111b) Bit 15 POR state: 8140h 14 13 Bits 15:9 Bits 8:0 11 10 9 8 7 6 5 DTA(6:0) Name POR 12 1 0 0 0 4 3 2 1 0 0 0 0 0 Res 0 0 0 1 0 1 0 0 DTA(6:0): DES Mode Timing Adjust. In the DES Mode, the time at which the falling edge sampling clock samples relative to the rising edge of the sampling clock may be adjusted; the automatic duty cycle correction continues to function. See Section 17.3.1 Input Control and Adjust for more information. The nominal step size is 30fs. Reserved. Must be set as shown. 61 www.ti.com ADC12D1800 Calibration Adjust ADC12D1800 Reserved Addr: 8h (1000b) Bit POR state: 0000h 15 14 13 12 11 10 9 8 7 6 5 4 3 2 1 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 10 9 8 7 6 5 4 3 2 1 0 0 0 0 Res Name POR Bits 15:0 Reserved. Must be set as shown. Reserved Addr: 9h (1001b) 15 Bit POR state: 0000h 14 13 12 11 Res Name 0 POR Bits 15:0 0 0 0 0 0 0 0 0 0 0 0 0 11 10 9 8 7 6 5 4 3 2 1 0 0 0 0 0 0 0 0 0 0 0 Reserved. Must be set as shown. Q-channel Offset Adjust Addr: Ah (1010b) Bit 15 POR state: 0000h 13 Res Name POR 14 0 0 12 OS 0 0 OM(11:0) 0 0 Bits 15:13 Reserved. Must be set to 0b. Bit 12 OS: Offset Sign. The default setting of 0b incurs a positive offset of a magnitude set by Bits 11:0 to the ADC output. Setting this bet to 1b incurs a negative offset of the set magnitude. Bits 11:0 OM(11:0): Offset Magnitude. These bits determine the magnitude of the offset set at the ADC output (straight binary coding). The range is from 0 mV for OM(11:0) = 0d to 45 mV for OM(11:0) = 4095d in steps of ~11 V. Monotonicity is guaranteed by design only for the 9 MSBs. Code Offset [mV] 0000 0000 0000 (default) 0 1000 0000 0000 22.5 1111 1111 1111 45 Q-channel Full-Scale Range Adjust Addr: Bh (1011b) Bit 15 Name Res POR 0 POR state: 4000h 14 13 12 11 10 9 8 1 0 0 0 0 0 0 7 6 5 4 3 2 1 0 0 0 0 0 0 0 0 FM(14:0) 0 Bit 15 Reserved. Must be set to 0b. Bits 14:0 FM(14:0): FSR Magnitude. These bits increase the ADC full-scale range magnitude (straight binary coding.) The allowable range is from 800 mV (16384d) to 1000 mV (32767d) with the default setting at 800 mV (16384d). Monotonicity is guaranteed by design only for the 9 MSBs. A greater range of FSR values is available in ECM, i.e. FSR values above 800 mV. See VIN_FSR in Table 8 for characterization details. Code 100 0000 0000 0000 (default) 111 1111 1111 1111 www.ti.com FSR [mV] 800 1000 62 Addr: Ch (1100b) Bit POR state: 0004h 15 14 13 12 11 0 0 0 0 0 9 8 7 6 5 4 0 0 0 0 0 CAM(11:0) Name POR 10 0 0 3 2 STA DCC 0 1 1 0 Res 0 0 Using the tAD Adjust feature at its maximum setting, for the maximum sampling clock rate, may affect the integrity of the sampling clock on chip. Therefore, it is not recommended to do so. The maximum setting for the coarse adjust is 825ps. The period for the maximum sampling clock rate of is 555ps, so it should not be necessary to exceed this value in any case. Bits 15:4 Bit 3 Bit 2 Bits 1:0 CAM(11:0): Coarse Adjust Magnitude. This 12-bit value determines the amount of delay that will be applied to the input CLK signal. The range is 0 ps delay for CAM(11:0) = 0d to a maximum delay of 825 ps for CAM(11:0) = 2431d (95 ps due to PVT variation) in steps of ~340 fs. For code CAM(11:0) = 2432d and above, the delay saturates and the maximum delay applies. Additional, finer delay steps are available in register Dh. The STA (Bit 3) must be selected to enable this function. STA: Select tAD Adjust. Set this bit to 1b to enable the tAD adjust feature, which will make both coarse and fine adjustment settings, i.e. CAM(11:0) and FAM(5:0), available. DCC: Duty Cycle Correct. This bit can be set to 0b to disable the automatic duty-cycle stabilizer feature of the chip. This feature is enabled by default. Reserved. Must be set to 0b. Aperture Delay Fine Adjust Addr: Dh (1101b) Bit 15 14 13 12 11 10 9 FAM(5:0) Name POR POR state: 0000h 0 0 0 0 8 7 6 5 4 Res 0 0 0 3 2 1 0 0 0 0 0 Res 0 0 0 0 0 Using the tAD Adjust feature at its maximum setting, for the maximum sampling clock rate, may affect the integrity of the sampling clock on chip. Therefore, it is not recommended to do so. The maximum setting for the coarse adjust is 825ps. The period for the maximum sampling clock rate of is 555ps, so it should not be necessary to exceed this value in any case. Bits 15:10 FAM(5:0): Fine Aperture Adjust Magnitude. This 6-bit value determines the amount of additional delay that will be applied to the input CLK when the Clock Phase Adjust feature is enabled via STA (Addr: Ch, Bit 3). The range is straight binary from 0 ps delay for FAM(5:0) = 0d to 2.3 ps delay for FAM(5:0) = 63d (300 fs due to PVT variation) in steps of ~36 fs. Bits 9:0 Reserved. Must be set as shown. AutoSync Addr: Eh (1110b) Bit POR state: 0003h 15 14 13 12 0 0 0 0 10 9 8 7 6 0 0 0 0 0 DRC(8:0) Name POR 11 0 5 4 0 0 Res 63 3 SP(1:0) 0 2 1 0 ES DOC DR 0 1 1 www.ti.com ADC12D1800 Aperture Delay Coarse Adjust ADC12D1800 Bits 15:7 Bits 6:5 Bits 4:3 Bit 2 Bit 1 Bit 0 DRC(8:0): Delay Reference Clock (9:0). These bits may be used to increase the delay on the input reference clock when synchronizing multiple ADCs. The minimum delay is 0s (0d) to 1000 ps (319d). The delay remains the maximum of 1000 ps for any codes above or equal to 639d. See Section 18.4 SYNCHRONIZING MULTIPLE ADC12D1800S IN A SYSTEM for more information. Reserved. Must be set as shown. SP(1:0): Select Phase. These bits select the phase of the reference clock which is latched. The codes correspond to the following phase shift: 00 = 0 01 = 90 10 = 180 11 = 270 ES: Enable Slave. Set this bit to 1b to enable the Slave Mode of operation. In this mode, the internal divided clocks are synchronized with the reference clock coming from the master ADC. The master clock is applied on the input pins RCLK. If this bit is set to 0b, then the device is in Master Mode. DOC: Disable Output reference Clocks. Setting this bit to 0b sends a CLK/4 signal on RCOut1 and RCOut2. The default setting of 1b disables these output drivers. This bit functions as described, regardless of whether the device is operating in Master or Slave Mode, as determined by ES (Bit 2). DR: Disable Reset. The default setting of 1b leaves the DCLK_RST functionality disabled. Set this bit to 0b to enable DCLK_RST functionality. Reserved Addr: Fh (1111b) Bit 15 14 POR state: 0018h 13 12 11 10 9 8 Bits 15:0 www.ti.com 6 5 4 3 2 1 0 0 0 0 1 1 0 0 0 Res Name POR 7 0 0 0 0 0 0 0 0 Reserved. This address is read only. 64 ADC12D1800 20.0 Physical Dimensions inches (millimeters) unless otherwise noted NOTES: UNLESS OTHERWISE SPECIFIED REFERENCE JEDEC REGISTRATION MS-034, VARIATION BAL-2. 292-Ball BGA Thermally Enhanced Package Order Number ADC12D1800CIUT NS Package Number UFH292A 65 www.ti.com ADC12D1800 12-Bit 3.6 GSPS Ultra High-Speed ADC Notes TI/NATIONAL INTERIM IMPORTANT NOTICE Texas Instruments has purchased National Semiconductor. As of Monday, September 26th, and until further notice, products sold or advertised under the National Semiconductor name or logo, and information, support and interactions concerning such products, remain subject to the preexisting National Semiconductor standard terms and conditions of sale, terms of use of website, and Notices (and/or terms previously agreed in writing with National Semiconductor, where applicable) and are not subject to any differing terms and notices applicable to other TI components, sales or websites. To the extent information on official TI and National websites and business social networking media, etc., pertains to both TI and National-branded products, both companies' instructions, warnings and limitations in the above-referenced terms of use apply. Following are URLs where you can obtain information on other Texas Instruments products and application solutions: Products Applications Audio www.ti.com/audio Communications and Telecom www.ti.com/communications Amplifiers amplifier.ti.com Computers and Peripherals www.ti.com/computers Data Converters dataconverter.ti.com Consumer Electronics www.ti.com/consumer-apps DLP(R) Products www.dlp.com Energy and Lighting www.ti.com/energy DSP dsp.ti.com Industrial www.ti.com/industrial Clocks and Timers www.ti.com/clocks Medical www.ti.com/medical Interface interface.ti.com Security www.ti.com/security Logic logic.ti.com Space, Avionics and Defense www.ti.com/space-avionicsdefense Power Mgmt power.ti.com Transportation and Automotive www.ti.com/automotive Microcontrollers microcontroller.ti.com Video and Imaging www.ti.com/video RFID www.ti-rfid.com www.ti.com/wireless-apps RF/IF and ZigBee(R) Solutions www.ti.com/lprf Wireless TI E2E Community Home Page e2e.ti.com Mailing Address: Texas Instruments, Post Office Box 655303, Dallas, Texas 75265 Copyright(c) 2011 Texas Instruments Incorporated www.ti.com IMPORTANT NOTICE Texas Instruments Incorporated and its subsidiaries (TI) reserve the right to make corrections, modifications, enhancements, improvements, and other changes to its products and services at any time and to discontinue any product or service without notice. Customers should obtain the latest relevant information before placing orders and should verify that such information is current and complete. All products are sold subject to TI's terms and conditions of sale supplied at the time of order acknowledgment. TI warrants performance of its hardware products to the specifications applicable at the time of sale in accordance with TI's standard warranty. Testing and other quality control techniques are used to the extent TI deems necessary to support this warranty. Except where mandated by government requirements, testing of all parameters of each product is not necessarily performed. TI assumes no liability for applications assistance or customer product design. Customers are responsible for their products and applications using TI components. To minimize the risks associated with customer products and applications, customers should provide adequate design and operating safeguards. TI does not warrant or represent that any license, either express or implied, is granted under any TI patent right, copyright, mask work right, or other TI intellectual property right relating to any combination, machine, or process in which TI products or services are used. Information published by TI regarding third-party products or services does not constitute a license from TI to use such products or services or a warranty or endorsement thereof. Use of such information may require a license from a third party under the patents or other intellectual property of the third party, or a license from TI under the patents or other intellectual property of TI. Reproduction of TI information in TI data books or data sheets is permissible only if reproduction is without alteration and is accompanied by all associated warranties, conditions, limitations, and notices. Reproduction of this information with alteration is an unfair and deceptive business practice. TI is not responsible or liable for such altered documentation. Information of third parties may be subject to additional restrictions. Resale of TI products or services with statements different from or beyond the parameters stated by TI for that product or service voids all express and any implied warranties for the associated TI product or service and is an unfair and deceptive business practice. TI is not responsible or liable for any such statements. TI products are not authorized for use in safety-critical applications (such as life support) where a failure of the TI product would reasonably be expected to cause severe personal injury or death, unless officers of the parties have executed an agreement specifically governing such use. Buyers represent that they have all necessary expertise in the safety and regulatory ramifications of their applications, and acknowledge and agree that they are solely responsible for all legal, regulatory and safety-related requirements concerning their products and any use of TI products in such safety-critical applications, notwithstanding any applications-related information or support that may be provided by TI. Further, Buyers must fully indemnify TI and its representatives against any damages arising out of the use of TI products in such safety-critical applications. TI products are neither designed nor intended for use in military/aerospace applications or environments unless the TI products are specifically designated by TI as military-grade or "enhanced plastic." Only products designated by TI as military-grade meet military specifications. Buyers acknowledge and agree that any such use of TI products which TI has not designated as military-grade is solely at the Buyer's risk, and that they are solely responsible for compliance with all legal and regulatory requirements in connection with such use. TI products are neither designed nor intended for use in automotive applications or environments unless the specific TI products are designated by TI as compliant with ISO/TS 16949 requirements. Buyers acknowledge and agree that, if they use any non-designated products in automotive applications, TI will not be responsible for any failure to meet such requirements. Following are URLs where you can obtain information on other Texas Instruments products and application solutions: Products Applications Audio www.ti.com/audio Communications and Telecom www.ti.com/communications Amplifiers amplifier.ti.com Computers and Peripherals www.ti.com/computers Data Converters dataconverter.ti.com Consumer Electronics www.ti.com/consumer-apps DLP(R) Products www.dlp.com Energy and Lighting www.ti.com/energy DSP dsp.ti.com Industrial www.ti.com/industrial Clocks and Timers www.ti.com/clocks Medical www.ti.com/medical Interface interface.ti.com Security www.ti.com/security Logic logic.ti.com Space, Avionics and Defense www.ti.com/space-avionics-defense Power Mgmt power.ti.com Transportation and Automotive www.ti.com/automotive Microcontrollers microcontroller.ti.com Video and Imaging RFID www.ti-rfid.com OMAP Mobile Processors www.ti.com/omap Wireless Connectivity www.ti.com/wirelessconnectivity TI E2E Community Home Page www.ti.com/video e2e.ti.com Mailing Address: Texas Instruments, Post Office Box 655303, Dallas, Texas 75265 Copyright (c) 2011, Texas Instruments Incorporated