MIT300 Series
Insulation and Continuity Testers
In addition the range meets the requirements of IEC
61010-1 for safe connection to a 440 V Installation
Category III supply (600 V Phase to Earth).
The MIT330 additionally offers the facility to save test
results to internal memory. Over 1000 result can be saved
onsite, and downloaded to a computer when convenient.
Data is stored in non-volatile memory, being retained
when the instrument is switched off or batteries are
exhausted.
AJob reference number can be selected for a range of
results, allowing separate locations to be tested with the
same tester and easily separated when downloaded.
Amemory bar graph acts as a ‘Fuel Gauge’ showing how
much memory has been used.
Test results are downloaded to CSV (Coma Separated
Variable) spreadsheets, and can be imported into
Microsoft Excel. If certificates or reports are required, the
results can be downloaded directly into Megger
Powersuite Professional with a range of features for
creating professionally finished documentation.
APPLICATIONS
The MIT300 series has applications in all aspects of
domestic, commercial and industrial electrical contracting,
building maintenance, testing, inspection and servicing.
Combining both Insulation testing and continuity testing,
each instrument caters for all aspects of fixed wiring
installations.
Further applications can be found in panel building,
testing of motors, generators, switchgear and power tools,
street lighting and low volume manufacturing
environments etc.
The MIT300 range is supplied with a full 3 year warranty.
SPECIFICATIONS
Insulation ranges
Nominal Test Voltage
MIT310, 310A, 320, 330 1000 V, 500 V, 250 V (d.c.)
MIT300 500 V, 250 V (d.c.)
Measuring Range
All instruments 10 kΩ-999 MΩon all ranges
Short Circuit Current 1.5 mA nominal
Test Current on Load 1mA at min. pass values of
insulation (as specified in BS7671,
HD 384 and IEC 364)
Accuracy (at 20° C)
MIT300, 310, 320, 330 ±3%, ±2 digits up to 10 MΩ,
±5% up to 100 MΩ,±30% up to
full scale
MIT310A <2.5% of scale length (or 30% of
reading 200 kΩto 10 MΩ)
Continuity ranges
Measuring Range: 0.01 Ω-99.9 Ω(0 -50 Ωon
analog scale)
Open Circuit Voltage: 5 V ±1 V
Short Circuit Current:
MIT300, 310, 320, 330 205 mA +10 mA –5 mA
MIT310A 200 - 250 mA
Terminal Characteristics
Accuracy (at 20° C)
MIT300, 310, 320,330 ±3% ±2 digits
MIT310A ±2.5% of scale length (or 30% of
reading 0.2 Ωto 2 kΩ)
Zero Offset Adjust:
MIT300, 310,320, 330 0-9Ω
MIT310A 0 - 0.5 Ω
Continuity Buzzer
MIT300, 310 Operates at < 5 Ω
MIT320, 330 Adjustable 1 Ωto 20 Ω
MIT310A Operates at < 5 Ω
MIT300, 310, 320, 330 Response time <20 ms
MIT310A Response time <100 mS
Resistance range MIT320/330
(can be used for diode testing)
Measuring Range: 10 Ω-1MΩ
Open Circuit Voltage: 5 V
Short Circuit Current: 1.5 mA
Accuracy (at 20° C): ±5% ±2 digits up to 100 kΩ
Measuring Range (MIT310A) 0 - 2kΩ(refer to continuity)
Voltage range
Measuring Range: 0-600 V a.c. (50/60 Hz) or d.c.
Accuracy (at 20° C)
MIT300, 310, 320, 330 d.c. or a.c. (50/60 Hz):
±1%, ±2digits
MIT310A ±2.5% of scale length for 50/60Hz
Temperature coefficient: <0.1% per °C on all ranges.
Default voltmeter
All modes except off
MIT310, 320, 330 >25 V a.c. or d.c. is applied display
will operate as a voltmeter.
MIT300 Beeps and flash ‘V’ on the display
MIT310A All modes including OFF
Test inhibit:
If more than 50 volts is detected, testing will be inhibited.
AutoPower Down (MIT310, 320, 330)
Auto power down operates after 10 minutes if left in standby
mode.
Temperature and humidity
Operating Range: 14°F to 140°F (-10°C to +60°C)
Operating Humidity: 93% R.H. at +40°Cmax.
Storage Range: -13°F to +158°F (-25°C to +70°C)
Test Result Storage (1000 results)
Job Number 255 locations
Distribution Board no. 99 locations
Circuits 99 locations
Phases P1, P2, P3
Last recorded result may be recalled to the display.
All data can be downloaded to a PC using Download Manager
(supplied) or Megger Powersuite Professional of Windows
software