MITSUBISHI <INTELLIGENT POWER MODULES>
PM300RSD060
FLAT-BASE TYPE
INSULATED PACKAGE
Sep. 2001
RECOMMENDED CONDITIONS FOR USE
Recommended value Unit
Test Condition
Symbol Parameter
V
Applied across P-N terminals
Applied between : VUP1-VUPC, VVP1-VVPC
VWP1-VWPC, VN1-VNC (Note-4)
Applied between : UP-VUPC, VP-VVPC, WP-VWPC
UN • VN • WN • Br-VNC
Using Application Circuit input signal of IPM, 3φ
sinusoidal PWM VVVF inverter (Fig. 8)
For IPM’s each input signals (Fig. 7)
Supply Voltage
Control Supply Voltage
Input ON Voltage
Input OFF Voltage
PWM Input Frequency
Arm Shoot-through
Blocking Time
≤ 400
15 ±1.5
≤ 0.8
≥ 4.0
≤ 20
≥ 2.5
VCC
VCIN(ON)
VCIN(OFF)
fPWM
tdead
VDV
kHz
µs
V
(Note-4) Allowable Ripple rating of Control Voltage : dv/dt ≤ ±5V/µs, 2Vp-p
3.5
3.5
—
—
—
—
Main terminal screw : M5
Mounting part screw : M5
—
Symbol Parameter
Mounting torque
Mounting torque
Weight
Test Condition Unit
N • m
N • m
g
Limits
Min. Typ. Max.
2.5
2.5
—
3.0
3.0
920
MECHANICAL RATINGS AND CHARACTERISTICS
—
—
—
—
—
VCE(sat)
ICES
VFM
V
mA
Min. Typ. Max.
V
Collector-Emitter
Saturation Voltage
FWDi Forward Voltage
Collector-Emitter
Cutoff Current
IF = 100A (Fig. 2)
Tj = 25°C
Tj = 125°C
Unit
ParameterSymbol Test Condition Limits
2.80
3.05
3.3
1
10
2.35
2.55
2.2
—
—
Tj = 25°C
Tj = 125°C
BRAKE PART
VD = 15V, IC = 100A
VCIN = 0V, Pulsed (Fig. 1)
V
CE
= V
CES
, V
CIN
= 15V
(Fig. 4)
VD = 15V, VCIN = 15V
Applied between : UP-VUPC, VP-VVPC, WP-VWPC
UN • VN • WN • Br-VNC
ID
°C
V
mA
ms
72
18
1.8
2.3
1270
1060
—
—
—
—
—
125
—
12.5
—
0.01
15
—
mA
Circuit Current
Input ON Threshold Voltage
Input OFF Threshold Voltage
Over Current Trip Level
Short Circuit Trip Level
Over Current Delay Time
Over Temperature Protection
Supply Circuit Under-Voltage
Protection
Fault Output Current
Minimum Fault Output Pulse
Width
Vth(ON)
Vth(OFF)
OC
SC
toff(OC)
OT
OTr
UV
UVr
IFO(H)
IFO(L)
tFO
Trip level
Reset level
Trip level
Reset level
—
—
1.2
1.7
—
651
390
140
—
—
—
111
—
11.5
—
—
—
1.0
Parameter
Symbol Test Condition Max.
Min. Typ. Unit
Limits
52
13
1.5
2.0
—
766
—
195
760
292
10
118
100
12.0
12.5
—
10
1.8
Base-plate
Temperature detection, VD = 15V
–20 ≤ Tj ≤ 125°C
VD = 15V, VFO = 15V (Note-3)
VD = 15V (Note-3)
V
µs
Inverter part
VD = 15V (Fig. 5,6)
Break part
–20 ≤ Tj ≤ 125°C, VD = 15V (Fig. 5,6)
–20≤ Tj ≤ 125°C, VD = 15V (Fig. 5,6)
VD = 15V (Fig. 5,6)
VN1-VNC
VXP1-VXPC
Tj = –20°C
Tj = 25°C
Tj = 125°C
Inverter part
Brake part
A
A
CONTROL PART
(Note-3) Fault output is given only when the internal OC, SC, OT & UV protection.
Fault output of OC, SC and UV protection operate by upper and lower arms.
Fault output of OT protection operate by lower arm.
Fault output of OC, SC protection given pulse.
Fault output of OT, UV protection given pulse while over level.