Class 2 Transformers Transformateurs de categorie 2 Transformadores de Clase 2 GENERAL PRECAUTIONARY INFORMATION THIS TRANSFORMER MUST BE INSTALLED BY A QUALIFIED INSTALLER. All wiring must conform to local and national electrical codes and ordinances. ! WARNING Do not use on circuits exceeding specified voltages. Higher voltages will damage control and could cause shock or fire hazard If power disconnect switch is not in sight, lock it in the OFF position and tag it to prevent unexpected application of power. ! CAUTION To prevent electrical shock and/or equipment damage, disconnect electric power to system at main fuse or circuit breaker box until installation is complete. Label all wires prior to disconnection when servicing controls. Wiring errors can cause improper and dangerous operation. Following installation or replacement, follow appliance manufacturers' recommended installation/service instructions to insure proper operation. PRECAUTIONS GENERALES CE TRANSFORMATEUR DOIT ETRE INSTALLE PAR UN TECHNICIEN QUALIFIE. Tous les branchements doivent etre conformes aux codes electriques et reglements locaux et nationaux. AVERTISSEMENT ! Ne pas utiliser sur des circuits avec une tension superieure a celle specifiee. Une tension plus elevee peut endommager la commande et creer un risque d'incendie. REMARQUES Si le sectionneur n'est pas visible, verrouillez-le en position ARReT et etiquetez-le pour empecher toute mise sous tension accidentelle. ! ATTENTION Pour eviter les risques d'electrocution et/ou de degats de l'equipement, il faut debrancher l'alimen tation electrique du systeme au fusible ou au coupe-circuit principal jusqu'a la fin de l'intervention. Lors d'une intervention, il faut identifier tous les fils avant de les debrancher. Un mauvais branchement peut causer un mauvais fonctionnement qui peut etre dangereux. Apres l'installation ou le remplacement, suivre les instructions d'installation recommandees par le fabricant de l'appareil pour assurer le bon fonctionnement. INFORMACION DE LAS PRECAUCIONES GENERALES UN INSTALADOR CALIFICADO TIENE QUE INSTALAR ESTE TRANSFORMADOR. Todo el cableado tiene que cumplir con las regulaciones y codigos electricos nacionales y locales. ! ADVERTENCIA ! PRECAUCION Para evitar el choque electrico y/o el dano en el equi po, desconecte la energia electrica que va al sistema en el fusible principal o en la caja de interruptores de circuito hasta que se haya completado la instalacion. No lo use en circuitos que excedan los voltajes especificados. Los voltajes mas altos danaran el control y pueden producir peligros de choque o incendio. Marque todos los cables antes de la desconexion cuando le haga el servicio a los controles. Los errores en el cableado pueden producir una operacion incorrecta y peligrosa. AVISOS Despues de la instalacion o del cambio, siga las instrucciones de instalacion/servicio recomendadas por el fabricante del artefacto para asegurarse que la operacion sera la correcta. Si el interruptor de desconexion de la energia no esta a la vista, asegurelo en la posicion de APAGADO y marquelo para impedir la aplicacion de energia inesperada. PART NO. 37-6609D www.white-rodgers.com www.emersonclimate.com Replaces 37-6609C 1321 Insulation Rating: Class B (130C) Agency: UL 5085 - File E33334; UL recognized component for use in the US and Canada Isolation: Classe B (130C) Agence: UL 5085 - E33334; Composant homologue UL pour utilisation aux USA et au Canada Radio de Aislante: Clase B (130C) Agencia: UL 5085 - E33334; Componente reconocido por UL para uso en USA y Canada Part No. N de piece Nu de Parte. WR Output Sortie Salida Input Entree Entrada VAC VAC VAC Part No. N de piece Nu de Parte. Volts Volts Volts Hz Hz Hz 120 208 240 50/60 90-T60C3 120 208 240 50/60 24 2.50 60 90-T75C3 120 208 240 50/60 24 3.13 75 90-T50C3 Amps Amperes Amps VA VA VA WR Volts Volts Volts Hz Hz Hz 2.08 50 90-T40F1 120 50/60 90-T40F2 208 240 50/60 90-T40F3 120 208 240 90-T50F3 120 208 240 24 CIRCUIT BREAKER DISJONCTEUR CIRCUITO CORTADO 240V Input Entree Entrada Output Sortie Salida VAC VAC VAC Amps Amperes Amps VA VA VA 24 1.67 40 24 1.67 40 60 24 1.67 40 60 24 2.08 50 240V 208V 208V 120V 24VAC COM COM Part No. N de piece Nu de Parte. Input Entree Entrada 120V 24VAC COM COM Output Sortie Salida VAC VAC VAC WR Volts Volts Volts Hz Hz Hz 90-T40M1* 120 50/60 90-T40M2* 208 240 50/60 90-T40M3* 120 208 240 90-T50M3* 120 208 240 Part No. N de piece Nu de Parte. Amps Amperes Amps VA VA VA 24 1.67 40 24 1.67 40 60 24 1.67 40 60 24 2.08 50 480V 240V * Includes 4" X 4" mounting plate. * Comprenant plaque de montage de 4 x 4 po. * Incluye base de montaje 4" X 4 ". Input Entree Entrada Output Sortie Salida WR Volts Volts Volts Hz Hz Hz VAC VAC VAC VA VA VA 90-T100C4 120 208 240 480 50/60 24 100 CIRCUIT BREAKER DISJONCTEUR CIRCUITO CORTADO 208V 120V 24VAC COM COM 240V 208V 120V 24VAC COM COM GND GND Input Entree Entrada Output Sortie Salida COM 120V 208V 240V 480 GND COM Black White Red Orange Black/Red Green Blue Nior Blanc Rouge Negro Blanco Rojo Orange Nior/Rouge Vert Naranja Negro/Rojo Verde Unused Input leads must be insulated. Isoler les fils d'entree inutilises. Entradas que no se usen deben ser aisladas. 24VAC Yellow Bleu Janue Azul Amarillo NOTES: 1. Leads #18 AWG, 11", stripped .75". REMARQUES : 1. Fils n 18 AWG de 11 po denudes de 0,75 po. NOTAS: 1. Almabres Calibre # 18 , 11", con desofrre de .75". White-Rodgers is a business of Emerson Electric Co. The Emerson logo is a trademark and service mark of Emerson Electric Co. www.white-rodgers.com www.emersonclimate.com Mouser Electronics Authorized Distributor Click to View Pricing, Inventory, Delivery & Lifecycle Information: White-Rodgers: 90-T50M3