MIT300 Series Insulation and Continuity Testers MIT300 Series Insulation and Continuity Testers DESCRIPTION The Megger MIT300, MIT310 and MIT320 all feature the popular Megger digital/analog display. Large 20mm high characters provide very clear readout, combined with an analog arc for the feel of an analog instrument, with a true analog response. Extremely easy to use Tough rubber armoured case Self contained protective cover Live circuit warning Weatherproof to IP54 Intelligent Safety System for protection Result storage and downloading Download software included USB interface Continuity and buzzer testing starts automatically on connection to the circuit. Insulation tests being activated from the instrument or the switch probe, supplied with MIT320 and MIT330 (not suitable for the use with the MIT300 or MIT310). Backlighting: The Megger MIT310A has a moving coil display for those who prefer a real moving needle. Black decals on a white background give high contrast, even in poor light conditions. Tough: Designed to take the bashing that testers receive on site, the Megger MIT insulation testers are rubber armoured. The rigid display cover folds right out of the way during testing and locks down to protect the display when it is finished. Both the display and the range selected can be read in the dark because the MIT 320/330 has a backlit display and range selection. Safety features: To protect the user and the tester from incorrect use the MIT series all have an extensive range of features known as the Megger Intelligent Safety System including: Safety Interlock - prevents unsafe connection of test leads No buried functions mean it is obvious how to use the Megger MIT. Safe contact detectors - Even if the MIT is connected to a live circuit whilst on continuity setting the tester will remain safe and not be damaged. Colour coded ranges help test selection, reducing testing time and help with fault location. Live voltage warning - alerts the operator when a circuit voltage over 25 V exists. A user guide in the lid provides all the basic information. Safety lockout - Prevents the test from operating when the circuit voltage is >50 V. Continuity check - prevents a continuity test or buzzer test on a live circuit. Simple to use: Hands free use: It hangs comfortably around the neck for hands-free use because the instrument is carefully balanced. All the MIT instruments meet or exceed the UK and International Wiring Regulations, including requirements of BS7671 and VDE 0413 parts 1 and 4, HD 384, IEC 364, NFC15-100, NEN3140, ES59009 and EN 61557. MIT300 Series Insulation and Continuity Testers In addition the range meets the requirements of IEC 61010-1 for safe connection to a 440 V Installation Category III supply (600 V Phase to Earth). Terminal Characteristics The MIT330 additionally offers the facility to save test results to internal memory. Over 1000 result can be saved on site, and downloaded to a computer when convenient. Data is stored in non-volatile memory, being retained when the instrument is switched off or batteries are exhausted. A Job reference number can be selected for a range of results, allowing separate locations to be tested with the same tester and easily separated when downloaded. A memory bar graph acts as a `Fuel Gauge' showing how much memory has been used. Test results are downloaded to CSV (Coma Separated Variable) spreadsheets, and can be imported into Microsoft Excel. If certificates or reports are required, the results can be downloaded directly into Megger Powersuite Professional with a range of features for creating professionally finished documentation. APPLICATIONS The MIT300 series has applications in all aspects of domestic, commercial and industrial electrical contracting, building maintenance, testing, inspection and servicing. Combining both Insulation testing and continuity testing, each instrument caters for all aspects of fixed wiring installations. Accuracy (at 20 C) MIT300, 310, 320,330 MIT310A Zero Offset Adjust: MIT300, 310,320, 330 MIT310A 0-9 0 - 0.5 Continuity Buzzer MIT300, 310 MIT320, 330 MIT310A MIT300, 310, 320, 330 MIT310A Operates at < 5 Adjustable 1 to 20 Operates at < 5 Response time <20 ms Response time <100 mS Resistance range MIT320/330 (can be used for diode testing) Measuring Range: 10 - 1 M Open Circuit Voltage: 5V Short Circuit Current: 1.5 mA Accuracy (at 20 C): 5% 2 digits up to 100 k Measuring Range (MIT310A) 0 - 2k (refer to continuity) Further applications can be found in panel building, testing of motors, generators, switchgear and power tools, street lighting and low volume manufacturing environments etc. Voltage range Measuring Range: The MIT300 range is supplied with a full 3 year warranty. MIT310A Temperature coefficient: SPECIFICATIONS Default voltmeter All modes except off MIT310, 320, 330 Insulation ranges Nominal Test Voltage MIT310, 310A, 320, 330 MIT300 Measuring Range All instruments Short Circuit Current Test Current on Load Accuracy (at 20 C) MIT300, 310, 320, 330 MIT310A Continuity ranges Measuring Range: Open Circuit Voltage: Short Circuit Current: MIT300, 310, 320, 330 MIT310A 1000 V, 500 V, 250 V (d.c.) 500 V, 250 V (d.c.) 10 k - 999 M on all ranges 1.5 mA nominal 1 mA at min. pass values of insulation (as specified in BS7671, HD 384 and IEC 364) 3%, 2 digits up to 10 M, 5% up to 100 M, 30% up to full scale <2.5% of scale length (or 30% of reading 200 k to 10 M) 0.01 - 99.9 (0 -50 on analog scale) 5 V 1 V 205 mA +10 mA -5 mA 200 - 250 mA 3% 2 digits 2.5% of scale length (or 30% of reading 0.2 to 2 k) Accuracy (at 20 C) MIT300, 310, 320, 330 0 - 600 V a.c. (50/60 Hz) or d.c. d.c. or a.c. (50/60 Hz): 1%, 2 digits 2.5% of scale length for 50/60Hz <0.1% per C on all ranges. >25 V a.c. or d.c. is applied display will operate as a voltmeter. Beeps and flash `V' on the display All modes including OFF MIT300 MIT310A Test inhibit: If more than 50 volts is detected, testing will be inhibited. AutoPower Down (MIT310, 320, 330) Auto power down operates after 10 minutes if left in standby mode. Temperature and humidity Operating Range: 14F to 140F (-10C to +60C) 93% R.H. at +40C max. Operating Humidity: -13F to +158F (-25C to +70C) Storage Range: Test Result Storage (1000 results) 255 locations Job Number Distribution Board no. 99 locations Circuits 99 locations Phases P1, P2, P3 Last recorded result may be recalled to the display. All data can be downloaded to a PC using Download Manager (supplied) or Megger Powersuite Professional of Windows software MIT300 Series Insulation and Continuity Testers MIT300 SERIES BENEFITS INCLUDE: MIT300 MIT310 MIT310A Analog MIT320 MIT330 250 V 500 V 999 M 999 M 999 M 999 M 999 M Insulation testing 1000 V Test range Insulation limit alarm (0.01 M to 999 M) Continuity testing Continuity to 100 Continuity buzzer Lead null to 9ohms 0.5 Adjustable buzzer 1 to 20 Audible buzzer disable 600 V 600 V Voltage measurement Volts AC/DC 600 V 600 V Resistance measurement 10 to 1 M range Features Voltage warning Default voltmeter Backlit display Backlight selector ranges Locking test button Auto powerdown Switched test probe IP54 weatherproof Accepts rechargeable batteries 1000 Test result storage Downloading Calibration certificate 3 year warranty Communications USB interface Environmental Protection IP54 Fuses Terminals 500 mA (F) 600 V, 32 x 6 mm Ceramic HBC 10 kA minimum. Display shows if fuse is ruptured. Safety Meets the requirements of IEC61010-1 Cat III 600 V phase to earth. Automatic discharge After an insulation test the item under test will be discharged automatically. Any voltage present will be indicated on the display so that the discharge can be monitored. Power supply Battery: 8 x 1.5 V cells IEC LR6 type(AA alkaline). Rechargeable NiCd or NiMH cells may be used. Battery condition is constantly shown on the display as a four-section bargraph. Battery Life 5000 consecutive tests (5 seconds per test) on any test using 2Ah batteries. Weight All units: 980 gms Dimensions All units: 203 x 148 x 78 mm (8 x 5.7 x 3.2 inches) E.M.C. In accordance with IEC61326 including amendment No.1 MIT300 Series Insulation and Continuity Testers ORDERING INFORMATION Item (Qty) Cat. No. Item (Qty) Cat. No. MIT300 250 V , 500 V insulation tester MIT300-EN Included Accessories MIT310 250 V, 500 V, 1000 V insulation tester MIT310-EN Test lead set and crocodile clips 6220-779 SP4F Switch probe (MIT320 and MIT330 only) 6220-809 MIT310A 250 V, 500 V,1000 V analog insulation tester MIT310A-EN MIT320 250 V, 500 V, 1000 V insulation tester MIT320-EN MIT330 250 V, 500 V, 1000 V insulation tester MIT330-EN UK Archcliffe Road, Dover CT17 9EN England T +44 (0) 1 304 502101 F +44 (0) 1 304 207342 UKsales@megger.com UNITED STATES 4271 Bronze Way Dallas, TX 75237-1019 USA T 1 800 723 2861 (USA only) T +1 214 333 3201 F +1 214 331 7399 USsales@megger.com Optional Accessories Fused test lead set 6220-789 PowerSuite Pro-Lite 16th 6111-695 OTHER TECHNICAL SALES OFFICES Taby SWEDEN, Norristown USA, Sydney AUSTRALIA, Toronto CANADA, Trappes FRANCE, Kingdom of BAHRAIN, Mumbai INDIA, Johannesburg SOUTH AFRICA, and Chonburi THAILAND Registered to ISO 9001:2000 Cert. no. Q 09290 Registered to ISO 14001-1996 Cert. no. EMS 61597 MIT300_DS_enUS_V10 www.megger.com Megger is a registered trademark